C. Control contents<br />
a. Fan Speed manual<br />
1. Fan speed is changed from normal setting to quiet setting of respective fan speed.<br />
This is to reduce sound of Hi, Me, Lo for 3dB.<br />
2. Fan speed for quiet operation is -100 rpm from setting fan speed.<br />
3. Fan Speed Auto<br />
• If FM Lo<br />
-100 rpm reduce from normal Heating Auto Fan Speed<br />
• If FM Lo<br />
maintain RPM<br />
Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.<br />
12.4. Powerful Mode Operation<br />
When the powerful mode is selected, the internal setting temperature will shift to achieve the setting temperature quickly.<br />
(a) Cooling Operation<br />
(b) Soft Dry Operation<br />
(c) Heating Operation<br />
12.5. ON Timer Control<br />
ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a<br />
comfortable environment when reaching the set ON time.<br />
Seventy minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine<br />
the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.<br />
From the above judgment, the decided operation will start operate earlier than the set time as shown below.<br />