1.12 CONNECTIONS<br />

Instructions for use and maintenance <strong>LABRADOR</strong><br />

Water supply line to be provided:<br />

R1 2”<br />

Inlet water connection: minimum R 1”<br />

<strong>Wash</strong> water pressure: min. 4 - max 6 bar<br />

Compressed air inlet connection: R 1/2”<br />

Air pressure: 6 bar<br />

Attention<br />

Any type of work on the electrical system, even when<br />

only of a slight entity, must be carried out by professionally<br />

qualified persons using adequate instruments<br />

and tools.<br />

S t a n d a r d v o l t a g e a n d f r e q u e n c y :<br />

400 ± 10% V 50 Hz<br />

Power supply cable:<br />

5 x 16 mmq (400 V)<br />

Maximum absorbed power<br />

2 bay unit 13.4 kW<br />

3 bay unit 18 kW<br />

4 bay unit 20,6 kW<br />

5 bay unit 24.2 kW<br />

6 bay unit 27,8 kW<br />

Note: The maximum absorbed power is measured<br />

with all machine components in operation, i.e. bay<br />

lighting, token suction motors, compressor , separation<br />

tank pumps, high pressure pumps, osmotic water<br />

pump, softened water pump, water heater.<br />

1.12.1 INLET WATER QUALITY<br />

The regular performance of the washing plant is<br />

granted only if the feeding water complies with the<br />

following characteristics:<br />

PH 6-8 6-8<br />

Hardness (°F) < 30 < 50<br />

TDS salt content<br />

(mg/l) < 3000 < 1500<br />

total<br />

Turbidity max (NTU) 1 1<br />

Free chlorine (mg/l) - < 0.1<br />

Iron < 2 < 0.05<br />

If the water characteristics are not as espected, CEC-<br />

CATO SpA is however at your disposal to define and<br />

supply the most suitable treatment system to obtain<br />

the required water quality.<br />

1.13 OTHER FEATURES<br />

<strong>Wash</strong>ing section<br />

Water consumption, each bay:<br />

11 litres/minute<br />

Max gun nozzle delivery:<br />

11 litres/minute<br />

Temperature of the water at the nozzle:<br />

• approx. 12 °C with feeding from aqueduct/well.<br />

• approx. 45 °C with feeding from the heating system<br />

Pressure of the water at the nozzle:<br />

approx. 10 MP a (100 bar)<br />

Water heating section<br />

Heat generator thermal power:<br />

from 25 to 92 kW depending on the type of boiler.<br />

Granted hot water delivery:<br />

from 833-2554 l/h depending on the type of boiler.<br />

Maximum water exit temperature:<br />

55 °C.<br />

Maximum water exit pressure:<br />

0,6 MP a (6 bar).<br />