20. Skylight, Hatch <strong>and</strong> Smoke Vent Curbs<br />

Double dome skylight<br />

shown<br />

Wood curb, 2"x10" min.<br />

(factory curbs optional)<br />

Cant strip,<br />

set in bitumen or nailed<br />

Wood blocking secured to<br />

deck with appropriate<br />

fasteners, match<br />

the insulation thickness<br />

2" wood nailer<br />

,<br />

,,<br />

,<br />

,,<br />

,,<br />

4" min.<br />

,,<br />

21. Roof Top Air H<strong>and</strong>ling Units<br />

Metal frame, 16 gauge min.<br />

Curb insulation<br />

Cant strip set in bitumen<br />

or nailed<br />

Wood blocking<br />

fastened to deck,<br />

match insulation thickness<br />

Alternate frame support<br />

for heavy units.<br />

,,<br />

, ,,<br />

, ,, ,<br />

4" min.<br />

Extruded aluminum frame<br />

with weep holes<br />

Metal counterflashing<br />

to accommodate specific<br />

curb situation, with<br />

fasteners 8" o.c.<br />

Skylight anchors as specified<br />

Fasteners approx. 8" o.c.<br />

at base flashing<br />

Modified bitumen base<br />

flashing with 8" minimin<br />

height above roof surface<br />

Modified bitumen or asphalt<br />

bleed out at edge<br />

<strong>BITEC</strong> modified bitumen<br />

membrane with optional<br />

coating or surfacing. Extend<br />

4" min. above cant<br />

Base sheet or modified<br />

bitumen base as required,<br />

extend 2" min. above cant<br />

Roof insulation<br />

Seal strip or sealant<br />

Counterflashing fastened<br />

approx. 18" o.c. with a<br />

minimum of 3 per side<br />

<strong>BITEC</strong> modified bitumen base<br />

flashing with 8" min. height<br />

above roof surface<br />

Fasteners approx. 8" o.c.<br />

with a minimum of<br />

2 each side<br />

<strong>BITEC</strong> modified bitumen field<br />

membrane with optional<br />

coating or surfacing. 8" min.<br />

height above roof surface.<br />

Base sheet or modified<br />

bitumen base as required,<br />

extend 2" min. above cant<br />

,, Roof insulation<br />

47<br />

Rounded<br />

corners<br />

Modified bitumen<br />

or asphalt bleed<br />

out at edges<br />