1.3.05.01 CXI Room Temperature Environment<br />

This cell of the <strong>WBS</strong> identifies all required engineering, design, documentation,<br />

procurement, fabrication, assembly and testing efforts associated with room temperature<br />

sample chambers, an Ion time-of-flight detector, precision instrument stands and a detector<br />

stage.<br />

1.3.05.01.01 CXI Sample Chambers and Ion T<strong>OF</strong><br />

This cell of the <strong>WBS</strong> identifies all required engineering, design, documentation,<br />

procurement, fabrication, assembly and testing efforts associated with the CXI Sample<br />

Chambers (0.1 micron and 0.1 micron) and the ion time-of-flight mass spectrometer. Each<br />

CXI Sample Chamber will include an interface to the Coherent Imaging Injector, aperture<br />

raster stages and a sample raster stage with 2-axis rotation, as well as vacuum equipment<br />

to maintain and monitor the high vacuum of each chamber. The ion T<strong>OF</strong> will sample ions<br />

created at the interaction region and be mounted on the sample chamber. A single high<br />

resolution sample viewing system is also captured in this <strong>WBS</strong>.<br />

1.3.05.01.02 CXI Precision Instrument Stands<br />

This cell of the <strong>WBS</strong> identifies all required engineering, design, documentation,<br />

procurement, fabrication, assembly and testing efforts associated with two Precision<br />

Instrument Stands (0.1 micron and 1.0 micron) for the CXI instrument. Each stand will<br />

support, position and orient its respective Sample Chamber, the Coherent Imaging Injector<br />

and the Detector Stage. The Coherent Imaging Injector and the Detector Stage may be<br />

used with only one Sample Chamber/Precision Instrument Stand pair at any given time.<br />

1.3.05.01.03 CXI Detector Stage<br />

This cell of the <strong>WBS</strong> identifies all required engineering, design, documentation,<br />

procurement, fabrication, assembly and testing efforts associated with the Detector Stage<br />

which will support, position and orient the detector inside a vacuum vessel. The vacuum<br />

vessel and the necessary vacuum equipment to produce the high vacuum are also captured<br />

in this <strong>WBS</strong> element.