Operating Instructions TURBOMAT TM 150 / 220 - Econergy Ltd
Operating Instructions TURBOMAT TM 150 / 220 - Econergy Ltd
Operating Instructions TURBOMAT TM 150 / 220 - Econergy Ltd
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Modes<br />
Mode Functions<br />
Winter operation The boiler controls the heating and domestic hot water heating according to the timed<br />
program settings. No decrease in output � The boiler remains at temperature.<br />
Summer operation<br />
Systems without storage<br />
The boiler only controls the domestic hot water heating according to the timed program<br />
settings. No decrease in output �The boiler switches off.<br />
Summer (oil) operation Waste-wood System, Black-pot, Boiler � The boiler is heated by the black-pot.<br />
Transitional operation<br />
Systems without storage<br />
Transitional operation<br />
Systems with stores<br />
NOTE: Systems with stores �<br />
Always select "Transitional<br />
Operation"<br />
Heating for special occasions<br />
Chimney sweep<br />
The boiler produces heat during the set heating phases (parameter menu "boiler<br />
times") (in the morning or the evening, for example). Heating and domestic hot water<br />
heating are regulated according to the set times (heating times, boiler loading). No<br />
decrease in output � Boiler goes to standby. The boiler switches off at the end of the<br />
heating phase.<br />
The boiler switches on during the set store loading times as needed, until the store is<br />
fully loaded�The boiler then switches off.<br />
The boiler switches off at the end of the store loading times, even if the store is not fully<br />
loaded.<br />
NOTE: Make the time window large enough (00:00 to 24:00 hours means: as soon as<br />
the need for heat arises, the boiler loads the store).<br />
The boiler switches on for four hours, the controller is set to "Party Switching,"<br />
domestic water heating is active.<br />
(Starts after pressing and holding the start key (I) for 5 seconds).<br />
The boiler runs for half an hour at full load (all stirrers are opened); then the control unit<br />
switches over to normal heating operation.<br />
(Starts after pressing and holding the "Back" key for 5 seconds; the program can<br />
be ended by pressing the STOP (O) key).<br />
Firewood operation This mode is for firewood-EMERGENCY-operation. The fuel feeding system is not<br />
operational.<br />
Switched off If you press the 0 key, the boiler will switch off according to the shut-down routine. The<br />
system now only regulates the connected heating components<br />
NOTE:<br />
For systems with stores, always select "Transitional Operation"<br />
20 B0310003 Edition 2003