Dur<strong>in</strong>g the 2010/2011 de-ic<strong>in</strong>g seas<strong>on</strong>, <strong>in</strong>fluent BOD5 c<strong>on</strong>centrati<strong>on</strong>s were <strong>in</strong> excess <strong>of</strong><br />
15,000 mg/L. Generally, the system had very low effluent values, which averaged 77 mg/L<br />
(based <strong>on</strong> a correlati<strong>on</strong> between <strong>on</strong>l<strong>in</strong>e total organic carb<strong>on</strong> measurements and laboratory<br />
BOD5 values), as shown <strong>in</strong> Figure 3.<br />
Figure 3. Influent and effluent BOD5 values for the <strong>in</strong>tensified wetland at Buffalo Niagara<br />
Internati<strong>on</strong>al Airport.<br />
The wetland system also experienced BOD5 load<strong>in</strong>gs well <strong>in</strong> excess <strong>of</strong> the orig<strong>in</strong>al design<br />
parameters. While the design was based <strong>on</strong> a BOD5 load<strong>in</strong>g rate <strong>of</strong> 4,500 kg/d, actual<br />
load<strong>in</strong>gs exceeded 20,000 kg/d. BOD5 removals rema<strong>in</strong>ed <strong>in</strong> the range <strong>of</strong> 90 to 100% (with<br />
an average removal rate <strong>of</strong> 98.3%), and reducti<strong>on</strong>s <strong>in</strong> treatment efficiency were <strong>on</strong>ly observed<br />
at the heaviest organic load<strong>in</strong>gs (Figure 4).<br />
Figure 4. BOD5 load<strong>in</strong>gs and treatment efficiency for the <strong>in</strong>tensified wetland at Buffalo<br />
Niagara Internati<strong>on</strong>al Airport<br />
____________________________________________________________________________________________________<br />
<strong>IWA</strong> <str<strong>on</strong>g>Specialist</str<strong>on</strong>g> <str<strong>on</strong>g>Group</str<strong>on</strong>g> <strong>on</strong> <strong>Use</strong> <strong>of</strong> <strong>Macrophytes</strong> <strong>in</strong> <strong>Water</strong> Polluti<strong>on</strong> C<strong>on</strong>trol: Newsletter No. 38 41