BRICK TECHNICAL BULLETIN<br />

FIRE RESISTANCE<br />

BTB 13<br />

Concrete masonry in the form of <strong>Edenhall</strong> brick is a non combustible construction material possessing excellent fire resisting properties.<br />

The resistance to fire within a structure utilising concrete masonry products is a function of:<br />

1. The thickness of the units involved<br />

2. The function of the wall, ie. whether or not it is load-bearing<br />

3. Wall construction, ie. whether it is single leaf or cavity construction<br />

4. The applied wall finish, whether plastered or otherwise<br />

5. Finally, the type of aggregate used to produce the masonry units<br />

<strong>Edenhall</strong>’s products are all produced from Class 1 aggregates, are classed as non-combustible with a zero spread of flame, and are<br />

further classed as Category A1 in accordance with BS 13501-1.<br />

The following tables indicate the nominal fire resistance periods for <strong>Edenhall</strong>’s various types of masonry, ie. common and facing bricks.<br />

They are based on Table 14 of BS 5628: Part 3.<br />

Wall Thickness<br />

made from Brick<br />

Fire Resistance in Hours<br />

No Finish<br />

VG Finish<br />

Wall Thickness<br />

made from Brick<br />

Fire Resistance in Hours<br />

No Finish<br />

VG Finish<br />

1. Load Bearing Single Leaf Wall<br />

100mm 2 3<br />

140mm 4 6<br />

215mm 6 6<br />

2. Non Load Bearing Single Leaf Wall<br />

100mm 2 3<br />

140mm 3 6<br />

215mm 6 6<br />

3. Load Bearing Cavity Wall<br />

100mm 6 -<br />

140mm 6 -<br />

215mm 6 -<br />

4. Non Load Bearing Cavity Wall<br />

100mm 6 -<br />

140mm 6 -<br />

215mm 6 -<br />

Notes:<br />

• <strong>Edenhall</strong> bricks are produced in a minimum thickness of 100mm.<br />

• Finishes should be not less than 13mm plaster on each face of a single leaf wall and the exposed faces of a cavity wall.<br />

VG is Vermiculite: gypsum plaster.<br />

• The thicknesses quoted are in millimetres and represent the work size of the unit or, where applicable for solid walls, the<br />

sum of the work sizes for two units including the joint between them.<br />

Head Office: PD <strong>Edenhall</strong> Ltd, Danygraig Road, Risca, Newport, NP11 6DP Tel: 01633 612671 Fax: 01633 601280 edenhall.co.uk<br />

The information and guidance contained in our <strong>Technical</strong> Bulletins, <strong>Technical</strong> Data Sheets and <strong>Technical</strong> Manual are regularly reviewed as part of <strong>Edenhall</strong>’s continuous development and<br />

improvement programme. Updates and amendments can be made without notice and the Company cannot accept liability for any errors or omissions. The content of this document<br />

and the referenced data sheets and bulletins, including tables, diagrams and images, are subject to copyright.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!