Connection of the two-wire cable<br />

1. The lower ends (= hub side) of the two-wire cable must be<br />

stripped by approx.18 mm.<br />

2. Insert both cable ends in the connector (#11), using the righthand<br />

side of the connector for the earthed cable.<br />

3. Bend the protruding ends over so that they pass into<br />

the slots provided for this purpose and do not under any<br />

circumstances let them come<br />

into contact with each other.<br />

4. Connect the other end of the<br />

two-wire cable in accordance<br />

with the specifi cation of the<br />

headlight used or the external<br />

light switch.<br />

Warning: To prevent short<br />

circuiting, both ends of the earthed<br />

cable must be “grounded” or<br />

connected to the designated<br />

contacts. Mixing up the contacts<br />

will cause short circuiting,<br />

malfunctioning of the lighting<br />

system and damage to the<br />

hub dynamo if operated over a<br />

prolonged period.<br />

Bend the cable<br />

ends over<br />

5. Attach the cable to the fork so that it is protected<br />

throughout its length from the hub to the headlight.<br />

6. Test whether the lighting system functions by lifting the<br />

front wheel off the ground and setting it in motion in the<br />

direction indicated on the hub.<br />

Front<br />

headlight<br />

(#8)<br />

Wire<br />

(#9)<br />

insert<br />

Earthed<br />

cable<br />

(#10)<br />

Connector<br />

(#11)<br />

<strong>Dynamo</strong><br />

hub<br />

(#4)<br />

Note: If the lighting system does not function, check whether the wiring has short<br />

circuited and whether the contacts are loose, or have the installation checked by your<br />

SR SUNTOUR dealer.<br />

Maintenance and Servicing<br />

The hub dynamos in the SR SUNTOUR DH-CT-600 series require minimal maintenance and<br />

their positioning need only be checked for excessive clearance every 1,000 km. In the event of<br />

excessive clearance, please seek advice from your SR SUNTOUR dealer.<br />

Note: The hub should be cleaned at regular intervals and if it becomes extremely dirty.<br />

Use a sponge with lukewarm water and some soap. Do not under any circumstances<br />

use a high-pressure or steam jet device on the hub as this may destroy the washers and<br />

result in an infl ux of water and cause the lubricants that were added at the factory to be<br />

washed out.<br />