19.01.2013 Views

LS10-s / LS10-st - DG Flugzeugbau

LS10-s / LS10-st - DG Flugzeugbau

LS10-s / LS10-st - DG Flugzeugbau

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Flight manual <<strong>st</strong>rong>LS10</<strong>st</strong>rong>-s,-<strong>st</strong><br />

3.11 Loss of electrical power in flight or defective DEI-NT (only <<strong>st</strong>rong>LS10</<strong>st</strong>rong>-<strong>st</strong>)<br />

With such a defect there will be no OAT indication. Therefore only dump<br />

waterballa<strong>st</strong> at altitudes min. 1000 ft below the values of the flight<br />

conditions given in section 2.17 to prevent water freezing when dumping<br />

the balla<strong>st</strong>.<br />

3.11.1 With the engine retracted:.<br />

Continue flying as pure sailplane, engine extension will not be possible!<br />

3.11.2 With engine extended and not running<br />

The electrical fuel pump will not operate and therefore fuel to the engine is<br />

only supplied by the mechanical fuel pump.<br />

If the engine is fully extended, engine <strong>st</strong>art is possible. However, expect<br />

considerably higher altitude required for <strong>st</strong>arting due to poor fuel supply<br />

during <strong>st</strong>art, especially with a cold engine.<br />

Therefore avoid engine re-<strong>st</strong>art at low altitude when an electrical sy<strong>st</strong>em<br />

failure occurs.<br />

Search for a suitable field and perform a precautionary landing<br />

For landing with an extended engine refer to section 3.14.<br />

3.11.3 With engine extended and running<br />

Do not switch off the engine and proceed to next airfield. The maximum<br />

powerplant extended speed mu<strong>st</strong> not be exceeded during descent with<br />

engine running. Switch off the engine before landing if possible.<br />

For landing with an extended engine refer to section 3.14.<br />

Note: Without electrical power no information regarding engine-RPM, amount of<br />

fuel and OAT can be provided by the DEI-NT.<br />

Therefore observe maximum powerplant extended speed and be prepared<br />

for an engine <strong>st</strong>op when fuel tank is empty. Water in the balla<strong>st</strong> tanks mu<strong>st</strong><br />

be dumped before landing.<br />

3.12 Engine extension / retraction sy<strong>st</strong>em – Circuit breaker open<br />

The spindle drive is protected by an automatic circuit breaker in the control<br />

unit, which cannot be manually switched.<br />

If this circuit breaker opens due to a sy<strong>st</strong>em overload caused by spindle<br />

overload (e.g.aerodynamic loads) or mechanical blocking, this situation is<br />

indicated as shown below:<br />

- The DEI-NT display indicates „Failure: Spindle Fuse“. This<br />

indication disappears if the self set-back sy<strong>st</strong>em of the circuit breaker<br />

operates. Further it can be removed by pushing the selector knob.<br />

- The DEI-NT display indicates “F” in the center, upper right section<br />

until circuit breaker has automatically been closed. The automatically<br />

self set back process of the circuit breaker may take up to 5 seconds.<br />

- At the same time the engine control changes into manual mode.<br />

Issued: October 2009 EASA app. 3.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!