Operating Instructions Part 1 VCB - Bonfiglioli USA
Operating Instructions Part 1 VCB - Bonfiglioli USA
Operating Instructions Part 1 VCB - Bonfiglioli USA
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
!<br />
Attention: The cut in the cabinet has to be 20 mm bigger (see drill pattern) than<br />
the height of the frequency inverter housing; otherwise it is impossible<br />
to pass the device through the cut.<br />
Assembling instruction feed-through model <strong>VCB</strong> 400-045 to -075 in<br />
construction size 2<br />
heat conducting<br />
sheet metal<br />
P1 06/05 3-6<br />
1.<br />
rear panel<br />
3.<br />
2.<br />
4.<br />
bracket<br />
bracket<br />
frequency inverter<br />
1. Screw the heat conducting sheet metal on the backside of the heat sink of the<br />
frequency inverter.<br />
2. Screw one bracket on the underside of the cut of the cabinet rear panel.<br />
3. Pass the frequency inverter with the heat sink through the cut and engage the<br />
slot at the underside to the bracket.<br />
4. Engage the 2 nd bracket at the slot on the upper side and screw the bracket at<br />
the cabinet.