1.12 CONNECTIONS<br />
Instructions for use and maintenance <strong>LABRADOR</strong><br />
Water supply line to be provided:<br />
R1 2”<br />
Inlet water connection: minimum R 1”<br />
<strong>Wash</strong> water pressure: min. 4 - max 6 bar<br />
Compressed air inlet connection: R 1/2”<br />
Air pressure: 6 bar<br />
Attention<br />
Any type of work on the electrical system, even when<br />
only of a slight entity, must be carried out by professionally<br />
qualified persons using adequate instruments<br />
and tools.<br />
S t a n d a r d v o l t a g e a n d f r e q u e n c y :<br />
400 ± 10% V 50 Hz<br />
Power supply cable:<br />
5 x 16 mmq (400 V)<br />
Maximum absorbed power<br />
2 bay unit 13.4 kW<br />
3 bay unit 18 kW<br />
4 bay unit 20,6 kW<br />
5 bay unit 24.2 kW<br />
6 bay unit 27,8 kW<br />
Note: The maximum absorbed power is measured<br />
with all machine components in operation, i.e. bay<br />
lighting, token suction motors, compressor , separation<br />
tank pumps, high pressure pumps, osmotic water<br />
pump, softened water pump, water heater.<br />
1.12.1 INLET WATER QUALITY<br />
The regular performance of the washing plant is<br />
granted only if the feeding water complies with the<br />
following characteristics:<br />
PH 6-8 6-8<br />
Hardness (°F) < 30 < 50<br />
TDS salt content<br />
(mg/l) < 3000 < 1500<br />
total<br />
Turbidity max (NTU) 1 1<br />
Free chlorine (mg/l) - < 0.1<br />
Iron < 2 < 0.05<br />
If the water characteristics are not as espected, CEC-<br />
CATO SpA is however at your disposal to define and<br />
supply the most suitable treatment system to obtain<br />
the required water quality.<br />
1.13 OTHER FEATURES<br />
<strong>Wash</strong>ing section<br />
Water consumption, each bay:<br />
11 litres/minute<br />
Max gun nozzle delivery:<br />
11 litres/minute<br />
Temperature of the water at the nozzle:<br />
• approx. 12 °C with feeding from aqueduct/well.<br />
• approx. 45 °C with feeding from the heating system<br />
Pressure of the water at the nozzle:<br />
approx. 10 MP a (100 bar)<br />
Water heating section<br />
Heat generator thermal power:<br />
from 25 to 92 kW depending on the type of boiler.<br />
Granted hot water delivery:<br />
from 833-2554 l/h depending on the type of boiler.<br />
Maximum water exit temperature:<br />
55 °C.<br />
Maximum water exit pressure:<br />
0,6 MP a (6 bar).<br />
13