11.01.2013 Views

CAMLOG Vario SR Prosthetic Components

CAMLOG Vario SR Prosthetic Components

CAMLOG Vario SR Prosthetic Components

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

VARIO <strong>SR</strong><br />

PROSTHETIC COMPONENTS FOR<br />

OCCLUSALLY SCREW-RETAINED<br />

RESTORATIONS<br />

FOR EVEN MORE OPTIONS WITH THE<br />

<strong>CAMLOG</strong> ® IMPLANT SYSTEM<br />

Occlusally screw-retained crown, bridge and bar constructions<br />

Bridging large implant axis divergences<br />

Widening the application range of the <strong>CAMLOG</strong> ® Implant System<br />

Aligning tool for implant alignment control<br />

a perfect fit


<strong>Vario</strong> <strong>SR</strong> <strong>Prosthetic</strong>s<br />

ALL ADVANTAGES<br />

AT A GLANCE<br />

SIMPLY WELL THOUGHT OUT<br />

• Precision and rotational stability due to the patented Tube-in-Tube<br />

implant abutment connection<br />

• Sterile packaged and color-coded <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments<br />

• Proven <strong>CAMLOG</strong> handling<br />

SIMPLY MORE OPTIONS<br />

• For occlusally screw-retained crown, bridge and bar restorations on<br />

<strong>CAMLOG</strong> ® implants<br />

• For bridging large implant axis divergences<br />

• Where bone supply is reduced and anatomical structures are unfavorable<br />

for implantation<br />

SIMPLY WELL THOUGHT OUT<br />

The patented and proven Tube-in-Tube construction ensures a precise,<br />

mechanically sturdy and rotationally stable connection between <strong>CAMLOG</strong> ®<br />

implant and <strong>CAMLOG</strong> ® abutment.<br />

Handling of the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments is practical and logical – like<br />

everything from <strong>CAMLOG</strong>. The <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments come colorcoded<br />

and sterile packed. When immediately inserted into the implant, sterilization<br />

of the abutment as recommended is not required.<br />

On straight abutments, the antirotational mechanism for crown restorations<br />

is ensured by three surfaces, on angled abutments, by one surface.<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments: straight, 20° and 30° angled<br />

The detailed dimensions of the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments and more informations are<br />

available from the working instruction “Occlusally screw-retained restorations with <strong>Vario</strong> <strong>SR</strong><br />

prosthetic components on <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments”, Art. No. J8000.0124.<br />

SIMPLY PRACTICAL<br />

• Impression-taking possible over the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment<br />

shoulder or <strong>CAMLOG</strong> ® implant shoulder<br />

• Specific <strong>Vario</strong> <strong>SR</strong> components available for impression-taking and cast<br />

fabrication<br />

• Specific <strong>Vario</strong> <strong>SR</strong> protection and titanium caps available for temporary<br />

restorations<br />

• Standardized fabrication of the prosthetic restoration thanks to<br />

prefabricated components<br />

SIMPLY PROVEN<br />

• Choice between cement-retained or occlusally screw-retained crown and<br />

bridge constructions for the <strong>CAMLOG</strong> ® Implant System<br />

• Aligning tool for checking the respective prosthetic insertion direction<br />

and alignment of the implant grooves


SIMPLY MORE OPTIONS<br />

The new <strong>Vario</strong> <strong>SR</strong> prosthetic components extend the application possibilities<br />

of the <strong>CAMLOG</strong> ® Implant System in prosthetic restorations.<br />

OCCLUSALLY SCREW-RETAINED RESTORATION<br />

With the new <strong>Vario</strong> <strong>SR</strong> prosthetic components, you now have the option of<br />

fabricating occlusally screw-retained crown and bridge restorations with<br />

the <strong>CAMLOG</strong> ® Implant System. Bar structures are also possible.<br />

<strong>CAMLOG</strong> ® VARIO <strong>SR</strong> ABUTMENT OVERVIEW<br />

Straight, 20° and 30°<br />

angled abutments<br />

Abutment screws<br />

Straight <strong>CAMLOG</strong> ®<br />

<strong>Vario</strong> <strong>SR</strong> abutments,<br />

Ø 3.8/4.3 mm<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />

abutment screw<br />

M 1.6<br />

Angled <strong>CAMLOG</strong> ®<br />

<strong>Vario</strong> <strong>SR</strong> abutments,<br />

Ø 3.8/4.3 mm<br />

<strong>CAMLOG</strong> ®<br />

abutment screw<br />

M 1.6<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments are available in straight and angled versions for implant<br />

diameters 3.8/4.3/5.0/6.0 mm. Straight <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments are fixed in<br />

the implant using the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment screw.<br />

ANATOMICALLY CHALLENGING AREAS<br />

20° and 30° angled <strong>Vario</strong> <strong>SR</strong> abutments are available for bridging large<br />

implant axis divergences. Where bone supply is reduced and anatomical<br />

structures are unfavorable for implantation, the implants can be placed<br />

in the distal direction and an appropriate prosthetic restoration can be<br />

created. Optimum use of the bone supply is thus ensured.<br />

Straight <strong>CAMLOG</strong> ®<br />

<strong>Vario</strong> <strong>SR</strong> abutments,<br />

Ø 5.0/6.0 mm<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />

abutment screw<br />

M 2.0<br />

Angled <strong>CAMLOG</strong> ®<br />

<strong>Vario</strong> <strong>SR</strong> abutments,<br />

Ø 5.0/6.0 mm<br />

<strong>CAMLOG</strong> ®<br />

abutment screw<br />

M 2.0


SIMPLY PRACTICAL<br />

INDIVIDUAL IMPRESSION-TAKING OPTIONS<br />

For bridge and bar constructions, the impression can be taken using<br />

<strong>Vario</strong> <strong>SR</strong> impression caps, open or closed tray, directly over the <strong>CAMLOG</strong> ®<br />

<strong>Vario</strong> <strong>SR</strong> abutment already in its final position in the implant. If space is<br />

limited, you can shorten the retention screw of the impression cap, open<br />

tray, by 3 mm extra-orally. For crown restorations, the impression can be<br />

taken directly over the <strong>CAMLOG</strong> ® implant shoulder using <strong>CAMLOG</strong> ®<br />

impression posts, open or closed tray.<br />

VARIO <strong>SR</strong> IMPRESSION-TAKING, CAST FABRICATION, FABRICATION OF THE SUPERSTRUCTURE<br />

Impression-taking for bridge<br />

and bar constructions<br />

Cast fabrication for bridge and bar<br />

constructions<br />

<strong>Prosthetic</strong> screw<br />

Fabrication of the<br />

superstructure<br />

SCREWDRIVER<br />

Screwdriver, hex, extra short, short, long<br />

<strong>Vario</strong> <strong>SR</strong> impression caps, open tray,<br />

Ø 3.8/4.3 and 5.0/6.0 mm<br />

<strong>Vario</strong> <strong>SR</strong> plastic copings<br />

crown/bridge,<br />

Ø 3.8/4.3 and 5.0/6.0 mm<br />

PREFABRICATED PROSTHETIC COMPONENTS<br />

The <strong>Vario</strong> <strong>SR</strong> components enable easy, standardized fabrication of prosthetic<br />

restorations. Burn-out plastic copings can be used to fabricate cast<br />

crown and bridge constructions. The titanium caps have a retention surface<br />

on the outside and are designed for temporary or final bridge constructions<br />

made out of plastic. For laser-welded bar constructions, titanium bases for<br />

bars are available.<br />

<strong>Vario</strong> <strong>SR</strong> analogs,<br />

Ø 3.8/4.3 and 5.0/6.0 mm<br />

<strong>Vario</strong> <strong>SR</strong> prosthetic screw for all<br />

<strong>Vario</strong> <strong>SR</strong> caps and diameters<br />

<strong>Vario</strong> <strong>SR</strong> titanium caps<br />

bridge,<br />

Ø 3.8/4.3 and 5.0/6.0 mm<br />

Important note: The special design of the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment screw and<br />

the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> lab screw for the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment straight,<br />

requires the exclusive use of the screwdriver, hex, Art. No. J5316.0501/0502/0503/0504/0510!<br />

<strong>Vario</strong> <strong>SR</strong> impression caps, closed tray,<br />

Ø 3.8/4.3 and 5.0/6.0 mm<br />

<strong>Vario</strong> <strong>SR</strong> bases for bars,<br />

Ø 3.8/4.3 and 5.0/6.0 mm


<strong>Vario</strong> <strong>SR</strong> <strong>Prosthetic</strong>s<br />

SIMPLY PERFECTED<br />

NEW PROSTHETIC SCREW CONNECTION FOR<br />

STRAIGHT <strong>CAMLOG</strong> ® VARIO <strong>SR</strong> ABUTMENTS<br />

Straight <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments are fixed in the implant using the<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment screw. The <strong>Vario</strong> <strong>SR</strong> caps are secured<br />

using the <strong>Vario</strong> <strong>SR</strong> prosthetic screw when inserting the superstructure.<br />

The prosthetic screw engages in the thread in the head of the <strong>CAMLOG</strong> ®<br />

<strong>Vario</strong> <strong>SR</strong> abutment screw and fixes the cap to the abutment.<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment,<br />

straight<br />

NEW 20° AND 30° ALIGNING TOOLS FOR BETTER HANDLING<br />

AND MORE TIME SAVINGS<br />

If you are placing several implants, the <strong>Vario</strong> <strong>SR</strong> 20° and 30° aligning tools<br />

can be used to check the respective insertion direction and alignment of the<br />

implant grooves before inserting the <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments.<br />

Just put the respective aligning tool over the insertion post attached to the<br />

<strong>CAMLOG</strong> ® implant. If necessary, you can slightly adjust the alignment of<br />

the grooves of the inner implant configuration.<br />

The angulation of the <strong>Vario</strong> <strong>SR</strong> aligning tools is identical to the 20° and 30°<br />

angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutments.<br />

Angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment 20° and<br />

<strong>Vario</strong> <strong>SR</strong> aligning tool<br />

<strong>Vario</strong> <strong>SR</strong><br />

plastic coping<br />

<strong>Vario</strong> <strong>SR</strong><br />

prosthetic screw<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />

abutment<br />

<strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong><br />

abutment screw<br />

Insertion post<br />

Implant<br />

2 chamfer = 20° 3 chamfer = 30°<br />

Angled <strong>CAMLOG</strong> ® <strong>Vario</strong> <strong>SR</strong> abutment 30° and<br />

<strong>Vario</strong> <strong>SR</strong> aligning tool<br />

<strong>Vario</strong> <strong>SR</strong> aligning tool<br />

The angulation points in the opposite direction<br />

of the <strong>CAMLOG</strong> ® implant groove.


HEADQUARTERS<br />

<strong>CAMLOG</strong> Biotechnologies AG | Margarethenstrasse 38 | CH-4053 Basel<br />

info@camlog.com | www.camlog.com<br />

Manufacturer of <strong>CAMLOG</strong> ® products: ALTATEC GmbH, Maybachstraße 5, D-71299 Wimsheim<br />

Subject to change X.J5867.09/2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!