XTRA•GUARD ® 1<br />

MULTICONDUCTOR, FOIL SHIELD<br />

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE<br />

Order from <strong>Cuny</strong> & <strong>Guerber</strong> <strong>Inc</strong>., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz<br />

UL TYPE CM, AWM 2464<br />

CSA CMG FT4<br />

300 VOLT<br />

CHOOSE XTRA •GUARD 1FOR:<br />

■ Unsurpassed Flame and Moisture Resistance<br />

■ Fast, Easy Stripping of Insulation and Jacket<br />

■ UL Recognition, UL Listing and CSA Certification<br />

■ Flexible Cable Routing Requirements<br />

XTRA •GUARD 1APPLICATIONS:<br />

■ EIA RS 232C Interface (24, 22 AWG)<br />

■ High Technology Applications in Controlled Environments<br />

■ Medical Electronics<br />

■ Point-Of-Sale Equipment<br />

■ Computer Peripherals<br />

■ Industrial Process Controls<br />

CHARACTERISTICS<br />

OPERATING TEMPERATURE:<br />

■ –20°C to 80°C – AWM<br />

■ –20°C to 75°C – CM<br />

VOLTAGE RATING:<br />

■ 300 Volt<br />

COLOR DESCRIPTION:<br />

■ Color Code: 24, 22 AWG Chart E Page 375,<br />

■ 20 AWG Chart D Page 375<br />

■ Jacket Colors: Gray, Black<br />

PRODUCT DESCRIPTION:<br />

■ Conductor: Stranded Tinned Copper<br />

■ Insulation: Color-Coded Premium PVC<br />

■ Shield: Aluminum/Polyester Foil Facing In with<br />

Stranded Tinned Copper Drain <strong>Wire</strong> Equal in Size to<br />

Insulated Conductors of Cable<br />

■ Nylon Rip Cord for Ease of Jacket Stripping<br />

■ Jacket: Premium PVC<br />

SPECIFICATIONS<br />

■ UL Type CM, AWM Style 2464<br />

■ CSA CMG FT4<br />

■ Passes UL VW-1 Flame Test<br />

■ Passes CSA FT4 Flame Test<br />

®<br />

AVAILABILITY<br />

■ In Stock: Gray 100 ft (30,5m), 500 ft (152m) and<br />

1000 ft (305m) put-ups<br />

■ Made-To-Order: Black, 1000 ft (305m) minimum<br />

▲ Also available in Gray 328 ft (100m)<br />

FIT® TUBING RECOMMENDATION<br />

FIT®-221 – General Purpose, Irradiated Polyolefin (See Page 114 for Product Specifications)<br />

FIT®-321 – Medium Wall, Adhesive Lined, Irradiated Polyolefin (See Page 121 for Product Specifications)<br />

24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)<br />

XTRA•GUARD 1 No. of Jacket Thickness Nominal Diameter<br />

Part No. Cond. <strong>Inc</strong>hes mm <strong>Inc</strong>hes mm<br />

▲ 5092C 2 0.032 0,81 0.16 4,1<br />

▲ 5093C 3 0.032 0,81 0.17 4,3<br />

▲ 5094C 4 0.032 0,81 0.18 4,5<br />

▲ 5096C 6 0.032 0,81 0.20 5,1<br />

▲ 5098C 8 0.032 0,81 0.22 5,6<br />

▲ 5100C 10 0.032 0,81 0.25 6,3<br />

▲ 5100/15C 15 0.032 0,81 0.27 6,9<br />

▲ 5100/20C 20 0.032 0,81 0.30 7,6<br />

▲ 5100/25C 25 0.032 0,81 0.33 8,3<br />

▲ 5100/30C 30 0.032 0,81 0.36 9,2<br />

▲ 5100/40C 40 0.032 0,81 0.40 10,2<br />

▲ 5100/50C 50 0.032 0,81 0.44 11,3<br />

▲ 5100/60C 60 0.032 0,81 0.47 11,9<br />

▲ 5100/70C 70 0.032 0,81 0.51 12,9<br />

22 AWG (0,35mm 2 ), 7/30 (7x0,25mm), Insulation Thickness: 0.010" (0,25mm)<br />

XTRA•GUARD 1 No. of Jacket Thickness Nominal Diameter<br />

Part No. Cond. <strong>Inc</strong>hes mm <strong>Inc</strong>hes mm<br />

● 5192C 2 0.032 0,81 0.18 4,6<br />

● 5193C 3 0.032 0,81 0.19 4,9<br />

● 5194C 4 0.032 0,81 0.20 5,1<br />

● 5196C 6 0.032 0,81 0.23 5,9<br />

● 5198C 8 0.032 0,81 0.25 6,4<br />

● 5199/10C 10 0.032 0,81 0.28 7,0<br />

● 5199/15C 15 0.032 0,81 0.31 7,9<br />

● 5199/20C 20 0.032 0,81 0.34 8,6<br />

● 5199/25C 25 0.032 0,81 0.38 9,7<br />

● 5199/30C 30 0.032 0,81 0.40 10,2<br />

● 5199/40C 40 0.032 0,81 0.45 11,5<br />

● 5199/50C 50 0.032 0,81 0.49 12,5<br />

● 5199/60C 60 0.032 0,81 0.53 13,5<br />

● 5199/70C 70 0.053 1,35 0.62 14,0<br />

20 AWG (0,56mm 2 ), 7/28 (7x0,32mm), Insulation Thickness: 0.017" (0,43mm)<br />

XTRA•GUARD 1 No. of Jacket Thickness Nominal Diameter<br />

Part No. Cond. <strong>Inc</strong>hes mm <strong>Inc</strong>hes mm<br />

● 5462C 2 0.032 0,81 0.21 5,4<br />

● 5463C 3 0.032 0,81 0.22 5,6<br />

● 5464C 4 0.032 0,81 0.24 6,1<br />

● 5466C 6 0.032 0,81 0.28 7,1<br />

● 5468C 8 0.032 0,81 0.31 7,9<br />

● 5470C 10 0.032 0,81 0.35 8,9<br />

● 5470/15C 15 0.032 0,81 0.41 10,4<br />

● 5470/20C 20 0.032 0,81 0.46 11,6<br />

● 5470/25C 25 0.032 0,81 0.50 12,7<br />

● 5470/30C 30 0.032 0,81 0.54 13,6<br />

● 5470/40C 40 0.053 1,35 0.65 16,4<br />

● 5470/50C 50 0.053 1,35 0.71 17,9<br />

Additional AWG sizes on next page<br />

FOR COMPLETE PRODUCT PERFORMANCE DATA, SEE TECHNICAL SECTION IN THE BACK OF THIS BOOK.<br />

Web Site: www.alphawire.com Toll Free: 1-800-52 ALPHA • Telephone: 908-925-8000 • Fax: 908-925-6923<br />

Email: info@alphawire.com Europe/UK Telephone: +44 (0) 1932 772422 • Europe/UK Fax: +44 (0) 1932 772433<br />