3. AUTOMATIC SAFETY FUNCTION<br />

POWER FAILURE<br />

After a short power failure the operating functions<br />

that were set before the power failure are continued.<br />

ON mode (manual operation). The control switches<br />

to the ST (Start Phase) and the unit then re-runs in<br />

ON operation.<br />

TM mode (automatic operation). The control<br />

switches to the ST (Start Phase) and the unit then<br />

re-runs in TM operation.<br />

SB mode (operational readiness, standby<br />

operation). After two seconds the control re-runs in<br />

the SB operation.<br />

On power failure a small amount of smoke may be<br />

emitted. This does not last for more than three to<br />

five minutes and does not represent a safety risks.<br />

OVERHEATING<br />

A temperature safety switch (STL) switches the<br />

stove off automatically if it overheats.<br />

A taking-out-of-service program (cleaning, follow-up<br />

phase) is performed. The stove must be restarted<br />

depending on the pre-set mode.<br />

CAUTION: If overheating has occurred then<br />

maintenance or cleaning work must be carried out.<br />

LOW TEMPERATURE SWITCH OFF<br />

If the stove cools down below a minimum<br />

temperature, then the stove will switch off. This<br />

switch off can also occur if pre-heating is too slow.<br />