Panasonic Air Conditioner - LMG
Panasonic Air Conditioner - LMG
Panasonic Air Conditioner - LMG
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Troubleshooting Method<br />
• Press “e-ion” button or “OFF/ON” button to stop the operation and check the e-ion <strong>Air</strong> Purifying system main connector to<br />
PCB.<br />
• After that, press “e-ion” button again to confirm the e-ion indicator not blinking.<br />
• The 24 times counter will be clear after 10 minutes of normal operation or when operation stops.<br />
Error Reset Method<br />
• Press “OFF/ON” button to OFF the operation.<br />
• Press AUTO OFF/ON button at indoor unit to OFF the operation.<br />
• OFF Timer activates.<br />
• Press “e-ion” button during e-ion individual mode.<br />
• Power supply reset.<br />
iii. e-ion breakdown<br />
Judgement Method<br />
• When hi-feedback voltage (at microcontroller) supplied to filter during e-ion stop, due to PCB or filter’s high voltage power<br />
supply damage.<br />
• Operations except e-ion continue. Both Timer indicator and e-ion indicator blink.<br />
Troubleshooting Method<br />
• Press “e-ion” button or “OFF/ON” button to stop the operation.<br />
• Change main circuit board or filter’s high voltage power supply.<br />
• When lo-feedback voltage supplied to e-ion <strong>Air</strong> Purifying system during e-ion operation, e-ion indicator and Timer indicator<br />
stop blinking.<br />
35