BUR<br />

MOD<br />

Exterior plywood on cleat or<br />

tapered blocking to provide shape<br />

Cant strip, securely nailed<br />

or set in bitumen<br />

Wood blocking, secured<br />

with appropriate fasteners,<br />

match insulation thickness<br />

,,<br />

,,,<br />

,,,,<br />

,,,<br />

,,<br />

24" max.<br />

Note: This detail should be used only where the<br />

deck is supported by the wall. An expansion joint<br />

detail should be used for non wall-supported deck. Contact<br />

<strong>BITEC</strong> Technical Services if building movement is a concern.<br />

BUR<br />

MOD<br />

7B. High Parapet Base Flashing at Masonry Walls<br />

Solid wood blocking<br />

Prime masonry surfaces<br />

Exterior siding, brick, etc.<br />

,,<br />

,,<br />

,,<br />

,,<br />

Note: This detail should be used only where the<br />

deck is supported by the wall. An expansion joint<br />

detail should be used for non wall-supported deck. Contact<br />

<strong>BITEC</strong> Technical Services if building movement is a concern.<br />

4" min.<br />

,,<br />

,<br />

Coping - Designed to meet FMRC<br />

1-49 requirements<br />

Wall flashing membrane<br />

Fasteners approx. 18" o.c. at coping<br />

Fasteners 8" o.c.<br />

Sealant<br />

Termination bar<br />

Counterflashing<br />

<strong>BITEC</strong> base flashing membrane,<br />

extend 2" minimum up under wall<br />

flashing membrane<br />

Fasteners 8" o.c. above base sheet<br />

<strong>BITEC</strong> modified bitumen<br />

membrane with opt. surfacing or<br />

coating, extend 4" min. above cant<br />

Modified bitumen or asphalt bleed out<br />

at edge of base flashing<br />

1st <strong>and</strong> 2nd ply as required, fully<br />

adhered, extend 2" min. above the<br />

cant. Set in hot asphalt.<br />

7C. Multi-Ply Base Flashing at Masonry Parapets<br />

Wall flashing membrane<br />

Interply membrane(s)<br />

Exterior plywood on cleat or<br />

tapered blocking to<br />

provide shape<br />

Solid wood blocking<br />

Prime masonry surfaces<br />

Exterior siding, brick, etc.<br />

(masonry wall<br />

construction shown)<br />

Cant strip, securely nailed<br />

or set in bitumen<br />

Wood blocking, secured with<br />

appropriate fasteners, match<br />

insulation thickness<br />

24"<br />

max.<br />

67<br />

4" min.<br />

For 10 or 12 Yr. Warranty Only<br />

Coping - Designed to meet FMRC<br />

1-49 requirements<br />

Fasteners approx. 18" o.c. at coping<br />

Fasteners 8" o.c.<br />

Sealant<br />

Termination bar<br />

Counterflashing<br />

<strong>BITEC</strong> base flashing membrane,<br />

extend 2" up under wall flashing membrane<br />

<strong>BITEC</strong> base flashing interply membrane,<br />

extend 2" min. up under the next membrane<br />

Fasteners 8" o.c. above the base sheet<br />

<strong>BITEC</strong> modified bitumen membrane with<br />

optional surfacing or coating, extend 4"<br />

minimum above cant<br />

Modified bitumen or asphalt bleed out<br />

at edge of base flashing<br />

One or two pies of Type IV or Type VI<br />

interply felts set in hot asphalt; extend to 4"<br />

above the cant<br />

Base sheet <strong>and</strong>/or 1st ply as required, fully<br />

adhered, extend 2" min. above the cant<br />

Required for 15 & 20 Yr. Warranty<br />

B U R - M O D S Y S T E M S