DRIVE SHAFT HOUSING AND COARSE SCREEN<br />

Dismantling:<br />

1. Close the inlet and outlet valves of the filter<br />

and release pressure.<br />

2. Disconnect power supply from the control<br />

board.<br />

3. Remove the cover from the drive shaft<br />

housing (45) by unscrewing the wing nuts<br />

(53.5). Pull out the plug from the solenoid<br />

coil, remove the limit switch sling (50) from<br />

the drive shaft housing by unscrewing the<br />

bolts (51).<br />

4. Carefully put the limit switch sling near the<br />

filter to avoid any damage to the electrical<br />

wires.<br />

5. Disconnect the pilot tube (40.3) from the<br />

solenoid valve (41) and connector (40.2).<br />

6. Disconnect the drain pipe from the exhaust<br />

valve.<br />

7. Remove the drive unit (37) from the drive<br />

shaft housing (24) by unscrewing the nuts<br />

(26.4) from the bolts (26). By doing so the<br />

drive shaft key (36) will be pulled out.<br />

8. Pull out the connecting pin (33) by first<br />

removing the split pin (34).<br />

9. Turn the drive shaft (35) using a suitable<br />

spanner in order to release it from the<br />

scanner shaft (9.3).<br />

10. Partially release the tightening nut (32).<br />

11. Dismantle the drive shaft housing (24) from<br />

the filter housing (14) by unscrewing the<br />

bolts (25).<br />

12. Pull out the flushing chamber (19) and the<br />

coarse screen (18).<br />

Assembly:<br />

1. Insert the coarse screen (18) into its place in the filter housing.<br />

2. Apply some grease on the O-ring (22) and insert the flushing chamber into its place. Make sure the scanner pipe enters into its<br />

bearing (23).<br />

3. Install the drive shaft housing (24) into the filter housing (14) with the bolts (25) and tighten them.<br />

4. Connect the drive shaft (35) to the scanner shaft by using the connecting pin (33) and split pin (34).<br />

5. Make sure that the drive shaft key (36) is fitted properly in the gear box. Thread the drive shaft through the drive unit and note<br />

that the drive shaft groove is adjusted in accordance with the drive shaft key.<br />

6. Connect the drive unit (37) to the drive shaft housing (24) with the bolts (26) and tighten them.<br />

7. Connect the pilot tube between the solenoid valve (41) and the connector (40.2).<br />

8. Assemble the limit switch sling in its place and push in the plug of the solenoid coil.<br />

9. Connect the drain pipe to the exhaust valve (42).<br />

10. Operate the control board and make sure the filter is operating properly.<br />

11. Open the inlet and outlet valves and recheck filter operation.<br />