A4.3 Floodlighting<br />

The minimum performance <strong>of</strong> the floodlighting system shall be as<br />

follows:<br />

Property Requirement<br />

Maintained average illuminance -<br />

Full lighting<br />

>200 Lux<br />

Uniformity<br />

Lighting<br />

(Min/Ave) – Full<br />

> 0.7<br />

Maintained average illuminance –<br />

> 200 Lux<br />

secondary<br />

training etc<br />

level lighting for<br />

Illumination st<strong>and</strong>ards shall be based on measurements taken after<br />

dark at ground level.<br />

A4.4 Testing on completion<br />

On completion <strong>of</strong> the works the MUGA (s) shall be tested as detailed in<br />

the following schedule.<br />

Property Testing requirements<br />

Force Reduction Shall be determined in at least three<br />

locations. The temperature <strong>of</strong> the surface<br />

shall be between 10°C <strong>and</strong> 30°C.<br />

Vertical deformation Shall be determined in at least three<br />

locations. The temperature <strong>of</strong> the surface<br />

shall be between 10°C <strong>and</strong> 30°C.<br />

Slip resistance Shall be determined in at least five<br />

locations including all court colours <strong>and</strong><br />

line marking colours.<br />

Tests shall be made under wet<br />

conditions<br />

Permeability The permeability rate <strong>of</strong> the surface shall<br />

be determined in not less than two<br />

locations.<br />

Regularity The entire area shall be assessed.<br />

Property Testing requirements<br />

Gradients The principal gradients <strong>of</strong> the MUGA<br />

shall be measured <strong>and</strong> the design levels<br />

calculated.<br />