to the flag table (Figure 25). The Axi-Path is not a collinear<br />
system, and errors <strong>of</strong>ten occur when the clinician attempts<br />
to determine the THA. If a recording system is not collinear<br />
and rectilinear, the clinician is likely to mark the inaccurate<br />
hinge points on the skin.<br />
Figure 24 Nasion relator cannot<br />
move along the horizontal part <strong>of</strong> the bow.<br />
Figure 25 When the lower frame is placed, the<br />
stylus may not be perpendicular to the flag table.<br />
The following experiment can be used to determine the<br />
magnitude <strong>of</strong> measurement error. The experiment is set up so<br />
that the measurement shows the right condyle 5 mm forward<br />
<strong>of</strong> its actual position. For purposes <strong>of</strong> illustration, the situation<br />
is assumed to be noncollinear (Figure 26).<br />
Figure 26 Supposition. Right condyle moved 5 mm forward.<br />
The new hinge axis diverges from the original hinge axis<br />
as it goes farther from the anatomic structure (Figure 27).<br />
Figure 27 New hinge axis passing through<br />
newly positioned condyle.<br />
The right recording stylus is placed at the new hinge<br />
point on the flag table (Figure 28).<br />