welded flats mounted to line posts <strong>and</strong> steel section angle support rails.<br />

Mesh shall be taken behind kick boards / rebound boards <strong>and</strong> attached<br />

to prevent h<strong>and</strong> traps.<br />

2.04 Floodlighting<br />

2.04.1 <strong>Design</strong> criteria<br />

The Contractor shall design supply <strong>and</strong> install a floodlighting system to<br />

the MUGA to meet the requirements set out in Appendix A, Tables 1 to 5<br />

as appropriate <strong>and</strong> in full compliance with the planning approval for the<br />

facility.<br />

The works shall include the provision <strong>of</strong> all luminaries, columns, mains<br />

distribution switch gear, sub-circuit protective devices, metering <strong>and</strong><br />

control devices <strong>and</strong> the associated cabling, trenching, ducting & draw pit<br />

installation, back filling <strong>and</strong> making good.<br />

All works shall be carried out in accordance with the latest edition <strong>of</strong> the<br />

IEE wiring regulations.<br />

For courts, the illumination st<strong>and</strong>ard is applied to the individual<br />

Principle Play Areas within the MUGA<br />

For pitches the illumination st<strong>and</strong>ard applies to the Principle Play Area<br />

<strong>of</strong> the pitch.<br />

The following st<strong>and</strong>ards shall apply to all lighting designs<br />

Property Requirement<br />

Overall minimum maintenance<br />

factor<br />

0.80<br />

Glare rating (Gr) 65<br />

Colour temperature (K) > 4000<br />

2.04.2 Column bases<br />

The Contractor shall take full account <strong>of</strong> the ground conditions, as<br />

detailed in the ground investigation survey report, when designing the<br />

bases for the floodlighting columns.<br />