in BS 7044 Part 4 Appendix C.<br />

2 Deviations are considered to be localised undulations 1000mm or<br />

less in length. Deviations over 1000mm shall be considered<br />

<strong>multi</strong>ple deviations<br />

3 Where-ever possible a MUGA should be built with a fall across<br />

the principal direction the direction <strong>of</strong> play<br />

A3.2 Surfacing requirements<br />

A3.2.1 Surfacing durability<br />

The surfacing shall comply with the following durability requirements.<br />

Property Test Test<br />

Requirement<br />

method condition<br />

Surface BS 7044 As detailed In accordance with Table 3 <strong>of</strong> BS<br />

durability<br />

in BS 7044<br />

Part 4<br />

7044 Part 4 Class O<br />

Surface BS 7044 As detailed In accordance with Table 4 <strong>of</strong> BS<br />

Environmental<br />

in BS 7044 7044 Part 4<br />

Resistance<br />

Part 4<br />

Tensile<br />

properties<br />

IAAF N/A Tensile strength: 0.4 MPA<br />

Elongation at break: 40%<br />

A3.2.2 Installation<br />

There shall be no ridges, changes in the playing surface texture or bay<br />

joints that result in erratic ball behaviour. Bay joints shall, as far as<br />

possible, accord with play lines <strong>and</strong> be longitudinal along the length <strong>of</strong><br />

the court(s) with no discernible cross-joints.<br />

A3.2.3 Line Marking<br />

Line markings shall be in accordance with the relevant sports governing<br />

body rules. Unless stated in the rules all lines shall be 50mm wide <strong>and</strong><br />

applied using at least two coats <strong>of</strong> paint. When measured with a<br />

calibrated steel tape all line markings shall be within 20mm <strong>of</strong> their true<br />

position as specified in the appropriate rule. Markings shall not deviate<br />

by more than 10mm from a line joining their ends, nor include any<br />

sudden steps. Line edges shall be parallel <strong>and</strong> uniform.<br />