d. <strong>Air</strong>flow direction (Horizontal, Vertical) Control<br />
• During any operation mode combines with Patrol operation, airflow direction follows respective operation mode.<br />
• During Patrol individual operation if e-ion starts, only Auto <strong>Air</strong> Swing is allowed. Even if “<strong>Air</strong> Swing” button is pressed, no signal<br />
is sent to air conditioner, and no change on LCD display.<br />
• During Patrol individual operation if e-ion stops, <strong>Air</strong>flow direction louver closed.<br />
e. Indicator<br />
• When Patrol operation starts, Patrol Sensor indicator ON.<br />
• When e-ion operation starts based on dirtiness level, e-ion indicator ON.<br />
f. Remote Control Receiving Sound<br />
• Normal Operation<br />
• Patrol Mode<br />
• Patrol Mode<br />
• Stop<br />
→<br />
→<br />
→<br />
→<br />
Patrol Mode<br />
Stop<br />
Normal Operation<br />
Patrol<br />
g. Timer Control<br />
• When ON timer activates when unit stops, previous operation resumes without Patrol operation.<br />
• When ON timer activates during any operation, no change and carry on current operation.<br />
• When OFF timer activates during any operation, all operation stops.<br />
h. Power failure<br />
• During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes<br />
immediately.<br />
• During combination operation, if power failure occurs, after power resumes combination operation resume immediately.<br />
12.10. e-ion Operation<br />
A. Purpose<br />
This operation provides clean air by producing negative ions to attract dust captured at the positively charged e-ion filters.<br />
B. Control Condition<br />
a. e-ion operation start condition<br />
• During unit running at any operation mode, if “e-ion” button is pressed, combination operation (operation mode + e-ion<br />
operation) starts.<br />
• During unit is OFF, if “e-ion” button is pressed, e-ion individual operation starts.<br />
b. e-ion operation stop condition<br />
• When “OFF/ON” button is pressed to stop the operation.<br />
• When “e-ion” button is pressed again.<br />
• When “Patrol” button is pressed.<br />
• When OFF Timer activates.<br />
:<br />