CAMLOG Vario SR Prosthetic Components
CAMLOG Vario SR Prosthetic Components
CAMLOG Vario SR Prosthetic Components
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
VARIO <strong>SR</strong><br />
PROSTHETIC COMPONENTS FOR<br />
OCCLUSALLY SCREW-RETAINED<br />
RESTORATIONS<br />
FOR EVEN MORE OPTIONS WITH THE<br />
<strong>CAMLOG</strong> ® IMPLANT SYSTEM<br />
Occlusally screw-retained crown, bridge and bar constructions<br />
Bridging large implant axis divergences<br />
Widening the application range of the <strong>CAMLOG</strong> ® Implant System<br />
Aligning tool for implant alignment control<br />
a perfect fit
<strong>Vario</strong> <strong>SR</strong> <strong>Prosthetic</strong>s<br />
ALL ADVANTAGES<br />
AT A GLANCE<br />
SIMPLY WELL THOUGHT OUT<br />
• Precision and rotational stability due to the patented Tube-in-Tube<br />
implant abutment connection<br />
• Sterile packaged and color-coded <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments<br />
• Proven <strong>CAMLOG</strong> handling<br />
SIMPLY MORE OPTIONS<br />
• For occlusally screw-retained crown, bridge and bar restorations on<br />
<strong>CAMLOG</strong> ® implants<br />
• For bridging large implant axis divergences<br />
• Where bone supply is reduced and anatomical structures are unfavorable<br />
for implantation<br />
SIMPLY WELL THOUGHT OUT<br />
The patented and proven Tube-in-Tube construction ensures a precise,<br />
mechanically sturdy and rotationally stable connection between <strong>CAMLOG</strong> ®<br />
implant and <strong>CAMLOG</strong> ® abutment.<br />
Handling of the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments is practical and logical – like<br />
everything from <strong>CAMLOG</strong>. The <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments come colorcoded<br />
and sterile packed. When immediately inserted into the implant, sterilization<br />
of the abutment as recommended is not required.<br />
On straight abutments, the antirotational mechanism for crown restorations<br />
is ensured by three surfaces, on angled abutments, by one surface.<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments: straight, 20° and 30° angled<br />
The detailed dimensions of the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments and more informations are<br />
available from the working instruction “Occlusally screw-retained restorations with <strong>Vario</strong> <strong>SR</strong><br />
prosthetic components on <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments”, Art. No. J8000.0124.<br />
SIMPLY PRACTICAL<br />
• Impression-taking possible over the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment<br />
shoulder or <strong>CAMLOG</strong> ® implant shoulder<br />
• Specific <strong>Vario</strong> <strong>SR</strong> components available for impression-taking and cast<br />
fabrication<br />
• Specific <strong>Vario</strong> <strong>SR</strong> protection and titanium caps available for temporary<br />
restorations<br />
• Standardized fabrication of the prosthetic restoration thanks to<br />
prefabricated components<br />
SIMPLY PROVEN<br />
• Choice between cement-retained or occlusally screw-retained crown and<br />
bridge constructions for the <strong>CAMLOG</strong> ® Implant System<br />
• Aligning tool for checking the respective prosthetic insertion direction<br />
and alignment of the implant grooves
SIMPLY MORE OPTIONS<br />
The new <strong>Vario</strong> <strong>SR</strong> prosthetic components extend the application possibilities<br />
of the <strong>CAMLOG</strong> ® Implant System in prosthetic restorations.<br />
OCCLUSALLY SCREW-RETAINED RESTORATION<br />
With the new <strong>Vario</strong> <strong>SR</strong> prosthetic components, you now have the option of<br />
fabricating occlusally screw-retained crown and bridge restorations with<br />
the <strong>CAMLOG</strong> ® Implant System. Bar structures are also possible.<br />
<strong>CAMLOG</strong> ® VARIO <strong>SR</strong> ABUTMENT OVERVIEW<br />
Straight, 20° and 30°<br />
angled abutments<br />
Abutment screws<br />
Straight <strong>CAMLOG</strong> ®<br />
<strong>Vario</strong> <strong>SR</strong> abutments,<br />
Ø 3.8/4.3 mm<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />
abutment screw<br />
M 1.6<br />
Angled <strong>CAMLOG</strong> ®<br />
<strong>Vario</strong> <strong>SR</strong> abutments,<br />
Ø 3.8/4.3 mm<br />
<strong>CAMLOG</strong> ®<br />
abutment screw<br />
M 1.6<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments are available in straight and angled versions for implant<br />
diameters 3.8/4.3/5.0/6.0 mm. Straight <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments are fixed in<br />
the implant using the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment screw.<br />
ANATOMICALLY CHALLENGING AREAS<br />
20° and 30° angled <strong>Vario</strong> <strong>SR</strong> abutments are available for bridging large<br />
implant axis divergences. Where bone supply is reduced and anatomical<br />
structures are unfavorable for implantation, the implants can be placed<br />
in the distal direction and an appropriate prosthetic restoration can be<br />
created. Optimum use of the bone supply is thus ensured.<br />
Straight <strong>CAMLOG</strong> ®<br />
<strong>Vario</strong> <strong>SR</strong> abutments,<br />
Ø 5.0/6.0 mm<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />
abutment screw<br />
M 2.0<br />
Angled <strong>CAMLOG</strong> ®<br />
<strong>Vario</strong> <strong>SR</strong> abutments,<br />
Ø 5.0/6.0 mm<br />
<strong>CAMLOG</strong> ®<br />
abutment screw<br />
M 2.0
SIMPLY PRACTICAL<br />
INDIVIDUAL IMPRESSION-TAKING OPTIONS<br />
For bridge and bar constructions, the impression can be taken using<br />
<strong>Vario</strong> <strong>SR</strong> impression caps, open or closed tray, directly over the <strong>CAMLOG</strong> ®<br />
<strong>Vario</strong> <strong>SR</strong> abutment already in its final position in the implant. If space is<br />
limited, you can shorten the retention screw of the impression cap, open<br />
tray, by 3 mm extra-orally. For crown restorations, the impression can be<br />
taken directly over the <strong>CAMLOG</strong> ® implant shoulder using <strong>CAMLOG</strong> ®<br />
impression posts, open or closed tray.<br />
VARIO <strong>SR</strong> IMPRESSION-TAKING, CAST FABRICATION, FABRICATION OF THE SUPERSTRUCTURE<br />
Impression-taking for bridge<br />
and bar constructions<br />
Cast fabrication for bridge and bar<br />
constructions<br />
<strong>Prosthetic</strong> screw<br />
Fabrication of the<br />
superstructure<br />
SCREWDRIVER<br />
Screwdriver, hex, extra short, short, long<br />
<strong>Vario</strong> <strong>SR</strong> impression caps, open tray,<br />
Ø 3.8/4.3 and 5.0/6.0 mm<br />
<strong>Vario</strong> <strong>SR</strong> plastic copings<br />
crown/bridge,<br />
Ø 3.8/4.3 and 5.0/6.0 mm<br />
PREFABRICATED PROSTHETIC COMPONENTS<br />
The <strong>Vario</strong> <strong>SR</strong> components enable easy, standardized fabrication of prosthetic<br />
restorations. Burn-out plastic copings can be used to fabricate cast<br />
crown and bridge constructions. The titanium caps have a retention surface<br />
on the outside and are designed for temporary or final bridge constructions<br />
made out of plastic. For laser-welded bar constructions, titanium bases for<br />
bars are available.<br />
<strong>Vario</strong> <strong>SR</strong> analogs,<br />
Ø 3.8/4.3 and 5.0/6.0 mm<br />
<strong>Vario</strong> <strong>SR</strong> prosthetic screw for all<br />
<strong>Vario</strong> <strong>SR</strong> caps and diameters<br />
<strong>Vario</strong> <strong>SR</strong> titanium caps<br />
bridge,<br />
Ø 3.8/4.3 and 5.0/6.0 mm<br />
Important note: The special design of the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment screw and<br />
the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> lab screw for the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment straight,<br />
requires the exclusive use of the screwdriver, hex, Art. No. J5316.0501/0502/0503/0504/0510!<br />
<strong>Vario</strong> <strong>SR</strong> impression caps, closed tray,<br />
Ø 3.8/4.3 and 5.0/6.0 mm<br />
<strong>Vario</strong> <strong>SR</strong> bases for bars,<br />
Ø 3.8/4.3 and 5.0/6.0 mm
<strong>Vario</strong> <strong>SR</strong> <strong>Prosthetic</strong>s<br />
SIMPLY PERFECTED<br />
NEW PROSTHETIC SCREW CONNECTION FOR<br />
STRAIGHT <strong>CAMLOG</strong> ® VARIO <strong>SR</strong> ABUTMENTS<br />
Straight <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments are fixed in the implant using the<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment screw. The <strong>Vario</strong> <strong>SR</strong> caps are secured<br />
using the <strong>Vario</strong> <strong>SR</strong> prosthetic screw when inserting the superstructure.<br />
The prosthetic screw engages in the thread in the head of the <strong>CAMLOG</strong> ®<br />
<strong>Vario</strong> <strong>SR</strong> abutment screw and fixes the cap to the abutment.<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment,<br />
straight<br />
NEW 20° AND 30° ALIGNING TOOLS FOR BETTER HANDLING<br />
AND MORE TIME SAVINGS<br />
If you are placing several implants, the <strong>Vario</strong> <strong>SR</strong> 20° and 30° aligning tools<br />
can be used to check the respective insertion direction and alignment of the<br />
implant grooves before inserting the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments.<br />
Just put the respective aligning tool over the insertion post attached to the<br />
<strong>CAMLOG</strong> ® implant. If necessary, you can slightly adjust the alignment of<br />
the grooves of the inner implant configuration.<br />
The angulation of the <strong>Vario</strong> <strong>SR</strong> aligning tools is identical to the 20° and 30°<br />
angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments.<br />
Angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment 20° and<br />
<strong>Vario</strong> <strong>SR</strong> aligning tool<br />
<strong>Vario</strong> <strong>SR</strong><br />
plastic coping<br />
<strong>Vario</strong> <strong>SR</strong><br />
prosthetic screw<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />
abutment<br />
<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />
abutment screw<br />
Insertion post<br />
Implant<br />
2 chamfer = 20° 3 chamfer = 30°<br />
Angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment 30° and<br />
<strong>Vario</strong> <strong>SR</strong> aligning tool<br />
<strong>Vario</strong> <strong>SR</strong> aligning tool<br />
The angulation points in the opposite direction<br />
of the <strong>CAMLOG</strong> ® implant groove.
HEADQUARTERS<br />
<strong>CAMLOG</strong> Biotechnologies AG | Margarethenstrasse 38 | CH-4053 Basel<br />
info@camlog.com | www.camlog.com<br />
Manufacturer of <strong>CAMLOG</strong> ® products: ALTATEC GmbH, Maybachstraße 5, D-71299 Wimsheim<br />
Subject to change X.J5867.09/2010