Instructions for use and maintenance <strong>LABRADOR</strong><br />
5.5.1 PROBLEMS ON THE WATER SOFTENER GROUP<br />
The unit does not regenerate the<br />
water<br />
� No power supply Check fuses and main switch<br />
� Timer faulty<br />
Hard water comes out of the unit<br />
Change the timer<br />
� No salt in the container Add salt<br />
� Clogged injector filter Clean the filter<br />
� Salt container filling flow is not Check the time to fill the salt container and clean the one-way valve<br />
enough.<br />
� Air leakage or falty water suction - Check the gasket and the pilot tube.<br />
in the salt container.<br />
- Check the submerged tube<br />
� Internal loss in the valve.<br />
Too high salt consumption<br />
- Replace the valve gasket, the cross elements or the piston.<br />
� Regeneration voulume adjustment<br />
too high<br />
Check the regeneration volume according to the water hardness.<br />
� Too much water in the salt Injector clogged - Foreign body in the brine valve, disassemble and clean<br />
container<br />
Pressure drop<br />
� Iron deposit in the pipes. Clean the pipes.<br />
� Iron deposit in the softener. Clean the valve and the resin bottles. Increase the regeneration frequency.<br />
� Softener inlet side clogged by Clean the valve.<br />
residues of works in the pipes<br />
Loss of resins at the exit to the<br />
sewage<br />
� Air in the water system. Check that the tank is not dry.<br />
Iron in the treated water<br />
� Resin exhausted. Check the first phase; the brine suction and the salt container filling. Increase the<br />
regeneration frequency.<br />
Too much water in the salt<br />
container<br />
� Brine suction valve clogged. Check the delivery regulator<br />
� Injector clogged. Clean the injector and the filter<br />
� Timer does not control the cycles. Change the timer<br />
� Foreign body in the brine valve. Replace the brine valve seat and clean the valve.<br />
� Foreign body in the one way Clean the valve.<br />
valve.<br />
� Power black out during filling of Check the power supply.<br />
the salt container.<br />
The unit does not draw-in the brine<br />
� Brine suction valve clogged. Clean the delivery regulator.<br />
� Injector clogged. Clean the injector.<br />
� Injector filter clogged. Clean the filter.<br />
� Too low pressure in the system. Increase the pressure in the system to 1,7 bar.<br />
� Valve internal leakage. Replace the gaskets, the cross elemenets and the piston assembly.<br />
� Air leakage or water suction - Check if the delivery pipe is broken.<br />
anomaly in the salt container.<br />
- Check the gasket and the pilot tube.<br />
- Check the submerged pipe.<br />
The valve regenerates without<br />
interruption<br />
Switch broken or in short circuit. Check wether the fault is in the switch or in the timer and replace the relevant item, or<br />
replace the complete control head.<br />
Loss towards the sewer<br />
� The valve does not carry out the<br />
program.<br />
Check the timer program and the valve positions. If the positions are not the correct<br />
ones, replace the complete control head.<br />
� Foreign body in the valve. Dismount the complete control head and check the valve inside in the different positions<br />
of regeneration.<br />
� Valve internal leakage. Replace the gaskets and the piston assembly.