PAGE 40 OPTIONAL EQUIPMENT (CONTINUED)<br />

9 Remove the regulator from the front of the gas control valve. Replace with the propane regulator,<br />

using the new gasket and screws included with the regulator. NOTE: Leak test this area after the<br />

heater is installed, gas is connected, and the main burner is lit.<br />

Align the regulator<br />

gasket so it is flat<br />

and the two tabs fit<br />

through the two<br />

holes on the<br />

gasket.<br />

T<br />

ON<br />

O<br />

L<br />

PI<br />

OFF<br />

PILOT ADJ<br />

NOTE: These holes strip<br />

easily. Use a hand<br />

screwdriver and tighten<br />

each screw evenly.<br />

VENT<br />

HI<br />

LO<br />

Regulator Gasket<br />

NOTE: use the new gasket<br />

included with the regulator.<br />

These screws hold the<br />

regulator in place.<br />

NOTE: use the new<br />

screws included with<br />

the regulator.<br />

Phillips<br />

Screwdriver<br />

LP (propane) regulators have a<br />

11.0 2.8 stamped here.<br />

10 Place the included propane label over the natural gas label on top of the gas control valve.<br />

THIS CONTROL<br />

HAS BEEN<br />

CONVERTED TO<br />

LP<br />

11 Make the gas line connection, start the heater and thoroughly leak-test all gas connections<br />

and the regulator. Check the pilot. Adjust if necessary.<br />

To adjust the pilot flame,<br />

remove the cover screw<br />

and gasket and turn the<br />

needle valve (NOTE: if<br />

the needle valve is totally<br />

unscrewed, gas will come<br />

out of this port).<br />

Clockwise lowers the<br />

flame while counterclockwise<br />

raises it.<br />

Replace the cover screw<br />

and gasket.<br />

T<br />

ON<br />

O<br />

Cover Screw Gasket<br />

Standard<br />

Screwdriver<br />

L<br />

PI<br />

PILOT ADJ<br />

OFF<br />

��<br />

Needle Valve<br />

Micro (1/16”)<br />

Standard<br />

Screwdriver<br />

Cover Screw<br />

The pilot flame must contact the thermocouple and<br />

thermopile (see the illustration below). Adjust the pilot up or<br />

down as necessary.<br />

VENT<br />

HI<br />

LO