Stem extension sets according<br />
to the dvgW Publication gW 336<br />
definition Pipe Covering<br />
Definition of terms:<br />
GL = obturator linkage length,<br />
RD = pipe covering,<br />
GA = linkage departure point.<br />
This formula and the GA information enable the calculation of the<br />
stem extension length for the required pipe covering.<br />
GL = RD – 170 mm – GA<br />
After rearranging the formula it is also possible to calculate the pipe covering:<br />
RD = GL + 170 mm + GA<br />
Butterfly valves<br />
DN PN GA<br />
mm<br />
100 10 / 16 / 25 146<br />
Düker valves<br />
125 10 / 16 / 25 134<br />
150 10 / 16 / 25 121<br />
200 10 / 16 96<br />
200 25 150<br />
250 10 71<br />
250 16 / 25 126<br />
300 10 / 16 / 25 101<br />
350 10 / 16 75<br />
350 25 91<br />
400 10 50<br />
400 16 / 25 66<br />
450 10 / 16 / 25 41<br />
500 10 / 16 16<br />
500 25 141<br />
600 10 -34<br />
600 16 91<br />
600 25 296<br />
700 10 37<br />
700 16 / 25 242<br />
800 10 / 16 192<br />
800 25 94<br />
900 10 143<br />
900 16 45<br />
1000 10 89<br />
1000 16 / 25 49<br />
1200 10 -51<br />
Gate valves<br />
DN GA<br />
mm<br />
40 180<br />
50 200<br />
65 230<br />
80 224<br />
100 238<br />
125 260<br />
150 290<br />
200 350<br />
250 515<br />
300 565<br />
Service connection valves<br />
Service connection<br />
valve type 1004<br />
– 73 –<br />
DN<br />
GA<br />
mm<br />
25 115<br />
32 130<br />
40 127<br />
50 148<br />
Tapping valve TOP 236<br />
<strong>2012</strong> price list<br />
1. Resilient-Seated<br />
Gate Valves<br />
2. Service Connection<br />
Valves<br />
3. Hydrants<br />
4. Butterfly Valves<br />
5. Novo Plug-in System<br />
6. Accessories<br />
7. Pressure Pipe Fittings<br />
Flanged Pressure Pipes<br />
Thrust-Resistant Joints<br />
8. Pressure Pipe Fittings<br />
with Novo Socket<br />
9. Pressure Pipe Fittings<br />
for Plastic Pipelines