!<br />

Attention: The cut in the cabinet has to be 20 mm bigger (see drill pattern) than<br />

the height of the frequency inverter housing; otherwise it is impossible<br />

to pass the device through the cut.<br />

Assembling instruction feed-through model <strong>VCB</strong> 400-045 to -075 in<br />

construction size 2<br />

heat conducting<br />

sheet metal<br />

P1 06/05 3-6<br />

1.<br />

rear panel<br />

3.<br />

2.<br />

4.<br />

bracket<br />

bracket<br />

frequency inverter<br />

1. Screw the heat conducting sheet metal on the backside of the heat sink of the<br />

frequency inverter.<br />

2. Screw one bracket on the underside of the cut of the cabinet rear panel.<br />

3. Pass the frequency inverter with the heat sink through the cut and engage the<br />

slot at the underside to the bracket.<br />

4. Engage the 2 nd bracket at the slot on the upper side and screw the bracket at<br />

the cabinet.