Technical Specifications<br />

H5<br />

H2<br />

8 9<br />

10<br />

B2<br />

Waste-wood Boiler Turbomat <strong>150</strong> / <strong>220</strong><br />

Rated heat output kW <strong>150</strong> 200<br />

Permissible working over-pressure bar 3 3<br />

Permissible outfeed temperature °C 95 95<br />

Minimum return feed temperature °C 55 55<br />

Boiler contents (water ) Liters 385<br />

Total boiler mass kg 1690<br />

Chamber/Heat-exchanger kg 940 / 750<br />

Upstream resistance (T=20K)<br />

Flow-through (∆T = 20K) m³/h 6.44 9.45<br />

Chimney Construction Data:<br />

Flue gas temperature °C 190 190<br />

Amount of fuel required at G50 W30 kg/h 50 67<br />

Flue gas mass flow at G50 W 20 Lambda=2 m³/h 664 885<br />

Necessary draught requirement at the chimney Pa 15/8 20/10<br />

Flue gas pipe diameter mm 200 250<br />

Structural Dimensions<br />

L Boiler depth mm 3230 3390<br />

B Boiler width mm 1210 1490<br />

H Boiler height 1) mm 1870 1870<br />

H1/H2 Outfeed/return feed height mm 1930 / 495 1930 / 495<br />

H3 Flue pipe height860<br />

H4 Height of stoker connection (with blow-back flap) mm 775 860<br />

H5 Height of induced draught unit mm 1970 1970<br />

H6 Height of flue gas return mm 2365 2365<br />

Outfeed/return feed connection DN 65 65<br />

Connection for thermal discharge safety device sleeve 1/2" 1/2"<br />

L1 Length of boiler mm 1710 1750<br />

L2 Length of induced draught fan mm 600 670<br />

L3 Depth from back wall to centre of stoker mm 1200 1240<br />

L4 Length of ash trolley for chamber ash removal mm 930 930<br />

B1 Width of ash trolley for chamber ash removal mm 550 550<br />

B2 Width of heat-exchanger<br />

B4<br />

12<br />

H1<br />

11<br />

5 6 7<br />

L4 L1 L2<br />

mm 870 570<br />

B3 Distance from centre of stoker to the boiler mm 630 630<br />

B4 Length of stoker (incl. gearing) mm 845 845<br />

Min. clearance height 1,950 mm Dimensions in mm, technical modifications are not authorized<br />

Min. clearance width 1,000 mm<br />

6 B0310003 Edition 2003<br />

H3<br />

3<br />

1 2<br />

1 ..Conveyor grate 5 ..Upper cleanout port door 9 ..Outfeed<br />

2 ..Ash rake 6 ..Upright heat-exchanger 10 ..Return feed<br />

3 ..Stoker screw 7 ..Induced draught fan 11 ..Ash trolley<br />

4 ..Combustion chamber door 8 ..Combustion air blower fan 12 ..Ashcan<br />