Figure 5. Inlet <strong>in</strong>to the first p<strong>on</strong>d <strong>in</strong> Lacor Hospital.<br />

Determ<strong>in</strong>ati<strong>on</strong> <strong>of</strong> quality parameters<br />

Sampl<strong>in</strong>g and analysis<br />

Grab samples have been taken 6 times between June 2004 and March 2006 from the effluents<br />

<strong>of</strong> the CWs. Dur<strong>in</strong>g the first three sampl<strong>in</strong>g rounds most <strong>of</strong> the wastewater parameters were<br />

analysed directly <strong>on</strong> spot with field test<strong>in</strong>g equipment. Due to problems <strong>of</strong> transport<strong>in</strong>g the<br />

test<strong>in</strong>g equipment by bus, for the last three rounds the majority <strong>of</strong> parameters were analysed<br />

<strong>in</strong> the laboratory <strong>of</strong> the Nati<strong>on</strong>al <strong>Water</strong> and Sewage Corporati<strong>on</strong> (Quality C<strong>on</strong>trol<br />

Department; Central Public Laboratories) <strong>in</strong> Kampala.<br />

The follow<strong>in</strong>g physico-chemical parameters have been analysed: COD, BOD5, NH4-N, PO4-<br />

P, SO4-S, turbidity, pH-value, Electrical c<strong>on</strong>ductivity (EC) and temperature. Additi<strong>on</strong>ally the<br />

samples have been analysed for the follow<strong>in</strong>g heavy metals: cadmium, chromium, copper,<br />

lead, nickel, z<strong>in</strong>c.<br />

Ugandan Discharge Regulati<strong>on</strong><br />

For the results <strong>of</strong> the data collecti<strong>on</strong> the Standards for discharge <strong>of</strong> effluent and wastewater <strong>in</strong><br />

Uganda (Uganda Discharge Regulati<strong>on</strong>, 1999) were used as reference level. Table 1 shows<br />

the discharge limits c<strong>on</strong>sidered <strong>in</strong> this study:<br />

Table 1. The standards for discharge <strong>of</strong> effluent and wastewater <strong>in</strong> Uganda.<br />

___________________________________________________________________________<br />

26 <strong>IWA</strong> <str<strong>on</strong>g>Specialist</str<strong>on</strong>g> <str<strong>on</strong>g>Group</str<strong>on</strong>g> <strong>on</strong> <strong>Use</strong> <strong>of</strong> <strong>Macrophytes</strong> <strong>in</strong> <strong>Water</strong> Polluti<strong>on</strong> C<strong>on</strong>trol: Newsletter No. 37