366<br />

TECHNICAL DATA<br />

<strong>Alpha</strong> <strong>Wire</strong> INDUSTRIAL SERIES – SERIES F<br />

HIGH PERFORMANCE, FLEXIBLE AUTOMOTIVE CONTROL CABLE<br />

Order from <strong>Cuny</strong> & <strong>Guerber</strong> <strong>Inc</strong>., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz<br />

1.0<br />

PRODUCT SPECIFICATIONS<br />

1.1 Finely stranded bare copper conductor per ASTM B-3<br />

1.2 Conductor size: 18 AWG through 8 AWG, inclusive<br />

1.3 Insulation: Premium lubricated polyvinylchloride/nylon<br />

insulated conductors<br />

1.4 Color Code:<br />

Red insulated conductors with black numbers for AC circuits<br />

operating at less than line voltage<br />

Blue insulated conductors with white numbers for DC circuits<br />

operating at less than line voltage<br />

Black insulated conductors with white numbers for AC circuits<br />

operating at less than line voltage<br />

1.5 Conductor Styles:<br />

UL Type TFFN, THHN<br />

CSA AWM I/II A/B 90°C<br />

1.6 Cable Styles:<br />

UL Type TC-ER<br />

UL Type PLTC, Open Wiring, Sunlight Resistant<br />

UL MTW<br />

Oil Res. I/II<br />

UL Sunlight Resistant<br />

CSA AWM I/II A/B 600 Volt FT-4<br />

1.7 Jacket:<br />

Oil Resistant Thermoplastic Elastomer<br />

Available in black<br />

ENGINEERING SPECIFICATION<br />

Cable shall be <strong>Alpha</strong> <strong>Wire</strong> <strong>Company</strong> <strong>Alpha</strong> <strong>Wire</strong> INDUSTRIAL SERIES – SERIES F High Performance, Flexible Automotive Control<br />

Cable. Manufactured from finely stranded bare copper conductors in accordance with ASTM B-3, conductors shall be insulated with a premium grade<br />

of polyvinylchloride/nylon, which meets the flame test requirements of UL VW-1. Conductor insulation shall comply with UL Standard 62, Type TFFN,<br />

THHN Oil Res. I & II as well as CSA AWM I/II A/B FT-4. Red insulated conductors shall be numbered with black print for AC circuits operating at<br />

less than line voltage. Blue insulated conductors shall be numbered with white print for DC circuits operating at less than line voltage. Black<br />

insulated conductors shall be numbered with white print for AC circuits operating at less than line voltage. One green/yellow insulated grounding<br />

conductor and one neutral conductor shall be included and found in the outermost layer of the core. The neutral conductor shall be insulated with a<br />

white compound and red stripe for cores with red insulated conductors or a blue stripe for cores with blue insulated conductors and a white/black<br />

stripe for black core cable designs.<br />

Jacketing shall be of a specially formulated, oil resistant thermoplastic elastomer complying with the Standards of UL and CSA as well as being<br />

compliant with the requirements of CE-LVD.<br />

Complete cables shall be in compliance with the following certifying agencies standards:<br />

■ UL Standard 1277, Type TC-ER - 600 Volt ■ UL Standard 66, Type TFFN - THHN Oil Res. I/II<br />

■ Standard 13, Type PLTC - 300 Volt, Open <strong>Wire</strong> ■ CSA AWM I/II A/B 600 Volt FT-4<br />

■ Standard 13, Open <strong>Wire</strong> ■ CE - Low Voltage Directive 73/68/EEC Amendment 93/68/EEC<br />

■ Standard 13, Sunlight Resistant<br />

2.0<br />

PERFORMANCE<br />

2.1 Extended Flex Life<br />

2.2 Reduced Cable Cost<br />

2.3 Oil Resistant Construction<br />

2.4 High Level of Abrasion Resistance<br />

2.5 UL Listed, CSA Certified & Marked<br />

3.0<br />

APPLICATIONS<br />

3.1 Flexible Factory Equipment Interconnections<br />

3.2 Flexible Cables for Industrial Robot Actuator Arms<br />

3.3 Flexible Machine Tool Wiring<br />

3.4 Flexible Cables in Automotive Assembly Equipment<br />

3.5 Flexing Cables in Conveyor Systems<br />

3.6 Flexible Gantry Crane Cable<br />

3.7 Flexible Cables for Automated Storage/Retrieval Systems<br />

3.8 Flexible Cables for Use in Automated Dispensing/Packaging<br />

Equipment<br />

3.9 Flexible Cables for Use in Automated Inspection Equipment<br />

4.0<br />

4.1<br />

JACKET TEST DATA<br />

Property Test Method Standard<br />

Durometer Hardness ASTM D-2240 80/70<br />

Tensile Strength, psi ASTM D-412 1900<br />

Elongation, % ASTM D-412 360<br />

Oxygen Index ASTM D-2863 34<br />

Specific Gravity ASTM D-792 1.44<br />

4.2 Flame Retardancy<br />

UL 70,000 Btu Vertical Flame Test<br />

CSA FT-4 Flame Test<br />

Toll Free: 1-800-52 ALPHA • Telephone: 908-925-8000 • Fax: 908-925-6923 Web Site: www.alphawire.com<br />

Europe/UK Telephone: +44 (0) 1932 772422 • Europe/UK Fax: +44 (0) 1932 772433 Email: info@alphawire.com