10.02.2013 Views

HUMIDITY / TEMPERATURE MEASUREMENT - Omni Instruments

HUMIDITY / TEMPERATURE MEASUREMENT - Omni Instruments

HUMIDITY / TEMPERATURE MEASUREMENT - Omni Instruments

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1<br />

<strong>HUMIDITY</strong> / <strong>TEMPERATURE</strong><br />

M E A S U R E M E N T<br />

2 0 0 2 / 2 0 0 3<br />

UK / Europe / USA Office<br />

Tel: +44 (0)8700 434040<br />

Fax: +44 (0)8700 434045<br />

E-mails - info@omniinstruments.co.uk<br />

East Kingsway Business Centre<br />

Mid Craigie Trading Estate<br />

Mid Craigie Road,Dundee DD4 7RH UK


Rotronic have been manufacturers of humidity instruments since 1967. Our products have been<br />

developed over the years to provide accurate and dependable measurements in a wide range of applications,<br />

at competitive prices, and with features which our customers appreciate. Throughout this<br />

catalogue, you will fi nd a range of units which solve the measurement requirements in almost any<br />

application.<br />

All products are developed and manufactured at our headquarters in Switzerland, where we maintain<br />

an ISO9001 quality system, as well as an accredited calibration laboratory, and a full repair facility.<br />

We have a worldwide network of subsidiary companies and distributors, who are highly trained<br />

to support the ROTRONIC product range.<br />

When you specify a ROTRONIC product, you can expect:<br />

ROTRONIC – The Company<br />

• High accuracy sensing technology.<br />

• Excellent long term measurement stability.<br />

• Sensors with a high resistance to condensation and chemical pollution.<br />

• Full calibration adjustment facilities.<br />

• Traceable humidity calibration standards.<br />

• Expert product support throughout the life of the product<br />

Many famous international organisations place their trust in ROTRONIC measurement systems, our<br />

customer list includes:<br />

SIEMENS DEUTSCHER WETTERDIENST NASA<br />

BARILLA HONEYWELL<br />

NOVARTIS INTEL ROCHE<br />

AGFA-GEVAERT NESTLÉ<br />

MÉTÉO FRANCE BAYER HOFFMAN-LA-ROCHE<br />

PROCTER & GAMBLE KNORR<br />

JOHNSON CONTROL PHILIP MORRIS HEWLETT PACKARD<br />

KODAK CLARIANT<br />

I<br />

N<br />

T<br />

R<br />

O<br />

D<br />

U<br />

C<br />

T<br />

I<br />

O<br />

N<br />

1


I<br />

N<br />

T<br />

R<br />

O<br />

D<br />

U<br />

C<br />

T<br />

I<br />

O<br />

N<br />

2<br />

ROTRONIC Technology<br />

The measurement of humidity is a complex science, and over many years we have continuously developed<br />

our products to provide higher precision, better long term stability and the features our customers<br />

demand. There are certain core technologies which are common to many of our products, and which differentiate<br />

ROTRONIC instruments from many alternatives on the market:<br />

Hygromer ® Sensor.<br />

The Hygromer sensor was fi rst introduced in 1979 in response to market<br />

demand for higher performance and lower costs. Since its launch,<br />

it has constantly been developed using the highest quality materials<br />

and the state-of-the-art production techniques.<br />

Today it still has the widest operating range of any %rh sensor on the<br />

market, working over the ranges of 0…100 %rh and –50…200 °C. It’s<br />

superb reputation for long term stability is second to none, and many<br />

examples can be seen in use after more than 20 years. It is also able to<br />

withstand exposure to condensation without affecting calibration.<br />

The Hygromer ® sensor is used in every product carrying the<br />

ROTRONIC brands HYGROMER ® and HYGROCLIP ® . Several versions<br />

are available with different characteristics, see page 109 for more information.<br />

The HygroClip ® Concept.<br />

HygroClip ® is a humidity and temperature measurement concept<br />

utilising an exclusive digital semiconductor technology. It is based<br />

on a custom ASIC*, designed specifi cally for humidity and temperature<br />

measurement applications and works in conjunction with the<br />

Hygromer sensor.<br />

Products based on HygroClip ® technology include features such as<br />

probe interchangeability, digital signal processing, digital calibration<br />

and much more.<br />

HygroClip technology is used in every product carrying the ROTRONIC<br />

HYGROCLIP ® brand.<br />

* Application Specifi c Integrated Circuit<br />

Custom Mechanical Components<br />

The precise measurement of humidity needs careful consideration of<br />

temperature. Even the best humidity sensor and electronics cannot<br />

compensate for mechanical components that do not respond quickly<br />

to temperature changes.<br />

Our in house design team have therefore created a range of custom<br />

mechanical components which provide the best combination of mechanical<br />

strength and optimum thermal properties to ensure that sensors<br />

have the best possible chance of accurate measurements.<br />

Compensation<br />

Hygrometers are usually only factory adjusted at ambient temperature,<br />

so ROTRONIC humidity instruments feature dynamic temperature<br />

compensation to ensure that measurement values are optimised<br />

across the entire working range. Even if you purchase a transmitter<br />

that measures humidity only, you will fi nd a temperature sensor integrated<br />

into the probe for this purpose. Our SCS laboratory can provide<br />

calibrations at higher or lower temperatures if required.<br />

Thanks to the use of the latest digital technology, ROTRONIC humidity<br />

instruments can also be specifi ed to include dynamic pressure compensation.


Contents<br />

Section Products: Page number range:<br />

Handheld <strong>Instruments</strong> HygroPalm, HygroClip probes, A1, GTS 4 - 13<br />

Dataloggers HygroLog, HygroClip probes, Agent D, Agent probes 14 - 25<br />

Transmitters HygroFlex, M-Series, Roline-L Series 26 - 67<br />

Meteorology MP100/400, MP100/400H, Mounting hardware 68 - 75<br />

Water Activity HygroLab, Aw Quick, AW-DIO, HygroClip probes 76 - 87<br />

Temperature Temperature Transmitters and Handhelds 88 - 91<br />

OEM Products HygroClip, OEM options 92 - 95<br />

Calibration SCS calibration standards, calibration devices 96 - 99<br />

HW3 Software Features and options 100 - 103<br />

Theory Sensors, defi nition, pollutant tables 104 - 110<br />

Index 111<br />

I<br />

N<br />

T<br />

R<br />

O<br />

D<br />

U<br />

C<br />

T<br />

I<br />

O<br />

N<br />

3


H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

4<br />

Handheld <strong>Instruments</strong><br />

Measurement of humidity and temperature is essential in many production, storage, transportation, and<br />

test applications. Many processes can only be performed if humidity and temperature conditions are within<br />

a specifi c range. Materials and products do not perform correctly if climatic conditions are incorrect.<br />

The ROTRONIC handheld instruments are the perfect tool for portable measurements, which are the fi rst<br />

step to defi ne ambient conditions.<br />

Our range of handheld instruments are highly accurate, but are easy to use and maintain. Confi guration<br />

and programming is performed in the factory; however, certain models offer the possibility to alter the<br />

instrument programming to specifi c customer needs with user-friendly software or integrated keypad.<br />

A wide range of interchangeable probes means simple maintenance and application fl exibility.<br />

Key features<br />

• Accuracy and long term<br />

stability<br />

• Interchangeable digital sensor<br />

module<br />

• Compact, modern instruments<br />

• Large display with good contrast<br />

• HOLD Function<br />

• Wide range of probes<br />

• Battery powered<br />

Your benefi ts<br />

� Reliable data and reduced<br />

maintenance<br />

� Simple calibration & maintenance<br />

� Easy to use and handle<br />

� Clear observation of measured values<br />

� Reliably capture of measured values<br />

� One instrument – many applications<br />

� Suitable for use anywhere<br />

Section contents Page<br />

HygroPalm Handheld <strong>Instruments</strong> for HygroClip probes 6 to 7<br />

� Interchangeable probes<br />

� Large easy-to-read display<br />

� Optional Docking Station<br />

� Temperature adaptors<br />

� RS232 Interface<br />

HygroClip probes for HygroPalm Handhelds 8 to 9<br />

� Wide range of options to suit any application<br />

� 0…100%rh, -50…200 °C<br />

� 100% interchangeable without adjustment<br />

Accessories and Sets of HygroPalm <strong>Instruments</strong> 10<br />

� Complete equipment for measuring and calibration<br />

� Handy cases<br />

� Connecting cables<br />

A1 and GTS <strong>Instruments</strong> for Special Applications 11<br />

� Handheld for paper stacks<br />

� Sets including calibration material


Building Management / HVAC<br />

Accurate and reliable thermohygrometers<br />

are needed to verify<br />

correct system performance<br />

during commissioning. Rotronic<br />

handhelds and their ability to be<br />

calibrated on-site often settles<br />

disputes about whose instrument<br />

is correct!<br />

Climatic test cabinets<br />

Many products are tested over<br />

a variety of climatic conditions.<br />

The exceptionally wide measuring<br />

range of the ROTRONIC<br />

handheld units means these<br />

conditions can be easily spot<br />

checked.<br />

Paper Industry<br />

The fi rst ROTRONIC products<br />

were developed for the paper<br />

industry, and today we have<br />

the largest world-wide sales of<br />

sword hygrometers for paper<br />

stack monitoring.<br />

Handheld Applications<br />

Research<br />

Many research tests must have<br />

the humidity conditions defi ned<br />

for the results to be accepted or<br />

considered to be reliable.<br />

Health and Fitness Centres,<br />

Hospitals, Classrooms<br />

In public areas it is especially<br />

important to maintain correct<br />

humidity values to minimise<br />

health risks.<br />

Museums, libraries &<br />

art galleries<br />

Conservation applications<br />

require dependable measurements<br />

and low cost of ownership.<br />

Rotronic handhelds have<br />

been a mainstay in this markets<br />

for three decades.<br />

Warehouses & storage<br />

Many products need to be stored<br />

in certain conditions to remain in<br />

good condition.<br />

Industrial process monitoring<br />

The maximum measurement<br />

temperature of 200°C and the robust<br />

design of our probes means<br />

that even the most diffi cult process<br />

application can be checked<br />

with a ROTRONIC handheld.<br />

H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

5


H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

6<br />

HygroPalm Series<br />

Humidity and Temperature Display Instrument for digital HygroClip ® probes<br />

HygroPalm represents a new generation of portable humidity/temperature instruments utilising the very<br />

latest digital technology. The advantage of digital technology is clear; highest precision is assured thanks<br />

to data transmission in a digital form, which means no signal loss over extended cable lengths and no external<br />

interference can infl uence measured values. Calibration data is maintained within the probe, which<br />

means there is no need to calibrate the whole system, and probes can be interchanged in seconds.<br />

HygroPalm 1<br />

Key features:<br />

• Handheld display unit for humidity and temperature<br />

• Digital signal processing for maximum accuracy<br />

• Display of dew point or wet bulb temperature<br />

• Standard alkaline batteries used<br />

• Interface for HygroFlex Transmitters<br />

• One-point adjustment of probes<br />

• Operating range probes: -50…200°C, probe dependent<br />

Order code:<br />

HygroPalm 1 (probe must be ordered separately)<br />

HygroPalm 2<br />

Key features:<br />

• All functions of HygroPalm 1<br />

• Second probe input %rh and °C<br />

• Multiple point probe adjustment<br />

• RS232 PC interface<br />

• Calculation of various psychrometric parameters<br />

• Formula Editor<br />

Order code:<br />

HygroPalm 2 (probe must be ordered separately)<br />

HygroPalm 3<br />

Key features:<br />

• All functions of HygroPalm 2<br />

• Universal input for pressure, air-speed etc.<br />

• Dynamic pressure compensation<br />

• Bi-directional interface for HygroFlex transmitters<br />

• Formula Editor<br />

Order code:<br />

HygroPalm 3 (probe must be ordered separately)<br />

PalmDock Docking Station<br />

Benchtop docking station designed for use with all HygroPalm models<br />

for RS232* PC interface and power connection (with external power<br />

adaptor).<br />

* HygroPalm 1 does not feature RS232 interface.<br />

Order code:<br />

PD 1 without lock<br />

PD 2 with lock<br />

PalmDock-1 with HW3 Software* & datacable, without lock<br />

PalmDock-2 with HW3 Software, datacable, & lock<br />

AC1207 Power adapter<br />

* Further information in the chapter HW3 Software


Feature Overview<br />

Highly precise & stable humidity<br />

& temperature sensors<br />

Big display<br />

for easy readings<br />

HOLD function<br />

for display<br />

5-button keypad for<br />

easy operation<br />

Battery<br />

compartment<br />

HygroPalm<br />

Interchangeable probes<br />

Calibration can be updated or the<br />

range of applications changed<br />

by the simple connection of a<br />

different probe.<br />

Interface Connector<br />

for HygroFlex Transmitter<br />

Universal Probe Input<br />

Psychrometric<br />

calculations available<br />

Option: Lock<br />

Docking Station<br />

Socket for Power adaptor<br />

RS232 interface<br />

for use with a PC<br />

H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

7


H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

8<br />

HygroClip Probes for HygroPalm<br />

A range of probes for different applications are available for the HygroPalm display instruments.<br />

All probes are based on the digital HygroClip technology, and can be interchanged within seconds without<br />

need for recalibration. With special adaptor cables, even probes designed for transmitters may be used.<br />

HygroClip S/S1<br />

Standard sensor module for humidity and temperature.<br />

A wire mesh fi lter provides sensor protection against dust and<br />

high air velocity.<br />

Dimensions Ø15 x 100 mm. IP rating: IP65<br />

HygroClip S1 is specially calibrated and certifi ed to provide measurement<br />

accuracy of ±1 %rh.<br />

Measurement range: -40…85 °C , 0…100 %rh<br />

Accuracy (S1): ±1.0 %rh, ±0.2 K (at 23 °C)<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23 °C)<br />

Order code:<br />

HygroClip S1<br />

HygroClip S<br />

Ø: 15 mm Length: 100 mm<br />

HygroClip SC04 / SC05<br />

4/5 mm diameter cable probe for humidity and temperature measurements<br />

in small spaces such as product & packaging testing, concrete,<br />

electronic test and climatic chambers.<br />

Cable length 2m<br />

Measurement range: -40…100 °C , 0…100 %rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip SC04 4 mmØ probe<br />

HygroClip SC05 5 mmØ probe<br />

Ø: 4/5 mm Cable: 2 m<br />

HygroClip HK 25 /HK40<br />

High temperature probe for measurements in ducts, dryers,<br />

climatic chambers etc. Probe length 250 or 400 mm.<br />

Measurement range: HK25: -50…150 °C, 0…100 %rh<br />

HK40: -50…200 °C, 0…100 %rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip HK25 (250 mm probe, max.150°C)<br />

HygroClip HK40 (400 mm probe, max. 200°C)<br />

Ø: 15 mm Probe length: 250 mm/400 mm Cable: 2 m


HygroClip SP05<br />

Fast response 5 mm diameter insertion probe with laser cut air slots<br />

for bulk goods such as corn, wheat, & granules. Also suitable for<br />

measurements in concrete and brick. Not suitable for powders.<br />

Probe length 200 mm.<br />

Measurement range: -40…85°C , 0…100 %rh,<br />

Accuracy: ±1.5 %rh , ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip SP05<br />

Ø: 5 mm Probe length: 200 mm Cable: 2 m<br />

HygroClip HP28<br />

Robust 10 mm diameter tubular probe for measurements in bulk<br />

products such as powders & granules.<br />

Probe length 280 mm, 2m cable, steel sinter fi lter.<br />

Measurement range: -40…85°C, 0…100 %rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip HP28<br />

Ø: 10 mm Probe length: 280 mm Cable: 2 m<br />

HygroClip HS28 Sword Probe<br />

For measurements in paper stacks/rolls. Lightweight, yet robust<br />

aluminium blade for fast temperature and humidity equilibrium.<br />

Blade 280 x 18 x 4 mm.<br />

Measuring range: -40…85°C, 0… 100 %rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip HS28<br />

Sword length: 280 mm Cable: 2 m<br />

HygroClip Probes for HygroPalm<br />

H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

9


H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

10<br />

Handheld Sets and Accessories<br />

Measuring instruments often need to be transported around site, and in some cases from building to<br />

building. We have created a series of handheld measurement sets which securely contain most commonly<br />

used standard equipment and accessories. Carry cases are also useful for storing instruments when not<br />

in use, and help to maintain long-term stability by protecting the units from climatic variations or contamination<br />

in storage conditions.<br />

HygroPalm 1 Set<br />

Consists of:<br />

• HygroPalm 1 Handheld Instrument<br />

• HygroClip-S probe<br />

• Calibration device ER15, fi tting for HygroClip-S<br />

• Humidity standards 50 %rh EA50-SCS<br />

• Robust carrying case AC1116<br />

Order code:<br />

HygroPalm 1-Set<br />

HygroPalm 2-Set-HS28<br />

Consists of:<br />

• HygroPalm 2 Handheld Instrument<br />

• HygroClip-HS28 probe<br />

• Calibration device EGS, fi tting for HygroClip-HS28<br />

• Humidity standards 50 %rh EA50-SCS<br />

• Robust carrying case AC1117<br />

• Software HW3<br />

• Connection Cable<br />

Order code:<br />

HygroPalm 2-Set-HS28<br />

HygroPalm 3-Set-PC<br />

Consists of:<br />

• HygroPalm 3 Handheld Instrument<br />

• HygroClip S probe<br />

• Calibration device ER15, fi tting for HygroClip-S<br />

• Humidity standards 50 %rh EA50-SCS<br />

• Robust carrying case AC1116<br />

• Software HW3<br />

• Connection Cable AC1622<br />

Order code:<br />

HygroPalm 3-Set-PC<br />

Temperature adaptor for Pt100 probes<br />

The HygroPalm can also handle Pt100 probes with standard Binder<br />

connector, see page 89 for a range of compatible Pt100 probes.<br />

Order code:<br />

HygroClip-TH100-B5<br />

Windspeed probe Mini Air6 Micro<br />

Mini Air 6 can be connected to HygroPalm 2 & 3 types<br />

as well as to data loggers and industrial transmitters.<br />

Measuring range: 0.5 – 20 m/s<br />

Temperature range: -10…80°C<br />

Output signal: 0 – 2.0 V<br />

Head-Size: Ø11 x 15 x 165 mm<br />

Cable length: 5 m<br />

Order code:<br />

MiniAir6 Micro 20M/s<br />

Other windspeed probes available on request<br />

Suitable for:<br />

HVAC technicians, supervisors<br />

Suitable for:<br />

Paper processing industry, any<br />

user of cut-sheet material<br />

Suitable for:<br />

Users who want to record<br />

measured values on a PC and<br />

calibrate their probes.


GTS and GTS-Set<br />

The GTS is a classic ROTRONIC product which has stood the test on time.<br />

It was designed specifi cally for the measurement of humidity and temperature within stacks of paper,<br />

cardboard or any other cut-sheet material.<br />

The robust design in combination with updated electronics make the GTS the most popular instrument<br />

for paper and card applications.<br />

GTS – for paper and cardboard stacks<br />

• Display of relative humidity or temperature<br />

• Simple one button operation<br />

• Auto power off function<br />

• Low-battery indicator<br />

Order code:<br />

GTS<br />

GTS – Set-Measurement set for cut-sheet material<br />

includes:<br />

GTS instrument<br />

Robust carrying case<br />

Calibration device EGS<br />

Humidity standards EA50-SCS<br />

(5 ampoules 50 %rh with SCS certifi cate)<br />

Adjustment tool<br />

Order code:<br />

GTS-Set<br />

Carrying case for GTS, without instrument<br />

Order code:<br />

AC1102 Case (without accessories)<br />

A1 for air measurement<br />

Another classic design which we retain thanks to continuing demand<br />

from our customers.<br />

• Reference probe for relative humidity and temperature<br />

• Integrated climate probe with adjustable position<br />

• Large, clear display<br />

• Simple operation<br />

• Hold function<br />

• Auto power off<br />

• Battery status indicator<br />

• Battery or accumulator operation<br />

• Temperature Display in °C or °F<br />

Order code:<br />

A1<br />

Accessories for the A1<br />

• Robust and handy carry case for A1 instruments plus accessories.<br />

• Calibration device EGL (see page 98)<br />

• Calibration standards (see page 97)<br />

Order code:<br />

AC1115 Case (without accessories)<br />

H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

11


H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

12<br />

Technical Data Summary<br />

Features HygroPalm 1 HygroPalm 2 HygroPalm 3 A1 GTS<br />

Humidity sensor Hygromer ® HygroClip-S probes with Hygromer ® AC-1 Sensor AC-1<br />

Temperature sensor Pt100 1/3 DIN Pt100 B<br />

Probe connections (combined %rh/°C) 1 2 Integrated probe<br />

Signal input<br />

1 digital 2 digital<br />

2 digital or<br />

4 analogue<br />

Third party probe input No 0…2.5 V<br />

Supply for 3 rd party probe No 9 V / 10 mA No<br />

RS232 Interface No Yes No<br />

Display Humidity<br />

3-digit LCD 3-digit LCD<br />

3-line alphanumeric LCD<br />

Temperature 3 1⁄2 digit LCD (%rh or ° C)<br />

Display units %rh, °C, °F, calculated param. Freely select. %rh, °C, °F %rh, °C, °F<br />

Resolution 0.1%rh/ 0.1°C 0.1%rh/0.1°C 0.1%rh/0.1°C<br />

Probe adjustment<br />

1 point %rh, °C By Keypad By potentiometer<br />

4-point %rh, 2 point °C No By Keypad and Software No<br />

3-point %rh, T min./Tmax. N/A 35 / 80 / 10 % No<br />

2-point %rh, Tmin / Tmax N/A 35 / 80%<br />

Calculation & unit display<br />

Dew-point and wet bulb temperature Yes No<br />

Full psychrometric calculation No Yes No<br />

Pressure compensation No manually dynamically<br />

of calculated values adjustment with Software with pressure No<br />

probe input<br />

Humidity displayed in Aw units No Yes No<br />

Formula Editor No Yes No<br />

Remote Transmitter Control<br />

Transmitter adjustment No Yes No<br />

Transmitter adjustment<br />

against reference probe<br />

No Yes No<br />

Transmitter measurement display Yes No<br />

Transmitter status display No Yes No<br />

Operating ranges of electronics<br />

Humidity/Temperature<br />

Measuring ranges<br />

Measuring ranges (probes)<br />

Accuracy at 23 °C<br />

0…100 %rh, non condensing / -10…60°C<br />

Probe dependent 0…100 %rh / -50…200°C<br />

±1.5 %rh/ ±0.3 K<br />

Reproducibility < 0.5 %rh / < 0.1 K<br />

Long Term Stability < 1 %rh / Year<br />

Power Supply<br />

9 V PP3 alkaline battery Yes<br />

0…100 %rh<br />

-10…50°C<br />

5…99.9 %rh / 5…99.9 %rh<br />

-25…75°C -10…50°C<br />

±1.5 %rh / (±2.5 90%)<br />

±0.3 K<br />

9V Accumulator Yes No Yes<br />

230 V External supply voltage Optional, only with Docking Station No<br />

Type of enclosure / IP Rating IP 50<br />

Housing material ABS<br />

Dimensions in mm 295 x 70 x 35 190 x 63 x 26 420 x 70 x 40<br />

Weight ca. 200 g ca. 170 g ca. 400 g


GTS<br />

A1<br />

62.8<br />

27<br />

HygroPalm<br />

57<br />

150<br />

~40<br />

RH<br />

°C<br />

65<br />

191 167<br />

A1<br />

Dimensional Diagrams<br />

40<br />

18<br />

260<br />

5<br />

ø10<br />

H<br />

A<br />

N<br />

D<br />

H<br />

E<br />

L<br />

D<br />

I<br />

N<br />

S<br />

T<br />

R<br />

U<br />

M<br />

E<br />

N<br />

T<br />

S<br />

13


D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

14<br />

Dataloggers<br />

Long term recording of humidity and temperature measurements is essential in many production, storage,<br />

transportation, display and test applications. They provide valuable information on the levels and variation<br />

of humidity and temperature which can have a signifi cant impact on people, materials and objects.<br />

The ROTRONIC range of data loggers and recorders are highly accurate and stable, but are easy to use<br />

and maintain. Confi guration and programming can easily be performed by any operator, with user-friendly<br />

software or integrated keypads. Data can be presented in a graphical or statistical format. A wide range of<br />

interchangeable probes means simple maintenance and application fl exibility.<br />

Key features<br />

• Compact stand alone modules<br />

• Measurement display<br />

• Accuracy and Long Term Stability<br />

• Interchangeable sensor module<br />

• Wide range of probes<br />

• Robust IP65 housing with shock protection<br />

• Battery powered<br />

• Custom mounting hardware<br />

• Large memory<br />

• User-friendly Software<br />

• Validated software FDA CFR 21 part 11<br />

Your benefi ts<br />

� Easy to install and fl exible<br />

� Easy observation of current values & alarms<br />

� Reliable data and reduced maintenance<br />

� Easy calibration & maintenance<br />

� One logger – many applications<br />

� Suitable for industrial use.<br />

� No installation costs and can be easily relocated<br />

� Professional installation<br />

� Long term recording up to one year<br />

� Easy to learn and use<br />

� High quality assurance<br />

Section contents Page<br />

HygroLog and HygroLog D Data logger for<br />

HygroClip probes 16 to 17<br />

� Interchangeable probes<br />

� Integrated display<br />

� Alarm function<br />

� Validated, easy-to-use software<br />

HygroClip probes for HygroLog Data logger 18 to 19<br />

� Wide range of options to suit any application<br />

� 0…100 %rh, -50…200 °C<br />

� 100 % interchangeable without adjustment<br />

Agent D Data logger for humidity and temperature 20 to 23<br />

� 64000 point memory<br />

� Multi channel temperature only versions<br />

� EX rated<br />

� External start feature<br />

Accessories for HygroLog and Agent D 24 to 25<br />

� Installation hardware<br />

� Impact protection<br />

� Connecting cables<br />

� Power supplies


Store rooms and warehouses<br />

Production areas<br />

Datalogger Applications<br />

Museums, libraries & art galleries<br />

Transportation<br />

Clean rooms<br />

Controlled environments &<br />

cabinets<br />

D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

15


D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

16<br />

HygroLog and HygroLog D<br />

Humidity and Temperature logger for digital HygroClip ® probes.<br />

The HygroLog data logger uses the HygroClip range of digital probes for long term recording of humidity<br />

and temperature conditions. By using the digital signal output from the HygroClip probes, measurement<br />

precision is optimised with no signal loss over extended cable lengths and no external interference can<br />

infl uence measured values. Calibration data is maintained within the probe, which means there is no need<br />

to calibrate the whole system, and probes can be interchanged in seconds. In conjunction with the HW3<br />

software, the HygroLog can be supplied with full validation documentation.<br />

HygroLog<br />

Self contained data logger for HygroClip ® digital probes<br />

Key features:<br />

• Stores up to 2 x 5000 values for humidity and temperature<br />

• Digital signal processing for maximum accuracy<br />

• Logging interval from 15 seconds to 2 hours<br />

• Standard alkaline batteries used<br />

• Operating modes selectable: Start/stop or loop mode<br />

• Operating range Logger: 0…100 %rh; -30 …70°C<br />

(Battery-dependent; with alkaline batteries –10…50°C)<br />

• Measuring range Probes: -50…200°C, probe dependent<br />

Order code:<br />

HygroLog (probe must be ordered separately)<br />

HygroLog D<br />

Humidity and Temperature data logger with LCD display for<br />

HygroClip ® digital probes<br />

Key features:<br />

• Stores up to 2 x 5000 values for humidity and temperature<br />

• Digital signal processing for maximum accuracy<br />

• Logging interval from 15 seconds to 2 hours<br />

• Standard alkaline batteries used<br />

• Operating modes selectable: Start/stop or loop mode<br />

• Operating range Logger: 0…100 %rh; -10 …50°C<br />

(Battery-dependent; with alkaline batteries –10…50°C)<br />

• Operating range -50…200°C (probe dependent)<br />

• Visual alarm indicators on LCD for temperature & humidity<br />

• Battery status display<br />

• Status display saving / busy<br />

Order code:<br />

HygroLog-D (probe must be ordered separately)<br />

Software HW3 and Data Cable (FDA CFR 21 Part 11)<br />

The validated multilingual software HW3 is used for programming the<br />

loggers as well as to retrieve data. Data may be displayed in a table or<br />

graph form. A language editor gives the user the possibility to translate<br />

the text into his own language. Psychrometric calculations such as<br />

dewpoint may also be performed within the software, and the option<br />

to show these values on the graphic is also included. Calculations may<br />

be executed by using a pressure constant or, depending on the instruments<br />

connected, dynamically with a pressure probe. As the software<br />

can also be used with the full ROTRONIC product range, it offers a variety<br />

of other features, such as sending e-mails in case of alarms, data<br />

archiving, etc. Of course, measurement data can also be exported to<br />

MS Offi ce applications.<br />

For extended description see section HW3 software.<br />

Order code:<br />

HygroData HL


Feature Overview<br />

Highly precise and stable humi -<br />

dity and temperature sensors<br />

HygroLog<br />

Interchangeable probes<br />

Calibration can be updated,<br />

or the range of application<br />

changed by the simple<br />

connection of a different<br />

probe. See next page for<br />

available options. 10000 point<br />

integrated memory<br />

Connection socket for probe<br />

or PC interface cable<br />

Wall mounting bracket with option<br />

to connect mains power adapter<br />

Robust IP65 enclosure<br />

Integrated LC display<br />

Includes battery status<br />

and alarm indicators<br />

Programmable<br />

measurement interval<br />

15 seconds to 2 hours<br />

User replaceable batteries<br />

D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

17


D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

18<br />

HygroClip probes for HygroLog Datalogger<br />

A range of probes for different applications are available for the HygroLog Dataloggers. All probes<br />

are based on the digital HygroClip technology, and can be interchanged within seconds without need<br />

for recalibration. With special adaptor cables, even probes designed for transmitters may be used.<br />

HygroClip S/S1<br />

Standard sensor module for humidity and temperature. A wire mesh<br />

fi lter provides sensor protection against dust and high air velocity.<br />

Dimensions Ø15 x 100 mm. IP rating: IP65<br />

HygroClip S1 is a specially calibrated and certifi ed to provide<br />

measurement accuracy of ±1%rh.<br />

Measurement range: -40…85°C, 0…100%rh<br />

Accuracy (S1): ±1.0 %rh, ±0.2 K (at 23°C)<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip S1<br />

HygroClip S<br />

Ø: 15 mm Length: 100 mm<br />

HygroClip SC04 / SC05<br />

4/5 mm cable probe for humidity and temperature measurements in<br />

small spaces such as product & packaging testing, concrete, electronic<br />

test and climatic chambers.<br />

Cable length 2m<br />

Measurement range: -40…100°C, 0…100%rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip SC04 4 mmØ probe<br />

HygroClip SC05 5 mmØ probe<br />

Ø: 4/5 mm Cable: 2 m<br />

HygroClip HK 25 /HK40<br />

High temperature probe for measurements in ducts, dryers, climatic<br />

chambers etc. Probe length 250 or 400 mm. Wire mesh fi lter included.<br />

Measurement range: HK25: -50…150°C, 0…100%rh<br />

HK40: -50…200°C, 0…100%rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip HK25 (250 mm, max.150°C)<br />

HygroClip HK40 (400 mm, max. 200°C)<br />

Ø: 15 mm Probe length: 250 mm/400 mm Cable: 2 m


HygroClip SP05<br />

HygroClip Probes for HygroLog Datalogger<br />

Fast response 5 mm diameter insertion probe with laser cut air slots<br />

for bulk goods such as corn, wheat, & granules. Also suitable for<br />

measurements in concrete and brick. Not suitable for powders.<br />

Probe length 200 mm<br />

Measurement range: -40…85°C , 0…100 %rh,<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip SP05<br />

Ø: 5 mm Probe length: 200 mm Cable: 2 m<br />

HygroClip HP28<br />

Robust 10mm diameter tubular probe for measurements in bulk<br />

products such as powders & granules. Probe length 280 mm,<br />

2m cable, steel sinter fi lter.<br />

Measurement range: -40…85°C, 0…100%rh<br />

Accuracy: ±1.5%rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip HP28<br />

Ø: 10 mm Probe length: 280 mm Cable: 2 m<br />

HygroClip HS28 Sword Probe<br />

For measurements in paper stacks/rolls. Lightweight, yet robust aluminium<br />

blade for fast temperature and humidity equilibrium.<br />

Blade 280 x 18 x 4 mm.<br />

Measuring range: -40…85°C, 0… 100 %rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip HS28<br />

Sword length: 280 mm Cable: 2 m<br />

D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

19


D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

20<br />

Agent-D Series<br />

Agent-D Series Humidity and temperature logger<br />

The Agent-D series is a versatile family of data-loggers with integrated LC display for the<br />

measurement of humidity and temperature with both integrated and cable mounted sensors.<br />

Measurement ranges and logging interval can be confi gured with easy-to-use Windows software,<br />

or via the integrated keypad. A special version is available for hazardous areas (Zone 1). All versions<br />

feature a 64000 point memory, user replaceable batteries and the operating range of the<br />

logger is -35…55°C / 0…100 %rh. Measurement range depends on the probe confi guration. (see<br />

Probes for Agent-D-NT & PT Series)<br />

Agent-D-HT2<br />

2-channel humidity and temperature logger<br />

• Integrated probe for temperature / humidity Agent-D-Clip-S<br />

• Optional remote probe for humidity and temperature<br />

• Measuring range with:<br />

– integrated probe: -35…55°C / 0…100 %rh<br />

– remote probe: -35…70°C / 0…100 %rh<br />

– high temp. remote probe: -35…110°C / 0…100%rh<br />

• Single digital input for monitoring doors etc (switch status)<br />

Order code:<br />

Agent-D-HT2 included probe Agent-D-Clip-S<br />

Agent-D-HT2-EX (for EX-Zone 1) included probe Agent-D-Clip-S<br />

Agent-D-NT3<br />

3-channel temperature logger with NTC probes<br />

• 1 integrated NTC temperature sensor<br />

• 2 external NTC probes connected by D-sub-15 plug<br />

• Measuring range: -50…140°C<br />

Order code:<br />

Agent-D-NT3<br />

Agent-D-NT3-EX (for EX-Zone 1)<br />

Agent-D-PT4<br />

4 channel temperature logger for Pt100 probes<br />

• Integrated keypad<br />

• Pt100 probe 4 wire connection, Lemo or D-sub connector<br />

• Measuring range: -200…550°C<br />

• Single digital input for monitoring doors etc (switch status)<br />

Order code:<br />

Agent-D-PT4<br />

Probe must be ordered separately, see page 22.


Feature Overview<br />

Digital display for measured<br />

value, date, time and alarm<br />

(displayable down to –20°C)<br />

Alarm-reset,<br />

measuring values and<br />

alarm scroll via keypad<br />

Results may be<br />

printed directly<br />

without a PC<br />

External start<br />

(devices without keypad only),<br />

Agent-D Series<br />

Display test<br />

Memory for 64,000<br />

measurement values<br />

Choice of sensors:<br />

Humidity/temperature<br />

combined<br />

or Temperature<br />

only see page 22 and 23<br />

Replaceable, commercially available<br />

batteries<br />

D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

21


D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

22<br />

Probes for Agent-D-NT & PT Series<br />

Agent-D-HT2 Probes<br />

Combined standard probe for temperature & humidity<br />

Measuring range: –35…70°C / 0…100 %rh<br />

High temperature probe: –35…110°C<br />

Refurbished (standard) probe<br />

Order code:<br />

Agent-D-Clip S Standard probe<br />

Agent-D-Clip H High temperature probe Agent-D-Clip H<br />

(with Agent-D-D12 only)<br />

Agent-D-Clip R Refurbished standard probe<br />

Temperature probe Specifi cation Probe Order code<br />

1 probe 1 probe 2 probe<br />

Lemo Plug D-sub Plug D-sub Plug<br />

Universal probe -50...140°C<br />

Cable length: 2 m NTC AC3010-NL AC3010-ND1 AC3010-ND2<br />

T max. Cable: 140°C<br />

-80...260°C<br />

Cable length: 4 m Pt100 AC3163-PL<br />

T max. Cable: 140°C<br />

Miniature bead probe -50...140°C<br />

Cable length: 2 m NTC AC3055-NL AC3055-ND1 AC3055-ND2<br />

T max. Cable: 140°C<br />

Surface probe<br />

Plug-in probe<br />

Robust universal probe<br />

Flexible universal probe<br />

High temperature probe<br />

Agent-D Probes<br />

-50...140°C<br />

Cable length: 2 m NTC AC3041-NL AC3041-ND1<br />

T max. Cable: 140°C<br />

-35...55°C NTC AC3060-NL<br />

Pt100 AC3160-PL<br />

-50...140°C<br />

Cable length: 10 m NTC AC3090-NL<br />

T max. Cable: 140°C<br />

-200...350°C<br />

Cable length: 5 m Pt100 AC3165-PL<br />

T max. Cable: 140°C<br />

-80...500°C<br />

Cable length: 4 m Pt100 AC3162 - PL<br />

T max. Cable: 250°C


Agent-D Series<br />

Agent-D-HT2<br />

8 1 5<br />

1<br />

9<br />

Agent-D-PT4<br />

8 1 5<br />

1<br />

9<br />

Agent-D-NT4<br />

8 1 5<br />

1<br />

9<br />

Agent-D-NT3<br />

8 1 5<br />

1<br />

9<br />

8 GND 15 RxD<br />

7 TxD 14 Busy<br />

6 + Ref. 13 NTC1<br />

5 A1 12 NTC2<br />

4 A2 11 D1, 2<br />

3 B1 10 DigitIn<br />

2 B2 9 Alarm<br />

1 C1, 2<br />

8 GND 15 RxD<br />

7 TxD 14 Busy<br />

6 Ubat 13 A2<br />

5 A1 12 A2<br />

4 A1 11 B 2<br />

3 B1 10 DigitIn<br />

2 B1 9 Alarm<br />

1 B2<br />

8 GND 15 RxD<br />

7 TxD 14 Busy<br />

6 NTC2 13 Res.<br />

5 +Ref 12 DigitIn1<br />

4 NTC4 11 Ubat<br />

3 NTC3 10 DigitIn2<br />

2 +Ref 9 Alarm<br />

1 NTC1<br />

8 GND 15 RxD<br />

7 TxD 14 Busy<br />

6 NTC2 13 Res.<br />

5 +Ref 12 Start/<br />

Inpos<br />

4 Res 11 Ubat<br />

3 NTC3 10 Alarm<br />

Reset<br />

2 +Ref 9 Alarm<br />

1 NTC1<br />

NTC<br />

+Ref<br />

A<br />

B<br />

C<br />

D<br />

GND<br />

+Ref<br />

DigitIn<br />

Alarm +<br />

GND<br />

PTA<br />

PTA<br />

PTB<br />

PTB<br />

Ubat<br />

DigitIn<br />

Alarm +<br />

GND<br />

NTC<br />

+Ref<br />

UBat<br />

DigitIn<br />

Alarm +<br />

GND<br />

NTC<br />

+Ref<br />

UBat<br />

Start/Inpos<br />

Ubat<br />

Alarm Reset<br />

0…50VDC, max. 200mA<br />

0…50VDC, max. 200mA<br />

0…50VDC, max. 200mA<br />

Schematics<br />

Electrical connections Electrical diagrams Dimensional diagrams<br />

A B<br />

A<br />

B<br />

8 4<br />

3 4<br />

LEMO connector<br />

(View from the<br />

solder side)<br />

8 4<br />

3 4<br />

8 4<br />

3 4<br />

8 4<br />

3 4<br />

1 1 1 . 5<br />

Keyboard<br />

F 1 F 2 F 3<br />

5 8<br />

Replaceable humidity and<br />

temperature sensor module<br />

1 1 1 . 5 3 4<br />

F 1 F 2 F 3<br />

5 8<br />

1 1 1 . 5 3 4<br />

F 1 F 2 F 3<br />

5 8<br />

NTC sensor integrated in logger housing<br />

1 1 1 . 5 3 4<br />

5 8<br />

D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

23


D<br />

A<br />

T<br />

A<br />

L<br />

O<br />

G<br />

G<br />

E<br />

R<br />

S<br />

24<br />

Accessories<br />

For HygroLog<br />

Wall Mounting Bracket and Anti Theft Device<br />

Wall mounting bracket with integrated power supply connector, suitable<br />

for AC1207 adaptor. May be combined with Anti Theft Device<br />

AC1005.<br />

The HygroLog-IPH is fi xed on a fl at surface together with the securing<br />

plate by two screws. A steel rod with a padlock secures the logger in<br />

place. (Delivered without padlock)<br />

Order code:<br />

HygroLog-IPH Wall mounting bracket<br />

AC1207 AC Adaptor<br />

AC1005 Anti Theft Device<br />

Extension Cables and Adaptors<br />

For applications in high temperatures or in ducts, etc. where the logger<br />

housing may not be located in directly. Available in 2 lengths:<br />

Order code:<br />

MOK-01-DAT05 1m<br />

MOK-02-DAT05 2m<br />

12.02.1086 USB Adapter<br />

T7-03-DAT05 Adaptor for industrial probes<br />

Impact Protection HygroLog-SP<br />

The impact protection HygroLog-SP may be a welcome accessory<br />

in cases where the logger is exposed to shocks, vibrations and harsh<br />

environmental conditions. It protects the logger, thus saving you<br />

money in the long run.<br />

Order code:<br />

HygroLog-SP<br />

For Agent-Series<br />

Protocol Printer<br />

Thermo printer with serial interface for print-outs of the logged data<br />

Order Code:<br />

Agent-D-Print Printer<br />

Agent-D-DataP Data cable printer<br />

Agent-D-Data Data cable PC/Logger<br />

Probe Cables<br />

Extension cable for 1 or 2 Agent-D-Clip probes Agent D-HT2,<br />

for D-Sub connector. Lengths: 2 and 5 m<br />

Order code:<br />

Agent-D-D12 2 m / 1 Probe<br />

Agent-D-D22 2 m / 2 Probes<br />

Agent-D-D15 5 m / 1 Probe<br />

Agent-D-D25 5 m / 2 Probes<br />

Various<br />

Order code:<br />

Agent-D-SW Application Software multilingual<br />

Agent-D-SW-UP Software Update<br />

Agent-D-IPH Mounting bracket<br />

Agent-D-IPH-L Mounting bracket lockable<br />

Agent-D-AL Connector plug with screw terminals<br />

Agent-D-Bat Lithium battery for Agent-D


Series HygroLog HygroLog D Agent-D-HT2 Agent-D-NT3 Agent-D-PT4<br />

Humidity sensor HygroClip-S probe C 94 N/A N/A<br />

Temperature sensor with HYGROMER ® AC-1 NTC NTC Pt100<br />

Pt100 1/3 DIN<br />

Operating ranges<br />

Humidity 0…100 %rh 0...100 %rh<br />

Temperature - 35...55 °C<br />

- with alkaline battery -10...50°C<br />

- with special batteries -30...70°C -10...50°C<br />

Measuring ranges<br />

Humidity = Operating range of probe 0...100 %rh N/A<br />

Temperature = Operating range of probe -50...140°C -200...550°C<br />

Accuracy at 23°C ±1.5 %rh / ±0.3 K<br />

Output signal RS232<br />

Reproducibility < 0.5 %rh /


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

26<br />

Transmitters<br />

ROTRONIC humidity and temperature transmitters are world renowned for their excellent precision, longterm<br />

stability and reliability. Today our transmitter range offers an unparalleled range of innovative features<br />

to compliment the core ROTRONIC abilities of accuracy, reliability and long term stability.<br />

Transmitters are measuring instruments for fi xed installation with a specifi c signal output; primarily made<br />

for process applications and control. In climate control applications, ROTRONIC transmitters are used to<br />

optimise energy use and create a comfortable environment. Key features are accuracy, long term stability,<br />

time/cost saving installation, and low cost maintenance; they will easily outperform the low cost products<br />

typically used in commercial BMS/HVAC systems.<br />

Typical applications include building management systems, offi ce buildings, storage areas, clean rooms,<br />

hospitals, computer rooms, telecommunications centres.<br />

ROTRONIC industrial transmitters are robust – high quality products designed specifi cally for demanding<br />

commercial and industrial applications. They tolerate exposure to wide temperature variation, condensation<br />

and high levels of chemical pollution thanks to the unique properties of the Hygromer ® humidity sensor,<br />

which ensures excellent long-term stability in the most demanding applications. The highest precision<br />

over a wide operating range is achieved with dynamic temperature compensation (-50…200°C).<br />

The new generation of HygroClip industrial transmitters is based on the latest digital fl ash technology so<br />

probes can be interchanged with no effect on system accuracy. The modular probe concept means on-site<br />

calibration and maintenance is virtually eliminated. State of the art features also include calculation of a<br />

wide range of humidity parameters, user programmable scaling of output signals and networkable digital<br />

communications.<br />

Typical applications include process monitoring and optimisation, test cells, drying processes up to 200°C,<br />

climatic chambers, and high value product environments such as the pharmaceutical and semiconductor<br />

industries.<br />

Key features<br />

• Excellent long term stability


Power Stations<br />

Power generation, whether nuclear<br />

or fossil fuelled requires<br />

carefully controlled environments<br />

for best performance and<br />

reliability.<br />

Drying processes.<br />

Monitoring and control of any industrial<br />

drying process can have<br />

signifi cant benefi ts in terms of<br />

product quality, energy use and<br />

productivity.<br />

Environmental Test.<br />

Every product from mobile<br />

telephones to a car is today<br />

subjected to thorough climatic<br />

test conditions to establish and<br />

maintain reliability. Humidity<br />

and temperature conditions are a<br />

critical part of this process.<br />

Transmitter Applications<br />

High temperature.<br />

HygroFlex offers the highest direct<br />

humidity measurement currently<br />

available.<br />

Ceramics Industry.<br />

The measurement and control of<br />

the drying processes in the ceramics<br />

industry.<br />

Intrinsically safe.<br />

In combination with the<br />

HygroClip EX, the HygroFlex can<br />

be used to measure humidity<br />

and temperature in the most<br />

hazardous zone 0.<br />

Hazardous storage areas<br />

Explosive materials such<br />

as weapons or chemicals<br />

also need to be kept at the correct<br />

humidity and temperature<br />

conditions.<br />

Paper Industry<br />

Monitoring and control of the<br />

drying process.<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

27


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

28<br />

The Digital Advantage<br />

1. Measurement Accuracy:<br />

Digital processing of sensor signals provides much more scope and fl exibility for the compensation of error<br />

components such as linearity and temperature coeffi cients. ROTRONIC sensors have always been regarded<br />

as amongst the most precise and stable in the world; with this new technology, small errors become even<br />

smaller!<br />

2. Maintenance and Calibration:<br />

Digital signal communication allows components to be ‘hot swapped’ without loss of measurement precision<br />

– calibration and sensor data are retained permanently within each digital HygroClip probe.<br />

HygroClip probes can be ‘hot swapped’ in seconds, signifi cantly reducing the maintenance and downtime<br />

costs associated with the removal of instruments to laboratories or workshops for diffi cult, time-consuming<br />

calibration and repair. HygroFlex can also be fi eld calibrated and adjusted directly using the HygroPalm 3<br />

calibrator.<br />

3. Precision and Stability:<br />

Digital circuits are inherently more stable than analogue, and are less affected by temperature changes.<br />

Calibration adjustment is made purely by software, meaning no unstable, hard-to-reach potentiometers.<br />

The option for multiple calibration points is extended across the full measurement range.<br />

4. Application Flexibility:<br />

HygroFlex<br />

HygroFlex is a new generation of industrial humidity and temperature transmitters based on the very latest<br />

digital technology. Digital signal processing signifi cantly benefi ts humidity and temperature measurement<br />

in fi ve key areas:<br />

Measurement change? Need dew-point instead of %rh? Or the mixing ratio ? Simply connect the HygroFlex<br />

to a PC and change the confi guration!<br />

Different installation? If your application needs change, simply fi t one of the wide range of probes with an<br />

alternative confi guration or temperature operating range.<br />

Multiple point measurement? Need to expand? The HW3 software package offers a comprehensive networking<br />

solution for up to 32 instruments. HW3 features data logging (reporting), graphical and alarm functions<br />

and operates on any standard Windows based PC.<br />

Wiring hardly possible? Or too expensive? The HygroFlex is able to communicate by means of a radio controlled<br />

interface option.<br />

5. Measurement of Dew Point and other Parameters:<br />

Digital technology makes it possible to obtain parameters such as dew point or the mixing ratio with economical,<br />

versatile and easy-to-maintain instruments and probes. Taking the chilled mirror technology as an<br />

example, typical requirements and problems are eliminated: no sampling system is required in most applications,<br />

there is no longer any uncertainty between dew and frost, and the requirement for frequent mirror<br />

cleaning fully disappears.


Core features<br />

High quality electronics<br />

High quality, high stability electronics<br />

ensure consistent long<br />

term performance<br />

High temperature capability<br />

ROTRONIC transmitters<br />

have the widest direct<br />

humidity measurement<br />

range in the world working<br />

from –50…200°C.<br />

High quality sensor<br />

The Hygromer ® IN-1 humidity<br />

sensor is arguably the best in<br />

the world. Precise factory adjustment<br />

and superb long term stability<br />

provide consistent measurement<br />

results with minimum<br />

maintenance.<br />

HygroFlex<br />

Temperature compensated<br />

All ROTRONIC transmitters are<br />

dynamically temperature compensated<br />

to maintain best possible<br />

humidity measurement accuracy<br />

over very wide temperature<br />

ranges.<br />

Interchangeable probes.<br />

Across the entire ROTRONIC<br />

transmitter range it is possible<br />

to specify interchangeable<br />

probes; simplifying fi eld<br />

maintenance and maximising<br />

application fl exibility.<br />

User calibration<br />

All ROTRONIC transmitters can<br />

be adjusted by the user to provide<br />

optimum precision throughout<br />

the product’s life without<br />

expensive ‘return to base’ maintenance.<br />

Digital technology<br />

Digital signal processing not<br />

only provides the best possible<br />

precision, but also allows fully<br />

digital adjustment for all industrial<br />

HygroClip probes.<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

29


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

30<br />

Key features:<br />

• %rh and temperature<br />

• Interchangeable probes<br />

• Two linear analogue outputs<br />

• Jumper confi guration of<br />

analogue outputs<br />

• One probe input, digital or<br />

analogue (0…2.5 V, 10 Bit A/D;<br />

12 Bit interpolated)<br />

• Optional display/keypad<br />

HygroFlex 1<br />

Analogue outputs<br />

HygroFlex 1 accepts one HygroClip probe and provides two linear<br />

analogue outputs for relative humidity and temperature. Standard<br />

factory confi guration is 4…20 mA, but this can be easily changed to<br />

0…20 mA, 0…1 V, 0…5 V or 10 V. Scaling of the output range can be<br />

modifi ed from the standard 0…100%rh and 0…100°C using the internal<br />

service connection, connecting cable AC1623 and a PC running<br />

the HW3 software.<br />

An external test socket is standard. A HygroPalm 3 handheld instrument<br />

can be connected to provide a live display of the transmitters<br />

current measurement values. When connected, the HygroPalm 3 can<br />

also be used as a digital adjustment tool for any probe connected to<br />

the HygroFlex 1.<br />

The optional display & keypad gives a local display of measurement<br />

values and provides access to the 1 or 4 point probe adjustment directly<br />

from the HygroFlex 1 transmitter.<br />

For probe options, see page 34 to 35.<br />

HygroFlex 1 Ordering Information for Standard Versions<br />

H T S 1 1 X HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 12…35 VDC/24 VAC power<br />

H T S 1 2 X HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 90...250 VAC power<br />

H T S 1 1 D HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 12…35 VDC/24 VAC power;<br />

Display & Keypad<br />

H T S 1 2 D HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 90...250 VAC power;<br />

Display & Keypad<br />

(see page 33 for order codes for special versions)<br />

HygroFlex 1 Standard Connection Layout<br />

Probe (Tuchel) Test socket<br />

(Binder 712, 2-pin)<br />

2x M16 Cable glands for<br />

power and signal cables


Digital output, two Probes and Calculation function<br />

HygroFlex 2<br />

HygroFlex 2 measures and transmits humidity and temperature measurements only in a digital format. The<br />

data is either output in an RS232 signal directly to a PC, or up to 32 transmitters can be networked together<br />

using RS485 for network communication, with RS232 used for PC connection. HygroFlex 2 is also supplied<br />

as standard with the capability to accept a second probe input and has integrated psychrometric calculation<br />

for parameters such as dew-point or mixing ratio. Thanks to the possibility to accept 2 probes, it is possible<br />

to set up a network with up to 64 probes = 128 measuring values at a very reasonable price. Probe- cables of<br />

up to 200m cover all applications. Standard features also include full user programmability and an external<br />

test socket.<br />

An external test socket is standard. A HygroPalm handheld instrument<br />

can be connected to provide a live display of the transmitters current<br />

measurement values. When connected, the HygroPalm can also<br />

be used as a digital adjustment tool for any probe connected to the<br />

HygroFlex.<br />

The optional display & keypad gives a local display of measurement<br />

values and provides access to the 1 or 4 point probe adjustment<br />

directly from the HygroFlex 2 transmitter.<br />

HygroFlex 2 Ordering Information for Standard Versions<br />

Key features:<br />

H T S 2 1 X HygroFlex 2; digital output only; 12…35 VDC/24 VAC power; 2 probe inputs<br />

H T S 2 2 X HygroFlex 2; digital output only; 90...250 VAC power; 2 probe inputs<br />

H T S 2 1 D HygroFlex 2; digital output only; 12…35 VDC/24 VAC power; 2 probe inputs;<br />

Display & Keypad<br />

H T S 2 2 D HygroFlex 2; digital output only; 90...250 VAC power; 2 probe inputs;<br />

Display & Keypad<br />

(see page 33 for order codes for special versions)<br />

HygroFlex 2 Standard Connection Layout<br />

Test socket<br />

(Binder 712, 2-pin)<br />

Probe 1 (Tuchel)<br />

Probe 2 (Tuchel)<br />

• %rh and temperature<br />

• Display of calculated values;<br />

dew-point, mixing ratio, etc<br />

(with keypad/display option)<br />

• RS232 output (%rh and temperature)<br />

• Networkable (RS485)<br />

• 2 nd probe input (digital or analogue<br />

0…2.5V e.g. pressure)<br />

• Fully user programmable<br />

Serial connection RS232/485<br />

(Binder 763/ 5-pin)<br />

Power connection<br />

(M16 cable gland)<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

31


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

32<br />

HygroFlex 3<br />

Simultaneous Analogue and Digital Outputs with Absolute Humidity Calculation<br />

HygroFlex 3 combines all the features of the HygroFlex 1 and 2 into a highly specifi ed instrument, and<br />

represents probably the most advanced humidity and temperature transmitter on the market. Additional<br />

features include a third analogue output for greater fl exibility, a simultaneous serial output and the ability<br />

to dynamically compensate calculated humidity parameters for variations in application pressure.<br />

The comprehensive range of outputs available makes the HygroFlex 3 particularly well suited to combined<br />

monitoring and control applications. The analogue outputs can be connected to the applications control<br />

system, whilst the digital RS232 signal interfaces with a local PC where engineers can monitor the process<br />

and set up alarms via Email or SMS text messages.<br />

The dynamic pressure compensation feature is truly state of the art. In climatic test or research and development<br />

projects, the humidity measurements can be optimised for any condition with the inclusion of<br />

pressure measurement, and therefore compensation of pressure dependent calculated values such as enthalpy<br />

and wet-bulb temperature. All calculated parameters are based on WMO formulae.<br />

Key features:<br />

• %rh, temperature and calculated<br />

value (dew-point, mixing<br />

ratio, etc)<br />

• Three linear analogue outputs<br />

(all measured and calculated<br />

parameters)<br />

• Jumper confi guration of analogue<br />

outputs<br />

• Simultaneous digital output<br />

(%rh and temperature)<br />

• Networkable (RS485)<br />

• 2 nd probe input (digital or analogue<br />

0…2.5V e.g. pressure)<br />

• Fully user programmable<br />

• External test socket<br />

• Optional display and keypad<br />

RS485<br />

RS485<br />

RS232<br />

An external test socket allows the connection of a HygroPalm 3 handheld,<br />

which will display the actual values of the transmitter. With the<br />

HygroPalm 3 it is also possible to adjust the digital ROTRONIC probes<br />

connected to transmitter.<br />

HygroFlex 3 Ordering Information for Standard Versions<br />

H T S 3 1 X HygroFlex 3; 4…20mA = 0…100 %rh; 0…100 °C/°C dew-point; 12…35 VDC/24 VAC power;<br />

2 probe inputs<br />

H T S 3 2 X HygroFlex 3; 4…20mA = 0…100 %rh; 0…100 °C/°C dew-point; 90...250 VAC power;<br />

2 probe inputs<br />

H T S 3 1 D HygroFlex 3; 4…20mA = 0…100 %rh; 0…100 °C/°C dew-point; 12…35 VDC/24 VAC power;<br />

2 probe inputs (1 optional); Display & Keypad<br />

H T S 3 2 D HygroFlex 3; 4…20mA = 0…100 %rh; 0…100 °C/°C dew-point; 90...250 VAC power;<br />

2 probe inputs (1 optional); Display & Keypad<br />

(see page 33 for order codes for special versions)<br />

HygroFlex 3 Standard Connection Layout<br />

Probe 1 Tuchel Power connection<br />

& analog output<br />

Test socket<br />

(Binder 712, 2 pin)<br />

Probe 2 (Option)<br />

Binder 712, 5 pin<br />

Serial connection RS232/485<br />

(Binder 763/ 5-pol)<br />

(M16 cable gland)


Display and Keypad<br />

By specifying the HygroFlex display and keypad option you gain useful<br />

functions: Local display of humidity, temperature and calculated<br />

humidity parameters such as dew-point, mixing ratio, wet-bulb.<br />

Through the keypad one can access the menu functions of the<br />

HygroFlex where the user can confi gure display settings, access the<br />

probe calibration functions, obtain a system status, select which<br />

probe to view and display serial numbers. The keypad can be locked<br />

to protect critical system and calibration settings.<br />

Order code:<br />

Digidisp-HTS<br />

(For retrofi tting non display versions)<br />

see also HygroFlex order code table<br />

Metal Housing<br />

Order code table for HygroFlex<br />

Here you can specify the full range of options and confi gurations for<br />

the various HygroFlex models.<br />

HygroFlex Options<br />

In the worst industrial environments the additional protection of a<br />

metal instrument housing helps to extend the product life. The<br />

HygroFlex optional metal housing is extremely robust and is available<br />

for all versions, with and without the display/keypad option.<br />

Ordering information: see HygroFlex order code table<br />

Radio option: (433.92 MHz)<br />

Wherever cabling is too complicated or too expensive, the radio option<br />

of the HygroFlex is a good choice. Distances up to 400 m in<br />

the fi eld or ~50 m inside buildings are bridged.<br />

HygroFlex transmitters may even be retrofi tted in the factory.<br />

Note: In some countries, radio operation is not allowed or requires<br />

a license.<br />

Order code: see table below.<br />

Other options<br />

HW3 software<br />

The HW3 software package has a comprehensive range of functions<br />

which are compatible with the HygroFlex, see chapter HW3 Software<br />

for full information.<br />

USB Adapter<br />

The USB Adaptor is used to connect the serial data cable to a USB<br />

port of a PC<br />

Order Code:<br />

12.02.1086<br />

H T S 1 1 X HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 12…35 VDC/24 VAC power<br />

H T S 2 1 X HygroFlex 2; digital outputs only; 12…35 VDC/24 VAC power; 2 probe inputs<br />

H T S 3 1 X HygroFlex 3; 4…20 mA=0…100 %rh; 0…100°C/°C dew-point; 12…35 VDC/24 VAC<br />

power; 2 probe inputs (1 optional);<br />

M Metal Housing<br />

1 12…35 VDC /24 VAC power<br />

2 90…250 VAC power<br />

X No display and keypad<br />

D Optional display and keypad<br />

/ 9 Customized version; Parameters to be specifi ed within the given limits<br />

(see technical data)<br />

R C Radio option<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

33


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

34<br />

HygroFlex Probes<br />

Fully interchangeable range of probes, simply choose the best version to suit your application. If your needs<br />

change, choose a different probe!<br />

HygroClip IW / IW1<br />

For wall mounting applications (area monitoring), lightweight construction<br />

for fast thermal response.<br />

Measurement range: 0…100 %rh, -40…85°C<br />

Accuracy: ±1 %rh/±0.2 K for IW1; ±1.5 %rh/±0.3 K for IW<br />

Probe: Delrin 25/15 mmØ<br />

Sensor protection: Wire mesh fi lter<br />

Order code:<br />

HygroClip IW1 (±1 %rh/0.2 K) with SCS certifi cate<br />

HygroClip IW<br />

Probe length: 145 mm Diameter: 15 mm<br />

HygroClip IC<br />

Cable mounted probe for fl exible installation in varied applications<br />

such as high temperatures, climatic chambers, ducts etc. Two versions<br />

are available, 100 & 250 mm probe length. Select appropriate cable<br />

length.<br />

Measurement range: 0…100 %rh, -50…200°C<br />

Probe: PPS 15 mmØ<br />

Cable: 2 m / 5 m / 10 m available on request, see below<br />

Order code:<br />

HygroClip IC1 100 mm probe<br />

HygroClip IC3 250 mm probe<br />

HygroClip IC-1/X X = 2 =^ 2 m cable<br />

X = 5 =^ 5 m cable<br />

X = 10 =^ 10 m cable<br />

Probe length: 100/250 mm Diameter: 15 mm Cable: 2 m<br />

HygroClip IM<br />

Robust stainless steel probe for duct, or through-wall installation.<br />

Suitable for use in the food industry. Select appropriate cable length.<br />

max. 200°C.<br />

Two versions are available, 120 & 270 mm probe length.<br />

Measurement range: 0…100 %rh, -50…200°C<br />

Probe: Stainless steel, 15 mmØ<br />

Cable: 2 m / 5 m / 10 m available on request<br />

Order code:<br />

HygroClip IM1 120 mm probe<br />

HygroClip IM3 270 mm probe<br />

HygroClip IM-1/X X=2 =^ 2m cable<br />

X=5 =^ 5 m cable<br />

X=10 =^ 10 m cable<br />

Probe length: 120/270 mm Diameter: 15 mm Cable: 2 m


HygroClip IE<br />

HygroFlex Probes<br />

For pressurised applications up to a maximum of 50 bar and temperatures<br />

of 100°C. Two versions are available with different threads 1⁄2" G<br />

or 1⁄2" NPT.<br />

Measurement range: 0…100 %rh, -50…100°C<br />

Probe: Stainless steel<br />

Cable: 2 m<br />

Order code:<br />

HygroClip IE-1 1⁄2" G pressure probe<br />

HygroClip IE-3 1⁄2" NPT pressure probe<br />

Screw-in probe Cable: 2 m<br />

HygroClip IC-04 / 05<br />

4/5 mm diameter probe for measurement in tight spaces such as<br />

climatic test applications, or monitoring conditions of materials.<br />

Max. 100°C<br />

Measurement range: 0...100 %rh, -40...100°C<br />

Probe: Nickel-plated brass<br />

Order code:<br />

HygroClip IC-04 4 mmØ probe with 2m cable<br />

HygroClip IC-05 5 mmØ probe with 2m cable<br />

Diameter: 5 mm Cable: 2 m<br />

HygroClip ICx with 15/25 mm probe<br />

HygroClip industrial probe with shaft diameter 15/25 mm to replace<br />

the old A-type duct probes of I-1000 and I-2000 series.<br />

No installation changes need to be made.<br />

Specifi cations are the same as for the standard HygroClip IC probes.<br />

The order codes are the same as for the standard probes, but with the<br />

extension HygroClip IC-x/15/25. The robust mechanical construction<br />

allows probe lengths up to 700 mm.<br />

Example: HygroClip IC-3/15/25 (Probe length = 250mm)<br />

Diameter: 15 mm Diameter: 25 mm Cable: 2 m<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

35


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

36<br />

SP-MSB15<br />

Metal slotted cap<br />

mounted over sensor<br />

Accessories<br />

Order code, fi lter, fi lter type, properties<br />

Function: Protects sensors against pollution and<br />

high air velocity (up to 40m/s).<br />

A fi lter is required for air velocity above 3m/s.<br />

HygroClip Industrial Probe Extension Cable<br />

Should you wish to extend the distance between the HygroFlex transmitter<br />

and probe, the extension cable AC1616 can be specifi ed with<br />

lengths up to 200m thanks to an integral signal booster.<br />

Order code:<br />

AC1616xxx Where required length xxx = 010 to 200 m, in steps<br />

of 10 m<br />

AC1619 Pair of connectors with electronics for customers<br />

own cable assembly.<br />

Probe options/fi lters/mounting hardware<br />

The robust slotted cap also functions as a fi lter holder and provides<br />

mechanical protection when the fi lter element is removed.<br />

Steel sinter fi lter SP-S15<br />

Wire mesh fi lter SP-M15<br />

Tefl on fi lter SP-T15<br />

Order code Type of fi lter Properties Max. air velocity<br />

SP-S15 Steel sinter fi lter element High level of fi ltration<br />

pore size ca. 5µ Marginal effect on response times.<br />

Not suitable for high humidity applications 40m/s<br />

SP-M15 Wire mesh fi lter element Minimal measuring delay<br />

Mesh size ca. 20-25µ Reduced fi ltration effi ciency for small particles.<br />

Suitable for high humidity applications 20m/s<br />

SP-T15 Tefl on fi lter element Good fi ltration effect<br />

pore size ca. 10µ Extends response time in low air velocity<br />

Water repellent but water vapour permeable 20m/s


ATEX 2180<br />

ATEX 2180<br />

ATEX 2180<br />

HygroClip EX<br />

HygroClip EX Digital EX Humidity and Temperature Measurement<br />

HygroClip EX is a series of probes for the measurement of humidity and temperature in hazardous areas<br />

featuring the latest digital signal processing and data transmission technology. Suitable for connection to<br />

the HygroFlex range of industrial transmitters, or for use as a stand alone 4…20 mA 2 wire transmitter, the<br />

HygroClip EX probes offer wide measurement ranges and fl exible installation options.<br />

The EX probes are based on ROTRONIC’s innovative HygroClip technology, which features a custom ASIC<br />

to provide the highest possible accuracy and features such as digital calibration and probe interchange ability.<br />

Each probe is constructed throughout from high grade stainless steel, with full IP65 protection. Each<br />

probe is fi tted with a replaceable fi lter system which protects the sensors from high air speeds, dust, grease<br />

etc.<br />

To comply with hazardous area standards, a Zener Barrier is required between the HygroClip EX probes and<br />

the HygroFlex, or when used as a 2 wire 4…20mA transmitter, between the probe and the control or monitoring<br />

system.<br />

All three probes measure over the range of 0…100 %rh thanks to the well proven Hygromer humidity sensor<br />

technology which has excellent long term stability, high tolerance to chemical contamination, and withstands<br />

exposure to condensation without any effect on calibration stability. Temperature range is dependent<br />

on the version used.<br />

HygroClip ID-EX<br />

Suitable for duct or through-the-wall installation with a robust<br />

250 x 15mm stainless steel probe. Temperature measuring range is<br />

0…100°C, provided the electronics enclosure does not exceed the Ex<br />

temperature rating (-20…40°C).<br />

Order code:<br />

HygroClip ID-EX<br />

HygroClip IC-EX<br />

Cable mounted probe for use in applications with high or low temperatures<br />

(-50…200°C) and where installation fl exibility is required.<br />

The robust stainless steel probe is available in two lengths, 120 and<br />

270 mm, and both are fi tted with a 2 m cable.<br />

Order code:<br />

HygroClip IC1-EX (120 mm)<br />

HygroClip IC2-EX (270 mm)<br />

HygroClip IW-EX<br />

For wall mounted applications with an external stainless probe<br />

(150 x 15 mm). Operating temperature: -20…40°C<br />

Order code:<br />

HygroClip IW-EX<br />

Note:<br />

The total cable length between the HygroClip EX probe and the<br />

HygroFlex transmitter must not exceed 200 m.<br />

:<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

37


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

38<br />

Digital EX Humidity Temp. Application<br />

Digital EX Humidity and Temperature Application<br />

Duct-mount probe Wall-mount probe Cable type


HygroClip EX Technical Specifi cations<br />

Specifi cations and Ordering Information<br />

Specifi cations HygroClip ID-EX HygroClip IW-EX HygroClip IC-EX<br />

Humidity measuring range 0…100 %rh<br />

Temperature measuring range -30…100°C* -20…40°C -50…200 °C<br />

Accuracy at 23°C ±1 %rh, ±0.2 K<br />

Repeatability < 0.5 %rh, 0.1°C<br />

Response Time


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

40<br />

+<br />

_ 1 2<br />

B4<br />

B3<br />

B2<br />

B1<br />

1<br />

A L M<br />

HygroFlex<br />

HygroFlex Maintenance and Calibration<br />

Probe of the<br />

intrinsically<br />

safe transmitter<br />

Probe of the<br />

intrinsically<br />

safe<br />

transmitter<br />

HygroPalm Remote Control of the HygroFlex<br />

Probe calibration<br />

Calibration device Calibration device<br />

Cable type<br />

SPB5-WIN<br />

Probe of the<br />

intrinsically<br />

safe transmitter<br />

Function HygroPalm 1 HygroPalm 2 HygroPalm 3<br />

Display the readings from any probe connected to the HygroFlex • • •<br />

Display the HygroFlex status (confi guration, serial number, etc.) N/A • •<br />

1-point adjustment of any HygroClip digital probe connected to the<br />

transmitter, using the probe connected to the HygroPalm as a reference N/A • •<br />

Access the functions (except for calculate and display) of the transmit-<br />

ter, primarily the adjust M.PT function for multi point probe calibration N/A N/A •<br />

Connecting cable required: AC1621 AC1620 AC1620<br />

HygroFlex Confi guration by direct PC connection<br />

It is possible to confi gure the HygroFlex by direct connection to the PC<br />

using the HW3 software and a connecting cable.<br />

Order Code:<br />

HygroData HTS for HygroFlex 2 and HygroFlex 3<br />

HygroData HTS1X for HygroFlex 1<br />

The HygroPalm handheld instrument<br />

can be connected to the<br />

HygroFlex, and depending on<br />

the version of the HygroPalm<br />

used, various tools and functions<br />

are available by remote control<br />

(see table below).<br />

This feature is especially useful<br />

for HygroFlex transmitters which<br />

are not specifi ed to include the<br />

display and keypad option.


Mounting plate of the Transmitter Enclosure<br />

The HygroFlex is comprised of 5 parts:<br />

1 mounting bracket<br />

2 electronics housing<br />

3 main circuit board<br />

4 connector plate<br />

5 front cover with or without optional display and keypad<br />

1<br />

2<br />

4<br />

To attach the transmitter to a mounting surface:<br />

1 Attach the mounting bracket to the mounting surface using<br />

4 screws as shown below.<br />

2 Slide the electronics housing down on the wall plate to the mechanical<br />

stop.<br />

80 mm<br />

3<br />

80 mm<br />

HygroFlex Installation<br />

5<br />

4x Ø3…5<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

41


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

42<br />

HygroFlex<br />

Dimensional diagrams & electrical connections<br />

Dimensions of housing Dimensions of mounting plate<br />

12 to 35 VDC or 12 to 24 VAC supply voltage and voltage output signals<br />

TB1 (1) 12…35 VDC (-) or 12…24 VAC Neutral TB2 (1) Relative humidity (+)<br />

TB1 (2) 12…35 VDC (+) or 12…24 VAC Phase TB2 (2) Temperature (+)<br />

TB1 (3) Ground TB2 (3) Calculated Parameter (+)<br />

TB2 (4) Common (-)<br />

90…264 VAC with optional power module and current output signals<br />

TB1 (1) Neutral 90…264 VAC TB2 (1) Relative humidity (+)<br />

TB1 (2) Phase 90…264 VAC TB2 (2) Temperature (+)<br />

TB1 (3) Ground TB2 (3) Calculated Parameter (+)<br />

TB2 (4) Common (-)


HygroFlex Technical Data<br />

Specifi cations HygroFlex 1 HygroFlex 2 HygroFlex 3<br />

Inputs<br />

Probe connections<br />

(combined %rh/°C) 1 2 2<br />

Signal input digital or analogue: 0…2,5 V, 10 Bit A/D, 15 V DC, max. 10 mA supply<br />

Third party probe input<br />

(1 analogue) No Yes Yes<br />

Outputs<br />

Analogue outputs 2 No 3<br />

Type of output analogue 0…1 V, 0…5 V, 0…10 V, No 0…1 V, 0…5 V, 0…10 V,<br />

(jumper selectable) 0…20 mA or 4…20 mA 0…20 mA or 4…20 mA<br />

RS232 output<br />

No Yes Yes<br />

Networkable, RS485 (up to 32 units) No Yes Yes<br />

Adjustment of probes<br />

1 point %rh, °C/°F Yes, with display/keypad option<br />

4 points %rh, 2 points °C/°F Yes, with display/keypad option<br />

4 points %rh, 2 points °C/°F,<br />

via PC No Yes Yes<br />

Test connector for communication<br />

with HygroPalm handheld Yes Yes Yes<br />

Calculation & Unit Display<br />

Calculated humidity values; No full range of calculated values including Dew-point,<br />

display and output wet-bulb, enthalpy, mixing ratio, water vapour pressure,<br />

sturation vapour pressure. User defi ned scale.<br />

Pressure compensation<br />

for calculated values No Manual or automatic with optional pressure probe<br />

Technical Data (included probes)<br />

Measuring range Probe dependent, 0…100 %rh, -50…200°C, 0…2000 hPa<br />

Accuracy at 23°C ±1,5 %rh, ±0,3 K<br />

Reproducibility Better than 0.5 %rh/ 0.1°C<br />

Sensors Hygromer IN-1 (rel. humidity), Pt100 1/3 DIN (Temperature)<br />

Electronic operating range 0…100%rh (not condensed), -40…60°C, with display -30…60°C<br />

Display/Keypad (Option) Liquid Crystal 3 line numeric<br />

Display resolution (Option) 0.1 %rF, 0.1°C, 0.01 calculated value<br />

Housing, dimensions IP65, ABS, 207 x 150 x 58,3 mm, Metal housing optional<br />

Weight 310 g<br />

Supply voltage Standard 12…35 V DC (140 mA), 12…24 V AC<br />

Optional 90…250 V AC, 3,5 VA<br />

Electrical connections M16 cable gland (7 mm cable)<br />

Connection terminals18 AWG<br />

Analogue output Current ouput (0/4…20 mA), max. load 500 Ω, others are jumper selectable<br />

(Factory setting 4…20 mA) Voltage (0…1, 5, 10 V),<br />

min. load 1000 Ω,<br />

CE-Conformity Complies to norms: EN50081-2, EN50082-2<br />

Order code table for HygroFlex<br />

Here you can specify the full range of options and confi gurations for<br />

the various HygroFlex models.<br />

H T S 1 1 X HygroFlex 1; 4…20 mA=0…100 %rh; 0…100 °C; 12…35 VDC/24 VAC power<br />

H T S 2 1 X HygroFlex 2; digital outputs only; DC/24 VAC power; 2 probe inputs<br />

H T S 3 1 X HygroFlex 3; 4…20 mA=0…100 %rh; 0…100°C/°C dew-point; 12…35 VDC/24 VAC<br />

power; 2 probe inputs;<br />

M Metal Housing<br />

1 12…35 VDC /24 VAC power<br />

2 90…250 VAC power<br />

X No display and keypad<br />

D No display and keypad<br />

/ 9 Customized version; Parameters to be specifi ed within the given limits<br />

(see technical data)<br />

R C Radio option<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

43


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

44<br />

HygroClip Alarm<br />

We have frequent requests for an alarm solution that is independent of other manufacturers control equipment,<br />

and which offers fl exible options for alarm or control. With the new HygroClip Alarm, we<br />

can now fulfi l these customer requests.<br />

HygroClip Alarm is a universal programmable alarm and control system that can either be interfaced with<br />

the HygroFlex, HygroLab and M-series instruments on an RS485 Bus, or operates independently from<br />

measurement equipment and PC’s. With four relays, it is possible to control four single alarm conditions or<br />

a block of up to 128 AND/OR linked alarms. The confi guration of the relays and the related logic array is performed<br />

with the Rotronic HW3 software to precisely meet the requirements of the user. The relays can be<br />

directly used for switching of loads up to 2500W.<br />

HygroClip Alarm may be used when connected to a PC or independently.<br />

A timer function may, for example, be used to control a ventilation system at nighttime, control opening<br />

and closing of the windows of a greenhouse, or switch lights depending on time etc.. The possible applications<br />

are extensive.<br />

Features<br />

• 4 alarm relays assigned to independent values<br />

• 1 alarm computed from up to 128 measured values (OR/AND linked)<br />

• Dew point calculation from humidity/temperature values<br />

• 2 digital inputs<br />

• 4 relay outputs (with status LED’s)<br />

• Real time clock with battery backup<br />

• Freely confi gurable internal logic, consisting of:<br />

- 12 Signal delays<br />

- 6 Flipfl ops<br />

- 12 Gates (AND / OR / XOR)<br />

- 2 Monofl ops<br />

- 1 Pulse width modulator<br />

- 2 Alarm times from the real time clock<br />

- 4 virtual keys (controlled by PC-software)<br />

- Event protocol generation by HW3Software<br />

Order code:<br />

HygroClip Alarm 1 with power supply 12…35 VDC/12…24 AC<br />

HygroClip Alarm 2 with power supply 90…250 VAC<br />

HW3 software<br />

Operation<br />

1. Query of measured values:<br />

The measurement data from a HygroFlex, HygroLab or M-series<br />

transmitter are queried via the RS485 network. If a preset alarm<br />

condition is detected, the device sets an alarm by switching on one<br />

or more relays according to the units programming. Any of the<br />

parameters measured by the instruments mentioned above can be<br />

monitored (humidity, temperature, pressure, air fl ow etc.)<br />

2. Independent control unit<br />

HygroClip Alarm may be used as an independent control unit, and<br />

as such, switch various devices. For example, switching on a ventilation<br />

unit for 10 minutes every hour. In this mode, HygroClip<br />

Alarm is completely independent of any PC or other device.<br />

3. Remote control<br />

Using HW3 software, virtual keys can be operated. This may be<br />

useful to cancel an alarm or switch a relay remotely.<br />

Note: On request, we offer a programming service for this product.


Operating modes<br />

For HygroClip Alarm, two operating modes are available:<br />

Easy and Expert modes.<br />

Easy Mode<br />

In the Easy Mode, HygroClip Alarm is confi gured using the HW3 software.<br />

The user interface allows only the most important functions,<br />

which makes programming very easy. As a maximum, 4 parameters<br />

and 2 external signals (switches) can be processed.<br />

Expert Mode<br />

HygroClip Alarm<br />

In the Expert Mode, the functions can be displayed graphically and<br />

directly programmed by dragging and dropping various logic symbols.<br />

The logic links allow very complex functions. Programming is performed<br />

directly within HW3 software and is organised in a user-friendly<br />

way.<br />

Data logging<br />

Data logging is performed by the HW3 software. All alarm events are<br />

logged together with the measured values.<br />

Even if the PC is switched off (e.g. due to power failure or at night<br />

time), HygroClip Alarm logs up to 20 events. These may be evaluated<br />

afterwards from a PC.<br />

Technical Data HygroClip Alarm<br />

Power supply 90…250 VAC or 12…35 VDC / 12…24 VAC<br />

Power consumption 50 mA (without relays)<br />

Inputs 2 digital inputs 0…5 V or switches<br />

Outputs 4 Relays (10 A @ 250 VAC/30 VDC, 12 A @ 125 VAC)<br />

Clock Real-time clock<br />

Interface RS485 interface<br />

Radio interface optional<br />

Housing material Makrolon<br />

Dimensions 160 x120 x 75 mm<br />

Electrical connections 3x M12, 5x M16 Cable glands<br />

Protection class IP65<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

45


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

46<br />

M-Series & Roline-L Series<br />

The measurement of temperature and humidity in HVAC/BMS applications becomes more demanding<br />

with almost every year. Heating, air conditioning and ventilation get more and more sophisticated. Cooled<br />

ceilings provide an agreeable atmosphere, where hardly any draught may be felt. The exchange of air in<br />

buildings is reduced to the minimum in order to save energy. The temperature and humidity values are<br />

regulated within ever-smaller margins. Obviously, the accuracy of the measuring instruments must be<br />

better than a few years ago. In such demanding environments, the measuring equipment had to compete<br />

with the demands. ROTRONIC has developed new instruments that suit the requirements of today and<br />

certainly also of the future. However, there are still other applications, where the utmost accuracy is not<br />

asked for. For these, ROTRONIC has developed a new line of economically priced instruments also: The<br />

Roline-L.<br />

The new M-Line of ROTRONIC represents the latest development in digital humidity measurement. The<br />

well known and established FT and FH series are now replaced by the new instruments, which offer much<br />

greater application fl exibility due to the fact that the output signals are scaleable. Hence, the resolution<br />

becomes better, because it is possible to scale the output of e.g. 0…10 °C to 4…20 mA. In fact, any range<br />

may be scaled exactly according to your needs. For applications in which the range of the measured values<br />

is always in a limited range, this represents a remarkable advantage. Control can be made much more effi<br />

cient and accurate. ROTRONIC provides a number of standard versions types usually from stock. However,<br />

customized instruments are available on request from your distributor.<br />

Key features<br />

• Compact, modern instruments<br />

• Optional display with good contrast<br />

• Accuracy and long term stability<br />

• Interchangeable sensor module<br />

• Scaleable output signals<br />

• All standard signals available<br />

• Aesthetic housing<br />

• Psychrometric Calculations<br />

Your benefi ts<br />

� Easy to handle and fl exible<br />

� Easy observation of measured values<br />

� Reliable data and reduced maintenance<br />

� Easy calibration & maintenance<br />

� Better resolution, more precise control<br />

� One instrument for different control systems<br />

� Use also in living spaces<br />

� No need for external calculators<br />

This section contains Page<br />

New M-Series 48 to 52<br />

� Interchangeable probes<br />

� Optional Display<br />

� Scaleable Output Signals<br />

� Psychrometric Calculations<br />

� High Accuracy<br />

� Remote Adjustment with Handheld<br />

New Roline-L Series 53 to 54<br />

� Best price-performance ratio<br />

� Fixed probe<br />

� 2x2 wire technology<br />

� Single signal use<br />

� Remote adjustment with handheld


Storage rooms<br />

Railway stations<br />

Computer/Server rooms<br />

Snow Guns<br />

M-Series Applications Overview<br />

Cold stores<br />

Libraries<br />

Museums<br />

Green houses<br />

Climate control<br />

in offi ce buildings<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

47


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

48<br />

ROTRONIC M-Series Transmitters<br />

General Description<br />

The new ROTRONIC M-series transmitters are the latest development of combined humidity / temperature<br />

transmitters, based on HygroClip technology. Output signals of 0…1 V, 0…5 V, 0…10 V, 0…20 mA or 4…<br />

20 mA are available. The M-Series consists of three models; each offering different features to suit the application<br />

needs, and with the facilities which can be reprogrammed by the customer or reseller. The main<br />

differentiation between the three M Series is as follows:<br />

M1 Humidity and temperature transmitters with fi xed probe, with electronics based on digital technology<br />

M2 Humidity and temperature transmitter with interchangeable HygroClip probes<br />

M3 Humidity, calculated humidity (e.g. dew point, enthalpy) and temperature transmitter with<br />

interchangeable HygroClip probes<br />

M1<br />

Key features<br />

• Fixed probe<br />

• Wall, space and duct mounting versions<br />

• Combined relative humidity and temperature measurement<br />

• Digital technology<br />

• Wide measuring range<br />

• Excellent long-term stability<br />

• High accuracy<br />

• Remote diagnosis with handheld instrument<br />

• Temperature range –40…60°C<br />

• Standard output signals (current / voltage)<br />

• Wire mesh fi lter provides sensor protection against<br />

dust and high air velocity.<br />

• IP rating: IP65; IP52 for space version<br />

Ordering Information Standard M1 with fi xed probes<br />

Order code Description Electrical connection Applications<br />

M12D2HT-1X Duct-mount, 0...50 °C / 0...100 %rh 2 wire 4...20 mA, 10…35 VDC<br />

M12D2HT-4X Duct-mount, -30...70 °C / 0...100 %rh<br />

M12W2HT-1X Wall-mount, 0...50 °C / 0...100 %rh<br />

M12W2HT-4X Wall-mount, -30...70 °C / 0...100 %rh<br />

M12S2HT-1X Space mount, 0...50 °C / 0...100 %rh<br />

M12S2HT-4X Space mount, -30...70 °C / 0...100 %rh HVAC Applications<br />

M12S2HT-2X Space mount, 10...40 °C / 0...100 %rh Cold Rooms<br />

M13D2HT-1X Duct-mount, 0...50 °C / 0...100 %rh 12...35 VDC/24 VAC / 4...20 mA Storage rooms<br />

M13D2HT-4X Duct-mount, -30...70 °C / 0...100 %rh 3/4 wires Semicond. Industry<br />

M13W2HT-1X Wall-mount, 0...50 °C / 0...100 %rh<br />

M13W2HT-4X Wall-mount, -30...70 °C / 0...100 %rh<br />

M13S2HT-1X Space mount, 0...50 °C / 0...100 %rh Any application, where<br />

M13S2HT-4X Space mount, -30...70 °C / 0...100 %rh probes must not be<br />

M13D5HT-1X Duct-mount, 0...50 °C / 0...100 %rh 12...35 VDC/24 VAC / 0...10 V removed or exchanged.<br />

M13W5HT-4X Wall-mount, -30...70 °C / 0...100 %rh 3/4 wires<br />

M13S5HT-1X Space mount, 0...50 °C / 0...100 %rh<br />

M13D5HT-4X Duct-mount, -30...70 °C / 0...100 %rh<br />

M13W5HT-4X Wall-mount, -30...70 °C / 0...100 %rh<br />

M13S5HT-4X Space mount, -30...70 °C / 0...100 %rh<br />

The probe length of all duct mount transmitters is 207 mm; 52 mm for wall mount types<br />

For non-standard ordering information, please see table on page 51.<br />

HW3 software<br />

The HW3 software package has a comprehensive range of functions which are compatible with the M-<br />

Series, see chapter HW3 Software for full information.


M2<br />

Humidity and temperature transmitter<br />

with interchangeable HygroClip S probes<br />

Key features<br />

• Probe interchangeable within seconds<br />

• Wall and duct mounting types<br />

• Measures humidity and temperature simultaneously<br />

• Use of digital technology<br />

• Wide measuring range<br />

• Excellent long-term stability<br />

• High accuracy ±1.5 %rh, 0.3 K<br />

• Optional display<br />

• Remote diagnosis with handheld instrument<br />

• Temperature range –40…60°C/-30…60°C with display<br />

• Wire mesh fi lter provides sensor protection<br />

against dust and high air velocity.<br />

• IP rating: IP65<br />

HygroClip Probes for M-Series transmitters<br />

HygroClip S<br />

Standard sensor module for humidity and temperature.<br />

A wire mesh fi lter provides sensor protection against dust<br />

and high air velocity. Dimensions Ø15 x 100 mm.<br />

IP rating: IP65<br />

Measurement range: -40…85 °C , 0…100 %rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23 °C)<br />

Order code:<br />

HygroClip S<br />

Extension cable with<br />

1 / 2 / 5 m cable length<br />

for HygroClip S probes and M-Series transmitters<br />

Order code:<br />

MOK-01-DAT05 1 m<br />

MOK-02-DAT05 2 m<br />

MOK-05-DAT05 5 m<br />

ROTRONIC M-Series Transmitters<br />

����<br />

���� ��<br />

Ordering Information Standard M2 with interchangeable probes<br />

Order code Specifi cation Power supply Applications<br />

M22D2HT-1X Duct-mount, 0...50 °C / 0...100 %rh 2 wire 4...20 mA, 10…35 VDC<br />

M22D2HT-4X Duct-mount, -30...70 °C / 0...100 %rh HVAC Applications<br />

M22W2HT-1X Wall-mount, 0...50 °C / 0...100 %rh Cold Rooms<br />

M22W2HT-4X Wall-mount, -30...70 °C / 0...100 %rh Storage rooms<br />

M23D2HT-1X Duct-mount, 0...50 °C / 0...100 %rh 12...35 VDC/24 VAC / 4...20 mA Semiconductor Industry<br />

M23D2HT-4X Duct-mount, -30...70 °C / 0...100 %rh 3/4 wires Light industry<br />

M23W2HT-1X Wall-mount, 0...50 °C / 0...100 %rh<br />

M23W2HT-4X Wall-mount, -30...70 °C / 0...100 %rh Any application,<br />

M23D5HT-1X Duct-mount, 0...50 °C / 0...100 %rh 15...35 VDC/24 VAC / 0...10 V where probes must<br />

M23D5HT-4X Duct-mount, -30...70 °C / 0...100 %rh 3/4 wires be easy to exchange.<br />

M23W5HT-1X Wall-mount, 0...50 °C / 0...100 %rh<br />

M23W5HT-4X Wall-mount, -30...70 °C / 0...100 %rh<br />

The probe length of all M2 standard duct-type transmitters is 250 mm; 100 mm for wall mount types.<br />

Order Codes Non-Standard Types M2 –please see table on page 51<br />

�� �<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

49


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

50<br />

����<br />

���� ��<br />

�� �<br />

ROTRONIC M-Series Transmitters<br />

Ordering Information Standard Types M3 with Calculations &<br />

interchangeable Probes<br />

Order code Specifi cation Power supply Applications<br />

M33D2TC-4XW09 Duct-mount<br />

-30...70°C, -25...25°C / Dew-Point<br />

M33D2TC-4XW0B Duct-mount<br />

-30...70°C, -50...50°C / Dew-Point<br />

M33D2TC-4XW24 Duct-mount<br />

-30...70°C, 0...100 kJ/kg / Enthalpy 12...35 VDC/24VAC / 4...20 mA Snow Guns<br />

M33D2TC-4XW53 Duct-mount 3/4 wires Drying processes<br />

-30...70°C, 0...50 g/kg / Mixing Ratio (R)<br />

M33D2TC-4XW54 Duct-mount<br />

-30...70°C, 0...100 g/kg / Mixing Ratio (R)<br />

Wall mount-types are available on request;<br />

see order code table on next page<br />

M3<br />

The probe length of all M3 standard duct-type transmitters is 250 mm; 100 mm for wall mount types.<br />

Order Codes Non-Standard Types M3 – please see table on page 51.<br />

Humidity, calculated humidity (e.g. dewpoint, enthalpy) and temperature<br />

transmitter with interchangeable HygroClip S probes<br />

Key Features<br />

• Psychrometric calculations available (dewpoint, enthalpy etc.)<br />

• Probe interchangeable within seconds<br />

• Wall- and duct-mounting types<br />

• Measures humidity and temperature simultaneously<br />

• Use of digital technology<br />

• Large measuring range<br />

• Excellent long-term stability<br />

• High accuracy<br />

• Optional display<br />

• Remote diagnosis with handheld instrument<br />

• Temperature range –40…60°C; -30…60°C with display<br />

• Wire mesh fi lter provides sensor protection<br />

against dust and high air velocity.<br />

• IP rating: IP65<br />

HygroClip Probes for M-Series transmitters<br />

HygroClip S<br />

Standard sensor module for humidity and temperature.<br />

A wire mesh fi lter provides sensor protection against dust<br />

and high air velocity. Dimensions: Ø15 x 100 mm.<br />

IP rating: IP65<br />

Measurement range: -40…85°C , 0…100 %rh<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip S<br />

Extension cable with<br />

1 / 2 / 5 m cable length<br />

for HygroClip S probes and M-Series transmitters<br />

Order code:<br />

MOK-01-DAT05 1 m<br />

MOK-02-DAT05 2 m<br />

MOK-05-DAT05 5 m


Order Codes Non-Standard M Series<br />

ROTRONIC M-Series Transmitters<br />

Specifi cation 1 2 3 4 5 6 7 8 9 10 11 12 13<br />

Type M1 & M2 Integrated probe M 1 -<br />

Interchangeable probe 2<br />

Type of connection 2-wire 4...20 mA 2<br />

12...35 VDC, 24 VAC 3/4 wire 3<br />

Mounting Duct D<br />

Wall W<br />

Space S (M1 only)<br />

Output signal type 0...20 mA 1<br />

4...20 mA 2<br />

0...1 V 3<br />

0...5 V 4<br />

0...10 V 5<br />

Output parameters Humidity & temperature H T<br />

Humidity only H X<br />

Temperature only X T<br />

Output range 0…50°C / 0…100 %rh - 1<br />

Temperature & humidity 10…40°C / 0…100 %rh 2<br />

-40…60°C / 0…100 %rh 3<br />

-30…70°C / 0…100 %rh 4<br />

-40…85°C/ 0…100%rh 5<br />

0…100°F 6<br />

Options Display (not for M1) D<br />

No Display X<br />

Specifi cation 1 2 3 4 5 6 7 8 9 10 11 12 13<br />

Type M3 Interchangeable probe & calculation M 3<br />

Type of connection 12...35 VDC, 24 VAC 3/4 wire 3<br />

Mounting Duct D<br />

Wall W<br />

Output signal type 0...20 mA 1<br />

4...20 mA 2<br />

0...1 V 3<br />

0...5 V 4<br />

0...10 V 5<br />

Output parameters Humidity & calculated value H C<br />

Temperature & calculated Value T C<br />

Output range -30…70°C / 0…100 %rh - 4<br />

Temperature & humidity 0…100°F / 0…100 %rh 6<br />

Options Display D<br />

No display X<br />

Standard wire communication W<br />

Radio communication (M3 only) R<br />

Calculated parameter Dew-Point Dp in °C 0<br />

Wet-Bulb temperature Tw in °C 1<br />

Enthalpy H in kJ/kg 2<br />

Mixing ratio R in g/kg 5<br />

Output range 0…20 1<br />

Calculated value 0…25 2<br />

0…50 3<br />

0…100 4<br />

0…200 5<br />

0...500 6<br />

0...1000 7<br />

-20...20 8<br />

-25...25 9<br />

-40…40 A<br />

-50…50 B<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

51


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

52<br />

Technical Data Summary M-Line<br />

Features M 1 M 2 M 3<br />

Humidity sensor AC-1<br />

Temperature sensor Pt100 B Pt100 1/3 DIN<br />

Probe connections (combined %rh/°C) Fixed probe 1 for exchangeable HygroClip probes<br />

RS232 Service Interface Yes, by HygroPalm<br />

Display No Option<br />

Display units %rh, °C, °F, calculated parameters (M3 only)<br />

Resolution 0.1 %rh / 0.1°C<br />

Output signal type 0…1/5/10 V; 0/4…20 mA<br />

Trend indicator No Yes, with display option<br />

RS485 vernetzbar No Option<br />

Radio transmission No Option<br />

Serial number stored in EE-Prom Yes<br />

Scaleable analogue outputs Yes, with HW3 Software<br />

Remote Functions with HygroPalm<br />

1 point %rh, °C probe adjustment Yes<br />

4 point %rh, 2 point °C probe adjustm. Yes<br />

Reference adjustment Yes<br />

Calculation & Unit Display<br />

Psychrometric calculations No Yes<br />

Pressure compens. of calculated values No Possible with HW3 Software<br />

Standard pressure constant value No 1013.25 hPa<br />

Remote Transmitter Control<br />

Transmitter adjustment 1 point 1 point Multiple points<br />

Transmitter adjustment against<br />

reference probe Yes, with HygroPalm<br />

Transmitter measurement display Yes, with HygroPalm<br />

Transmitter status display Yes, with HygroPalm<br />

Operating range<br />

Operating range of electronics -40…60°C, with display -30…60°C<br />

Measuring Ranges (probes)<br />

Humidity 0…100 %rh<br />

Temperature Probe dependent; max. –40…100°C<br />

Accuracy at 23°C ±1.5%rh /± 0.3 K<br />

Reproducibility < 0.5%<br />

Long term stability < 1%rh / year<br />

Electrical Data<br />

Power supply 10(15)…35 VDC / 12…24 VAC or 2 wire 4…20 mA, 10…35 VDC<br />

Maximum load Current Output: < 250 Ohm; Voltage Output > 1000 Ohms<br />

Automatic load compensation No Yes<br />

Electrical connection Screw terminals on connection plate<br />

Mechanical Data<br />

Type of enclosure/ IP rating IP 65<br />

Sensor protection Type SP-W15 Wire mesh fi lter, stainless steel<br />

Housing material ABS<br />

Probe length/diameter for<br />

Duct type / Wall type 207/15/52/15 mm 250/15 mm/100 /15 mm<br />

Dimensions 154 x 73 x 48 mm<br />

Weight Ca. 300 g<br />

Schematics and dimensional diagrams see page 55 + 57


Roline-L Series Transmitters<br />

The Roline L transmitter has been designed for cost sensitive applications where the highest accuracy or<br />

widest measuring ranges are not required. Two versions are available, 2 wire 4…20mA loop and 3/4 wire<br />

formats for current and voltage signals.<br />

L12<br />

• 2 wire or 2x2 wire loop powered 4…20 mA<br />

• Integrated probe<br />

• Duct and wall mounting versions<br />

• Combined humidity and temperature measurement<br />

• Humidity or temperature only versions<br />

• Use of digital technology<br />

• Excellent long-term stability<br />

• Good accuracy<br />

• Temperature range 5…50°C<br />

• Humidity range 10…100%rh<br />

L13<br />

• 3/4 wire model for 10…35 VDC /12…24 VAC supply<br />

• 4…20 mA, 0…20mA, 0…10 V outputs<br />

• Integrated probe<br />

• Duct and wall mounting versions<br />

• Combined humidity and temperature measurement<br />

• Humidity or temperature only versions<br />

• Use of digital technology<br />

• Excellent long-term stability<br />

• Good accuracy<br />

• Temperature range 0…50°C<br />

• Humidity range 0…100 %rh<br />

Ordering Information Standard Versions Roline L<br />

Key features<br />

Roline-L Serie<br />

The transmitters that are defi ned in the table below represent the most popular versions.<br />

Customized versions may be ordered according to the table on the next page.<br />

• Compact, modern instruments<br />

• Good long term stability<br />

• All standard output signals<br />

available<br />

• Aesthetic housing<br />

Your benefi ts<br />

� Easy to install<br />

� Reliable data and reduced<br />

maintenance<br />

� Compatible with most control<br />

systems<br />

� Suitable for public areas<br />

Orde code Description Supply / Output Applications<br />

L12DHT2 Duct-mount, 0…50°C / 0…100 %rh 2-wire 4…20 mA ; 10…28 VDC HVAC applications,<br />

low installation costs<br />

L12DHX2 Duct-mount, 0…100 %rh Humidity measurem. only<br />

L12DTX2 Duct-mount, 0…50°C Temp. measurement only<br />

L12WHT2 Wall mount, 0…50°C / 0…100 %rh HVAC applications,<br />

low installation costs<br />

L12WHX2 Wall mount, 0…100 %rh Humidity measurem. only<br />

L12WTX2 Wall mount, 0…50°C Temp. measurement only<br />

L13DHT2 Duct-mount, 0…50°C / 0…100 %rh 3/4-wire 4…20 mA; HVAC applications,<br />

10 (15)…35 VDC; 12…24 VAC low installation costs<br />

L13DHX2 Duct-mount, 0…100 %rh Humidity measurem. only<br />

L13DTX2 Duct-mount, 0…50°C Temp. measurement only<br />

L13WHT2 Wall mount, 0…50°C / 0…100 %rh HVAC applications,<br />

low installation costs<br />

L13WHX2 Wall mount, 0…100 %rh Humidity measurem. only<br />

L13WTX2 Wall mount, 0…50°C Temp. measurement only<br />

L13DHT5 Duct-mount, 0…50°C / 0…100 %rh 3/4-wire 0…10 V; HVAC applications,<br />

10 (15)…35 VDC; 12…24 VAC low installation costs<br />

L13DHX5 Duct-mount, 0…100 %rh Humidity measurem. only<br />

L13DTX5 Duct-mount, 0…50°C Temp. measurement only<br />

L13WHT5 Wall mount, 0…50°C / 0…100 %rh HVAC applications,<br />

low installation costs<br />

L13WHX5 Wall mount,, 0…100 %rh Humidity measurem. only<br />

L13WTX5 Wall mount,, 0…50°C Temp. measurement only<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

53


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

54<br />

Roline-L Series Transmitters<br />

Ordering Information & dimensional diagrams Roline-L Series<br />

Features 1 2 3 4 5 6 7<br />

Roline-L types with integrated probes L 1<br />

Type of connection 2 wire loop power 4...20 mA 2<br />

12*...35 VDC, 3/4 wire 3<br />

Mounting Duct (Probe length 205 mm) D<br />

Wall ( Probe length 55 mm) W<br />

Output Parameters Humidity & Temperature H T<br />

Humidity only H X<br />

Temperature only T X<br />

Output Signal Type 0...20 mA (not for L12) 1<br />

* for 0/4…20 mA and 0…10 V outputs<br />

4...20 mA 2<br />

0...1 V (not for L12) 3<br />

0...5 V (not for L12) 4<br />

0...10 V (not for L12) 5<br />

Technical Data Summary Roline-L Series<br />

Specifi cations L 12 L13<br />

Humidity sensor Hygromer AC-1<br />

Temperature sensor Pt 100 B<br />

Output signal type 2 x 2 wire 4…20 mA loop power 0…1/5/10 V; 0/4…20 mA<br />

Probe adjustment In conjunction with HygroPalm handheld instrument<br />

Operating & measuring ranges<br />

Humidity 0…100 %rh, non condensing<br />

Temperature -40…60°C<br />

Air speed duct type 20 m/s max.<br />

Temperature compensation Yes<br />

Accuracy at 23°C ±3 %rh; ±0.5 K<br />

Reproducibility < 0.6 %rh / 0.5 K<br />

Long Term Stability < 1.5 %rh/Year<br />

Power Supply 2 wire 4…20mA loop power; 10…28 VDC 10(15)…35 VDC<br />

Power consumption Max. 20 mA /output < 50 mA<br />

Max. load


M-Series & Roline-L Series<br />

ACML 232<br />

ACRL<br />

ACRLXB5<br />

ACRLYB5<br />

Schematics and dimensional diagrams<br />

Schematic diagrams 3/4 wire supply 2 or 2x2 wire supply<br />

Service cable<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

55


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

56<br />

The I-1020 series has been ROTRONIC’s best selling product for industrial applications for many years, and<br />

is still in great demand, especially in 2x2 wire loop power applications. This is why ROTRONIC still produces<br />

the I-1020 despite of the availability of the HygroFlex series. Its high precision, reliability and extensive<br />

range of confi guration options make it ideally suited to the most stringent demands of the industrial sector.<br />

Ø 25 Ø 15<br />

A B<br />

L<br />

A = 150 mm<br />

B = 100 / 250 / 400 / 550 mm<br />

L = 250 / 400 / 550 / 700 mm<br />

L<br />

Ø 15<br />

(130 mm to 80 °C)<br />

L = 100 / 130 / 250/400/<br />

550 / 700 mm<br />

Cable lengths 1 m / 2 m<br />

L<br />

(130 mm to 80 °C)<br />

Cable lengths 1 m / 2 m<br />

L<br />

L = 120 / 270 / 420 mm<br />

Transmitter I-1020<br />

L<br />

L = 100 mm<br />

Ø15 mm<br />

L = 100 / 130 / 250 / 400/<br />

550 / 700 mm<br />

Ø15 mm<br />

I-1020<br />

Key features<br />

• Excellent precision and long-term stability<br />

• Wall, duct or cable mounting<br />

• Measurement of relative humidity & temperature<br />

• Wide operating ranges: 0…100 %rh, -50…150°C<br />

• 2x2 wire loop power output : 4…20 mA<br />

Probes<br />

Passive PPS probe with sealed cable, used for all three mounting confi<br />

gurations.<br />

Advantage: No hollow spaces, therefore no possibility of leakage or<br />

trapped condensation. Various combinations of transmitters<br />

and probes are available for the different demands<br />

in all types of applications<br />

Wall mount type P<br />

Temperature range: -20...50°C<br />

Length: 100 mm<br />

Probe: PPS, sealed against condensation<br />

Duct Mount Type A<br />

Standard probe length: 250 mm<br />

Temperature range: -50…150°C<br />

Probe: PPS, sealed against condensation<br />

Duct Mount Type P<br />

Standard probe length: 250 mm<br />

Temperature range: -50…150°C<br />

Probe: PPS, sealed against condensation<br />

Cable mount type P<br />

Temperature range: -50…150°C<br />

Probe: PPS, sealed against condensation<br />

Cable lengths: 1 or 2 m<br />

Cable mount type M (option)<br />

Temperature range: -50…150°C<br />

Probe: Steel V2A<br />

Cable lengths: 1 or 2 m<br />

Length: 120 / 270 / 420 mm<br />

Diameter: 15 mm


Sensor protection, fi lters<br />

M-Series Schematics Model M3 with calculation<br />

M1 M2 + M3<br />

I-1020 Sensor protection, fi lters<br />

The robust slotted cap also functions as a fi lter holder and provides mechanical protection when the fi lter<br />

element is removed.<br />

SP-MSB15<br />

Metal slotted cap<br />

mounted over sensor<br />

Order code, fi lter, fi lter type, properties<br />

Function: Protects sensors against pollution and<br />

high air velocity (up to 40 m/s).<br />

A fi lter is required for air velocities from 3 m/s.<br />

Steel sinter fi lter SP-S15<br />

Wire mesh fi lter SP-M15<br />

Tefl on fi lter SP-T15<br />

Order code Type of fi lter Properties Max. air velocity<br />

SP-S15 Steel sinter fi lter element High level of fi ltration<br />

pore size ca. 5µ Marginal effect on response times<br />

Not suitable for very high humidity applications 40m/s<br />

SP-M15 Wire mesh fi lter element Minimal measuring delay<br />

Mesh size ca. 20–25µ Reduced fi ltration effi ciency for small particles.<br />

Suitable for high humidity applications 20m/s<br />

SP-T15 Tefl on fi lter element Good fi ltration effect<br />

pore size ca. 10µ Extends response time in low air velocity<br />

Water repellent but water vapour permeable 20m/s<br />

Power Supply<br />

+ 1 Supply, max. 35 V DC, 24 V AC<br />

– 2 GND (common)<br />

+ 3 Temperature [V, mA]<br />

+ 4 Calculated value [V, mA]<br />

+ 5<br />

] RS485<br />

– 6<br />

Dimensional Diagrams M-Series<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

57


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

58<br />

I-1020<br />

Order code table series I-1020<br />

Parameter column number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18<br />

Example: 1 - 1 0 2 2 C C 0 2 P 3 C W 1 V 1 X<br />

Supply voltage: 2x2 wire 4…20 mA 2<br />

Temperature measuring range<br />

No temperature measurement 0 T<br />

0…50°C 1 C<br />

0…100°C 2 C<br />

0…150°C 3 C<br />

–30…70°C 4 C<br />

other in °C 9 C<br />

0…10°F 1 F<br />

0…200°F 2 F<br />

other in °F 9 F<br />

Type of mounting<br />

Wall (100 mm probe length) W X X<br />

Duct R X X<br />

Cable-probe 1 m (incl. probe) C 0 1<br />

Cable-probe 2 m (incl. probe) C 0 2<br />

Probe type<br />

PPS probe type A 25/15 mm Ø A<br />

PPS probe type P 15 mm Ø P<br />

Metal probe 15 mm Ø (Cable type only) M<br />

Probe length<br />

Mounting type W and C: 100 mm<br />

Metal probe: 120 mm Not available for probe type A 1<br />

Mounting type R und C: 130 mm (up to 80°C) Not available for probe type A 2<br />

Mounting type R und C: 250 mm Metal probe: 270 mm 3<br />

Mounting type R und C: 400 mm Metal probe: 420 mm 4<br />

Mounting type R und C 550 mm 5<br />

Mounting type C 700 mm 7<br />

Measured parameter<br />

Humidity & Temperature measurement C W<br />

Temperature measurement only C T<br />

Output signal:<br />

Current: 4…20 mA, 2 wire 6 A<br />

Current: 2x4…2 0mA, 2x2 wire 8 A<br />

Cable connections:<br />

1 M16 cable gland 1<br />

Tuchel plug 7 pin 7<br />

Special version 9 X<br />

Filter options<br />

to be ordered separately<br />

Order code:<br />

SP-S15 Steel sinter fi lter element<br />

SP-M15 Wire mesh fi lter element<br />

SP-T15 Tefl on fi lter element<br />

Service cable for adjusting of the transmitters<br />

Order code:<br />

ET-86.1708.0501


Technical data series I-1020<br />

Humidity sensor HYGROMER ® IN-1<br />

Temperature sensor Pt100 1/3 DIN<br />

Operating range<br />

Humidity 0…100 %rh<br />

Temperature (sensor) -50…150°C<br />

Temperature (Electronics) -20…50°C<br />

Technical data series I-1020<br />

Air velocity Without fi lter up to 3m/s, with fi lter up to 40m/s<br />

Measuring range<br />

Humidity 0…100 %rh<br />

Temperature See order code table<br />

Temperature compensation: Within temperature range 0…100°C<br />

Output signals humidity and temperature 2-wire loop power 4…20 mA<br />

Accuracy humidity at 23 ±2°C Humidity ±1.5 %rh, 0…100 %rh<br />

Temperature ±0.3 K<br />

Reproducibility 0.5 %rh, 0.1 K<br />

Long-term stability


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

60<br />

Dimensions of the electronics housing<br />

I-1020<br />

Order codes Screw fi tting Probe Ø max. temperature AG H (mm) Flange<br />

AC1301 Perbunan 15 mm 100 °C 1⁄2"G 28 AC 1305<br />

AC1301-M* Perbunan 15 mm 100 °C M 25 x 1.5 26 On request<br />

AC1302 Perbunan 25 mm 100 °C 1"G 33 AC 1306<br />

AC1302-M* Perbunan 25 mm 100 °C M 32 x 1.5 31.5 On request<br />

AC1303 Viton 15 mm 200 °C 1⁄2"G 28 AC 1305<br />

AC1303-M* Viton D 15 mm 200 °C M 25 x 1.5 26 On request<br />

AC1304 Viton 25 mm 200 °C 1"G 33 AC 1306<br />

AC1304-M* Viton 25 mm 200 °C M 32 x 1.5 31.5 On request<br />

* M = Metric thread<br />

I-1020<br />

Fitting Flange Version B<br />

Remark:<br />

The dimensions in brackets apply to probes with 25 mm Ø.<br />

Aluminium housing<br />

on request<br />

Mounting accessories for all transmitters with 15 mm probes<br />

1. Wall mounting: no accessories required. Electronics housing mounted on wall.<br />

2. Duct mounting:<br />

A: Electronics housing mounted on air duct. No accessories required<br />

B: Probe mounted by AGRO screw fi tting and fl ange ( Duct and cable types)<br />

The fl ange is only required, if the AGRO screw fi tting cannot<br />

be fi xed alone; e.g in small ducts with no access


Installation of ROTRONIC transmitters is easy. The various models can be mounted either by a mounting<br />

plate, onto which the whole transmitter is fi xed, by a connecting plate, which is screwed onto the wall or<br />

duct, or by direct mounting onto a duct by fi xing the probe with an AGRO fi tting. See also previous page.<br />

Mounting of M-Series Transmitters<br />

1. Mount the base/mounting<br />

plate onto the wall and connect<br />

the wiring.<br />

2. Plug in the probe/electronics<br />

module<br />

The base/mounting plate is<br />

absolutely identical to the old<br />

versions of the FTW65, DPT and<br />

FH types.<br />

The M1 space mount version<br />

features a retractable probe.<br />

This is especially convenient for<br />

calibration. In areas with no air<br />

movement, the measurement is<br />

much more accurate due to the<br />

better adaptation to the temperature.<br />

Mounting of Roline-L Types<br />

Fix the housing by screwing it directly<br />

onto the wall, or by means<br />

of an AGRO fi tting.<br />

Mounting of I-1020 types<br />

52<br />

52<br />

Installation and Maintenance<br />

M1 M2 + M3<br />

The I-1020 type can be screwed onto a duct or wall by 4 screws located<br />

inside of the housing, or by an AGRO fi tting in the same manner as<br />

M-series or Roline-L series. Fixing by means of a screw-fi tting is also<br />

possible.<br />

Maintenance<br />

ROTRONIC transmitters require hardly any maintenance. Due to the<br />

excellent long term stability, a calibration interval of one year will be<br />

suffi cient in most cases. However, in some applications, it may be<br />

advisable to perform more than one calibration per year. For detailed<br />

calibration information, please refer to the chapter calibration.<br />

In dusty and otherwise polluted environments, the sensor protection<br />

fi lters require some maintenance. We recommend to have a spare<br />

fi lter ready and to exchange it on site. The replaced fi lter may be<br />

cleaned in the workshop with soap and water. Ultrasonic cleaners may<br />

also be used. Let the fi lter dry thoroughly before re-use.<br />

40<br />

40<br />

ø82<br />

90<br />

101<br />

ø82<br />

90<br />

101<br />

ø15<br />

ø15<br />

~155<br />

~155<br />

18.5<br />

18.5<br />

~43<br />

~43<br />

40<br />

40<br />

207<br />

Probe<br />

Sensors<br />

207<br />

ø15<br />

ø15<br />

~40<br />

~40<br />

Electronic<br />

housing<br />

Sensors<br />

ø82<br />

~103<br />

ø82<br />

~103<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

61


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

62<br />

What is the HygroClip?<br />

HygroClip Introduction<br />

The HygroClip ® is a high quality probe for the measurement of humidity and temperature.<br />

It is used in a wide range of applications including handheld instruments, data-loggers and transmitters. It<br />

provides digital and analogue output signals for both temperature and humidity. The humidity is measured<br />

in the range of 0…100%rh, corresponding to 0…1V; the temperature between either –40…85°C =<br />

-0.4…0.85 V, or –40…60°C = 0…1V. The two versions are distinguishable by different colours of the housing<br />

material. The digital one-wire data signal is ideally suited for OEM applications. The probes may<br />

be adjusted digitally by either software or handheld instruments. Calibration data is stored in an EE-Prom.<br />

Thus, the probes may be used in any ROTRONIC display instrument or transmitter and even in OEM instruments<br />

without the need for on-site adjustment. ROTRONIC offers an exchange service for the HygroClip<br />

probes. Every refurbished HygroClip comes with a new sensor, fully calibrated and with a factory certifi cate.<br />

Make use of the experience of ROTRONIC, and the revolutionary advantage of exchangeability. Being the<br />

fi rst supplyer in the world-wide market, we already satisfi ed the needs of thousands of customers. In continuous<br />

contact with our customers, we expand the advantages of the products to the benefi t of our customers.<br />

Key features<br />

• Simple replacement within seconds<br />

• No on-site adjustment necessary<br />

• Global availability from stock<br />

• Digital output signal<br />

• Analogue interface<br />

• Wide range of supply voltage<br />

OEM applications and advantages<br />

Your benefi ts<br />

� Negligible down-time; reduction of servicing costs<br />

� No specifi c knowledge required<br />

� Available from your local dealer<br />

� High accuracy and interchange ability<br />

� Also suitable for analogue display instruments<br />

� Suitable for almost every OEM instrument<br />

The availability of digital and analogue output signals and the wide supply voltage range of 3.5 to 50 VDC<br />

makes the HygroClip suitable for a wide variety of applications. The application range of 0…100 %rh and<br />

–40 to 85°C is unique.<br />

HygroClip S is the standard-type. However, ROTRONIC is capable of manufacturing customized types according<br />

to your requirements. The HygroClip is ideally suited as an integral part of complete humidity and<br />

temperature measurement systems, such as:<br />

• Display devices<br />

• Process control applications<br />

• Multi channel data loggers<br />

• Handheld instruments<br />

• High precision climate control<br />

• Electronic cabinets<br />

• Incubators and environmental chambers<br />

• Fermentation chambers<br />

• EDP applications<br />

• Gas detection systems & portable instrumentation<br />

• Air-conditioned containers<br />

Section contains<br />

HygroClip Probe<br />

� Standard HygroClip S<br />

� HygroClip S3 for meteorological applications<br />

� Accessories for HygroClip probes


Feature Overview<br />

Universal probe for various applications<br />

Very small size-suitable for<br />

many application<br />

IP-65 protection<br />

Available for standard and<br />

meteorological application<br />

3.5...50 VDC Supply voltage<br />

OEM-types available<br />

HygroClip<br />

Replaceable sensor<br />

protection fi lter<br />

Body fi lled with resin<br />

to avoid condensation<br />

Analogue and digital<br />

interfaces<br />

Sockets with lockring<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

63


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

64<br />

HygroClip S and Accessories<br />

HygroClip S, HygroClip S3<br />

• 100% interchangeable<br />

• 1 digital output and 2 analogue outputs<br />

• ROTRONIC Hygromer humidity sensor 0…100 %rh<br />

• Accuracy ±1.5 %rh<br />

• Long-term stability better than 1 %rh/year<br />

• High precision Pt100 temperature sensor<br />

• HygroClip S3 (white) temperature range<br />

of 0…1V for –40…60°C<br />

Order code:<br />

HygroClip S (anthracite) –40…85 °C = –0.4…0.85 V<br />

HygroClip S3 (white) –40…60 °C = 0…1 V<br />

HygroClip R (standard, refurbished)<br />

HygroClip R3 (white, refurbished)<br />

MOC, MOC3<br />

• Mounting connector for HygroClip S<br />

• 30 cm connecting wires<br />

• Mounting hole 12.7 mm diameter or PG7 thread<br />

• HygroClip connector with bayonet locking ring<br />

• MOC3 in white for HygroClip S3<br />

Order code:<br />

MOC (anthracite)<br />

MOC3 (white)<br />

HygroClip SC04 / SC05<br />

• HygroClip S with miniature cable probe:<br />

Length = 51mm, diameter = 4/5mm, length of probe cable = 2m<br />

• 100% interchangeable<br />

• 1 digital and 2 analogue outputs<br />

• ROTRONIC Hygromer humidity probe 0…100 %rh<br />

• Accuracy ±1.5 %rh / ±0.3K<br />

• Long-term stability less than 1 %rh drift per year<br />

• Temperature sensor Pt100 1/3 DIN<br />

• Probe operating temperature –30 °C…100°C<br />

Order code:<br />

HygroClip SC04 4 mm Ø probe<br />

HygroClip SC05 5 mm Ø probe<br />

MOK, MOK3<br />

Passive extension cables for HygroClip S and S3 (no electronics)<br />

• 1…5m connection cable with stripped wires<br />

• 5 pin connector or DAT05 connection to extend cable length<br />

Active adapter: with integrated amplifi er<br />

• Ranges 0…1V, 0…2,5V, 0…5V, 0…10V<br />

at 0…100%rh and, for example -40…60°C<br />

• Length of connection cable up to 20m<br />

• MOK3 in white for HygroClip S3<br />

Order codes:<br />

see next page


Order codes passive MOK adaptors<br />

Order codes passive adaptors 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

Standard type (anthracite) M O K -<br />

White housing 3-<br />

Cable length: 1 m 0 1<br />

2 m 0 2<br />

5 m 0 5<br />

Stripped wires - X X<br />

Binder 5 pin connector B 5<br />

DAT05 connector (HygroClip-plug) D A T 0 5<br />

Order codes active adaptors 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Remarks<br />

Anthracite housing (Standard type) M O K -<br />

White housing 3-<br />

Cable length: 1 m 0 1<br />

2 m 0 2<br />

5 m 0 5<br />

10 m 1 0<br />

20 m 2 0<br />

Stripped wires X X<br />

Output signal Max. cable length:<br />

0…1 V (min. supply 5.5 V) - 0 0 1 V 2 m<br />

0…2.5 V (min. supply 5.5 V) 0 2 5 V 5 m<br />

0…5 V (min. supply 10 V) 0 0 5 V 10 m<br />

0…10 V (min. supply 15 V) 0 1 0 V 20 m<br />

Temperature range -<br />

0…100°C ( not possible for MOK3-XX) 1<br />

-30…70°C (not possible for MOK3-XX) 2<br />

-40…60°C 3<br />

Load: 1 kΩ/V<br />

HygroWin<br />

• Probe for direct connection to a PC<br />

• Measuring range 0…100 %rh, -40…85°C<br />

• Accuracy ±3 %rh, ±0.5 K<br />

• Comprehensive software with data storage<br />

• Low cost<br />

Order code:<br />

HygroWin<br />

MOK-WIN<br />

• Adapter cable for direct connection of HygroClip S to your PC<br />

• Cable lengths: 1m, 2m, 5m<br />

• Comprehensive software with data storage<br />

Order code:<br />

MOK-01-WIN (with 1 m cable)<br />

MOK-02-WIN (with 2 m cable)<br />

MOK-05-WIN (with 5 m cable)<br />

Note: HygroClip probe must be ordered separately<br />

Reference HygroClips<br />

Reference HygroClips generate a fi xed value for temperature und humidity<br />

in digital format. As the accuracy of digital values is absolute,<br />

the user can calibrate the system with them.<br />

HygroClip S and Accessories<br />

Order code:<br />

HygroClip-S-35RH/15C simulates 35%rh and 15°C (others on request)<br />

HygroClip-S-65RH/25C simulates 65%rh and 25°C<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

65


T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

66<br />

HygroClip S and Accessories<br />

HPH Signal Booster<br />

• Allows cable lengths up to 99 m<br />

• Cable length compensation, therefore no measuring errors when<br />

using long cables<br />

• ROV interface (10 mV/ %rh, 10 mV/ °C, 0 %rh, 0°C = 0V)<br />

Ordering information HPH<br />

Order code Description<br />

Technical data of the HPH signal booster<br />

Outputs Humidity 0…100 %rh = 0…1 V<br />

HPH-CG05B5 Booster, 5 m connecting cable with Binder 5 pin connector<br />

HPH-CG99B5 Booster, conn. cable up to 99m selectable, Binder 5 pin conn.<br />

HPH-CG05XX Booster, 5 m connecting cable, stripped wires<br />

HPH-CG99XX Booster, connecting cable up to 99m selectable, stripped wires<br />

Temperature -40…85°C= 0.4…0.85 V<br />

Cable length 5…99 m<br />

Cable compensation Up to 99 m<br />

Connecting cable Open terminations or 5 pin connector<br />

HygroClip Technical data, Order Information<br />

Supply voltage HygroClip 3.5…50 VDC<br />

Current consumption HygroClip Ca. 4 mA<br />

Operating range Humidity /Temperature 0…100 %rh / -40…85°C<br />

Accuracy at 23 °C Humidity /Temperature ±1.5 %rh / ±0.3 K<br />

Output signals HygroClip S Humidity /Temperature 0…100 %rh = 0…1V / -40…85°C = -0.4…0.85V<br />

HygroClip S3 Humidity /Temperature 0…100 %rh = 0…1V / -40…60°C = 0…1V<br />

Digital output signal One Wire DIO<br />

Start up time 2.7s fi rst measurement; 0.7s subsequent<br />

Resolution: Humidity 100 %rh / 12 bit analogue, 16 bit digital<br />

Temperature 250°C/12 bit analogue, 16 bit digital<br />

Adjustment Via PC (EE-Prom) or compatible instrument<br />

Sensors Humidity / Temperature Hygromer AC-1 / Pt100 1/3 DIN<br />

Output load >10 kOhm<br />

Cable length max. 5m<br />

Sensor protection Wire fi lter (max. 20m/s)<br />

Dimensions with MOC 100 x 15 mm<br />

Type of enclosure IP65<br />

Colour HygroClip S Anthracite RAL 7016<br />

HygroClip S3 White<br />

Pin and colour confi guration MOC, MOK, MOK-WIN<br />

MOC, stripped wires MOK B5 Plug HPH B5 Plug MOK-WIN<br />

Term Wire colour Pin Wire colour Pin Wire colour Term D-sub 25 plug<br />

+VDC Green 2 Green 2 Green TXD 2<br />

GND Black 3 Grey and Blue 3 Grey RXD 3<br />

Shield (GND) N/C 3 Shield N/C RTS 4<br />

Temperature Brown 1 1 Brown SG 7<br />

Humidity White 5 5 White DTR 20<br />

DIO Signal Red 4 Yellow<br />

Compensation N/A N/A N/A 4 Yellow


HygroClip<br />

HPH Signal Booster<br />

Dimensional Diagrams<br />

Pin Colour Function<br />

1 brown Temperature<br />

2 green +VDC<br />

3 black GND<br />

4 yellow DIO<br />

5 white rel. humidity<br />

Pin Colour Function<br />

1 brown Temperature<br />

2 green +VDC<br />

3 grey GND<br />

4 yellow Compensation<br />

5 white rel. humidity<br />

T<br />

R<br />

A<br />

N<br />

S<br />

M<br />

I<br />

T<br />

T<br />

E<br />

R<br />

S<br />

67


M<br />

E<br />

T<br />

E<br />

O<br />

R<br />

O<br />

L<br />

O<br />

G<br />

Y<br />

68<br />

In meteorology, the accuracy of the measurements is essential for accurate forecasting and decision-making.<br />

ROTRONIC humidity probes have an excellent reputation for providing reliable results even in the most<br />

demanding conditions where high humidity and low temperatures pervade. Our current product range<br />

offers high performance, a wide range of confi gurations and price levels compatible with any application’s<br />

demands.<br />

Especially with respect to humidity measurement, it is essential to carefully consider correct temperature.<br />

Relative humidity is very temperature dependent. In recognition of this fact, ROTRONIC has developed a<br />

range of enhancements to improve temperature effects and measurement accuracy. These include ventilated<br />

weather and radiation protection shields that provide very good shelter from rain, snow and radiation,<br />

and most importantly, improve the performance of temperature measurement.<br />

Why is correct temperature essential?<br />

In the past, temperature and humidity probes have been built into weather stations, or screens (Stevenson)<br />

usually made of wood and painted white. Despite of the white colour, the screens tended to heat up by<br />

suns radiation, and the deviation from actual temperature could be quite high. Such a deviation obviously<br />

must lead to incorrect measurement of the humidity, because relative humidity is so dependent of temperature.<br />

Example:<br />

Meteorology<br />

Assuming an absolute humidity Q of 5 g/kg, the relative humidity at 20 °C is 34.74 %rh; at 21 °C 32.66 %rh<br />

and at 19 °C 36.97 %rh. Hence, it becomes obvious that a wrong temperature must lead to a wrong humidity<br />

value.<br />

ROTRONIC ventilated weather stations minimise thermal effects and provide for better temperature accuracy,<br />

as the probe is not heating up in the sun. The airfl ow constantly cools the shield, whilst air temperature<br />

is measured at the air inlet.<br />

Key features<br />

• High accuracy and stability<br />

• Probe exchange without tools<br />

• Digital probes<br />

• Ventilated shields<br />

• Compact mounting system for<br />

various probes<br />

• Easy mounting<br />

Your benefi ts<br />

� Reliable measurement data and low maintenance costs<br />

� Saves installation and on-site costs<br />

� No on-site calibration required<br />

� Optimum temperature performance<br />

� One shield for all probe types<br />

� Saves installation and on-site costs<br />

Section contents Page<br />

Ventilated Weather Protection Shields VHTS2 70<br />

Non-Ventilated Weather Protection Shields<br />

Probe adaptors for VHTS2<br />

Analogue Meteorological Probes 71 to 75<br />

Digital HygroClip Probes<br />

MOK Adaptors for HygroClip S


Meteorology Applications<br />

ROTRONIC Weather Station for Temperature and relative Humidity<br />

Snowguns<br />

Weatherstations<br />

BMS/HVAC applications<br />

Agronomical applications<br />

Alpine observation applications<br />

Ice warning systems<br />

M<br />

E<br />

T<br />

E<br />

O<br />

R<br />

O<br />

L<br />

O<br />

G<br />

Y<br />

69


M<br />

E<br />

T<br />

E<br />

O<br />

R<br />

O<br />

L<br />

O<br />

G<br />

Y<br />

70<br />

Weather and Radiation Protection<br />

Ventilated weather/radiation protection<br />

Designed to minimise the infl uence of thermal radiation on humidity<br />

and temperature measurements. Provides optimum protection even in<br />

horizontally driving wind and rain.<br />

Key features<br />

• Easy-to-install protection shield with built-in ventilator<br />

to prevent heating-up of probe and shield<br />

• Special white paint against radiation<br />

• Probe mounting without tools<br />

• Various adaptors for different probes<br />

• 12 V or 24 V fan supply<br />

Order code: Suitable for Fan supply<br />

VHTS2-W-T7/12 MP100 / MP400 probes 12 VDC<br />

VHTS2-W-T7/24 24 VDC<br />

VHTS2-W-C/12<br />

12 VDC<br />

MPH probes<br />

VHTS2-W-C/24 24 VDC<br />

VHTS2-W-M/12<br />

12 VDC<br />

HygroClip with MOK adaptors<br />

VHTS2-W-M/24 24 VDC<br />

VHTS2-W-I/12<br />

12 VDC<br />

HygroClip industrial probe IC3<br />

VHTS2-W-I/24 24 VDC<br />

Adaptors for retrofi tting older shields with a thread in the<br />

lower end of the tube are available.<br />

Order code: Used for probe type:<br />

VHTS-X-MP1 MP100-series<br />

VHTS-X-MP4 MP400-series<br />

VHTS-X-MPH MP100H /MP400H series<br />

VHTS-X-MOK HygroClip probes with MOK adaptors<br />

VHTS-X-IC3 HygroClip IC3 probes<br />

VHTS-X-SCREW Screw for all types; must always be ordered<br />

separately<br />

VHTS2-SP Option Snow protection<br />

Weather and radiation protection shield<br />

with natural ventilation<br />

The naturally ventilated shield is recommended for applications where<br />

the accuracy is less important than in meteorology applications.<br />

Fairly good protection against radiation and precipitation with natural<br />

ventilation.<br />

Suitable for humidity and temperature probes series MP100A,<br />

MP400A, MP100H, MP400H<br />

Protects even against horizontally driving wind and rain up to 68 km/h<br />

Including probe protection tube<br />

Order code: Suitable for:<br />

AC1002/AC1012 MP100A series<br />

AC1003/AC1012 MP400A, MP100H, MP400H<br />

AC1002/AC1012/AC1015 HygroClip S<br />

AC1004 For HygroClip S3C03 probes, HygroClip S+MOK


MP100A with linear voltage output<br />

MP400A with linear current output<br />

Order codes of non-standard types MP100 & MP400<br />

Specifi cation 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />

Example: M P 1 0 1 A - T7 - W 4 W<br />

Output signals: Voltage M P 1 0<br />

Specifi cation:<br />

Humidity: 0…1 VDC = 0…100 %rh<br />

Temperature: -0.4…0.6 V=-40…60°C 1<br />

0…1 VDC= -30…70°C 2<br />

0…1 VDC=-40…60°C 3<br />

Auxiliary Pt100 for 4/4 wire connection 6<br />

Output signals: Current M P 4 0 - -<br />

Common terms for MP100 & MP400<br />

MP100A / MP400A<br />

Key features:<br />

• Accuracy and long term stability<br />

• Resistant to condensation and air-borne pollutants<br />

• Temperature operating range: -40…60°C<br />

• Temperature measurement by direct Pt100 resistance or linear<br />

analogue output<br />

• Cable length compensation circuit; no signal errors for cables up to 100m<br />

• Universal power supply 4.8…30 VDC<br />

Order codes of standard types:<br />

Humidity Range: 0…100 %rh = 0…1 V / 4…20 mA<br />

Order code Temperature range Tuchel plug Cable compensation (see page 75)<br />

MP101A-T4-W4W<br />

Tuchel 4 pin<br />

-0.4…0.6 V = -40…60°C<br />

MP101A-T7-W4W Tuchel 7 pin Yes<br />

MP102A-T4-W4W<br />

Tuchel 4 pin<br />

0…1 VDC = -30…70°C<br />

MP102A-T7-W4W Tuchel 7 pin Yes<br />

MP103A-T4-W4W<br />

Tuchel 4 pin<br />

0…1 VDC = -40…60°C<br />

MP103A-T7-W4W Tuchel 7 pin Yes<br />

MP106A-T7-W4W Direct Pt100 Tuchel 7 pin<br />

MP408A-T4-W4W 4…20 mA = -40…60°C Tuchel 4 pin N / A<br />

MP408A-CGXX-W4W<br />

4…20 mA = -40…60°C N / A<br />

0…20 mA = 0…100 %rh /Pt100, 4 wire 0<br />

4…20 mA = 0…100 %rh /Pt100, 4 wire 1<br />

4…20 mA = 0…100 %rh /2 wire, %rh only 2<br />

4…20 mA= 0…100 %rh/2 wire,/Pt100 4 wire 3<br />

0…20 mA = 0…100 %rh 0…100°C 4<br />

0…20 mA = 0…100 %rh -40…60°C 5<br />

0…20 mA = 0…100 %rh -30…70°C 6<br />

4…20 mA = 0…100 %rh 0…100°C 7<br />

4…20 mA = 0…100 %rh -40…60°C 8<br />

4…20 mA = 0…100 %rh -30…70°C 9<br />

Cable type<br />

Version: A<br />

XX = cable length in m<br />

Integrated plug: Tuchel 4 pin connector T4<br />

Tuchel 7 pin connector T7<br />

Connection cable: PUR cable, grey CG<br />

Cable length: 2m (for example) 02<br />

Cable plug: Cannon 4 pin connector C4<br />

Without plug, stripped wires 00<br />

Sensor protection: Wire fi lter<br />

Operating range: -40…60 °C<br />

Humidity sensor: IN-1<br />

M<br />

E<br />

T<br />

E<br />

O<br />

R<br />

O<br />

L<br />

O<br />

G<br />

Y<br />

71


M<br />

E<br />

T<br />

E<br />

O<br />

R<br />

O<br />

L<br />

O<br />

G<br />

Y<br />

72<br />

Order codes standard types:<br />

Order codes for non-standard probe MP100H & MP400H<br />

Specifi cation Column No. 1 2 3 4 5 6 7 8 9 10 11 12 13<br />

Basic model voltage output MP100H-<br />

Basic model current output MP400H-<br />

Without auxiliary Pt100 0<br />

With auxiliary Pt100, active signal 1<br />

With auxiliary Pt100, passive signal 2 wire 2<br />

With auxiliary Pt100, passive signal 3 wire 3<br />

With auxiliary Pt100, passive signal 4 wire 4<br />

Output signal for MP100H<br />

0…1 V = 0…100 %rh, -40…60°C = -0.4…0.6 V 1<br />

0…1 V = 0…100 %rh, -30…70°C 2<br />

0…1 V = 0…100 %rh, -40…60°C 3<br />

Output signal for MP400H<br />

MP100H / MP400H<br />

MP100H/MP400H with interchangeable<br />

HygroClip probe<br />

Humidity Range: 0…100 %rh = 0…1 V / 0(4)…20 mA, 3 m cable length<br />

Order code Temperature range Remarks<br />

MP100H-010300 -0.4…0.6 V = 40…60°C<br />

MP100H-030300 0…1 V = -40…60°C<br />

Key features:<br />

• Humidity and temperature measurement using interchangeable<br />

HygroClip sensor module (see chapter on HygroClip products)<br />

• Temperature measurement option: accurate measurement by additional<br />

direct Pt100 sensor<br />

• Temperature operating range: -40…60°C<br />

• Current or voltage output signal<br />

MP100H-130300 0…1 V = -40…60°C Auxiliary Pt100, active signal<br />

MP400H-050300 0…20 mA = -40…60°C<br />

MP400H-080300 4…20 mA = -40…60°C<br />

MP400H-180300 4…20 mA = -40…60°C Auxiliary Pt100, active signal<br />

0…20 mA = 0…100 %rh, 0…100°C (max. 60°C) 4<br />

0…20 mA = 0…100 %rh, -40…60°C 5<br />

0…20 mA = 0…100 %rh, -30…70°C 6<br />

4…20 mA = 0…100 %rh, 0…100°C (max. 60°C) 7<br />

4…20 mA = 0…100 %rh, -40…60°C 8<br />

4…20 mA = 0…100 %rh, -30…70°C 9<br />

PUR connection cable (3m standard) 0 3<br />

Maximum 99m 9 9<br />

7 pin Tuchel plug (not for 3/4 wire auxiliary Pt100) T 7<br />

Stripped wires 0 0<br />

Auxiliary temperature sensor Pt100 1/3 DIN - 0 3 D I N<br />

Pt100 1/5 DIN 0 5 D I N<br />

Pt100 1/10 DIN 1 0 D I N


HygroClip S3C03 for agricultural applications<br />

Typical applications include weather stations and data acquisition<br />

systems. Available with 3 m cable, stripped wires<br />

• Precise and stable measurement of temperature and humidity<br />

• Economical price<br />

• Confi gured for outdoor measurements<br />

• Compact dimensions<br />

• Weather protection shield available<br />

• Technical data equal to HygroClip S3, except cable<br />

Measurement range:<br />

HygroClip S3: -40…60°C, 0…100 %rh = 0…1 V<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip S3C03<br />

HygroClip S3<br />

Standard sensor module for humidity and temperature.<br />

A wire mesh fi lter provides sensor protection against dust<br />

and high air velocity.<br />

Dimensions: Ø15 x 100 mm<br />

IP rating: IP65<br />

HygroClip S3 is designed for meteo applications.<br />

Measurement range:<br />

HygroClip S3: -40…60°C, 0…100%rh = 0…1 V<br />

Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />

Order code:<br />

HygroClip S3<br />

HygroClip S3C03<br />

MOK Adaptors for Meteo Applications with HygroClip Probes<br />

The MOK adaptors provide a simple and low cost means<br />

of connecting a HygroClip probe to a 5 V signal processing<br />

device. They are used in conjunction with the weather<br />

protection shields.<br />

Output signal: 0…5 V = 0…100 %rh/-40…60°C<br />

Cable length: 5 m<br />

Supply: min. 5.5 V, max. 26.5 V<br />

Order code:<br />

MOK3-05-XX-005V-3<br />

Other types available on request. (See page 65)<br />

M<br />

E<br />

T<br />

E<br />

O<br />

R<br />

O<br />

L<br />

O<br />

G<br />

Y<br />

73


M<br />

E<br />

T<br />

E<br />

O<br />

R<br />

O<br />

L<br />

O<br />

G<br />

Y<br />

74<br />

Technical Data<br />

Technical data, MP100A, MP400A, MP100H, MP400H<br />

Series MP100A MP100H MP400A MP400H<br />

Protection (IP-rating) IP65<br />

Option: humidity only (2 wire, 3 wire) Yes N/A Yes N/A<br />

Output signal Voltage Current<br />

Supply voltage 4.8…30 VDC Min. 8 VDC +0.02 x load<br />

Power consumption:<br />

4 wire with current output N/A 50 mA 45 mA<br />

2 wire with current output N/A 20 mA<br />

4/5 wire with voltage output 6 mA 10 mA N/A<br />

3/4 wire with voltage output 3.5 mA 10 mA N/A<br />

Load >1000 Ω


Dimensional Diagrams MP100A / MP400A<br />

30<br />

25<br />

210<br />

40,5<br />

Dimensional Diagrams MP100H / MP400H<br />

Pinning of Tuchel Plugs for MP100 & MP400 Series<br />

Dimensional Diagrams<br />

MP100A-T7 MP100A-CG<br />

TUCHEL PLUG 7P<br />

HOUSING: WHITE<br />

Cable Length Compensation<br />

The integrated cable length compensation allows the use of a connection<br />

cable up to 99 m long, without an adverse affect on measurements.<br />

The additional “0” cable wire is connected according to the<br />

diagrams shown.<br />

The combination of ROTRONIC instruments with ROTRONIC cables<br />

includes the cable length compensation facility as standard.<br />

The connection from probe to display instrument consists of a 5 core<br />

cable, where the shielding may also be used for the common earth.<br />

The “0” cable compensation is connected to the common earth<br />

“GND” at the display instrument. It is possible to use the probe with<br />

a non-ROTRONIC instrument, such as a data-logger, chart recorder or<br />

controller and retain the compensation, by connecting the cable compensation<br />

“0” to the common earth “GND” of the termination point<br />

(the load).<br />

The cable compensation “0” can be connected with the common earth<br />

“GND” at the plug, if a 5core cable is extended by a 5core cable. If this<br />

is terminated by a 4pin plug, in this case the cable compensation is<br />

effective in the 5 core cable up to the 4pin plug.<br />

Probes with integrated 4 pin connector:<br />

The cable compensation is effective up to the connector.<br />

52<br />

7<br />

PG7 WITH KINK PROTECTION<br />

HOUSING: WHITE<br />

MP100H / MP400H /-0 MP100H /MP400H / 1…4<br />

Tuchel T4 Tuchel T7 MP100 Tuchel T7 Auxiliary Pt100<br />

252<br />

40,5<br />

M<br />

E<br />

T<br />

E<br />

O<br />

R<br />

O<br />

L<br />

O<br />

G<br />

Y<br />

75


W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

76<br />

Water Activity<br />

The measurement of Water Activity, or Equilibrium Relative Humidity, as it is sometimes known, is a key<br />

parameter in the quality control of any moisture sensitive product or material.<br />

ROTRONIC have designed and manufactured instruments for the measurement of Water Activity for over 30<br />

years. Our product range is based on our comprehensive application experience, which when combined with<br />

the very latest digital technology and software, offers the user the ideal combination of features, performance<br />

and competitive pricing.<br />

Water activity Contaminant<br />

a w = 0.91…0.95 most bacteria<br />

a w = 0.88 most yeast<br />

a w = 0.80 most mildew<br />

a w = 0.75 halophile bacteria<br />

a w = 0.70 osmiophile yeast<br />

a w = 0.65 xerophile mildew<br />

Key features<br />

Why is water activity measured?<br />

Water activity defi nes the active part of a product’s moisture content,<br />

or ‘free’ water. It infl uences the microbiological, chemical and enzymatic<br />

stability of perishable products such as foods, grain and seeds.<br />

The table shows typical growth thresholds below which the specifi ed<br />

contaminant cannot replicate, and therefore spoil the product. Control<br />

of water activity therefore has a signifi cant impact on shelf life.<br />

For similar reasons, water activity is equally relevant in the pharmaceutical<br />

industry where it also provides useful information regarding<br />

properties such as the cohesion of tablets, agglomeration of powders,<br />

and adherence of coatings.<br />

• Wide operating range<br />

• Aw Quick mode<br />

• High measurement precision<br />

• Long Term Stability<br />

• Interchangeable measurement stations<br />

• Multi channel display units<br />

• Validated PC analysis software<br />

Section contents: Page<br />

HygroLab Laboratory Display Units/Analysers 80<br />

� Digital technology<br />

� Multiple probes inputs<br />

� Networkable<br />

� Validated, easy to use software<br />

HygroPalm AW Portable Analysers 81<br />

� Digital technology<br />

� Integrated AW quick function<br />

� Measurement sets<br />

HygroClip water activity stations and probes 82 to 83<br />

� Wide range of measurement options to suit any application<br />

� Digital calibration<br />

� 100% interchangeable without adjustment<br />

Accessories for Water Activity measurement 84<br />

� Sample holders<br />

� Disposable sample containers<br />

Your benefi ts<br />

Water Activity Theory and reference, Technical Data 85 to 87<br />

� What is water activity?<br />

� Water activity or moisture content?<br />

� Suitable for any product or application<br />

� Results in 4…6 minutes<br />

� Reliable data every time<br />

� Reduced maintenance and calibration<br />

� Simple calibration & maintenance<br />

� 2 or 4 simultaneous measurements<br />

� Secure data acquisition and data<br />

handling


Petfoods – its important our<br />

best friends eat well!<br />

Horticulture –<br />

seeds – preven -<br />

tion of germination<br />

during storage<br />

Pharmaceutical<br />

industry; tablet and<br />

powder ERH<br />

Building materials<br />

Water Activity Applications<br />

Tobacco industry<br />

Bakery products<br />

Food industry – cheese<br />

Food<br />

industry –<br />

meat products<br />

Paper manufactur ing,<br />

converting, storing<br />

and printing<br />

W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

77


W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

78<br />

Introducing Water Activity Products<br />

The ROTRONIC range of water activity instruments uses the latest digital technology to introduce new levels<br />

of measurement performance, application fl exibility and new features. Multiple probe inputs, PC based data<br />

handling, instrument networking, software based calibration, and interchangeable measurement stations<br />

are just some of the features included in our latest range.<br />

The humidity sensors used in our measurement probes have an enviable reputation for precision and reliability.<br />

Their performance is now augmented by software based analysis modes and new developments in<br />

mechanical probe design. These combine to achieve consistently high levels of performance with signifi -<br />

cantly reduced sampling times, and extremely cost effective pricing.<br />

Our range of water activity measurement stations and probes feature the HygroClip digital signal processing<br />

technology, including signal transmission and calibration. This produces a signifi cant gain in accuracy,<br />

data integrity and stability, as well as convenient features such as simplifi ed PC based confi guration, data<br />

acquisition and calibration using easy-to-use Windows software.<br />

Bench top display instrumentation is also now complemented by a handheld portable solution; using the<br />

same high precision measurement technology to ensure consistently precise results and full interchangeability<br />

between laboratory and production data.<br />

HygroLab<br />

HygroLab is a range of three high quality benchtop display instruments<br />

for the laboratory environment. HygroLab 1 is a cost effective<br />

2 channel instrument with measurements displayed in %rh and °C<br />

units. HygroLab 2 has 4 probe inputs plus the option to display measurements<br />

in aw units, and an RS232 interface for display, data acquisition<br />

or confi guration.<br />

HygroLab 3 is the fl agship of our range, with all the features of the<br />

HygroLab 2, plus the addition of HygroData Quick which has specialised<br />

features specifi c to water activity analysis including rapid equilibrium<br />

in typically 5 minutes or less, plus automatic capture of fi nal<br />

values.<br />

HygroPalm AW1<br />

In some instances, the ability to measure water activity in production<br />

or storage environments can be very useful. For example, when bulk<br />

deliveries are received, they can be checked on receipt to make sure<br />

that supply specifi cations are met.<br />

The new HygroPalm AW has been specially confi gured to offer the key<br />

functions of the HygroLab 3, including HygroData Quick in a portable<br />

package<br />

Aw Quick<br />

Aw Quick is advanced software for water activity analysis which is<br />

either integrated within the HygroLab 3 or HygroPalm AW display instruments,<br />

or can be run on a PC connected to a HygroLab.<br />

Aw Quick provides the user with fi nal measurement results in typically<br />

fi ve minutes or less, or can run a conventional water activity analysis<br />

with automatic detection and capture of equilibrium values.


LC Display:<br />

Includes probe input indicator,<br />

three line numeric display<br />

MENU:<br />

Press this key to activate<br />

the functions menu<br />

Up to 32 HygroLab 2 + 3<br />

instruments can be<br />

networked together.<br />

128 measurement probes<br />

controlled by one PC!<br />

HygroLab Feature Overview<br />

UP/DOWN:<br />

Changes displayed probe and<br />

navigates.<br />

Multiple inputs:<br />

4 probes simultaneously<br />

ENTER:<br />

Confi rms selection<br />

ON / Off<br />

W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

79


W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

80<br />

HygroLab<br />

HygroLab 1:<br />

Basic two-probe bench top indicator of %rh & °C.<br />

Key features:<br />

• Accepts 2 ROTRONIC digital or analogue probes<br />

• Display of %relative humidity and temperature<br />

• Software-based probe calibration (1-point or multi-point)<br />

Order code:<br />

HygroLab 1<br />

HygroLab 2:<br />

Bench-top display instrument with four probe inputs, display in<br />

Aw units, %hr and °C.<br />

Key features:<br />

• Accepts 4 ROTRONIC digital or analogue probes<br />

• Full psychrometric calculations<br />

• Software-based probe calibration (1-point or multi-point)<br />

• Can use one of the four probes as a reference to perform a<br />

1-point adjustment of the other probes<br />

• RS232 interface for PC running HW3 software<br />

• RS485 interface for networking instruments together<br />

• Optional analogue outputs<br />

• Optional: Accelerated water activity measurement with up to<br />

4 probes: (AwQuick mode): allows the measurement of most<br />

products in typically 5 minutes; requires HW3 software<br />

Order code:<br />

HygroLab 2<br />

HygroDATA Lab Software HW3 and RS cable<br />

HygroData Quick: HygroQuick function<br />

HygroLab 3<br />

Water activity analyser with four probe inputs and integrated AW<br />

Quick.<br />

Key features:<br />

• Accelerated water activity measurement with up to 4 probes:<br />

(AwQuick mode): allows the measurement of most products in typically<br />

5 minutes<br />

• Full equilibration measurement with up to 4 probes (Standard<br />

mode) with automatic detection of equilibrium conditions<br />

• Accepts 4 ROTRONIC digital or analogue probes<br />

• Full psychrometric calculations<br />

• Software-based probe calibration (single-point or multi-point)<br />

• Can use one of the four probes as a reference to make a 1-point adjustment<br />

of the other probes<br />

• RS232 interface for PC running HW3 software<br />

• RS485 interface for networking instruments together<br />

Order code:<br />

HygroLab 3<br />

HW3 Software<br />

The HW3 software package has a comprehensive range of functions<br />

which are compatible with the HygroLab.<br />

Order code:<br />

HygroDATA Lab Software HW3 and RS cable<br />

See chapter HW3 Software for full information.


HygroPalm AW1<br />

The HygroPalm AW1 is a portable instrument specifi cally confi gured<br />

for the measurement of water activity. It includes many of the advanced<br />

features of the HygroLab, including the Aw Quick mode for<br />

results in 4–6minutes. This makes it perfectly suited for users who<br />

wish to perform water activity analysis in production, goods receiving<br />

or storage areas where portable instrumentation is more convenient.<br />

Key features:<br />

• Accelerated water activity measurement:<br />

(AwQuick mode): allows the measurement of most products in typically<br />

5 minutes<br />

• Full equilibration measurement (Standard mode) with automatic<br />

detection of equilibrium conditions<br />

• Single digital probe input<br />

• Single or multiple point digital calibration directly with the keypad<br />

• Aw display units<br />

• Available as a set with carry case<br />

• Optional docking station for battery charging or mains operation<br />

Order code:<br />

HygroPalm AW1<br />

PD1 Docking Station for AW1 with connector<br />

for AC1207 power adaptor<br />

AC1207 Power adaptor<br />

HygroPalm AW Sets<br />

For on-site measurements, or for the fi rst time user, the HygroPalm<br />

Aw sets are a perfect solution. The sets are supplied in a lightweight<br />

but tough ABS carry case, and include all the items required to perform<br />

measurements and maintain the instrument.<br />

HygroPalm AW<br />

The difference between the two sets is the size of the sample holder<br />

and sample containers. AW1-Set/14 includes the WP14/PS14 for sample<br />

sizes such as tablets, powders, seeds, powdered spices, tea etc.<br />

AW1-Set/40 includes the WP40/PS40 for larger samples such as petfood,<br />

ore, nuts, beans, etc. (see also “Accessories & Consumables” for<br />

more information)<br />

HygroPalm HygroPalm<br />

AW1-Set/14 AW1-Set/40 Description<br />

HygroPalm AW1 HygroPalm AW1 Handheld display instrument<br />

AW-DIO AW-DIO Measurement probe<br />

WP-14-S WP-40 Sample holder<br />

PS-14 PS-40 13/6 sample container<br />

EA35-SCS EA35-SCS 35 %rh calibration standards<br />

EA80-SCS EA80-SCS 80 %rh calibration standards<br />

EA50-SCS EA50-SCS 50 %rh calibration standards<br />

EA10-SCS EA10-SCS 10 %rh calibration standards<br />

AC1119 AC1119 Case<br />

W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

81


W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

82<br />

Water Activity Probes<br />

Based on HygroClip digital electronics technology for high perfor mance and convenient digital calibration,<br />

our selection of probes will suit almost any application. All water activity stations and probes incorporate<br />

temperature measurement as standard.<br />

AW-DIO Water Activity Station<br />

The AW-DIO is a water activity measurement station which measures<br />

over the range 0…1 aw (0…100 %rh) and provides a digital output<br />

signal to interface with HygroLab and HygroPalm Aw display units.<br />

Digital calibration can be performed using the display instrument.<br />

Minimised internal volume of the sensor chamber ensures fast equilibrium<br />

with all products, and an all metal construction ensures good<br />

temperature stability during measurements, with stainless steel used<br />

on all critical surfaces. Sample holders, sample containers and a sealing<br />

mechanism are detailed in accessories.<br />

AW-DIO is now the single option for water activity measurements in<br />

a sample chamber. It replaces previous products such as the WA-14,<br />

WA40, AS-ST, and WAO. It also has superseded the AWVC model<br />

with integrated air circulation fan. Through our continuous research<br />

and development program we have been able to match or better the<br />

equilibrium performance of the ventilated system with our new Aw<br />

specifi c sensor, and improved mechanical design.<br />

Measuring range: 0...100 %rh (0...1 aw), 5...50°C<br />

Order code:<br />

AW-DIO<br />

Dimensions of AW-DIO probe<br />

Temperature Control<br />

Stable temperature during measurements can be very important with<br />

some products in order to obtain precise results. Our measurement<br />

probes are designed with a high thermal mass to prevent variations<br />

during measurement, but for the highest precision or where laboratory<br />

temperature changes, temperature control solutions are avail able.<br />

Please contact ROTRONIC or your local distributor for more information.


HygroClip SP05 Insertion Probe<br />

For direct measurement of water activity in bulk samples. Applications<br />

include tablets, gel capsules, grain and plastic granules. HygroClip<br />

SP05 features a precisely engineered 5 mm-diameter stainless steel<br />

probe with laser cut slots to allow the humidity measurement sensor<br />

exposure to water vapour in the air (not suitable for powders or dusty<br />

products).<br />

Measuring range: 0...100 %rh (0...1aw), -40...85°C<br />

Order code:<br />

HygroClip SP05 5 mm insertion probe<br />

MOK-02-B5 Cable, HygroClip SP05 to<br />

HygroLab/HygroPalm Aw1<br />

Ø: 5 mm Probe length: 200 mm Cable: 2 m<br />

HygroClip HP28 Insertion Probe<br />

For direct measurement of water activity in bulk samples.<br />

Applications include powders, granules, grain and cereals. HygroClip<br />

HP28 features a robust 10 mm-diameter stainless steel probe with replaceable<br />

sintered steel dust fi lter to allow the humidity measurement<br />

sensor exposure to water vapour in the air or product.<br />

Measuring range: 0...100 %rh (0...1aw), -40...85°C<br />

Order code:<br />

HygroClip HP28 10 mm insertion probe<br />

MOK-02-B5 Cable, HygroClip SP05 to<br />

HygroLab/HygroPalm Aw1<br />

Ø: 10 mm Probe length: 280 mm Cable: 2 m<br />

HygroClip SC04 /SC05<br />

Suitable for air measurement in small spaces thanks to the 5 mm probe<br />

diameter and compact dimensions. For customers measuring water<br />

activity, the HygroClip SC05 is useful for the measurement of humidity<br />

and temperature in packaging, storage containers and incubators.<br />

Measuring range: 0...100 %rh (0...1aw), -40...85°C<br />

Order code:<br />

HygroClip SC04 4 mm cable mounted probe<br />

HygroClip SC05 5 mm cable mounted probe<br />

MOK-02-B5 Cable, HygroClip SP05 to<br />

HygroLab/HygroPalm Aw1<br />

Ø: 5 mm Cable: 2 m<br />

Water Activity Probes<br />

W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

83


W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

84<br />

Accessories and Consumables<br />

Sample Holders<br />

Stainless steel sample holders that are precisely engineered to work<br />

with the AWC/VC water activity chamber. Two sizes are available,<br />

WP14-S is for small product samples (14mm depth) and WP40 for<br />

larger materials (40mm depth). Both products provide excellent sample<br />

containment and optimum temperature stability. WP-40TH has an<br />

integrated water jacket for temperature control. Recommended temperature<br />

control level max. ±5°C from ambient temperature.<br />

Order code:<br />

WP-14-S for PS14<br />

WP-40 for PS14 and PS40<br />

WP-40TH with water jacket for temperature control<br />

Sample Containers<br />

Disposable sample containers that ensure the optimum sample volume<br />

is introduced into the WP-14-S and WP-40. They help to prevent<br />

the sample holders from coming into direct contact with product being<br />

tested, and hence prevent soiling or cross contamination. The<br />

sample containers also provide a convenient means of collecting and<br />

storing samples.<br />

Order code:<br />

PS14 Pack 100 sample containers to suit WP-14-S<br />

PS40 Pack 100 sample containers to suit WP-40<br />

Clamp Sealing Mechanism<br />

In some circumstances additional mechanical sealing of the AW measurement<br />

station and sample holder is required to prevent external<br />

conditions infl uencing the sample. The AW-KHS provides a strong<br />

mechanical seal, and is compatible with all available sample holders.<br />

(Only in combination with WP-40 and WP-40TH)<br />

Order code:<br />

AW-KHS<br />

Humidity Standards<br />

The ROTRONIC SCS certifi ed humidity standards provide a reference<br />

value against which instruments can be calibrated. They are supplied<br />

in packs of 5, complete with certifi cates of calibration. They can be applied<br />

to all probe types, with Water Activity probes using sample holders<br />

and containers, for other probes (HygroClip SP05, SC04 and HP28)<br />

a calibration device is required.<br />

Order code:<br />

EA-xx-SCS Where xx = 00, 05, 10, 11, 20, 35, 50, 65, 75,80 & 95%rh<br />

Calibration Devices<br />

Provide a sealed environment around probes where ROTRONIC humidity<br />

standards can be applied.<br />

Order code:<br />

ER-05 for 5 mm diameter probes (HygroClip-SP05 / SC05)<br />

ER-15 for 15 mm diameter probes (HygroClip S)<br />

EGL for 10 mm diameter probes (HygroClip HP28)<br />

Aw-DIO can be calibrated in combination with the sample holder and<br />

container (WP-14/PS14).


What is Water Activity?<br />

Water Activity Explained<br />

Water Activity (aw) is the relative humidity which is reached at equilibrium in a sealed container in which<br />

a hygroscopic product has been placed, but expressed on a scale of 0…1. Water Activity measurement is<br />

most commonly used in the food industry, where it is used to determine shelf life and quality.<br />

What is Equilibrium Relative Humidity?<br />

Equilibrium Relative Humidity (ERH) is the value of relative humidity into which a Hygroscopic product can<br />

be placed where no net exchange of moisture between the product and the surrounding environment can<br />

take place. It is expressed on a scale of 0…100%. ERH is typically used in the paper and pharmaceutical<br />

industries, but can be applied to almost any product that is sensitive to moisture, or where the presence of<br />

moisture can effect product handling.<br />

Aw or ERH?<br />

Both aw and ERH are an expression of the amount of free water vapour present on a product, both at its<br />

surface and within its structure, and are practically the same measurement expressed in a slightly different<br />

way. Throughout this data sheet we will refer to Water Activity, but this can be interchanged with ERH.<br />

Where specifi ed, ROTRONIC products offer the user the possibility to select display units of aw or %rh.<br />

What is Moisture Content?<br />

Moisture content, when referring to a solid material, is an expression of the percentage of the materials<br />

weight which is water (both in liquid or gaseous phase); usually referred to as ‘percent moisture content’.<br />

This term is widely used in many areas of industry.<br />

Water Activity or Moisture Content?<br />

There is frequently confusion between Water Activity and moisture content measurements. In many industries,<br />

moisture content is used to control the amount of water present in a product for quantitative reasons.<br />

For example, if a product is sold by weight, controlling its moisture content may be useful in maintaining<br />

product quality, but can also impact on profi tability (more water equals more profi t).<br />

Water activity is more signifi cant for qualitative considerations such as product stability shelf life (e.g.<br />

microbiological & enzymatic stability, aroma retention), handling characteristics (e.g. agglomeration of<br />

powders), physical properties (e.g. dimensions of paper) and chemical stability (e.g. pharmaceuticals).<br />

Sorption Isotherm<br />

Water Activity and Moisture Content can be related by a graph<br />

called a Sorption Isotherm (see diagram) so if the user has the ability<br />

to measure both parameters, the relationship can be defi ned<br />

and each parameter derived from the other (interpolation).<br />

In practice, the Sorption Isotherm may be impractical to use, because,<br />

not only does the relationship between aw and moisture<br />

content change with temperature of measurement, but also any<br />

variation in the material composition has a modifying effect. This<br />

is especially the case with products of natural origin such as food<br />

and paper. The user should therefore decide which parameter of<br />

measurement is best suited to their product and processes. For<br />

quality control purposes moisture content limits are easily converted<br />

to Water Activity limits by very simple comparative tests.<br />

Water Activity offers a non-destructive, easy to use measurement<br />

in a wide range of convenient confi gurations for both laboratory<br />

and on-site use.<br />

W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

85


W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

86<br />

Adr. 0 Adr. 1 Adr. 2 Adr. 31<br />

WP-14-S WP-40<br />

WP-40TH<br />

Schematics and Diagrams<br />

Networking (HygroLab 2 and 3)<br />

The optional HW3 software offers a simple means of quickly establishing a PC based network. Up to 32<br />

HygroLab indicators and/or HygroFlex transmitters can be connected together on a network. Any instrument<br />

can be used either as a slave or a master, without special confi guration. Each unit must be given a<br />

unique network address with the HW3 software (0 to 31). The master is automatically the unit that is connected<br />

to the COM port of the PC by means of the RS232 port. See Connectors – RS232 / RS485 for details.<br />

RS232 (3 wires)<br />

max. 12 m<br />

Dimensional diagrams<br />

RS485 (2 wires)<br />

max. 1000 m<br />

~160<br />

AW-KHS<br />

~220<br />

200 x 120


Technical Data<br />

Key Features HygroLab 1 HygroLab 2 HygroLab 3 HygroPalm Aw 1<br />

Probe Connections 2 4 4 1<br />

PC Interface No RS232/485 RS232/485 No<br />

Networking No Up to 32 instruments using RS485 No<br />

Aw Quick mode No With HygroData Integrated & with Integrated<br />

Quick (Software HygroData-LAB<br />

and PC) (HW3 Software<br />

and conn. cable)<br />

Calibration functions 1 point Using keypad Using keypad Using keypad<br />

with keypad or PC; 1 or or PC; 1 or 1 point %rh (aw), °C/F,<br />

4 point %rh (aw), 4 point %rh (aw), 4 point %rh,<br />

2 point °C/h 2 point °C/F 2 point °C/F<br />

Display units %rh, °C, °F, %rh, aw, °C, °F, calculated parameters aw, °C, °F,<br />

Calculated parameters None Dew-point, wet-bulb, None<br />

enthalpy, mixing ratio,<br />

moisture content,<br />

partial water vapour pressure,<br />

saturation water vapour pressure<br />

Audible signal<br />

upon measurement end: No No Yes No<br />

Accuracy at 23°C ±1.5 %rh, ±0.3 K ±1.5 %rh, ±0.015 aw, ±0.3 K<br />

Repeatability Better than 0.5 %rh Better than 0.5 %rh/0.005 aw, 0.1°C/0.2°F<br />

0.1°C/0.2°F<br />

Sensors Probe dependent<br />

Instrument<br />

operating range 0…99 %rh, -10…60°C (14…140°F)<br />

Display Type Liquid Crystal 3 line alphanumeric<br />

Trend indicator No Yes Yes Yes<br />

Display resolution 0.1 %rh/0.1°C/F 0.1 %rh, 0.001 aw, 0.1°C/F, 0.01 calculated value<br />

Housing Aluminium, 220 x 170 x 55 mm ABS<br />

Power 9 V Power adapter, +tip PP3 battery, or 9 V<br />

power adapter +tip<br />

through PalmDock<br />

CE Conformity EMV: EN50081-2 EN/EN50082-2<br />

Note:<br />

Many older products have been replaced by new ones, that perform better.<br />

ROTRONIC will continue to support the old products as long as possible.<br />

Our customers are used to the fact, that we still maintain probes and instruments that are over 20 years old.<br />

We will continue this tradition for the benefi t of our customers who will thus always get the best price / performance<br />

ratio and have their investments secured.<br />

W<br />

A<br />

T<br />

E<br />

R<br />

A<br />

C<br />

T<br />

I<br />

V<br />

I<br />

T<br />

Y<br />

87


T<br />

E<br />

M<br />

P<br />

E<br />

R<br />

A<br />

T<br />

U<br />

R<br />

E<br />

88<br />

Temperature Measuring <strong>Instruments</strong><br />

Temperature Measuring <strong>Instruments</strong> T1, T51, T55<br />

The measurement of temperature is essential in many production processes, storage, drying and transportation<br />

applications, and even at home for a comfortable climate. In many countries, the law demands that<br />

in the food- and pharmaceutical industry temperature is controlled and recorded. ROTRONIC offers handheld<br />

instruments and transmitters for this purpose, which are used in the pharmaceutical industry, as well<br />

as in dairy food chains, the transportation sector, warehouses etc. The easy handling and installation, and<br />

the wide measuring ranges make them suitable for most applications. The M-series and Roline-L-series<br />

transmitters are also available for temperature measurement only.<br />

Handheld measuring instrument T1 for Pt100 probes<br />

• Measuring range: -100…500°C<br />

• Plug in Pt100 probes, see next page<br />

• Automatic range adjustment at 200°C<br />

• Large, 3 1 /2 digit LCD display<br />

• DATA HOLD<br />

• °C/°F selectable on PCB by jumper<br />

• Adjustable<br />

Order code:<br />

T1<br />

Handheld measuring instrument T51<br />

• Interchangeable thermocouple type K, see page 90<br />

• Max. display<br />

• DATA HOLD<br />

• Impact protection<br />

• Includes one wire probe<br />

• °C/°F switch selectable<br />

Order code:<br />

T51<br />

Handheld measuring instrument T55<br />

• 2 interchangeable thermocouples type K or J, see page 90<br />

• Min/max display<br />

• DATA HOLD<br />

• Temperature difference T1-T2<br />

• Stopwatch function<br />

• Impact protection<br />

• Includes two wire probes<br />

• °C/°F switch selectable<br />

Order code:<br />

T55<br />

TI Transmitter for Pt100 probes<br />

• Transmitter for the most demanding industrial processes<br />

• IP65 housing<br />

• Linear output signals<br />

• Probe connector on housing<br />

• Connectable Pt100 probes, see next page<br />

• Optional digital display<br />

Order code:<br />

see table on page 91


Temperature Measuring Probes Pt100 Probes<br />

Order code Probe type Specifi cation Material Cable All Probes with Binder 4 pin plugs<br />

AC 1900 Rod Type, -70...300°C DIN 1.4401 N/A<br />

100 x 3 mm Pt 100 Class A<br />

AC 1901 Rod Type -70...500°C DIN 1.4401 N/A<br />

250 x 3 mm Pt 100 Class A<br />

AC 1902 Penetration Type -70...500°C DIN 1.4401 1m<br />

250 x 3 mm Pt 100 Class A PUR<br />

Tmax Cable: spiral<br />

80°C<br />

AC 1903 Cable Type -70...500°C DIN 1.4401 2m<br />

200 x 6 mm Pt 100 Class A Silicon<br />

Tmax Cable: straight<br />

180 °C<br />

AC 1904 Cable Type -50...120°C DIN 1.4401 2m,<br />

50 x 6 mm Pt 100 Class A Thermoplast<br />

Tmax Cable: straight<br />

120°C<br />

AC 1905 Surface Type -70...300°C Brass 2m<br />

40 x 10 x 5 mm Pt 100 Class A Silicon<br />

Tmax Cable: straight<br />

180°C<br />

AC 1907 Surface Type, 0...200°C DIN 1.4401 1m<br />

angle 90 °, Pt 100 Class B PUR<br />

250/60 x 5 mm Tmax Cable: spiral<br />

80°C<br />

AC 1908 Handheld, for -50...200°C DIN 1.4401 1m<br />

measurement in air Pt 100 Class A spiral<br />

250 x 5 mm Tmax Cable:<br />

80°C<br />

AC 1909 Rod, for -50...200°C DIN 1.4401 2m<br />

measurement in air Pt 100 Class A Silicon<br />

100 x 5 mm Tmax Cable: straight<br />

180°C<br />

AC1910 Screw in, -70...500°C DIN 1.4401 N/A<br />

1⁄4" G, 30 mm Pt 100 Class A<br />

Tmax Cable:<br />

180°C<br />

AC 1911 Screw in, -70...500°C DIN 1.4401 N/A<br />

1⁄4" G, 50 mm Pt 100 vA<br />

Tmax Cable:<br />

180°C<br />

AC 1912 Screw in, -70...500°C DIN 1.4401 N/A<br />

1⁄4" G, 100 mm Pt 100 Class A<br />

Tmax Cable:<br />

180°C<br />

AC 1913 Foil 0...200°C Silicon 1m<br />

25 x 32 x 1 mm Pt 100 Class A<br />

Pt100 Probes<br />

30<br />

ø4.5<br />

100<br />

40<br />

1/4"G<br />

10<br />

200x5<br />

ø5<br />

30 50 L<br />

1/4"G<br />

ø5<br />

30 50 L<br />

1/4"G<br />

ø5<br />

30 50 L<br />

25<br />

32<br />

5<br />

1<br />

60x5<br />

T<br />

E<br />

M<br />

P<br />

E<br />

R<br />

A<br />

T<br />

U<br />

R<br />

E<br />

89


T<br />

E<br />

M<br />

P<br />

E<br />

R<br />

A<br />

T<br />

U<br />

R<br />

E<br />

90<br />

Temperature Measuring <strong>Instruments</strong><br />

Order Code Probe Type Specifi cation Useed for All Probes<br />

with K-type plug<br />

44.10.1885 TCP-A -50...800°C Measuring in the<br />

Penetration probe K-element, food industries in<br />

150 x 4 mm semi-compact material<br />

such as jelly etc.<br />

44.10.1890 TCP-B -50...800°C Measuring in liquids<br />

Immersion probe K-element and jellies etc.<br />

200 x 2 mm<br />

44.10.1486 RO40017 -50...480°C Multi purpose probe<br />

Universal probe K-element,<br />

28 x 57 mm<br />

44.10.1900 TCP-F -50...800°C Fast measuring<br />

Surface probe K-element on surfaces<br />

150 x 10 mm<br />

44.10.1475 S533 -50...250°C For measuring in air,<br />

wire probe K-element liquids etc.<br />

1000 x 1.3 mm<br />

Accessories<br />

AC 2001 Screw-in measuring-sleeve for 3 mm<br />

probes; Thread 1⁄4" G<br />

Immersion depth 50 mm<br />

AC 2002 Screw-in measuring-sleeve for 3 mm<br />

probes; Thread 1⁄4" G<br />

Immersion depth 100 mm<br />

HygroClip TH100-B5 Adaptor for all Pt100 probes<br />

for HygroPalm 2/3 & HygroLab instruments<br />

with Binder 5-pin plug


Order Code TI Temperature Transmitters<br />

Temperature Transmitters<br />

Order code 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />

Example: TI1 - 2 - B 4 - 4 A 1 X - 1 4<br />

Transmitter Series TI1 -<br />

Power supply: 230 VAC 0<br />

115 VAC 1<br />

4…20mA loop power (Umin =10 V+0.02 x load) 2<br />

24 VAC galvanically separated 3<br />

10(15)…35 VDC/12…24 VAC 8<br />

PT100 connector Binder 4-pin B 4<br />

Output signal 0…20 mA 0 A<br />

4…20 mA 4 A<br />

0…1 V 1 V<br />

0…5 V 5 V<br />

0…10 V 0 V<br />

Cable connection 1 M16 Terminals 1<br />

2 M12 Terminals 2<br />

Tuchel plug 7-pin 7<br />

Display None X<br />

With Display D<br />

Temperature Range = 0…50°C 1 0<br />

Output signal -30…70°C 1 1<br />

0…100°C 1 4<br />

-40…60°C 1 9<br />

0…200°C 2 0<br />

-50…150°C 2 1<br />

-100…100°C 2 2<br />

-100…200°C 2 3<br />

-100…300°C 2 4<br />

Technical Data Temperature Measuring <strong>Instruments</strong><br />

Series T1 T51 T55 TI-Series<br />

Instrument type Handheld Transmitter<br />

IP Protection rating IP50 IP-50, rubber impact protection IP65<br />

Power supply AC/DC/mains<br />

9 V PP3 alkaline battery Yes No<br />

10…35 VDC/24 VAC N/A Option<br />

115 /230 V AC N/A Option<br />

Galvanic separation N/A Option<br />

4…20 mA loop power<br />

(Umin =10 V+0.02 x load) N/A Option<br />

Number of Probe inputs 1 1 2 1<br />

Connection type of probe 3-wire 2-wire 3-wire<br />

Operating range electronics 0…50°C / 0…90%rh -20…50°C<br />

Measuring range withPt100 -100…500°C N/A N/A<br />

with K-Type N/A -50…1300°C -200…1370 °C Probe dependent<br />

with J-Type N/A N/A -200…760 °C<br />

Accuracy at 23°C Pt100 ±0.1 K ±0.3 K<br />

1000°C N/A ±0.5% +1 K ±0.3% +1 K N/A<br />

Reproducibility 0.1 K<br />

Display 31⁄2 Digits 4 Digits Option, not for<br />

loop power<br />

Auto Power Off Yes No N/A<br />

Low Battery Indicator Yes N/A<br />

Hold Function Yes N/A<br />

Tmax. recording No Yes N/A<br />

Differential Temp. No Yes N/A<br />

Stop Watch No Yes N/A<br />

T<br />

E<br />

M<br />

P<br />

E<br />

R<br />

A<br />

T<br />

U<br />

R<br />

E<br />

91


O<br />

E<br />

M<br />

P<br />

R<br />

O<br />

D<br />

U<br />

C<br />

T<br />

S<br />

92<br />

OEM<br />

Original Equipment Manufacturers (OEM’s) require individual solutions to suit the needs of their customers.<br />

ROTRONIC have been producing customised humidity measurement products to suit the OEM for<br />

many years, and have a wide breadth of experience in satisfying this specialist need.<br />

Today, our OEM capability is greater than ever, from the simplest sensor<br />

supply, right through to complex transmitters for the industrial<br />

process market. One thing is clear, the demands of the customer and<br />

the end use are rarely the same, so the need for a professional and<br />

fl exible supplier is key.<br />

As each project is different, our experienced sales team will discuss<br />

project objectives, technical requirements and target costs at a preliminary<br />

meeting. We will then formulate an initial proposal based on<br />

this discussion and submit this to the customer.<br />

After agreeing a fi nal specifi cation, samples can then be submitted for<br />

technical approval and testing. During this phase, ROTRONIC are able<br />

to participate in the customer assessment of product suitability, and if<br />

required, provide secondary testing of the completed assembly in our<br />

own accredited test facilities. We are also able to advise on the fi nal<br />

assembly and calibration process.<br />

Wherever possible, we will utilise existing products or sub assemblies<br />

in the creation of an OEM solution. This can provide signifi cant advantages<br />

in design and development costs, as well as reducing the start<br />

up times.<br />

ROTRONIC OEM Product Capability<br />

• %rh sensors<br />

• Calibrated sensor modules<br />

• Transmitter or probe sub assemblies<br />

• Standard ROTRONIC products with customers own branding<br />

ROTRONIC OEM Support Capability<br />

• Custom design<br />

• Custom packaging<br />

• Labelling and barcodes<br />

• Documentation, including manuals<br />

• CAD drawings for manufacturing records<br />

• Calibration materials and systems<br />

• Training of customers technical and sales staff


%rh Sensors<br />

OEM<br />

In many high volume applications, the supply of only the %rh sensor<br />

is a cost effective option. In these circumstances the OEM should carefully<br />

consider the process of calibrating the fi nal measurement circuit<br />

to obtain the required performance. When calculating the actual cost<br />

of the implementation of humidity measurement, the sensor cost<br />

must include provision of the calibration process, circuit design and<br />

fi nal assembly. In many cases, the specifi cation of a pre-calibrated<br />

measurement module can be equally cost effective, and can reduce<br />

the ongoing costs of production.<br />

ROTRONIC can supply a range of %rh sensors based on capacitive or<br />

resistive technologies. Various standard products are available with<br />

pre-defi ned specifi cations, dimensions and characteristics. We are<br />

also able to offer customised sensor production to suit specifi c project<br />

requirements.<br />

Calibrated %rh Sensor modules<br />

The advantage of implementing a pre-calibrated sensor module is that<br />

the OEM does not have to develop a measurement circuit or an inhouse<br />

calibration system.<br />

The appropriate product can be specifi ed to be compatible with existing<br />

interface and power supply requirements, and with simple connection<br />

to the fi nal application prior to delivery. The whole specifi cation,<br />

design and supply of the humidity measurement element of the OEM<br />

need can be handled by ROTRONIC, leaving the customer to focus on<br />

their core product development and support.<br />

ROTRONIC in house calibration procedures have been developed over<br />

many years, and proven in many thousands of instances. The end result<br />

for the OEM customer is a well developed production process that<br />

assures best possible measurement performance with zero investment.<br />

%rh Transmitter or Probe Sub Assemblies<br />

For OEM customers who offer their own branded range of %rh sensors,<br />

for end uses such as HVAC/BMS, process control or data-acquisition,<br />

ROTRONIC can supply a completed and calibrated product to fi t<br />

the customers own housings.<br />

In these circumstances, the customer has two main advantages. The<br />

responsibility for product design, assembly and calibration is handled<br />

by ROTRONIC, which minimises production costs and component<br />

stock risk. The customer also benefi ts from an ‘own brand’ product<br />

which has the very best performance capability, and has access to<br />

ongoing development to keep the product at the leading edge of the<br />

humidity market.<br />

Standard products with customers own branding<br />

Throughout the pages of this catalogue you will fi nd a range of humidity<br />

measurement products that are market leading in terms of performance,<br />

features and price. ROTRONIC are happy to effect a simple<br />

‘re-brand’ of the standard product range so that the OEM can offer a<br />

class leading product with no development cost and minimal stock<br />

risk.<br />

Ancillary products such as calibration materials, replacement fi lter<br />

elements and software are of course already available. Support documentation<br />

such as manuals, software validation, type approvals and<br />

drawings can be easily re-branded on behalf of the OEM customer.<br />

O<br />

E<br />

M<br />

P<br />

R<br />

O<br />

D<br />

U<br />

C<br />

T<br />

S<br />

93


O<br />

E<br />

M<br />

P<br />

R<br />

O<br />

D<br />

U<br />

C<br />

T<br />

S<br />

94<br />

Example OEM Products<br />

The products described are standard OEM products which are mass produced for many existing cus tomers.<br />

They are available on very short delivery times, often from stock, and require no further development<br />

or documentation. Full technical datasheets are available in standard formats and show full technical<br />

and mechanical specifi cations. The range of products shown is by no means defi nitive, we could fi ll the<br />

whole of this catalogue with the OEM products in current production at ROTRONIC, so please contact us<br />

if the product you need is not shown.<br />

Technical Data:<br />

CS %rh sensor<br />

The CS %rh sensor is a substrate based capacitive %rh sensor. It is<br />

designed specifi cally for applications where high quality is as important<br />

as cost. Three standard versions are available to suit most applications.<br />

Features overview:<br />

• Wide range of operating temperatures<br />

• Chemically resistant<br />

• Long term stable<br />

• Fast response times<br />

• Low hysteresis<br />

• Heated version for high humidity applications (CS70)<br />

• Compact dimension and high sensitivity(CS10)<br />

• Fast response & solvent resistant (CS30)<br />

CS10 CS30 CS70<br />

Humidity measuring range 0...100 %rh 0...100 %rh 0...100 %rh<br />

Temperature operating range -30...150°C -40...190°C -10...50°C<br />

Typical capacitance at 30 %rh and 23°C 140 pF ±40 pF 300 pF ±40 pF 250 pF ±50 pF<br />

Typical sensitivity (15 ... 95 %rh) 0.4 pF / %rh 0.45 pF / %rh 0.45 pF / %rh<br />

Linearity at 23°C ± 1.5 %rh ±2.0 %rh ±2.0%rh<br />

(20...90%rh) (20...95 %rh (20…95 %rh)<br />

Hysteresis < 1.5 %rh < 2.0 %rh < 2.0 %rh<br />

Response Time t90


HygroClip<br />

Example OEM Products<br />

The HygroClip-S is a standard humidity and temperature sensor module<br />

which is widely used throughout the ROTRONIC product range<br />

on end-user products such as handheld instruments, data loggers and<br />

transmitters. It is already in widespread use by third party OEM instrument<br />

manufacturers thanks to its excellent performance and price.<br />

HygroClip is available as standard in a wide range of confi gurations<br />

to suit almost any end use, and in addition, can be customised to<br />

suit speci fi c OEM needs. Variations in mechanical packaging, colour,<br />

connectors and cable lengths can all be incorporated into a unique<br />

design.<br />

Further information and full technical specifi cations can be found<br />

on page 62 to 67.<br />

Transmitter sub assembly<br />

H290 is an OEM humidity and temperature product with an impressive<br />

specifi cation. It is particularly well suited to applications such as climatic<br />

chambers and drying systems. It is available either as a pcb and<br />

probe combination for fi tting into the customers own enclosures or<br />

housings, and can also be supplied in an industry standard IP65 case.<br />

H290 provides a liners analogue output of 4…20 mA or 0…10 V from<br />

a power supply of 10…35 VDC or 12…24 VAC. Temperature measurement<br />

is by direct connection to a Pt100 or Thermistor, depending on<br />

the customers requirements.<br />

Also featured on the H290 is a compensation system for operation<br />

over a wide –50…200°C range, with integrated cable length compensation.<br />

This means that whatever the measurement temperature, or<br />

the differential in temperature between sensors and electronics, optimum<br />

results will be obtained.<br />

THT Series<br />

A range of humidity transmitters with excellent stability and very cost<br />

effective pricing. The THT series offers a range of analogue outputs<br />

such as 4…20mA and 0…10 Volt, for both humidity and temperature.<br />

There is also as the option to connect directly to a temperature sensor<br />

such Pt100 or Thermistor.<br />

THT is highly suitable for close control applications such as air conditioning<br />

or building monitoring where steady state conditions are<br />

usual.<br />

Roline L<br />

Our standard low cost transmitter is particularly well suited to OEM<br />

application thanks to its excellent combination of performance and<br />

price. It has a wide choice of measurement ranges and output signals,<br />

and its compact printed circuit board dimensions means that it can be<br />

easily integrated or reconfi gured into existing housings.<br />

See pages 53 to 55 for further details.<br />

For full technical specifi cations, dimensions, and specifi c product features, please request<br />

the individual datasheets.<br />

O<br />

E<br />

M<br />

P<br />

R<br />

O<br />

D<br />

U<br />

C<br />

T<br />

S<br />

95


C<br />

A<br />

L<br />

I<br />

B<br />

R<br />

A<br />

T<br />

I<br />

O<br />

N<br />

96<br />

Calibration<br />

ROTRONIC instruments have excellent long-term stability characteristics, with better than ±1%rh stability<br />

over a year in normal conditions, but we still recommend that regular calibration checks are performed<br />

(once per year typically). Normal conditions can be defi ned when high temperature or humidity, or MAC<br />

(Maximum Allowable Concentration) levels of chemical pollutants are not typical. Many company operating<br />

procedures call for calibrations more frequently, depending on internal quality assurance systems.<br />

Why is calibration essential?<br />

Today, many companies are working under to ISOO9000 standards and are therefore obliged to calibrate their<br />

measuring equipment on a regular basis. Organisations such as the FDA (The Food and Drug Administration<br />

in the USA) also demand that the devices are calibrated and traceable to national standards. Last but not<br />

least, the quality standards defi ned by each company ask for best possible accuracy and proof of traceability.<br />

Hence, it is in the interest of the user, to have equipment calibrated and adjusted in order to maintain optimum<br />

performance.<br />

We offer calibration devices and accessories for all probes manufactured by ourselves, and also for products<br />

produced by other manufacturers. Please contact us for guidance on the most appropriate calibration device<br />

and standards.<br />

Key features<br />

• Non-saturated salt solutions<br />

• Sealed glass ampoules<br />

• Ready-to-use solutions<br />

• SCS-certifi ed<br />

• Specifi c calibration devices<br />

Your benefi ts<br />

Section contains Page<br />

Humidity Standards 97<br />

� Certifi ed and traceable<br />

� Long shelf life<br />

� Precise and easy to handle<br />

� Ready for use – no solution-preparation<br />

Calibration devices 98<br />

� Easy to use<br />

� Robust<br />

� Optimised chamber volume<br />

Calibration with PC 99<br />

� HygroLab calibration<br />

� HygroFlex calibration<br />

� Simple handling, low temperature dependence<br />

� Long shelf life – 10 years guaranteed<br />

� No mistakes during preparation<br />

� Traceable to national standards<br />

� Optimum volume for each probe<br />

Rotronic and some Rotronic distributors or subsidiaries offer calibration<br />

seminars for their customers.<br />

Ask your distributor or Rotronic subsidiary for further information.


SCS* humidity standards<br />

The humidity standards from ROTRONIC are delivered in boxes of<br />

5 sealed ampoules of the same humidity value. Each ampoule is<br />

marked with the %rh value and a serial number.<br />

SCS* certifi ed humidity standards<br />

Order code: Humdity value<br />

EA00-SCS 0.5%rh<br />

EA05-SCS 5.0%rh<br />

EA10-SCS 10.0%rh<br />

EA11-SCS 11.3%rh<br />

EA20 SCS 20.0%rh<br />

EA35-SCS 35.0%rh<br />

EA50-SCS 50.0%rh<br />

EA65-SCS 65.0%rh<br />

EA75-SCS 75.3%rh<br />

EA80-SCS 80.0%rh<br />

EA95-SCS 95.0%rh<br />

Uncertainty of Rotronic<br />

SCS* Humidity Standards<br />

Humidity in %rh Measurement uncertainty at 23 ±2°C<br />

5 ± 0.1 %rh<br />

10 ± 0.3 %rh<br />

11.3 ± 0.3 %rh<br />

20 ± 0.3 %rh<br />

35 ± 0.5 %rh<br />

50 ± 0.9 %rh<br />

65 ± 0.9 %rh<br />

75.3 ± 0.9 %rh<br />

80 ± 1.2 %rh<br />

95 ± 1.2 %rh<br />

* SCS: Swiss Calibration Services<br />

Humidity standards<br />

The most frequently used values are 35 and 80%rh, which are used to<br />

perform a 2-point calibration. All ampoules contain a non-saturated<br />

salt solution, apart from the 0% standard, which uses a highly porous<br />

ceramic material (molecular sieve). An SCS certifi cate stating the<br />

traceability and uncertainty of the humidity standard is enclosed with<br />

every pack.<br />

<strong>Instruments</strong> produced by other manufacturers may require different<br />

values for adjustment. ROTRONIC offer a complete range of %rh values<br />

to suit most requirements.<br />

C<br />

A<br />

L<br />

I<br />

B<br />

R<br />

A<br />

T<br />

I<br />

O<br />

N<br />

97


C<br />

A<br />

L<br />

I<br />

B<br />

R<br />

A<br />

T<br />

I<br />

O<br />

N<br />

98<br />

EM-15/25<br />

EMV-15/25<br />

EGL/ER-15<br />

ERV-15 EGS<br />

EDM-15/25<br />

Calibration devices<br />

Calibration Devices<br />

Calibration devices<br />

Order code: Suitable for Mounting / Orientation<br />

ER-05 probes with 4/5 mm ø push-on<br />

EGL probes with 10 mm ø (A1) push-on<br />

ER-15 probes with 15 mm ø push-on<br />

ER-18K probes with 18 mm ø push-on<br />

ER-20K probes with 20 mm ø push-on<br />

ERV-15 probes with 15 mm ø push-on / vertical<br />

EM-15 probes with 15 mm ø push-on<br />

EM-25 probes with 25 mm ø push-on<br />

EMV-25 probes with 25 mm ø push-on / vertical<br />

EMV-15 probes with 15 mm ø push-on / vertical<br />

EDM 15/25 2 probes, 15 & 25 mm ø screw-in<br />

EM-G screw-in probe type E, HP...E... screw-in<br />

EGS for all ROTRONIC sword probes push-on<br />

EAS for bell probe AS-ST<br />

EAWC for AWC-measuring station<br />

EBFC for web probe BFC<br />

ERA for bell probe for rolls<br />

WP-14 for probe AWD, AWVC, AW-DIO<br />

The ROTRONIC calibration devices are small, airtight chambers, that<br />

fi t exactly to the respective probes. The lower part is a screw-mount<br />

lid, into which the humidity standard is fi lled, together with a textile<br />

pad. After a period of stabilisation, typically 60 minutes at stable temperature,<br />

the required humidity value is attained. The instrument can<br />

now be calibrated against the humidity reference value.<br />

Calibration devices are available for the entire range of Rotronic<br />

products, and we can also supply calibration devices for third party<br />

probes.<br />

The inner volume of the calibration device should not be too large; it<br />

should not exceed 50 ml of free space when the probe is fi tted. When<br />

the volume is too large, the correct humidity may eventually not be<br />

generated and the calibration reference incorrect.


Calibration of HygroClip probes<br />

with HygroLab 2 & 3<br />

Calibration<br />

The digital HygroClip probes may easily be calibrated in quantities<br />

by using the bench-top instrument HygroLab2. Up to 4 probes can be<br />

connected simultaneously to a single HygroLab 2. When the software<br />

HW3 is used, as many as 32 HygroLabs can be networked together,<br />

thus offering the possibility of calibrating or adjusting 128 probes. For<br />

customers who must calibrate many probes, this is a solution that<br />

saves a lot of time.<br />

As the instruments, probes and humidity standards can be maintained<br />

in a single room, not only the acclimatisation time can be reduced but<br />

also the accuracy will be improved.<br />

The HygroLab may be connected to any digital HygroClip probe for<br />

calibration.<br />

Calibration with a PC and HW3 software<br />

Up to 64 probes connected to a HygroFlex network of max. 32 transmitters<br />

may be calibrated by a PC, with the HW3 software.<br />

The calibration devices can be mounted on all probes on the respective<br />

transmitters, and fi nally, the calibration or adjustment<br />

be made with a few mouse clicks.<br />

The system will also print calibration reports if required.<br />

Calibration by direct PC connection<br />

Using the MOK connection cable and HW3 software<br />

Order code:<br />

MOK-02-WIN Adapter cable<br />

HW3 Universal software<br />

C<br />

A<br />

L<br />

I<br />

B<br />

R<br />

A<br />

T<br />

I<br />

O<br />

N<br />

99


H<br />

W<br />

3<br />

S<br />

O<br />

F<br />

T<br />

W<br />

A<br />

R<br />

E<br />

100<br />

HW3 Core Features<br />

HW3 Software<br />

Thanks to advances in digital technology, most of the instruments<br />

now produced by ROTRONIC feature a bi-directional RS232 interface.<br />

This works with PCs to display measured data, download recorded<br />

measurements or confi gure the system. In the past, the user often<br />

had a to use separate software for each instrument, which meant<br />

they had to learn different programs to be able to operate, and make<br />

the best use of their instrument. Today, ROTRONIC provides a single<br />

software package, HW3, which is compatible with our entire range of<br />

products, so that the user has only one system to learn for every humidity<br />

measurement application.<br />

HW3 software is developed and maintained in house at ROTRONIC<br />

by a skilled team of software developers. They are also involved in<br />

the development of our instrumentation, so are familiar with entire<br />

systems operation fi rst hand. This ensures that we are able to offer<br />

immediate support for products in the fi eld, and make sure that when<br />

new features and software routines are introduced, they are always<br />

compatible with the instrumentation hardware that we supply, or have<br />

supplied in the past.<br />

As well as our in-house developers, ROTRONIC has a second excellent<br />

source of software developers – our customers. Over many years of<br />

supplying PC compatible instrumentation, we have received many<br />

customer requests for new features or improvements. The feedback<br />

we receive is always considered when we are developing improvements<br />

to our software, so that over many years, it has evolved into<br />

one of the most comprehensively featured and user friendly packages<br />

on the market today.<br />

The range of features within HW3 is extensive, and the confi guration of the instrument connected of course<br />

infl uences what is possible, so check the specifi cation of your instrument of choice to determine compatibility<br />

with the following features:<br />

• Display of measured values directly on your PC<br />

• Alarm setting and monitoring<br />

• Audible, visual, email or SMS alarm notifi cation<br />

• Display of recorded values from data loggers<br />

• Display of an entire network of connected instruments<br />

• Data acquisition of measured values from a network of connected instruments<br />

• Archiving of measurement data<br />

• Instrument confi guration<br />

• Instrument identifi cation<br />

• Instrument status<br />

• Probe recalibration<br />

• Production of calibration certifi cates<br />

• Calculation of different psychrometric parameters such as dewpoint, wet-bulb temperature,<br />

mixing ratio, etc.<br />

• Accelerated Water Activity analysis (HygroData Quick upgrade)<br />

• …and many more…<br />

HW3 Validation<br />

Many ROTRONIC customers have learnt to depend on the accuracy and reliability of our humidity and temperature<br />

measurement systems. The advent of PC compatible products for measurement display and storage,<br />

as well as instrument confi guration and maintenance, has opened new many application possibilities.<br />

In many high value and critical applications accurate measurement is only part of the story. Data integrity<br />

and security is today an essential requirement, and in many circumstances, software must be validated for<br />

the measurement data to be accepted. HW3 is regularly submitted for software validation, and certifi cates<br />

of compliance are available to our customers. Of particular importance is the FDA regulation 21 CFR Part 11,<br />

which HW3 meets (documentation available on request).


Connect handheld instruments<br />

for confi guration,<br />

calibration, display and<br />

record measured values.<br />

Monitoring and display of water<br />

activity measurements including<br />

accelerated analysis and automatic<br />

data capture.<br />

HW3 Feature Overview<br />

Connect transmitters for<br />

confi guration, calibration,<br />

measurement display and<br />

data acquisition.<br />

Display measured values from a<br />

network of 32 HygroFlex or HygroLab<br />

instruments. Up to 128 probes simultaneously.<br />

Validated software<br />

FDA 21 CFR Part 11 compliant.<br />

Program data loggers<br />

and download data.<br />

Setting and notifi cation of<br />

alarms, audible, visual, SMS<br />

or e-mail.<br />

Control the calibration and<br />

adjustment of digital probes,<br />

including production of<br />

calibration certifi cates.<br />

H<br />

W<br />

3<br />

S<br />

O<br />

F<br />

T<br />

W<br />

A<br />

R<br />

E<br />

101


H<br />

W<br />

3<br />

S<br />

O<br />

F<br />

T<br />

W<br />

A<br />

R<br />

E<br />

102<br />

HW3 Features<br />

Features in More Detail<br />

Instrument Display Form<br />

With HW3 running on a PC and a compatible instrument connected, the<br />

measured values with trend indicators are displayed live on the monitor,<br />

together with instrument identifi cation. From this view it is possible to<br />

activate data acquisition of the measured values directly to the PC’s hard<br />

drive.<br />

For handheld instruments this feature is useful for logging local conditions<br />

to the PC, or if a cable mounted probe is fi tted, conditions inside a climatic<br />

test chamber or incubator.<br />

Transmitters are displayed in the same way, and when a multi point transmitter<br />

network is used, 32 instruments, each with up to 2 probes can be<br />

monitored simultaneously.<br />

If alarms are programmed, visual indication on this display form can be<br />

supplemented with audible signals and user notifi cation via email or SMS<br />

messages.<br />

HW3 Vision Graphic Display Module<br />

HW3 Vision display module presents either logged data fi les or live<br />

measurements in a convenient graphical format (scrolling). From this<br />

screen graphs can be either directly printed, or copied and pasted into<br />

documents or reports. Usual data analysis tools such as zoom, ruler and<br />

gridlines are included.<br />

Various formatting options are available through on screen icons, these<br />

include changing the graph background, trace colour, legends, gridlines<br />

and axis. The base text used within the HW3 Vision graph display module<br />

can also be confi gured by the user to suit specifi c application or operational<br />

needs.<br />

Instrument Confi guration Form<br />

If the ROTRONIC instrument you purchase has an RS232 interface, the<br />

Instrument Confi guration Form provides you with the tools to fully confi -<br />

gure or reconfi gure directly from the PC.<br />

Using a system of confi guration upload and download means that settings<br />

can be stored on the PC for future use or reference. This also means that<br />

programming several instruments with the same confi guration can be less<br />

time consuming.<br />

<strong>Instruments</strong> settings that can be modifi ed through this option include;<br />

probe type, display settings, units of measurement (International variations<br />

all included), measuring ranges, psychrometric calculations, analogue<br />

output scaling and serial communications setting (data format, network<br />

address etc).<br />

Each instrument can also be digitally renamed by the user to enable identifi<br />

cation of use or location, and notes describing the instruments history<br />

can also be stored with the confi guration data on the PC’s hard drive.<br />

HygroData Quick<br />

All current versions of HW3 are shipped with advanced water activity analysis<br />

software integrated. To access this function requires an additional<br />

license; see ordering information. For a full description of this feature,<br />

please refer to the Water Activity section of this catalogue.<br />

SoftCal Probe Calibration<br />

One of the most important features of HW3 is the SoftCal utility that controls<br />

the calibration process of our digital probes, which of course do not feature<br />

traditional analogue potentiometers. Within SoftCal you can perform<br />

zero, slope and linearity adjustment for humidity, and zero and slope for<br />

temperature. It is also possible to make a single point adjustment against<br />

a defi ned reference.In all cases the user can choose defi ned ROTRONIC<br />

calibration values, or make their own selection. As a precaution against incorrect<br />

adjustments, SoftCal automatically rejects adjustments greater than<br />

5%rh, as this is likely to be an indication or incorrect calibration method, or<br />

a faulty instrument.


Psychrometric Calculations<br />

All ROTRONIC instruments measure percentage relative humidity<br />

(%rh) and temperature (°C/F). From the two values it is possible to calculate<br />

other psychrometric values such as dew-point, frost-point, wetbulb<br />

temperature, mixing ratio, absolute humidity, enthalpy, partial<br />

water vapour pressure, saturation vapour pressure and more.<br />

The calculation software in HW3 uses WMO* verifi ed formulae to<br />

make these calculations, and also provides the user with the option to<br />

input their own parameters (e.g. input mixing ratio & temperature to<br />

calculate %rh). Other advanced options such as dew/frost-differentiation,<br />

and pressure or altitude compensation are included.<br />

*World Meteorological Organisation<br />

Alarms<br />

Specifi cations and Hardware Requirements<br />

Processor Recommended Pentium 233 Mhz or better<br />

Operating System Microsoft Windows 95, 98, ME, NT, 2000<br />

Audio Sound card or integral speaker for playback of alarm .WAV fi les<br />

Network LAN or modem for email or SMS alarm feature<br />

Memory 64 Mb or better<br />

Disk space 20 Mb<br />

Monitor VGA/SVGA<br />

Resolution 800 600 or better, High Colour 16Bit or better (256 colour minimum)<br />

Connection RS232 (Com 1…4)<br />

Supply format CD (mini type suits all CD drives)<br />

Upgrades Available on-line to registered users<br />

Manual On CD HTML format<br />

HW3 Ordering Information<br />

HW3 Features and Ordering Information<br />

Our HygroPalm, HygroLab, HygroFlex and M Series instruments with<br />

RS232 interface can all provide a continuous stream of measurement<br />

data for display and data acquisition within HW3. It is also possible to<br />

defi ne 4 alarm limits (High and Low, humidity and temperature).<br />

When alarm conditions are reached, HW3 can inform the user with<br />

either audible (.WAV fi les) or visual indication. In addition, the software<br />

can be confi gured to send an email or SMS text message (requires<br />

LAN or Modem connection).<br />

HW3 is typically supplied as a HYGRODATA bundle with the serial RS232 cable to suit the different instruments,<br />

please consult the relevant section of this catalogue. The main options are detailed below:<br />

Order code Description RS232 Cable order code<br />

HW3 Software only supplied on CD ROM N/A<br />

HygroData HP HW3 software and connecting cable to suit HygroPalm 2 and 3 AC1622<br />

HygroData HL HW3 software and connecting cable to suit HygroLog AC1590<br />

HygroData Lab HW3 software and connecting cable to suit HygroLab 11.01.6218<br />

HygroData HTS HW3 software and connecting cable to suit HygroFlex 2 and 3 AC1627<br />

HygroData Quick Upgrade License to add AW Quick modes to HW3 N/A<br />

H<br />

W<br />

3<br />

S<br />

O<br />

F<br />

T<br />

W<br />

A<br />

R<br />

E<br />

103


T<br />

H<br />

E<br />

O<br />

R<br />

Y<br />

104<br />

Theory<br />

Humidity measurement in air<br />

Humidity in the form of water vapour is always present in the air. It is measured either as absolute or relative<br />

humidity. These two terms are defi ned as follows:<br />

Absolute humidity of a gas mixture<br />

The absolute humidity of a gas mixture is defi ned as the quantity of water vapour (kg) contained in each<br />

volume of the gas mixture. It is expressed in terms of kg water vapour per kg gas mixture.<br />

The water vapour present in the gas mixture generates a pressure, which is part of the total barometric<br />

gas pressure. The vapour pressure and the absolute humidity cannot exceed the saturation level at a given<br />

temperature. Above this level, water is separated out in liquid form. The maximum pressure is described as<br />

saturation pressure and is highly temperature-dependent.<br />

The absolute humidity of the air is of limited practical signifi cance, because one essential factor, the temperature,<br />

is not taken into account in the determination of absolute humidity.<br />

Relative humidity of a gas mixture<br />

Relative humidity is defi ned as the ratio of the actual water vapour pressure to the highest possible water<br />

vapour pressure:<br />

%rh = 100 x p/ps<br />

p = Water vapour pressure in the<br />

gas mixture at ambient temperature<br />

ps = Saturated water vapour pressure<br />

at ambient temperature<br />

Therefore, 100%rh corresponds to the maximum amount of water vapour, which a gas mixture can contain.<br />

Below the saturation level, the water vapour pressure p and hence also the relative humidity (%rh) are proportional<br />

to the total barometric pressure. Since the highest possible water vapour pressure ps is extremely<br />

temperature-dependent, the relative humidity is also temperature-dependent. The relative humidity therefore<br />

decreases, when the temperature rises, and vice versa.<br />

Infl uence of temperature fl uctuations of ±1°C at various temperatures and humidities:<br />

%rh 10 °C 20 °C 30 °C 50 °C 70 °C<br />

10 %rh ±0.7% ±0.6% ±0.6% ±0.5% ±0.5%<br />

50 %rh ±3.5% ±3.2% ±3.0% ±2.6% ±2.3%<br />

90 %rh ±6.3% ±5.7% ±5.4% ±4.6% ±4.1%<br />

It is extremely important that the probe and the sample to be measured have the same temperature to<br />

achieve useful measurements.<br />

To gain a better understanding of the relationships, we refer to the h-x diagram of humidity in air<br />

(Mollier’s diagram). This illustrates clearly the relationship between temperature, moisture content and relative<br />

humidity.<br />

Relative humidity below 0°C<br />

At temperatures below 0°C, the saturation pressure above water in liquid form (supercooled): e w differs<br />

from the saturation pressure above ice: e i .<br />

e w = Water vapour saturation pressure<br />

e i<br />

above water at ambient temperature<br />

= Water vapour saturation pressure<br />

above ice at ambient temperature<br />

T e w e i %rh<br />

°C hPa hPa –<br />

0 6.11 6.11 100<br />

–5 4.22 4.02 95<br />

–10 2.87 2.60 91<br />

–15 1.91 1.65 87<br />

–20 1.26 1.03 82<br />

–25 0.81 0.63 78<br />

–30 0.51 0.38 75<br />

For this reason, a measurement of 75%rh at -30°C corresponds to saturation (100%rh) above ice.


Humidity measurement in solids<br />

Theory<br />

Similar to gases, solids such as paper or food can also absorb and retain water or desorb it. Materials with<br />

this property are called hygroscopic. Depending on the point of view, there are two different observations<br />

that characterise the humidity state of a material.<br />

Water content<br />

The water content of a material is the amount of water contained in the material, expressed in percentage<br />

of weight. This aspect is interesting for situations, where a material is sold by weight. However, if we talk of<br />

the physical properties of a material, then the water content is of no interest, as it provides no meaningful<br />

information.<br />

Equilibrium humidity<br />

A hygroscopic material tries to establish equilibrium of its humidity with that of its environment. The presence<br />

of water in the material produces a water vapour pressure (pm) on the material surface. If this pressure<br />

(pm) is equal to the water vapour pressure (p) of the ambient atmosphere, then the material achieved<br />

equilibrium humidity with its environment. Any difference between the pm and the p produces a water exchange<br />

and therefore a change of the water content of the material concerned, until equilibrium is achieved.<br />

Equilibrium humidity of a material is therefore defi ned as the relative humidity of the ambient atmosphere<br />

that has to prevail in order to cause no exchange of water.<br />

Water activity<br />

The relative humidity, which must prevail in the surrounding atmosphere to avoid water exchange between<br />

material and air, is defi ned as water activity. It is practically the same as the equilibrium humidity of a material<br />

in the defi nition, but is not stated in 0….100%, but in 0…1Aw. The water activity is a measure of the<br />

degree of freedom of the water retained in various ways in a material.<br />

The water activity directly determines the physical, mechanical, chemical and microbiological properties of<br />

the material as well as interactions, such as pourability, lump formation, cohesion, static electricity, etc. In<br />

the food industry, water is a highly signifi cant factor in the shelf life of semi-fi nished and fi nished products.<br />

Sorption isotherms<br />

At equilibrium, the relation between water content and equilibrium humidity of a material can be displayed<br />

graphically by a curve, the so-called sorption isotherm.<br />

For each humidity value, a sorption isotherm indicates the corresponding water content value of the material<br />

at a given, constant temperature. If the composition or quality of the material changes, then its sorption<br />

behaviour also changes. Because of the complexity of sorption processes, the isotherms cannot be determined<br />

by calculation, but must be recorded experimentally for each product. Therefore in practice, water<br />

content and water activity should be viewed as two independent parameters.<br />

T<br />

H<br />

E<br />

O<br />

R<br />

Y<br />

105


T<br />

H<br />

E<br />

O<br />

R<br />

Y<br />

106<br />

h-x diagram


1 Explanations of characters<br />

Explanations to the h-x diagram<br />

1.1 ß: Dry air quantity in kg per m 3 process air<br />

1.2 t: Temperature of the process air in °C<br />

1.3 x: Water vapour content in g per kg dry air of the process air<br />

1.4 h: Heat content (enthalpy) in kJ per kg dry air of the process air<br />

1.5 ϕ: Relative humidity of the proces air<br />

1.6 Δh : Heat consumption in kJ per kg water<br />

Δx<br />

NB: We designate prcess air as air in different states, as found during drying (fresh air/warmed<br />

air from the furnace and/or a heater/conditioned air, also exhaust air).<br />

2. Use of the h-x diagram<br />

2.1 Dry air porition ß in kg per m 3 process air<br />

Example:<br />

Measured values of the exhaust air in a drying plant tA=46°C; ϕ = 80%rh;<br />

exhaust air quantity 12000m 3 /h<br />

The line drawn parallel to the dotted lines of the diagram through the status point of the exhust<br />

air (Intersection of the t-line 46°C and the humidity curve 80%) results in its extension at<br />

the Intersection with the left margin scale at ß=1,018kg dry air per m 3 of this exhaust air. At<br />

12000m 3 /h, the dry air quantity is thus 12000 • 1,018=12200kg/h.<br />

2.2 Water vapour content in g per kg dry air of the process air<br />

2.2.1 The vertical line drawn through the status point (in our example 46°C; 80 %rh) results at the<br />

intersection with the horizontal abscissa a water vapour content of x 2 =54g per kg dry air of this<br />

exhaust air.<br />

2.2.2 If the hot air fed into the drying chamber is created by heating outside air (in the example temperature<br />

20°C; 70%rh) this hot air brings x 1 = hot water per kg dry air with it (determined<br />

of x 1 = 10g hot water per kg dry air with it (determination of x 1 as described in 2.2.1]).<br />

this means that each kg of dry air has absorbed Δx = x 2 - x 1 =44g Wasser aufgenommen hat.<br />

2.2.3 With 12200kg dry air/h, 12200 • 0,044=536,8kg water are withdrawn from the product being<br />

dried per hour.<br />

2.3 Heat content inkJ per kg dry air of the processed air.<br />

2.3.1 The line drawn parallel to the lines of equal heat content (h lines) through the status point (in<br />

our example 46°C; 80%rh) results on the one hand at the intersection with the inclined abscissa<br />

in a heat content h 2 =185kJ/kg dry air of this exhaust air.<br />

(Conversion to kcal: 1kcal=4,1868kJ).<br />

On the other hand this extended parallel line in the upper part of the diagram helps to determine<br />

the approximate hot air temperature (see 2.5) for this heat content.<br />

2.3.2 The heat content of the outside air (in our example 20°C; 70%) is h 1 =45kJ,<br />

(determined as described in 2.3.1) so that heating by Δh=h 2 -h 1 =140kJ per kg dry air is necessary<br />

for drying.<br />

However, the actual heating must be higher than this Δh, due to various heat losses such as<br />

radiation, heating of the goods to be dried, the drying cars and frame etc. But for well insulated<br />

plants, no more than 15 kJ/kg dry air.<br />

2.3.3 The theoretical heat consumption in our example is thus:<br />

12200 • 140=1,708 million kJ/h.<br />

2.4 Theoretically required heat quantity per kg of expelled water:<br />

The parallel line drawn through the zero point to the connecting line of the status points for outside<br />

air and exhaust air indicates the theoretical heat consumption at the intersection with the right margin<br />

scale:<br />

Δh<br />

=318<br />

kJ<br />

theor. heat consumption<br />

Δx kg<br />

per kg H2O calculation:<br />

Δh (from 2.3.2) = 140 = 3182 kJ<br />

Δx (from 2.2.2) 0,044 kg<br />

2.5 Hot air temperature<br />

The vertical line drawn through the status point of the outside air (see 2.2.2) intersects with the h line<br />

of the exhaust air (see 2.2.1) at a particular point. If one draws a line through this point parallel to the<br />

lines of equal temperature (t lines), one obtains the theoretically required hot air temperature at the<br />

intersection with the ordinate, in our example 157°C.<br />

T<br />

H<br />

E<br />

O<br />

R<br />

Y<br />

107


T<br />

H<br />

E<br />

O<br />

R<br />

Y<br />

108<br />

Humidity defi nitions<br />

Theory<br />

Relative humidity (%rh)<br />

Is defi ned as the ratio of the quantity of water vapour present in the air to the maximum possible water vapour<br />

at the same temperature.<br />

Dew point (Dp)<br />

The dew point is that temperature, where gas being cooled, begins to condense water vapour into liquid<br />

water. The dew point may also occur below 0°C (super-cooled water). This point has to be distinguished<br />

from freezing point (see below).<br />

Frost point (Fp)<br />

The frost point is that temperature, where gas being cooled begins to condense water vapour in the form of<br />

ice. Freezing point occurs only at temperatures below freezing.<br />

Water vapour density (Dv) in g/m 3<br />

This is the ratio between the mass of the water vapour to the volume of the gas mixture, in which the water<br />

vapour is.<br />

Water vapour content (Q) in g/kg<br />

This is also called specifi c humidity and is the ratio between the mass of the water vapour to the mass of<br />

the gas mixture, in which the water vapour is.<br />

Mixing ratio ( R) in g/kg<br />

This is the ratio of the mass of the water vapour to the mass of the dry gas mixture, in which the water vapour<br />

is.<br />

Water vapour partial pressure (E) in hPa<br />

This is the pressure of the gaseous phase of the water in a gas mixture.<br />

Water vapour saturation pressure (Ew) in hPa<br />

This is the maximum pressure that the water vapour can reach at saturation for the appropriate temperature.<br />

Enthalpy (H)<br />

Enthalpy is the measurement for the determination of the energy required, to change the gas mixture from<br />

a certain temperature/humidity state to another. Enthalpy is not used as an absolute value, but as the difference<br />

between two points of particular interest. The choice of 0 °C and 0 %rh for zero enthalpy was arbitrary.<br />

Mixing ratio/Volume (PPMv)<br />

This is the relationship between the number of water vapour molecules to the number of molecules of the<br />

other components in the gas. Once this value is determined, it does not change with pressure or temperature.<br />

Common faults/remedies<br />

Not only humidity, but also many other physical parameters are measured in industrial processes. The<br />

most important are temperature, pressure, air speed, etc. The measurement of humidity is different to other<br />

parameters in one important aspect, namely that humidity cannot be considered as an absolute value, because<br />

the measuring principle is based on the exchange of water vapour between the sensor and the surrounding<br />

gas or gas mixture, e.g. air.<br />

In our capacity as experienced manufacturer, we are well aware of our responsibility to provide our customers<br />

with instruments, that will withstand even the most demanding operating conditions and which<br />

are at the same time easy to use and require little maintenance. However, we wish to remind our customers,<br />

that our instruments will provide an excellent service and provide accurate results, if the following list<br />

of simple operation and maintenance instructions are followed:<br />

1. Analysis of the measuring medium, in which the probe is to be used. What suspended matter and/or<br />

chemicals are present and in what concentration?<br />

2. The probe should be mounted at the correct measuring location, and not where it is most convenient.<br />

3. In case of doubt please contact your ROTRONIC representative.<br />

4. The fi lter has to be changed regularly, if the probe is used in demanding environments. ROTRONIC fi lters<br />

can be cleaned in an ultrasonic bath with suitable detergents. However, it is advisable to keep a spare set<br />

in stock.<br />

5. The perfect function of the sensor should be checked every 6 to 12 months.<br />

6. Calibration of the sensor can be performed by the user with the help of the SCS certifi cated humidity<br />

standards, supplied by ROTRONIC. Calibration of the instruments will ensure, that your measurements<br />

are always verifi able.


ROTRONIC Humidity sensors<br />

Theory<br />

With the HYGROMER ® series, ROTRONIC provides the most advanced capacitive polymer sensor system<br />

for relative humidity measurement. It is the sensor with the largest temperature range (-50…200 °C) available<br />

on the market. This measuring principle is recognised internationally and is based on the change of the<br />

dielectric properties of a polymer as a function of the prevailing relative humidity. The polymer used for<br />

the HYGROMER ® sensor is hygroscopic and has a natural tendency towards equilibrium with the humidity<br />

environment which surrounds it. A corresponding water vapour pressure is formed at the surface of the<br />

polymer depending upon the temperature and the amount of water absorbed into the polymer. Any difference<br />

between this water vapour pressure and the water vapour pressure of the environment is balanced<br />

by an exchange of water molecules until the two are equal. These changes are measured electrically, amplifi<br />

ed and indicated as relative humidity. The amount of water which is absorbed into the polymer is determined<br />

by the ambient humidity and temperature, thus the resulting dielectric properties of the sensor<br />

refl ect the percentage relative humidity (%rh) to which the sensor is exposed.<br />

For many years, the ROTRONIC HYGROMER ® C94 was the best sold sensor. With the disappearing of the<br />

Hygrolyt sensors, new elements were developed in order to even better fulfi l the customers requirements.<br />

An industry sensor does not necessarily need the same properties as a sensor for Water Activity or a sensor<br />

for high-humidity applications. The new sensors represent the results of a continuous research and development.<br />

Sensor Designation Used for Improvements:<br />

HYGROMER ® IN-1 Industry applications Gold connectors,<br />

Temperature range: Meteorology better chemical resistance,<br />

-50...200°C Food technology no corrosion after condensation<br />

Laboratories<br />

Cold rooms<br />

Drying processes<br />

Incubators<br />

HYGROMER ® AC-1 HVAC applications Better chemical resistance,<br />

Temperature range: Cold rooms better Long-term-stability<br />

-30...100°C Storage and transport<br />

Wine cellars<br />

Greenhouses<br />

Museums<br />

Churches<br />

HYGROMER ® WA-1 Water Activity- applications Optimised dimensions for<br />

Temperature range: Food/pharma quality assurance minimal chamber volume,<br />

-30…100°C Product stability Very little hysteresis<br />

Shelf life determination<br />

HYGROMER ® RS-70 High humidity- applications Heated sensor,<br />

Temperature Range: Cheese stocks no condensation,<br />

-50…180°C Meat processing better accuracy in<br />

Tropical greenhouses high range of humidity<br />

Test environments<br />

Climatic chambers<br />

HYGROMER ® RS-20 Brick- and tile making Mechanical stability<br />

Temperature range: Wood-industry Fast response<br />

-50…180°C<br />

HYGROMER ® humidity sensors are always fi tted to a probe or instrument. Thanks to the ROV interface,<br />

probes and instruments with HYGROMER sensors can be connected to any display unit with ROV input.<br />

(10 mV/ °C and 10 mV/%rh)<br />

Characteristics of the sensor<br />

Response time/Time constant<br />

The time constant of a sensor is defi ned as the time required to perform 63% of a humidity change. The<br />

time constant is larger at low temperature, low air movement and high humidity. The time constant also<br />

increases when a fi lter is used. The fi lter reduces the airfl ow over the sensor and a slower diffusion of water<br />

molecules results in a slower response time. Therefore humidity equilibrium is reached after an extended<br />

period of time.<br />

Reproducibility<br />

The specifi cations stated refer to a humidity cycle of 10-95-10 %rh.<br />

T<br />

H<br />

E<br />

O<br />

R<br />

Y<br />

109


T<br />

H<br />

E<br />

O<br />

R<br />

Y<br />

110<br />

Pollutant table<br />

Theory<br />

The following gases have, in the given concentrations, no or little infl uence on the sensor and the humidity<br />

measurement. The data is only a guide. The resistance of the sensor depends strongly on the temperature<br />

and humidity conditions and the duration of the exposure to the pollutant.<br />

Allowed fault caused from the pollutant: ±2%rh<br />

Pollutant Formula Maximum Workplace Allowed Concentration<br />

Concentration Continuous Operation<br />

ppm mg/m 3 ppm mg/m 3<br />

Acetic acid CH3COOH 10 25 800 2000<br />

Acetone CH3COCH3 1000 2400 3300 8000<br />

Ammonia NH3 25 18 5500 4000<br />

2-Butanone (MEK) 300 1200 150000<br />

Chlorine Cl2 0.5 1.5 0.7 2<br />

Ethanol C2H5OH 1000 1900 3500 6000<br />

Ethyl acetate CH3COOC2H5 400 1400 4000 15000<br />

Ethylene glycol HOCH2CH2OH 100 260 1200 3000<br />

Formaldehyde HCHO 1 1.2 2400 3000<br />

Hydrochloric acid HCl 5 7 300 500<br />

Hydrogen sulphide H2S 10 15 350 500<br />

Isopropanol (CH3)2CHOH 400 980 4800 12000<br />

Methylethylketon C2H5COCH3 200 590 3300 8000<br />

Nitrogen oxides NOx 5 9 5 9<br />

Ozone O3 0.1 0.2 0.5 1<br />

Sulphur dioxide SO2 5 13 5 13<br />

Toluene / Xylene C6H5CH3 100 380 1300 5000<br />

Xylol C6H5(CH3)2 100 440 1300 5000<br />

Practical limits<br />

The specifi ed operating ranges must be complied with, otherwise signifi cant errors can arise or the measuring<br />

element could be destroyed.<br />

A replaceable dust fi lter must be used in dusty environment.<br />

Oil and grease vapours will damage the sensor, as they can condense on the sensor and thus prevent or<br />

inhibit response (insulating layer). Flue gases can therefore not be measured .<br />

A fi lter must be used at air velocities above 3 m/s. The sensor must also be protected mechanically from the<br />

high air velocities above 40 m/s (for fi lters, see general accessories).<br />

Sensor properties HYGROMER ®<br />

Operating range IN-1 AC-1 WA-1 RS-20 RS-70<br />

Humidity 0…100%rh<br />

Temperature in °C -50…200 -30…100 -20…180<br />

Air velocity in m/s without<br />

ohne Sensorschutz 3 m/s<br />

Air velocity in m/s with sensor<br />

protection sensor protection 20–40 m/s<br />

Output signals capacitance range<br />

Reproducibility better than 0.5%rh<br />

Long-term stability


Alphabetical Index<br />

Keyword Page<br />

A<br />

A1 11, 13<br />

AC-Adaptor 24<br />

Agent-Accessories 24<br />

Agent-D HT2-EX 20<br />

Agent-D-DataP 24<br />

Agent-D-NT3 20<br />

Agent-D-PT4 20<br />

Alarm device 44–45<br />

Anti theft device 24<br />

AW Quick function 78<br />

B<br />

Bacteria 76<br />

C<br />

Calibration device 98<br />

Carrying case AC1115 11<br />

Ceramics industry 27<br />

Customer branding 92, 93<br />

D<br />

Dataloggers 14<br />

Digital output signal 31<br />

Docking station 5<br />

Drying process 27<br />

E<br />

Equilibrium relative humidity 76, 85<br />

Extension cable 39<br />

F<br />

FDA21 CFR Part 11 100<br />

Filters 36, 39, 57<br />

G<br />

GTS-Set 11<br />

H<br />

Halophile bacteria 76<br />

High temperature applications 27, 29, 34<br />

HPH Signal booster 66<br />

Humidity standard 96, 97<br />

HumidityTheory 104<br />

HW3 software 16, 100<br />

hx diagram 106<br />

HygroClip, various 8, 9, 18, 19, 34, 35, 37, 39,64<br />

Hygrodata quick 102<br />

HygroFlex 30ff<br />

HygroLab 80<br />

HygroLog Accessories 24<br />

HygroLog, HygroLogD 16<br />

Hygromer sensor 109<br />

HygroPalm /1/2/3 16<br />

HygroPalm Aw1 81<br />

HygroPalm-Set 10<br />

Hygrowin 65<br />

I<br />

I-1000 Transmitter 56–61<br />

Impact protection 24<br />

Industrial probes 34 ff<br />

Installation 43<br />

Intrinsically safe 56<br />

Humidity and temperature measurement<br />

Keyword Page<br />

M<br />

M1/M2/M3 48–52<br />

Meteorology probes 71–75<br />

Mildew 76<br />

MOC, MOC3 64<br />

Moisture content 85<br />

MOK, MOK3, MOK-WIN 50, 64, 65<br />

Mounting Accessories 60<br />

M-Series Transmitter 46ff<br />

N<br />

Networking 24<br />

O<br />

OEM Products, OEM Sensors 92ff<br />

Osmiophile yeast 76<br />

P<br />

Paper industry 11, 27<br />

Pollutant table 110<br />

Portable Analyser 76, 81<br />

PPS probe 8, 56<br />

Pressure probe 32<br />

Printer, Printer cable 24<br />

Probe extension cable 24, 36, 65<br />

Probe Simulator 65<br />

Psychrometric calculations 103<br />

R<br />

Radio Option 33<br />

Remote control<br />

Roline L Transmitters 53–55<br />

S<br />

SCS 46, 97<br />

Sensor protection 36<br />

Software validation 16, 100ff<br />

T<br />

Temperature Adaptor 12<br />

Temperature Logger 20<br />

Temperature probes 22<br />

Transmitter 28ff<br />

V<br />

VHTS2-shield 70, 74<br />

W<br />

Wall mounting bracket 24<br />

Water Activity 76ff<br />

Weather protection shield 70<br />

X<br />

Xerophile mildew 76<br />

Y<br />

Yeast 41<br />

Z<br />

Zener barrier 37, 39<br />

I<br />

N<br />

D<br />

E<br />

X<br />

111


O<br />

N<br />

-<br />

L<br />

I<br />

N<br />

E<br />

S<br />

H<br />

O<br />

P<br />

S<br />

112<br />

Switzerland:<br />

www.humidity-shop.ch<br />

www.humidity-shop.ch<br />

France:<br />

www.rotronic.fr<br />

www.rotronic.fr<br />

ROTRONIC On-Line Shops<br />

Visit us On-Line!<br />

Germany:<br />

www.rotronic-shop.de<br />

www.rotronic-shop.de<br />

England:<br />

www.humidity-shop.co.uk<br />

www.humidity-shop.co.uk


1. General<br />

1.1 These general conditions of sale and supply<br />

shall be binding when such have been<br />

stated as being applicable in an offer or<br />

confi rmation of order of and by ROTRONIC<br />

<strong>Instruments</strong> (UK) Ltd<br />

1.2 Orders shall only become binding upon<br />

ROTRONIC <strong>Instruments</strong> (UK) Ltd after it has<br />

issued a written confi rmation of order.<br />

1.3 These general conditions of sale and supply<br />

shall become valid as from January 1, 2000.<br />

2. Prices<br />

Prices shall be deemed net plus transportation<br />

and packaging charges (V.A.T. at prevailing rate<br />

applies), provided that alternative conditions have<br />

not already been agreed. ROTRONIC <strong>Instruments</strong><br />

(UK) Ltd however hereby reserves the right to<br />

make price adjustments to cover defi nite increases<br />

in costs as for example the cost of wages, goods<br />

and materials.<br />

3. Delivery period<br />

The delivery period shall be the date laid down<br />

in the contract of sale and such may be extended<br />

should diffi culties arise that may have been caused<br />

by act of God or force majeure such as war, epidemics<br />

and among other things storm and tempest.<br />

4. Despatch<br />

All deliveries shall be effected for the account and<br />

the risk of the customer. Any complaints concerning<br />

damage, loss or delay are to be reported to<br />

ROTRONIC <strong>Instruments</strong> (UK) Ltd within 7 days after<br />

the receipt of the consignment; but complaints<br />

concerning any faulty packaging shall be rendered<br />

on the same day as the receipt of the consignment.<br />

5. Works deliveries<br />

Should the consignment and invoicing be directly<br />

effected by the works supplier of ROTRONIC<br />

<strong>Instruments</strong> (UK) Ltd, the conditions of sale and<br />

supply of that particular works supplier shall be<br />

valid for customers in respect of that particular<br />

contract. In such cases, these present conditions<br />

of sale and supply shall have no validity and damage<br />

indemnity claims or claims of any other nature<br />

cannot be made enforceable against ROTRONIC<br />

<strong>Instruments</strong> (UK) Ltd hereunder.<br />

6. Return of goods and materials<br />

The return of goods and materials shall require<br />

the written permission of ROTRONIC <strong>Instruments</strong><br />

(UK) Ltd and may only be effected if the goods and<br />

materials are in irreproachable condition and still<br />

in their original packaging, and only then if such<br />

are usually maintained in stock by ROTRONIC<br />

<strong>Instruments</strong> (UK) Ltd. A copy of the delivery note<br />

or the invoice must be enclosed. Returns without<br />

either a copy of the delivery note or the invoice will<br />

not be accepted. An appropriate surcharge will be<br />

levied by ROTRONIC <strong>Instruments</strong> (UK) Ltd on the<br />

purchaser to defray the cost of any inconvenience<br />

caused.<br />

Terms and Conditions of Trading<br />

7. Settlement<br />

Provided that alternative conditions have not already<br />

been agreed, invoices are to be settled net<br />

within 30 days without any deductions. Purchasers<br />

will be charged the usual bank overdraft rate of interest<br />

in respect of overdue payments.<br />

8. Retention of ownership rights<br />

All goods and materials supplied shall remain the<br />

property of ROTRONIC <strong>Instruments</strong> (UK) Ltd until<br />

full payment of the debited invoice amount shall<br />

have been received. The purchaser and the holder<br />

of the goods and materials shall in addition be under<br />

a duty hereunder to contract insurance cover<br />

for the goods and materials and, in their capacity<br />

as the insured, to assign any insurance claim of the<br />

purchaser to ROTRONIC <strong>Instruments</strong> (UK) Ltd<br />

9. Warranty<br />

ROTRONIC <strong>Instruments</strong> (UK) Ltd will grant a warranty<br />

for plant and equipment for a period of 24<br />

months from the date of delivery in respect of<br />

any evidenced faulty workmanship and materials.<br />

Should a delivered consignment prove to be<br />

contrary to contract upon inspection, the customer<br />

shall grant ROTRONIC <strong>Instruments</strong> (UK) Ltd the<br />

opportunity hereunder of removing the fault, or<br />

else the customer may demand replacement.<br />

Should the supply or delivery of any improvement<br />

or replacement not prove possible, the customer<br />

may choose between having the purchase price<br />

reduced or in demanding the contract of, sale to<br />

be rescinded (conversion). Damage resulting from<br />

natural wear and tear, act of God, force majeure,<br />

non compliance with the operating instructions<br />

shall be excluded from the warranty as well as mechanical<br />

interference by the customer or by third<br />

parties with plant and equipment of ROTRONIC<br />

<strong>Instruments</strong> (UK) Ltd without its written permission.<br />

10. Cancellation<br />

Cancellation of orders shall only be possible hereunder<br />

with the written approval of ROTRONIC<br />

<strong>Instruments</strong> (UK) Ltd. Any costs which shall have<br />

already been incurred or price increases as a result<br />

of reductions in amounts ordered shall be for the<br />

account of the purchaser. Partial supplies of an<br />

order contracted upon call shall be claimed within<br />

the agreed supply and delivery periods, otherwise<br />

ROTRONIC <strong>Instruments</strong> (UK) Ltd may cause the<br />

relative consignment and invoice billing there fore<br />

to be made.<br />

11. Place of jurisdiction<br />

The place of jurisdiction hereunder shall be<br />

London, England. The purchaser expressly declares<br />

and agrees hereunder to waive the usual<br />

place of domicile as place of jurisdiction in favour<br />

of the foregoing jurisdiction agreed hereunder.<br />

Legal relationships hereunder shall be subject to<br />

UK law.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!