Set boiler<br />
In the "SET" operator menu, parameters and values can be modified. In order to avoid unnecessarily operating the heating<br />
system under a full load, the loading times can be set on a timer for hot water preparation:<br />
for example, the boiler loading process should begin tomorrow before the start of the heating phase.<br />
The parameters "BEGIN and END the loading process" only appear if no storage tank was configured (See system<br />
schematics)<br />
Boiler ... ← Desired boiler temperature 55°←<br />
There is only a<br />
display if there<br />
is no store<br />
Set heating<br />
Reload if boiler under 45°←<br />
When the set temperature is reached in the boiler, the boiler loading<br />
pump disengages.<br />
Reloading of the boiler is authorized when the boiler temperature is<br />
below this temperature.<br />
Start of the first loading session 03:00← Start of the authorization for the first boiler loading session<br />
End of the first loading session 05:00← End of the authorization for the first boiler loading session<br />
Start of the second loading session 14:00← Start of the authorization for the second boiler loading session<br />
End of the second loading session 16:00← End of the authorization for the second boiler loading session<br />
In the "SET" operator menu, the heating program's parameters and values can be modified.<br />
It is possible to control two heating circuits<br />
(NOTE: It is not possible in the standard delivery configuration, but it is optional to buy).<br />
The heating phases represent the start and end of the increased heating demand in the course of one day.<br />
Each day can be given individual heating times (seven different heating times with two heating phases each), or the same<br />
heating times can be used on different days.<br />
This setting is made in the weekly program submenu.<br />
What's more, the room temperature desired value can be set to the heating or drawdown phase.<br />
Heating circuit 1... ← Weekly program<br />
M, Tu, W, Th, F, Sa, Su<br />
1 1 3 1 1 2 5<br />
Heating prog. Heating prog. 1<br />
Heating prog. 2 - 7<br />
Heating phase 1<br />
Start 06.00<br />
End 22:00<br />
Heating phase 2<br />
Start 24:00<br />
End 24:00<br />
Room temperature desired value 20°←<br />
Room temp. desired value<br />
in cool down mode 16°←<br />
For heating circuit 1, heating time programs 1-7 are<br />
assigned to the days of the week.<br />
Room temperature desired value during the heating phase<br />
� is only visible with the remote control.<br />
Room temperature desired value during the drawdown<br />
phase<br />
� is only visible with the remote control.<br />
Heating circuit 2... ← Programming as in heating circuit 1<br />
Heating program 1<br />
Heating program 2<br />
Heating program 3<br />
Heating program 4<br />
Heating program 5<br />
Heating program 6<br />
Heating program 7<br />
Start<br />
1. heating phase<br />
End<br />
1. heating phase<br />
Start<br />
2. heating phase<br />
End<br />
2. heating phase<br />
22 B0310003 Edition 2003