PAGE 40 OPTIONAL EQUIPMENT (CONTINUED)<br />
9 Remove the regulator from the front of the gas control valve. Replace with the propane regulator,<br />
using the new gasket and screws included with the regulator. NOTE: Leak test this area after the<br />
heater is installed, gas is connected, and the main burner is lit.<br />
Align the regulator<br />
gasket so it is flat<br />
and the two tabs fit<br />
through the two<br />
holes on the<br />
gasket.<br />
T<br />
ON<br />
O<br />
L<br />
PI<br />
OFF<br />
PILOT ADJ<br />
NOTE: These holes strip<br />
easily. Use a hand<br />
screwdriver and tighten<br />
each screw evenly.<br />
VENT<br />
HI<br />
LO<br />
Regulator Gasket<br />
NOTE: use the new gasket<br />
included with the regulator.<br />
These screws hold the<br />
regulator in place.<br />
NOTE: use the new<br />
screws included with<br />
the regulator.<br />
Phillips<br />
Screwdriver<br />
LP (propane) regulators have a<br />
11.0 2.8 stamped here.<br />
10 Place the included propane label over the natural gas label on top of the gas control valve.<br />
THIS CONTROL<br />
HAS BEEN<br />
CONVERTED TO<br />
LP<br />
11 Make the gas line connection, start the heater and thoroughly leak-test all gas connections<br />
and the regulator. Check the pilot. Adjust if necessary.<br />
To adjust the pilot flame,<br />
remove the cover screw<br />
and gasket and turn the<br />
needle valve (NOTE: if<br />
the needle valve is totally<br />
unscrewed, gas will come<br />
out of this port).<br />
Clockwise lowers the<br />
flame while counterclockwise<br />
raises it.<br />
Replace the cover screw<br />
and gasket.<br />
T<br />
ON<br />
O<br />
Cover Screw Gasket<br />
Standard<br />
Screwdriver<br />
L<br />
PI<br />
PILOT ADJ<br />
OFF<br />
��<br />
Needle Valve<br />
Micro (1/16”)<br />
Standard<br />
Screwdriver<br />
Cover Screw<br />
The pilot flame must contact the thermocouple and<br />
thermopile (see the illustration below). Adjust the pilot up or<br />
down as necessary.<br />
VENT<br />
HI<br />
LO