<strong>8D</strong> <strong>Series</strong><br />

Common Section<br />

Wiring instruction<br />

Cable preparation and wire stripping<br />

Contact<br />

size<br />

L min<br />

L max<br />

#22D #20 #16 #12 #8 #4<br />

3.58<br />

.14<br />

3.99<br />

.16<br />

5.31<br />

.21<br />

5.82<br />

.23<br />

Insertion of wire in contact barrel<br />

When inserting the stripped wire into the contact barrel check that no<br />

strands are left outside and that the wire is visible through the wire<br />

inspection hole in the barrel.<br />

Important :<br />

- Slide any accessories over wire strands before carrying out the following operations.<br />

- Contacts are inserted and extracted from the rear of the connector.<br />

Insertion of the contacts<br />

1 - Engage the crimp cable / contact asembly into the longitudinal slot of the<br />

plastic tool (coloured tip).<br />

Slide the tool down the cable until the tip of the tool abuts the contact<br />

retention shoulder.<br />

2 - Introduce the contact into the required contact cavity in the insulator, pushing<br />

tool axialy, until the contact snaps into position in clip.<br />

3 - Withdraw the tool (from rear). Check that contact is firmly locked by<br />

pulling wire gently.<br />

When connector is fully loaded, check the position of contact tips. They should<br />

all be in the same plane.<br />

Nota : For larger sizes of cable which are stiff enough manual insertion without<br />

tool is preferable.<br />

70 © 2011 - SOURIAU<br />

5.31<br />

.21<br />

5.82<br />

.23<br />

5.31<br />

.21<br />

5.82<br />

.23<br />

12.5<br />

.49<br />

13<br />

.51<br />

12.5<br />

.49<br />

13<br />

.51<br />

1<br />

2<br />

3<br />

Conductor<br />

insulation<br />

L = length of wire stripping<br />

L<br />

0.5 to 0.8 mm<br />

Wire<br />

Barrel<br />

Inspection hole