Instructions for use and maintenance <strong>LABRADOR</strong><br />

5.5.1 PROBLEMS ON THE WATER SOFTENER GROUP<br />

The unit does not regenerate the<br />

water<br />

� No power supply Check fuses and main switch<br />

� Timer faulty<br />

Hard water comes out of the unit<br />

Change the timer<br />

� No salt in the container Add salt<br />

� Clogged injector filter Clean the filter<br />

� Salt container filling flow is not Check the time to fill the salt container and clean the one-way valve<br />

enough.<br />

� Air leakage or falty water suction - Check the gasket and the pilot tube.<br />

in the salt container.<br />

- Check the submerged tube<br />

� Internal loss in the valve.<br />

Too high salt consumption<br />

- Replace the valve gasket, the cross elements or the piston.<br />

� Regeneration voulume adjustment<br />

too high<br />

Check the regeneration volume according to the water hardness.<br />

� Too much water in the salt Injector clogged - Foreign body in the brine valve, disassemble and clean<br />

container<br />

Pressure drop<br />

� Iron deposit in the pipes. Clean the pipes.<br />

� Iron deposit in the softener. Clean the valve and the resin bottles. Increase the regeneration frequency.<br />

� Softener inlet side clogged by Clean the valve.<br />

residues of works in the pipes<br />

Loss of resins at the exit to the<br />

sewage<br />

� Air in the water system. Check that the tank is not dry.<br />

Iron in the treated water<br />

� Resin exhausted. Check the first phase; the brine suction and the salt container filling. Increase the<br />

regeneration frequency.<br />

Too much water in the salt<br />

container<br />

� Brine suction valve clogged. Check the delivery regulator<br />

� Injector clogged. Clean the injector and the filter<br />

� Timer does not control the cycles. Change the timer<br />

� Foreign body in the brine valve. Replace the brine valve seat and clean the valve.<br />

� Foreign body in the one way Clean the valve.<br />

valve.<br />

� Power black out during filling of Check the power supply.<br />

the salt container.<br />

The unit does not draw-in the brine<br />

� Brine suction valve clogged. Clean the delivery regulator.<br />

� Injector clogged. Clean the injector.<br />

� Injector filter clogged. Clean the filter.<br />

� Too low pressure in the system. Increase the pressure in the system to 1,7 bar.<br />

� Valve internal leakage. Replace the gaskets, the cross elemenets and the piston assembly.<br />

� Air leakage or water suction - Check if the delivery pipe is broken.<br />

anomaly in the salt container.<br />

- Check the gasket and the pilot tube.<br />

- Check the submerged pipe.<br />

The valve regenerates without<br />

interruption<br />

Switch broken or in short circuit. Check wether the fault is in the switch or in the timer and replace the relevant item, or<br />

replace the complete control head.<br />

Loss towards the sewer<br />

� The valve does not carry out the<br />

program.<br />

Check the timer program and the valve positions. If the positions are not the correct<br />

ones, replace the complete control head.<br />

� Foreign body in the valve. Dismount the complete control head and check the valve inside in the different positions<br />

of regeneration.<br />

� Valve internal leakage. Replace the gaskets and the piston assembly.