indicate which alarms are sent to the application — gc_GetAlarmFlow( )<br />

Parameter Description<br />

flow points to the destination for the current flow control value. Possible values<br />

for flow control are:<br />

ALARM_FLOW_ALWAYS – all alarms with notification on are sent<br />

to the application (default)<br />

ALARM_FLOW_ALWAYS_BLOCKING – only blocking alarms with<br />

notification on are sent to the application. Non-blocking alarms are<br />

not sent.<br />

ALARM_FLOW_FIRST_AND_LAST – only the first alarm on and<br />

the last alarm off are sent to the application (if their notification<br />

attribute is on). Both blocking and non-blocking alarms are eligible<br />

to be sent.<br />

ALARM_FLOW_FIRST_AND_LAST_BLOCKING – only the first<br />

blocking alarm on and the last blocking alarm off are sent to the<br />

application (if their notification attribute is on)<br />

Termination Events<br />

None<br />

Cautions<br />

None<br />

Errors<br />

If this function returns