Yaskawa 2 GA800
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Section: <strong>GA800</strong> Configured Package Specifications<br />
Figure 19: Model Number Key<br />
Base Number<br />
Options<br />
Power Control Special<br />
G8C 4 B 040 P T<br />
S<br />
<strong>GA800</strong> Configured<br />
Power Options (P)<br />
Enclosure and Duty<br />
Rating<br />
1 Type 1 ND<br />
2 Type 12 ND<br />
3 Type 3R ND<br />
4 Type 1 HD<br />
5 Type 12 HD<br />
6 Type 3R HD<br />
Voltage<br />
A 240 V<br />
B 480 V<br />
Current<br />
Rated Amps<br />
(Ex.: “040”=40 A)<br />
C Circuit Breaker (65 kA) (1)<br />
M Circuit Breaker (100 kA) (1) Select None or One<br />
E Circuit Breaker (Std) (1)<br />
D Non-Fused Disconnect<br />
J DB w/OH Shutdown (1)(2)(4)<br />
L Dynamic Braking (2)(4) Select None or One<br />
F Input Fuses (1) Select None or One<br />
R 3% Line Reactor<br />
X 3% Bus Reactor (5)<br />
Select None or One<br />
H 3% Load Reactor<br />
N Cap Filter Select None or One<br />
3 Space Heater (3)<br />
Select None or One<br />
2 Surge Suppressor (3)<br />
4 50 Degree C Ambient (3)<br />
Control & Communications (T) Group (6)<br />
C PROFINET dual port (SI-EP3)<br />
D EtherNet/IP dual port (SI-EN3D)<br />
G DeviceNet (SI-N3)<br />
Group 1:<br />
H PROFIBUS-DP (SI-P3)<br />
Select<br />
Q Modbus TCP/IP dual port (SI-EM3D)<br />
None or One<br />
A Analog Input<br />
F Digital Input<br />
N Analog Monitor<br />
Group 2<br />
E Digital Output<br />
X<br />
PG-X3 Feedback Card<br />
V 120 V Digital Interface<br />
Y Hand/Off/Auto Switch<br />
Z Speed Pot<br />
M Keypad Viewing Window (3)<br />
Group 3:<br />
Select<br />
None or One<br />
Group 4<br />
B<br />
Bluetooth Keypad<br />
Special<br />
1) Option F is not allowed with options E,C,J, or M for the following 480 V package models because input fusing is automatically included:<br />
G8C1B007 - G8C1B720, G8C2B065 - G8C2B720, G8C3B180 - G8C3B720<br />
G8C4B004 - G8C4B590, G8C5B052 - G8C5B590, G8C6B156 - G8C6B590<br />
2) Options J and L not allowed together.<br />
3) Type 3R enclosures only.<br />
4) Not available for Type 3R enclosures.<br />
5) 3% Bus reactors are only available as an option on small ratings - see table; large drives have a bus reactor as standard.<br />
6) If no option from Group 1 or Group 3 is selected, then both options from Group 2 may be selected.<br />
If no option from Group 1 is selected, then ALL options from Group 2 and Group 3 may be selected.<br />
Select anything from Group 4, regardless of other group selections.<br />
<strong>GA800</strong> Selection Guide SL.<strong>GA800</strong>.01, <strong>Yaskawa</strong> America, Inc. 63