C<strong>on</strong>structed wetlands are an attractive opti<strong>on</strong> for treatment <strong>of</strong> deic<strong>in</strong>g run<strong>of</strong>f, because when<br />
operated <strong>in</strong> a subsurface mode, the risk to airfield operati<strong>on</strong>s is m<strong>in</strong>imal and the systems<br />
require much less operati<strong>on</strong> & ma<strong>in</strong>tenance than c<strong>on</strong>venti<strong>on</strong>al systems.<br />
PILOT TESTING<br />
Pilot test<strong>in</strong>g was carried out at Campus D‘Alfred <strong>of</strong> the University <strong>of</strong> Guelph <strong>in</strong> Ontario,<br />
Canada. . The tests were carried out <strong>in</strong>doors <strong>in</strong> 1 m 3 vessels c<strong>on</strong>figured as mix<strong>in</strong>g tanks<br />
(c<strong>on</strong>ta<strong>in</strong><strong>in</strong>g mixers and heaters), open aerated bas<strong>in</strong>s (AB cells, simulat<strong>in</strong>g aerated tanks and<br />
c<strong>on</strong>ta<strong>in</strong><strong>in</strong>g f<strong>in</strong>e bubble aerati<strong>on</strong> spargers), n<strong>on</strong>-aerated vertical subsurface flow (VSSF)<br />
c<strong>on</strong>structed wetland cells and aerated VSSF <strong>in</strong>tensified (IW) test cells. The wetland cells<br />
were vegetated with comm<strong>on</strong> reed (Phragmites sp.) taken from ditches near the test unit. Test<br />
runs were preceded by m<strong>on</strong>th-l<strong>on</strong>g calibrati<strong>on</strong> and acclimatizati<strong>on</strong> periods.<br />
The pilot facility was c<strong>on</strong>figured as a mix<strong>in</strong>g tank; two open-water AB cells; <strong>on</strong>e n<strong>on</strong>-aerated<br />
VSSF CW cell c<strong>on</strong>ta<strong>in</strong><strong>in</strong>g gravel 0.3 m deep and; and two aerated gravel-bed VSSF<br />
<strong>in</strong>tensified wetland cells (IW1 and IW2) c<strong>on</strong>ta<strong>in</strong><strong>in</strong>g gravel 0.8 m deep. There were two<br />
separate sets <strong>of</strong> cells which, after <strong>in</strong>itial calibrati<strong>on</strong> and acclimati<strong>on</strong> periods at room<br />
temperature, operated <strong>in</strong> parallel at the two design basis target temperatures. The set-up for<br />
high temperature operati<strong>on</strong>s c<strong>on</strong>sisted <strong>of</strong> a mix<strong>in</strong>g tank and an AB cell followed by parallel<br />
CW and IW cells. (These were c<strong>on</strong>sidered as two separate tra<strong>in</strong>s.) The set up for low<br />
temperature operati<strong>on</strong>s c<strong>on</strong>sisted <strong>of</strong> an AB Cell and <strong>on</strong>e IW cell <strong>in</strong> series. These latter two<br />
vessels were located <strong>in</strong>side a walk-<strong>in</strong> refrigerator at the Alfred Pilot Unit (Tra<strong>in</strong> 3). The <strong>in</strong>itial<br />
c<strong>on</strong>figurati<strong>on</strong> <strong>of</strong> the pilot facility is shown <strong>in</strong> Figure 1.<br />
SW from<br />
Storage Tanks<br />
ADF<br />
Mix<strong>in</strong>g Tank<br />
AB Cell<br />
Lo Temp<br />
AB Cell<br />
Hi Temp<br />
Walk-<strong>in</strong> Refrigerator<br />
IW Cell<br />
Lo Temp<br />
CW Cell<br />
Hi Temp<br />
IW Cell<br />
Hi Temp<br />
Figure 1. Pilot test facility schematic<br />
Tra<strong>in</strong> 3<br />
Tra<strong>in</strong> 2<br />
Tra<strong>in</strong> 1<br />
Results from the four test<strong>in</strong>g periods (Runs A, B, C, D) and the three process tra<strong>in</strong>s (Tra<strong>in</strong>s 1,<br />
2, 3) are summarized <strong>in</strong> Table 1 (Wallace et al., 2007).<br />
____________________________________________________________________________________________________<br />
<strong>IWA</strong> <str<strong>on</strong>g>Specialist</str<strong>on</strong>g> <str<strong>on</strong>g>Group</str<strong>on</strong>g> <strong>on</strong> <strong>Use</strong> <strong>of</strong> <strong>Macrophytes</strong> <strong>in</strong> <strong>Water</strong> Polluti<strong>on</strong> C<strong>on</strong>trol: Newsletter No. 38 37