Section: <strong>GA800</strong> Configured Package Specifications<br />

Figure 19: Model Number Key<br />

Base Number<br />

Options<br />

Power Control Special<br />

G8C 4 B 040 P T<br />

S<br />

<strong>GA800</strong> Configured<br />

Power Options (P)<br />

Enclosure and Duty<br />

Rating<br />

1 Type 1 ND<br />

2 Type 12 ND<br />

3 Type 3R ND<br />

4 Type 1 HD<br />

5 Type 12 HD<br />

6 Type 3R HD<br />

Voltage<br />

A 240 V<br />

B 480 V<br />

Current<br />

Rated Amps<br />

(Ex.: “040”=40 A)<br />

C Circuit Breaker (65 kA) (1)<br />

M Circuit Breaker (100 kA) (1) Select None or One<br />

E Circuit Breaker (Std) (1)<br />

D Non-Fused Disconnect<br />

J DB w/OH Shutdown (1)(2)(4)<br />

L Dynamic Braking (2)(4) Select None or One<br />

F Input Fuses (1) Select None or One<br />

R 3% Line Reactor<br />

X 3% Bus Reactor (5)<br />

Select None or One<br />

H 3% Load Reactor<br />

N Cap Filter Select None or One<br />

3 Space Heater (3)<br />

Select None or One<br />

2 Surge Suppressor (3)<br />

4 50 Degree C Ambient (3)<br />

Control & Communications (T) Group (6)<br />

C PROFINET dual port (SI-EP3)<br />

D EtherNet/IP dual port (SI-EN3D)<br />

G DeviceNet (SI-N3)<br />

Group 1:<br />

H PROFIBUS-DP (SI-P3)<br />

Select<br />

Q Modbus TCP/IP dual port (SI-EM3D)<br />

None or One<br />

A Analog Input<br />

F Digital Input<br />

N Analog Monitor<br />

Group 2<br />

E Digital Output<br />

X<br />

PG-X3 Feedback Card<br />

V 120 V Digital Interface<br />

Y Hand/Off/Auto Switch<br />

Z Speed Pot<br />

M Keypad Viewing Window (3)<br />

Group 3:<br />

Select<br />

None or One<br />

Group 4<br />

B<br />

Bluetooth Keypad<br />

Special<br />

1) Option F is not allowed with options E,C,J, or M for the following 480 V package models because input fusing is automatically included:<br />

G8C1B007 - G8C1B720, G8C2B065 - G8C2B720, G8C3B180 - G8C3B720<br />

G8C4B004 - G8C4B590, G8C5B052 - G8C5B590, G8C6B156 - G8C6B590<br />

2) Options J and L not allowed together.<br />

3) Type 3R enclosures only.<br />

4) Not available for Type 3R enclosures.<br />

5) 3% Bus reactors are only available as an option on small ratings - see table; large drives have a bus reactor as standard.<br />

6) If no option from Group 1 or Group 3 is selected, then both options from Group 2 may be selected.<br />

If no option from Group 1 is selected, then ALL options from Group 2 and Group 3 may be selected.<br />

Select anything from Group 4, regardless of other group selections.<br />

<strong>GA800</strong> Selection Guide SL.<strong>GA800</strong>.01, <strong>Yaskawa</strong> America, Inc. 63