B U R - M O D S Y S T E M S<br />

INSTALLATION PARAMETERS<br />

SECTION 1.00<br />

INSULATION<br />

In all cases a minimum of 1 ⁄ 2"<br />

thick perlite or high density wood<br />

fiber board insulation will be<br />

installed as a buffering layer. Other<br />

insulations are acceptable for use<br />

within these systems provided the<br />

insulation manufacturer’s specifications<br />

<strong>and</strong> <strong>BITEC</strong>’s specifications<br />

are followed. See the General<br />

Requirements SECTION 6.02 of<br />

this manual.<br />

Insulation must be used with all<br />

systems unless its use has been<br />

waived by <strong>BITEC</strong>’s Technical<br />

Services Department.<br />

SECTION 2.00<br />

BASE SHEETS<br />

AND PLY SHEETS<br />

Unless otherwise specified all<br />

base <strong>and</strong> ply sheets will be<br />

installed using hot asphalt as per<br />

<strong>BITEC</strong>’s published requirements<br />

which determine the type of<br />

asphalt to be used, asphalt application<br />

rate, <strong>and</strong> asphalt application<br />

temperature. See the General<br />

Requirements SECTIONS 1.02,<br />

1.03 <strong>and</strong> 1.04 of this manual.<br />

Under no circumstances will any<br />

Type IV or Type VI Ply Sheet be<br />

mechanically attached. Under certain<br />

conditions, however, the G2<br />

base sheet called for in the schedule<br />

may be mechanically attached.<br />

Allowance for this must be preapproved<br />

by <strong>BITEC</strong>’s Technical<br />

Services Department. For parameters<br />

involving mechanically<br />

attaching G2 base sheets refer to<br />

SECTION 2.02, on pg.17 of this<br />

manual.<br />

According to The NRCA<br />

<strong>Roofing</strong> <strong>and</strong> Waterproofing<br />

Manual:<br />

“...plies shall be embedded<br />

into a fluid, continuous applica-<br />

tion of asphalt. The asphalt shall<br />

be applied in such a way that at<br />

no place will felt touch felt. All<br />

plies of felt shall be broomed into<br />

place as they are applied to aid<br />

in adhesion ...”<br />

SECTION 3.00<br />

CAP SHEET<br />

Cap sheet shall be installed as<br />

per specifications given in the<br />

General Requirements SECTIONS<br />

2.03 <strong>and</strong> 2.04, pgs.17-18 of this<br />

manual.<br />

SECTION 4.00<br />

SPECIFICATIONS<br />

AND DETAILS<br />

Primary consultation for this<br />

information shall come from this<br />

book, <strong>and</strong> The NRCA <strong>Roofing</strong> <strong>and</strong><br />

Waterproofing Manual.<br />

All applicable publications shall<br />

be consulted before work begins.<br />

Some details for BUR-MOD systems<br />

are included in the following<br />

section of this manual. These<br />

details are simply variations of the<br />

details used for modified bitumen<br />

systems.<br />

Typically, for BUR-MOD systems,<br />

all Modified <strong>Bitumen</strong> <strong>Details</strong><br />

may be adapted to be used with<br />

BUR-MOD Systems.<br />

This is generally accomplished<br />

by using the base <strong>and</strong>/or ply<br />

sheets in lieu of the base <strong>and</strong>/or<br />

interply membrane of the modified<br />

bitumen system.<br />

For any specific details not<br />

shown, contact <strong>BITEC</strong> Technical<br />

Services Dept. at (800) 535-8597.<br />

SECTION 5.00<br />

ACCEPTABLE<br />

BASE AND PLY SHEET<br />

Base sheet <strong>and</strong> ply sheet from<br />

the following companies are<br />

60<br />

acceptable for use within the<br />

<strong>BITEC</strong> Bur-Mod systems:<br />

1) <strong>BITEC</strong>, INC.<br />

2) TAMKO <strong>Roofing</strong> Prod., Inc.<br />

3) Black Warrior <strong>Roofing</strong>, Inc.<br />

4) Fields Corporation<br />

5) Johns Manville (Schuller)<br />

No other base or ply sheet shall<br />

be used other than those given<br />

above unless approval is granted<br />

from <strong>BITEC</strong>’s Technical Service<br />

Department.<br />

The above companies publish<br />

their compliance with st<strong>and</strong>ards for<br />

the products shown on the next<br />

page, Table 1.<br />

SECTION 6.00<br />

APPROVAL FOR USE<br />

OF BUR-MOD SYSTEMS<br />

AS A SUBSTITUTE FOR<br />

OUR STANDARD<br />

WARRANTY SYSTEMS<br />

Pre-approval by the Technical<br />

Services Department is necessary<br />

in order to obtain a warranty for<br />

these systems.<br />

All Warranty Requests must be<br />

submitted in a reasonable amount<br />

of time prior to the start of the project<br />

for pre-approval.<br />

As is always done with any<br />

extraordinary warranty scenario, a<br />

special warranty document is used.<br />

However, our st<strong>and</strong>ard Limited<br />

Insured <strong>Roofing</strong> Warranty is applicable<br />

for any of the following systems<br />

listed in Table 2, next page.<br />

SECTION 7.00<br />

SPECIFICATION<br />

NUMBERS<br />

Specification number format will<br />

remain virtually the same with the<br />

following changes shown in chart<br />

on the next page.