Shimadzu Techno-Research Inc., Japan - UNEP Chemicals
Shimadzu Techno-Research Inc., Japan - UNEP Chemicals
Shimadzu Techno-Research Inc., Japan - UNEP Chemicals
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
CV%rob<br />
��Trends Trends of CV % rob of round robin study in<br />
soil sample<br />
30%<br />
25%<br />
20%<br />
15%<br />
10%<br />
5%<br />
0%<br />
123789-HxCDD<br />
1234678-HpCDD<br />
OCDD<br />
2378-TeCDF<br />
12378-PeCDF<br />
23478-PeCDF<br />
123478-HxCDF<br />
123678-HxCDF<br />
123789-HxCDF<br />
234678-HxCDF<br />
1234678-HpCDF<br />
1234789-HpCDF<br />
OCDF<br />
344'5-TeCB(#81)<br />
2378-TeCDD<br />
12378-PeCDD<br />
123478-HxCDD<br />
123678-HxCDD<br />
Isomer<br />
33'44'-TeCB(#77)<br />
33'44'5-PeCB(#126)<br />
33'44'55'-HxCB(#169)<br />
2'344'5-PeCB(#123)<br />
23'44'5-PeCB(#118)<br />
233'44'-PeCB(#105)<br />
2344'5-PeCB(#114)<br />
23'44'55'-HxCB(#167)<br />
233'44'5-HxCB(#156)<br />
233'44'5'-HxCB(#157)<br />
233'44'55'-HpCB(#189)<br />
TOTAL TEQ<br />
2nd round robin study 4th round robin study 5th round robin study<br />
SHIMADZU TECHNO RESEARCH, <strong>Inc</strong>.<br />
different results of 1,2,3,7,8-PeCDF using different GC phase<br />
Type of GCcolumn<br />
SP-2331, CP-<br />
Sil88<br />
BPX-DXN, DBtype,<br />
RH-12MS<br />
Lab.No. Average<br />
(pg/g)<br />
Max Min SD Median NIQR CV%<br />
rob<br />
48 4.64 5.50 3.80 0.42 4.63 0.33 7.11<br />
29 3.30 6.20 2.20 0.66 3.20 0.32 9.85<br />
different results of 1,2,3,4,7,8-HxCDF using different GC phase<br />
Type of GCcolumn<br />
SP-2331, CP-<br />
Sil88<br />
BPX-DXN, DBtype,<br />
RH-12MS<br />
Differences of analytical results by different GC phase<br />
Lab.No. Average<br />
(pg/g)<br />
Max Min SD Median NIQR CV%<br />
rob<br />
48 6.51 8.20 5.40 0.58 6.51 0.52 7.97<br />
29 5.65 8.80 4.10 0.78 5.63 0.48 8.57<br />
These results indicates that different GC phase shows different results especially for<br />
1,2,3,7,8-PeCDF. The main causes of this differences are due to co-eluting congeners for<br />
polar GC phase (SP-2331 or CP-Sil88)<br />