DOLD GMBH <strong>Operating</strong> instructions <strong>DMP</strong> <strong>48</strong> <strong>AS</strong> / <strong>AW</strong><br />

• NSG 222A: Interference pulses with broadband spectrum, short build-up time and low<br />

energy<br />

Test values: pulse amplitude ± 2500 V<br />

Rise time: 5 nsec.<br />

Symmetrical and asymmetric feed<br />

• NSG 225A: Interference pulse package with broad interference spectrum<br />

Test values: Stage 3: 2000 V<br />

Repetition frequency: 5 kHz<br />

• NSG 203A: Testing after power outages<br />

Test values: at 100% supply voltage dip: 50 msec.<br />

Repetition frequency: 1 Hz.<br />

<strong>DMP</strong> <strong>48</strong> <strong>AS</strong> Version: 033 Number of pages: 25 of 25<br />

<strong>DMP</strong> <strong>48</strong> <strong>AW</strong> Edition: 08.08.2006 A0e033.doc