c. e-ion operation pause condition<br />

• When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after indoor fan restarts.<br />

• When indoor intake temperature 40°C. e-ion operation resume after indoor intake temperature < 40°C continuously for 30<br />

minutes.<br />

C. Control Content<br />

a. Indoor fan control<br />

• During any operation mode combines with e-ion operation, fan speed follows respective operation mode.<br />

• During e-ion individual operation - only Auto Fan Speed and no Powerful operation is allowed. Even if Fan Speed button is<br />

pressed, no signal is sent to air conditioner, and no change on LCD display.<br />

Auto Fan Speed for e-ion operation switches between HLo and CLo at pattern below:<br />

b. <strong>Air</strong>flow direction control<br />

• During any operation mode combines with e-ion operation, airflow direction follows respective operation mode.<br />

• During e-ion individual operation, only Auto <strong>Air</strong> Swing is allowed. Even if <strong>Air</strong> Swing button is pressed, no signal is sent to air<br />

conditioner, and no change on LCD display.<br />

c. Timer control<br />

• When ON timer activates when unit stops, previous operation resumes without e-ion operation.<br />

• When ON timer activates during any operation, no change and carry on current operation.<br />

• When OFF timer activates during any operation, all operation stops.<br />

d. Indicator<br />

• When e-ion operation starts, e-ion indicator ON.<br />

e. e-ion Check Mode<br />

• To check if e-ion is malfunctioning, during e-ion operation press “e-ion” button for 15 seconds and release to enter e-ion Check<br />

Mode and supplies power to the e-ion <strong>Air</strong> Purifying System.<br />

• If abnormal discharge is detected at filter (short-circuited) due to water or dust adhesion, etc., the e-ion indicator blinks<br />

immediately.<br />

f. Power failure<br />

• During e-ion individual operation, if power failure occurs, after power resumes, e-ion individual operation resumes<br />

immediately.<br />

• During combination operation, if power failure occurs, after power resumes, combination operation resume immediately.<br />

g. Error Detection Control<br />

When e-ion indicator blink, it indicates error listed below:<br />

i. e-ion <strong>Air</strong> Purifying system main connector to PCB is open:<br />

Judgement Method<br />

• During e-ion operation (include during Patrol operation), e-ion <strong>Air</strong> Purifying system main connector to PCB is opened.<br />

Troubleshooting Methods<br />

• Connect the connector or stop operation (include during Patrol operation) to cancel the blinking.<br />

ii. Abnormal Discharge<br />

Judgement Method<br />

• During e-ion operation, when feedback voltage is -Lo (at microcontroller) is detected, it is judged abnormal discharge and<br />

stops power supplies to the e-ion <strong>Air</strong> Purifying system.<br />

• The unit retries after 30 minutes and repeat for 24 times. (not applicable for e-ion Check Mode)<br />