Connection of the two-wire cable<br />
1. The lower ends (= hub side) of the two-wire cable must be<br />
stripped by approx.18 mm.<br />
2. Insert both cable ends in the connector (#11), using the righthand<br />
side of the connector for the earthed cable.<br />
3. Bend the protruding ends over so that they pass into<br />
the slots provided for this purpose and do not under any<br />
circumstances let them come<br />
into contact with each other.<br />
4. Connect the other end of the<br />
two-wire cable in accordance<br />
with the specifi cation of the<br />
headlight used or the external<br />
light switch.<br />
Warning: To prevent short<br />
circuiting, both ends of the earthed<br />
cable must be “grounded” or<br />
connected to the designated<br />
contacts. Mixing up the contacts<br />
will cause short circuiting,<br />
malfunctioning of the lighting<br />
system and damage to the<br />
hub dynamo if operated over a<br />
prolonged period.<br />
Bend the cable<br />
ends over<br />
5. Attach the cable to the fork so that it is protected<br />
throughout its length from the hub to the headlight.<br />
6. Test whether the lighting system functions by lifting the<br />
front wheel off the ground and setting it in motion in the<br />
direction indicated on the hub.<br />
Front<br />
headlight<br />
(#8)<br />
Wire<br />
(#9)<br />
insert<br />
Earthed<br />
cable<br />
(#10)<br />
Connector<br />
(#11)<br />
<strong>Dynamo</strong><br />
hub<br />
(#4)<br />
Note: If the lighting system does not function, check whether the wiring has short<br />
circuited and whether the contacts are loose, or have the installation checked by your<br />
SR SUNTOUR dealer.<br />
Maintenance and Servicing<br />
The hub dynamos in the SR SUNTOUR DH-CT-600 series require minimal maintenance and<br />
their positioning need only be checked for excessive clearance every 1,000 km. In the event of<br />
excessive clearance, please seek advice from your SR SUNTOUR dealer.<br />
Note: The hub should be cleaned at regular intervals and if it becomes extremely dirty.<br />
Use a sponge with lukewarm water and some soap. Do not under any circumstances<br />
use a high-pressure or steam jet device on the hub as this may destroy the washers and<br />
result in an infl ux of water and cause the lubricants that were added at the factory to be<br />
washed out.<br />