2.2.6 CONSTRUCTION SIZE 5 (<strong>VCB</strong> 400–460 TO –610)<br />
<strong>VCB</strong><br />
400-460<br />
Output motor side, at 400 V connecting voltage<br />
Recommended<br />
rated motor output<br />
Equipment continuous<br />
output<br />
Output current,<br />
effective<br />
Output voltage,<br />
effective<br />
1.2 / 1.5 for 60 s,<br />
Overload capacity -<br />
according to model<br />
P1 06/05 2-11<br />
<strong>VCB</strong><br />
400-570<br />
<strong>VCB</strong><br />
400-610<br />
P kW 250 315 355<br />
S kVA 318.7 395 422.6<br />
I A 460 570 610<br />
U V 3 x 0 ... mains voltage input<br />
1.2 for 60 s<br />
Protection short circuit / earth fault<br />
Rotary field frequency f Hz 0 ... 400, according to switching frequency<br />
Switching frequency f kHz 1 ... 4<br />
Connection bolt<br />
Input mains side<br />
- - M12<br />
Recommended<br />
wiring cross section<br />
A mm 2<br />
2 x 185 2 x 240<br />
Voltage U V 3 x 400 (-20%) ... 460 (+10%)<br />
Frequency f Hz 50 (-10%) ... 60 (+10%)<br />
Power factor cos φ - ~1 (Power factor of the fundamental)<br />
Efficiency (approx.) η % 98, at 2 kHz switching frequency<br />
Line fuses<br />
Mechanical<br />
- - external<br />
Dimensions WxHxD mm<br />
518x820x406 1)<br />
518x1095x406 2)<br />
518x1095x406<br />
Weight (approx.) m kg<br />
110 2)<br />
120 3)<br />
Protection class - - IP 20<br />
Installation type - - Vertical wall mounting<br />
Environmental conditions<br />
Dissipation, at<br />
2 kHz switching freq.<br />
P W 4840 5984 6399<br />
Min. air consumption Q m 3 /h 700 1) , 1200 2) 1200<br />
Coolant temperature Tn °C 0 ... 40, forced ventilation<br />
Storage temperature TL °C -25 ... +55<br />
Transport<br />
temperature<br />
TT °C -25 ... +70<br />
Relative humidity - % 15 ... 85, no condensation<br />
Power reduction<br />
see Chapter 3.3.1<br />
ΔP %<br />
120<br />
2.5%/K above 40 °C; Tmax=50 °C;<br />
5%/1000 m above 1000 m above sea level;<br />
hmax=4000m<br />
Options and accessories<br />
Line choke (u k=4%) - - external<br />
EMC filter - - external<br />
Brake chopper - - optional internal<br />
Digital control unit - - optional<br />
1) 2)<br />
overload capacity 1.2, overload capacity 1.5<br />
Internal fuses used<br />
Fuse for switching power supply 2 pcs. 1A6 / 500V super-quick-acting, 6.3 x 32 mm<br />
Fuse protection power supply cables and fan 5 pcs. 10A / 500V semi-time-lag,<br />
6.3 x 32 mm