22.11.2017 Views

V25.1 Software Guide Panamatic Mini, Midi, Optima 2 v1.5

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7. Quick guide to parameter codes for software version 25.1<br />

Version 25.1 is displayed on the machine as V125<br />

<strong>V25.1</strong><br />

Code Description Standard <strong>Mini</strong>mum Maximum<br />

A0 Maintenance count 50 01 99<br />

A1 Hands-free IR proximity sensitivity 80 00 99<br />

A2 Machine start options N/A N/A N/A<br />

A3 24 hour pump run / wash 01 00 3<br />

A4<br />

Rinse wash time<br />

<strong>Mini</strong> 15<br />

<strong>Midi</strong> 15<br />

<strong>Optima</strong> 10<br />

10 60<br />

A5 (Not used) N/A N/A N/A<br />

A6 Lid pre-open delay time (Seconds) 00 00 20<br />

A7 Lid auto close time (Seconds) 60 00 60<br />

AA Disinfection temperature setting (Degrees C) 80 75 90<br />

AB Initial Fill 20 10 60<br />

AC Maximum cycle time (Minutes) 10 02 15<br />

AD Thermal disinfection time (Seconds) 75 60 99<br />

AE Blockage retries 01 01 10<br />

AF Rinse time (Seconds) 15 10 60<br />

B0 Chemical dosing pump run time (seconds) 40 10 60<br />

B2 Fill time out (Seconds) 10 02 30<br />

Note: Version 16, 17, 18, 19, 20 & 21, 22, 23 are the same as Version 125 (<strong>V25.1</strong>)<br />