Yaskawa 2 GA800
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Section: Power Options \<br />
Power Options<br />
Power options are add on devices that can be used to help increase power factor, improve harmonics, and dissipate regenerative energy.<br />
Name<br />
Purpose<br />
• Improves the drive input power factor.<br />
DC Bus Reactor<br />
• Prevents damage to the drive when the power supply capacity is large. Only use this option when the<br />
power supply capacity is more than 600 kVA.<br />
• Decreases harmonic current<br />
• Improves the power supply total power factor.<br />
• Improves the drive input power factor.<br />
AC Reactor<br />
3% Braking Resistor<br />
10% Braking Resistor Unit<br />
Braking Unit<br />
R1000<br />
Single Phase Converter<br />
• Prevents damage to the drive when the power supply capacity is large. Only use this option when the<br />
power supply capacity is more than 600 kVA.<br />
• Decreases harmonic current<br />
• Improves the power supply total power factor.<br />
Decreases the regenerative energy of the motor and decrease the deceleration time (Duty cycle of 3%<br />
ED). An installation attachment is required.<br />
Decreases the regenerative energy of the motor and decrease the deceleration time (Duty cycle of 10%<br />
ED). The unit contains a thermal overload relay.<br />
Use with a braking resistor unit to decrease motor deceleration times.<br />
The R1000 regenerative module is used to divert energy generated by the motor back onto the line for<br />
use by other loads. The energy is directed back onto the line by taking DC voltage from the drive running<br />
the motor and converting it into a three-phase AC voltage waveform.<br />
The Single Phase Converter is used in single-phase to three-phase conversion applications to eliminate<br />
drive derating. The Single Phase Converter significantly reduces stresses on the power grid with near<br />
unity power factor and less than 10% iTHD.<br />
Additional Information<br />
<strong>GA800</strong> Power Options<br />
<strong>GA800</strong> Selection Guide SL.<strong>GA800</strong>.01, <strong>Yaskawa</strong> America, Inc. 17