HUMIDITY / TEMPERATURE MEASUREMENT - Omni Instruments
HUMIDITY / TEMPERATURE MEASUREMENT - Omni Instruments
HUMIDITY / TEMPERATURE MEASUREMENT - Omni Instruments
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
1<br />
<strong>HUMIDITY</strong> / <strong>TEMPERATURE</strong><br />
M E A S U R E M E N T<br />
2 0 0 2 / 2 0 0 3<br />
UK / Europe / USA Office<br />
Tel: +44 (0)8700 434040<br />
Fax: +44 (0)8700 434045<br />
E-mails - info@omniinstruments.co.uk<br />
East Kingsway Business Centre<br />
Mid Craigie Trading Estate<br />
Mid Craigie Road,Dundee DD4 7RH UK
Rotronic have been manufacturers of humidity instruments since 1967. Our products have been<br />
developed over the years to provide accurate and dependable measurements in a wide range of applications,<br />
at competitive prices, and with features which our customers appreciate. Throughout this<br />
catalogue, you will fi nd a range of units which solve the measurement requirements in almost any<br />
application.<br />
All products are developed and manufactured at our headquarters in Switzerland, where we maintain<br />
an ISO9001 quality system, as well as an accredited calibration laboratory, and a full repair facility.<br />
We have a worldwide network of subsidiary companies and distributors, who are highly trained<br />
to support the ROTRONIC product range.<br />
When you specify a ROTRONIC product, you can expect:<br />
ROTRONIC – The Company<br />
• High accuracy sensing technology.<br />
• Excellent long term measurement stability.<br />
• Sensors with a high resistance to condensation and chemical pollution.<br />
• Full calibration adjustment facilities.<br />
• Traceable humidity calibration standards.<br />
• Expert product support throughout the life of the product<br />
Many famous international organisations place their trust in ROTRONIC measurement systems, our<br />
customer list includes:<br />
SIEMENS DEUTSCHER WETTERDIENST NASA<br />
BARILLA HONEYWELL<br />
NOVARTIS INTEL ROCHE<br />
AGFA-GEVAERT NESTLÉ<br />
MÉTÉO FRANCE BAYER HOFFMAN-LA-ROCHE<br />
PROCTER & GAMBLE KNORR<br />
JOHNSON CONTROL PHILIP MORRIS HEWLETT PACKARD<br />
KODAK CLARIANT<br />
I<br />
N<br />
T<br />
R<br />
O<br />
D<br />
U<br />
C<br />
T<br />
I<br />
O<br />
N<br />
1
I<br />
N<br />
T<br />
R<br />
O<br />
D<br />
U<br />
C<br />
T<br />
I<br />
O<br />
N<br />
2<br />
ROTRONIC Technology<br />
The measurement of humidity is a complex science, and over many years we have continuously developed<br />
our products to provide higher precision, better long term stability and the features our customers<br />
demand. There are certain core technologies which are common to many of our products, and which differentiate<br />
ROTRONIC instruments from many alternatives on the market:<br />
Hygromer ® Sensor.<br />
The Hygromer sensor was fi rst introduced in 1979 in response to market<br />
demand for higher performance and lower costs. Since its launch,<br />
it has constantly been developed using the highest quality materials<br />
and the state-of-the-art production techniques.<br />
Today it still has the widest operating range of any %rh sensor on the<br />
market, working over the ranges of 0…100 %rh and –50…200 °C. It’s<br />
superb reputation for long term stability is second to none, and many<br />
examples can be seen in use after more than 20 years. It is also able to<br />
withstand exposure to condensation without affecting calibration.<br />
The Hygromer ® sensor is used in every product carrying the<br />
ROTRONIC brands HYGROMER ® and HYGROCLIP ® . Several versions<br />
are available with different characteristics, see page 109 for more information.<br />
The HygroClip ® Concept.<br />
HygroClip ® is a humidity and temperature measurement concept<br />
utilising an exclusive digital semiconductor technology. It is based<br />
on a custom ASIC*, designed specifi cally for humidity and temperature<br />
measurement applications and works in conjunction with the<br />
Hygromer sensor.<br />
Products based on HygroClip ® technology include features such as<br />
probe interchangeability, digital signal processing, digital calibration<br />
and much more.<br />
HygroClip technology is used in every product carrying the ROTRONIC<br />
HYGROCLIP ® brand.<br />
* Application Specifi c Integrated Circuit<br />
Custom Mechanical Components<br />
The precise measurement of humidity needs careful consideration of<br />
temperature. Even the best humidity sensor and electronics cannot<br />
compensate for mechanical components that do not respond quickly<br />
to temperature changes.<br />
Our in house design team have therefore created a range of custom<br />
mechanical components which provide the best combination of mechanical<br />
strength and optimum thermal properties to ensure that sensors<br />
have the best possible chance of accurate measurements.<br />
Compensation<br />
Hygrometers are usually only factory adjusted at ambient temperature,<br />
so ROTRONIC humidity instruments feature dynamic temperature<br />
compensation to ensure that measurement values are optimised<br />
across the entire working range. Even if you purchase a transmitter<br />
that measures humidity only, you will fi nd a temperature sensor integrated<br />
into the probe for this purpose. Our SCS laboratory can provide<br />
calibrations at higher or lower temperatures if required.<br />
Thanks to the use of the latest digital technology, ROTRONIC humidity<br />
instruments can also be specifi ed to include dynamic pressure compensation.
Contents<br />
Section Products: Page number range:<br />
Handheld <strong>Instruments</strong> HygroPalm, HygroClip probes, A1, GTS 4 - 13<br />
Dataloggers HygroLog, HygroClip probes, Agent D, Agent probes 14 - 25<br />
Transmitters HygroFlex, M-Series, Roline-L Series 26 - 67<br />
Meteorology MP100/400, MP100/400H, Mounting hardware 68 - 75<br />
Water Activity HygroLab, Aw Quick, AW-DIO, HygroClip probes 76 - 87<br />
Temperature Temperature Transmitters and Handhelds 88 - 91<br />
OEM Products HygroClip, OEM options 92 - 95<br />
Calibration SCS calibration standards, calibration devices 96 - 99<br />
HW3 Software Features and options 100 - 103<br />
Theory Sensors, defi nition, pollutant tables 104 - 110<br />
Index 111<br />
I<br />
N<br />
T<br />
R<br />
O<br />
D<br />
U<br />
C<br />
T<br />
I<br />
O<br />
N<br />
3
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
4<br />
Handheld <strong>Instruments</strong><br />
Measurement of humidity and temperature is essential in many production, storage, transportation, and<br />
test applications. Many processes can only be performed if humidity and temperature conditions are within<br />
a specifi c range. Materials and products do not perform correctly if climatic conditions are incorrect.<br />
The ROTRONIC handheld instruments are the perfect tool for portable measurements, which are the fi rst<br />
step to defi ne ambient conditions.<br />
Our range of handheld instruments are highly accurate, but are easy to use and maintain. Confi guration<br />
and programming is performed in the factory; however, certain models offer the possibility to alter the<br />
instrument programming to specifi c customer needs with user-friendly software or integrated keypad.<br />
A wide range of interchangeable probes means simple maintenance and application fl exibility.<br />
Key features<br />
• Accuracy and long term<br />
stability<br />
• Interchangeable digital sensor<br />
module<br />
• Compact, modern instruments<br />
• Large display with good contrast<br />
• HOLD Function<br />
• Wide range of probes<br />
• Battery powered<br />
Your benefi ts<br />
� Reliable data and reduced<br />
maintenance<br />
� Simple calibration & maintenance<br />
� Easy to use and handle<br />
� Clear observation of measured values<br />
� Reliably capture of measured values<br />
� One instrument – many applications<br />
� Suitable for use anywhere<br />
Section contents Page<br />
HygroPalm Handheld <strong>Instruments</strong> for HygroClip probes 6 to 7<br />
� Interchangeable probes<br />
� Large easy-to-read display<br />
� Optional Docking Station<br />
� Temperature adaptors<br />
� RS232 Interface<br />
HygroClip probes for HygroPalm Handhelds 8 to 9<br />
� Wide range of options to suit any application<br />
� 0…100%rh, -50…200 °C<br />
� 100% interchangeable without adjustment<br />
Accessories and Sets of HygroPalm <strong>Instruments</strong> 10<br />
� Complete equipment for measuring and calibration<br />
� Handy cases<br />
� Connecting cables<br />
A1 and GTS <strong>Instruments</strong> for Special Applications 11<br />
� Handheld for paper stacks<br />
� Sets including calibration material
Building Management / HVAC<br />
Accurate and reliable thermohygrometers<br />
are needed to verify<br />
correct system performance<br />
during commissioning. Rotronic<br />
handhelds and their ability to be<br />
calibrated on-site often settles<br />
disputes about whose instrument<br />
is correct!<br />
Climatic test cabinets<br />
Many products are tested over<br />
a variety of climatic conditions.<br />
The exceptionally wide measuring<br />
range of the ROTRONIC<br />
handheld units means these<br />
conditions can be easily spot<br />
checked.<br />
Paper Industry<br />
The fi rst ROTRONIC products<br />
were developed for the paper<br />
industry, and today we have<br />
the largest world-wide sales of<br />
sword hygrometers for paper<br />
stack monitoring.<br />
Handheld Applications<br />
Research<br />
Many research tests must have<br />
the humidity conditions defi ned<br />
for the results to be accepted or<br />
considered to be reliable.<br />
Health and Fitness Centres,<br />
Hospitals, Classrooms<br />
In public areas it is especially<br />
important to maintain correct<br />
humidity values to minimise<br />
health risks.<br />
Museums, libraries &<br />
art galleries<br />
Conservation applications<br />
require dependable measurements<br />
and low cost of ownership.<br />
Rotronic handhelds have<br />
been a mainstay in this markets<br />
for three decades.<br />
Warehouses & storage<br />
Many products need to be stored<br />
in certain conditions to remain in<br />
good condition.<br />
Industrial process monitoring<br />
The maximum measurement<br />
temperature of 200°C and the robust<br />
design of our probes means<br />
that even the most diffi cult process<br />
application can be checked<br />
with a ROTRONIC handheld.<br />
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
5
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
6<br />
HygroPalm Series<br />
Humidity and Temperature Display Instrument for digital HygroClip ® probes<br />
HygroPalm represents a new generation of portable humidity/temperature instruments utilising the very<br />
latest digital technology. The advantage of digital technology is clear; highest precision is assured thanks<br />
to data transmission in a digital form, which means no signal loss over extended cable lengths and no external<br />
interference can infl uence measured values. Calibration data is maintained within the probe, which<br />
means there is no need to calibrate the whole system, and probes can be interchanged in seconds.<br />
HygroPalm 1<br />
Key features:<br />
• Handheld display unit for humidity and temperature<br />
• Digital signal processing for maximum accuracy<br />
• Display of dew point or wet bulb temperature<br />
• Standard alkaline batteries used<br />
• Interface for HygroFlex Transmitters<br />
• One-point adjustment of probes<br />
• Operating range probes: -50…200°C, probe dependent<br />
Order code:<br />
HygroPalm 1 (probe must be ordered separately)<br />
HygroPalm 2<br />
Key features:<br />
• All functions of HygroPalm 1<br />
• Second probe input %rh and °C<br />
• Multiple point probe adjustment<br />
• RS232 PC interface<br />
• Calculation of various psychrometric parameters<br />
• Formula Editor<br />
Order code:<br />
HygroPalm 2 (probe must be ordered separately)<br />
HygroPalm 3<br />
Key features:<br />
• All functions of HygroPalm 2<br />
• Universal input for pressure, air-speed etc.<br />
• Dynamic pressure compensation<br />
• Bi-directional interface for HygroFlex transmitters<br />
• Formula Editor<br />
Order code:<br />
HygroPalm 3 (probe must be ordered separately)<br />
PalmDock Docking Station<br />
Benchtop docking station designed for use with all HygroPalm models<br />
for RS232* PC interface and power connection (with external power<br />
adaptor).<br />
* HygroPalm 1 does not feature RS232 interface.<br />
Order code:<br />
PD 1 without lock<br />
PD 2 with lock<br />
PalmDock-1 with HW3 Software* & datacable, without lock<br />
PalmDock-2 with HW3 Software, datacable, & lock<br />
AC1207 Power adapter<br />
* Further information in the chapter HW3 Software
Feature Overview<br />
Highly precise & stable humidity<br />
& temperature sensors<br />
Big display<br />
for easy readings<br />
HOLD function<br />
for display<br />
5-button keypad for<br />
easy operation<br />
Battery<br />
compartment<br />
HygroPalm<br />
Interchangeable probes<br />
Calibration can be updated or the<br />
range of applications changed<br />
by the simple connection of a<br />
different probe.<br />
Interface Connector<br />
for HygroFlex Transmitter<br />
Universal Probe Input<br />
Psychrometric<br />
calculations available<br />
Option: Lock<br />
Docking Station<br />
Socket for Power adaptor<br />
RS232 interface<br />
for use with a PC<br />
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
7
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
8<br />
HygroClip Probes for HygroPalm<br />
A range of probes for different applications are available for the HygroPalm display instruments.<br />
All probes are based on the digital HygroClip technology, and can be interchanged within seconds without<br />
need for recalibration. With special adaptor cables, even probes designed for transmitters may be used.<br />
HygroClip S/S1<br />
Standard sensor module for humidity and temperature.<br />
A wire mesh fi lter provides sensor protection against dust and<br />
high air velocity.<br />
Dimensions Ø15 x 100 mm. IP rating: IP65<br />
HygroClip S1 is specially calibrated and certifi ed to provide measurement<br />
accuracy of ±1 %rh.<br />
Measurement range: -40…85 °C , 0…100 %rh<br />
Accuracy (S1): ±1.0 %rh, ±0.2 K (at 23 °C)<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23 °C)<br />
Order code:<br />
HygroClip S1<br />
HygroClip S<br />
Ø: 15 mm Length: 100 mm<br />
HygroClip SC04 / SC05<br />
4/5 mm diameter cable probe for humidity and temperature measurements<br />
in small spaces such as product & packaging testing, concrete,<br />
electronic test and climatic chambers.<br />
Cable length 2m<br />
Measurement range: -40…100 °C , 0…100 %rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip SC04 4 mmØ probe<br />
HygroClip SC05 5 mmØ probe<br />
Ø: 4/5 mm Cable: 2 m<br />
HygroClip HK 25 /HK40<br />
High temperature probe for measurements in ducts, dryers,<br />
climatic chambers etc. Probe length 250 or 400 mm.<br />
Measurement range: HK25: -50…150 °C, 0…100 %rh<br />
HK40: -50…200 °C, 0…100 %rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip HK25 (250 mm probe, max.150°C)<br />
HygroClip HK40 (400 mm probe, max. 200°C)<br />
Ø: 15 mm Probe length: 250 mm/400 mm Cable: 2 m
HygroClip SP05<br />
Fast response 5 mm diameter insertion probe with laser cut air slots<br />
for bulk goods such as corn, wheat, & granules. Also suitable for<br />
measurements in concrete and brick. Not suitable for powders.<br />
Probe length 200 mm.<br />
Measurement range: -40…85°C , 0…100 %rh,<br />
Accuracy: ±1.5 %rh , ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip SP05<br />
Ø: 5 mm Probe length: 200 mm Cable: 2 m<br />
HygroClip HP28<br />
Robust 10 mm diameter tubular probe for measurements in bulk<br />
products such as powders & granules.<br />
Probe length 280 mm, 2m cable, steel sinter fi lter.<br />
Measurement range: -40…85°C, 0…100 %rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip HP28<br />
Ø: 10 mm Probe length: 280 mm Cable: 2 m<br />
HygroClip HS28 Sword Probe<br />
For measurements in paper stacks/rolls. Lightweight, yet robust<br />
aluminium blade for fast temperature and humidity equilibrium.<br />
Blade 280 x 18 x 4 mm.<br />
Measuring range: -40…85°C, 0… 100 %rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip HS28<br />
Sword length: 280 mm Cable: 2 m<br />
HygroClip Probes for HygroPalm<br />
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
9
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
10<br />
Handheld Sets and Accessories<br />
Measuring instruments often need to be transported around site, and in some cases from building to<br />
building. We have created a series of handheld measurement sets which securely contain most commonly<br />
used standard equipment and accessories. Carry cases are also useful for storing instruments when not<br />
in use, and help to maintain long-term stability by protecting the units from climatic variations or contamination<br />
in storage conditions.<br />
HygroPalm 1 Set<br />
Consists of:<br />
• HygroPalm 1 Handheld Instrument<br />
• HygroClip-S probe<br />
• Calibration device ER15, fi tting for HygroClip-S<br />
• Humidity standards 50 %rh EA50-SCS<br />
• Robust carrying case AC1116<br />
Order code:<br />
HygroPalm 1-Set<br />
HygroPalm 2-Set-HS28<br />
Consists of:<br />
• HygroPalm 2 Handheld Instrument<br />
• HygroClip-HS28 probe<br />
• Calibration device EGS, fi tting for HygroClip-HS28<br />
• Humidity standards 50 %rh EA50-SCS<br />
• Robust carrying case AC1117<br />
• Software HW3<br />
• Connection Cable<br />
Order code:<br />
HygroPalm 2-Set-HS28<br />
HygroPalm 3-Set-PC<br />
Consists of:<br />
• HygroPalm 3 Handheld Instrument<br />
• HygroClip S probe<br />
• Calibration device ER15, fi tting for HygroClip-S<br />
• Humidity standards 50 %rh EA50-SCS<br />
• Robust carrying case AC1116<br />
• Software HW3<br />
• Connection Cable AC1622<br />
Order code:<br />
HygroPalm 3-Set-PC<br />
Temperature adaptor for Pt100 probes<br />
The HygroPalm can also handle Pt100 probes with standard Binder<br />
connector, see page 89 for a range of compatible Pt100 probes.<br />
Order code:<br />
HygroClip-TH100-B5<br />
Windspeed probe Mini Air6 Micro<br />
Mini Air 6 can be connected to HygroPalm 2 & 3 types<br />
as well as to data loggers and industrial transmitters.<br />
Measuring range: 0.5 – 20 m/s<br />
Temperature range: -10…80°C<br />
Output signal: 0 – 2.0 V<br />
Head-Size: Ø11 x 15 x 165 mm<br />
Cable length: 5 m<br />
Order code:<br />
MiniAir6 Micro 20M/s<br />
Other windspeed probes available on request<br />
Suitable for:<br />
HVAC technicians, supervisors<br />
Suitable for:<br />
Paper processing industry, any<br />
user of cut-sheet material<br />
Suitable for:<br />
Users who want to record<br />
measured values on a PC and<br />
calibrate their probes.
GTS and GTS-Set<br />
The GTS is a classic ROTRONIC product which has stood the test on time.<br />
It was designed specifi cally for the measurement of humidity and temperature within stacks of paper,<br />
cardboard or any other cut-sheet material.<br />
The robust design in combination with updated electronics make the GTS the most popular instrument<br />
for paper and card applications.<br />
GTS – for paper and cardboard stacks<br />
• Display of relative humidity or temperature<br />
• Simple one button operation<br />
• Auto power off function<br />
• Low-battery indicator<br />
Order code:<br />
GTS<br />
GTS – Set-Measurement set for cut-sheet material<br />
includes:<br />
GTS instrument<br />
Robust carrying case<br />
Calibration device EGS<br />
Humidity standards EA50-SCS<br />
(5 ampoules 50 %rh with SCS certifi cate)<br />
Adjustment tool<br />
Order code:<br />
GTS-Set<br />
Carrying case for GTS, without instrument<br />
Order code:<br />
AC1102 Case (without accessories)<br />
A1 for air measurement<br />
Another classic design which we retain thanks to continuing demand<br />
from our customers.<br />
• Reference probe for relative humidity and temperature<br />
• Integrated climate probe with adjustable position<br />
• Large, clear display<br />
• Simple operation<br />
• Hold function<br />
• Auto power off<br />
• Battery status indicator<br />
• Battery or accumulator operation<br />
• Temperature Display in °C or °F<br />
Order code:<br />
A1<br />
Accessories for the A1<br />
• Robust and handy carry case for A1 instruments plus accessories.<br />
• Calibration device EGL (see page 98)<br />
• Calibration standards (see page 97)<br />
Order code:<br />
AC1115 Case (without accessories)<br />
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
11
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
12<br />
Technical Data Summary<br />
Features HygroPalm 1 HygroPalm 2 HygroPalm 3 A1 GTS<br />
Humidity sensor Hygromer ® HygroClip-S probes with Hygromer ® AC-1 Sensor AC-1<br />
Temperature sensor Pt100 1/3 DIN Pt100 B<br />
Probe connections (combined %rh/°C) 1 2 Integrated probe<br />
Signal input<br />
1 digital 2 digital<br />
2 digital or<br />
4 analogue<br />
Third party probe input No 0…2.5 V<br />
Supply for 3 rd party probe No 9 V / 10 mA No<br />
RS232 Interface No Yes No<br />
Display Humidity<br />
3-digit LCD 3-digit LCD<br />
3-line alphanumeric LCD<br />
Temperature 3 1⁄2 digit LCD (%rh or ° C)<br />
Display units %rh, °C, °F, calculated param. Freely select. %rh, °C, °F %rh, °C, °F<br />
Resolution 0.1%rh/ 0.1°C 0.1%rh/0.1°C 0.1%rh/0.1°C<br />
Probe adjustment<br />
1 point %rh, °C By Keypad By potentiometer<br />
4-point %rh, 2 point °C No By Keypad and Software No<br />
3-point %rh, T min./Tmax. N/A 35 / 80 / 10 % No<br />
2-point %rh, Tmin / Tmax N/A 35 / 80%<br />
Calculation & unit display<br />
Dew-point and wet bulb temperature Yes No<br />
Full psychrometric calculation No Yes No<br />
Pressure compensation No manually dynamically<br />
of calculated values adjustment with Software with pressure No<br />
probe input<br />
Humidity displayed in Aw units No Yes No<br />
Formula Editor No Yes No<br />
Remote Transmitter Control<br />
Transmitter adjustment No Yes No<br />
Transmitter adjustment<br />
against reference probe<br />
No Yes No<br />
Transmitter measurement display Yes No<br />
Transmitter status display No Yes No<br />
Operating ranges of electronics<br />
Humidity/Temperature<br />
Measuring ranges<br />
Measuring ranges (probes)<br />
Accuracy at 23 °C<br />
0…100 %rh, non condensing / -10…60°C<br />
Probe dependent 0…100 %rh / -50…200°C<br />
±1.5 %rh/ ±0.3 K<br />
Reproducibility < 0.5 %rh / < 0.1 K<br />
Long Term Stability < 1 %rh / Year<br />
Power Supply<br />
9 V PP3 alkaline battery Yes<br />
0…100 %rh<br />
-10…50°C<br />
5…99.9 %rh / 5…99.9 %rh<br />
-25…75°C -10…50°C<br />
±1.5 %rh / (±2.5 90%)<br />
±0.3 K<br />
9V Accumulator Yes No Yes<br />
230 V External supply voltage Optional, only with Docking Station No<br />
Type of enclosure / IP Rating IP 50<br />
Housing material ABS<br />
Dimensions in mm 295 x 70 x 35 190 x 63 x 26 420 x 70 x 40<br />
Weight ca. 200 g ca. 170 g ca. 400 g
GTS<br />
A1<br />
62.8<br />
27<br />
HygroPalm<br />
57<br />
150<br />
~40<br />
RH<br />
°C<br />
65<br />
191 167<br />
A1<br />
Dimensional Diagrams<br />
40<br />
18<br />
260<br />
5<br />
ø10<br />
H<br />
A<br />
N<br />
D<br />
H<br />
E<br />
L<br />
D<br />
I<br />
N<br />
S<br />
T<br />
R<br />
U<br />
M<br />
E<br />
N<br />
T<br />
S<br />
13
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
14<br />
Dataloggers<br />
Long term recording of humidity and temperature measurements is essential in many production, storage,<br />
transportation, display and test applications. They provide valuable information on the levels and variation<br />
of humidity and temperature which can have a signifi cant impact on people, materials and objects.<br />
The ROTRONIC range of data loggers and recorders are highly accurate and stable, but are easy to use<br />
and maintain. Confi guration and programming can easily be performed by any operator, with user-friendly<br />
software or integrated keypads. Data can be presented in a graphical or statistical format. A wide range of<br />
interchangeable probes means simple maintenance and application fl exibility.<br />
Key features<br />
• Compact stand alone modules<br />
• Measurement display<br />
• Accuracy and Long Term Stability<br />
• Interchangeable sensor module<br />
• Wide range of probes<br />
• Robust IP65 housing with shock protection<br />
• Battery powered<br />
• Custom mounting hardware<br />
• Large memory<br />
• User-friendly Software<br />
• Validated software FDA CFR 21 part 11<br />
Your benefi ts<br />
� Easy to install and fl exible<br />
� Easy observation of current values & alarms<br />
� Reliable data and reduced maintenance<br />
� Easy calibration & maintenance<br />
� One logger – many applications<br />
� Suitable for industrial use.<br />
� No installation costs and can be easily relocated<br />
� Professional installation<br />
� Long term recording up to one year<br />
� Easy to learn and use<br />
� High quality assurance<br />
Section contents Page<br />
HygroLog and HygroLog D Data logger for<br />
HygroClip probes 16 to 17<br />
� Interchangeable probes<br />
� Integrated display<br />
� Alarm function<br />
� Validated, easy-to-use software<br />
HygroClip probes for HygroLog Data logger 18 to 19<br />
� Wide range of options to suit any application<br />
� 0…100 %rh, -50…200 °C<br />
� 100 % interchangeable without adjustment<br />
Agent D Data logger for humidity and temperature 20 to 23<br />
� 64000 point memory<br />
� Multi channel temperature only versions<br />
� EX rated<br />
� External start feature<br />
Accessories for HygroLog and Agent D 24 to 25<br />
� Installation hardware<br />
� Impact protection<br />
� Connecting cables<br />
� Power supplies
Store rooms and warehouses<br />
Production areas<br />
Datalogger Applications<br />
Museums, libraries & art galleries<br />
Transportation<br />
Clean rooms<br />
Controlled environments &<br />
cabinets<br />
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
15
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
16<br />
HygroLog and HygroLog D<br />
Humidity and Temperature logger for digital HygroClip ® probes.<br />
The HygroLog data logger uses the HygroClip range of digital probes for long term recording of humidity<br />
and temperature conditions. By using the digital signal output from the HygroClip probes, measurement<br />
precision is optimised with no signal loss over extended cable lengths and no external interference can<br />
infl uence measured values. Calibration data is maintained within the probe, which means there is no need<br />
to calibrate the whole system, and probes can be interchanged in seconds. In conjunction with the HW3<br />
software, the HygroLog can be supplied with full validation documentation.<br />
HygroLog<br />
Self contained data logger for HygroClip ® digital probes<br />
Key features:<br />
• Stores up to 2 x 5000 values for humidity and temperature<br />
• Digital signal processing for maximum accuracy<br />
• Logging interval from 15 seconds to 2 hours<br />
• Standard alkaline batteries used<br />
• Operating modes selectable: Start/stop or loop mode<br />
• Operating range Logger: 0…100 %rh; -30 …70°C<br />
(Battery-dependent; with alkaline batteries –10…50°C)<br />
• Measuring range Probes: -50…200°C, probe dependent<br />
Order code:<br />
HygroLog (probe must be ordered separately)<br />
HygroLog D<br />
Humidity and Temperature data logger with LCD display for<br />
HygroClip ® digital probes<br />
Key features:<br />
• Stores up to 2 x 5000 values for humidity and temperature<br />
• Digital signal processing for maximum accuracy<br />
• Logging interval from 15 seconds to 2 hours<br />
• Standard alkaline batteries used<br />
• Operating modes selectable: Start/stop or loop mode<br />
• Operating range Logger: 0…100 %rh; -10 …50°C<br />
(Battery-dependent; with alkaline batteries –10…50°C)<br />
• Operating range -50…200°C (probe dependent)<br />
• Visual alarm indicators on LCD for temperature & humidity<br />
• Battery status display<br />
• Status display saving / busy<br />
Order code:<br />
HygroLog-D (probe must be ordered separately)<br />
Software HW3 and Data Cable (FDA CFR 21 Part 11)<br />
The validated multilingual software HW3 is used for programming the<br />
loggers as well as to retrieve data. Data may be displayed in a table or<br />
graph form. A language editor gives the user the possibility to translate<br />
the text into his own language. Psychrometric calculations such as<br />
dewpoint may also be performed within the software, and the option<br />
to show these values on the graphic is also included. Calculations may<br />
be executed by using a pressure constant or, depending on the instruments<br />
connected, dynamically with a pressure probe. As the software<br />
can also be used with the full ROTRONIC product range, it offers a variety<br />
of other features, such as sending e-mails in case of alarms, data<br />
archiving, etc. Of course, measurement data can also be exported to<br />
MS Offi ce applications.<br />
For extended description see section HW3 software.<br />
Order code:<br />
HygroData HL
Feature Overview<br />
Highly precise and stable humi -<br />
dity and temperature sensors<br />
HygroLog<br />
Interchangeable probes<br />
Calibration can be updated,<br />
or the range of application<br />
changed by the simple<br />
connection of a different<br />
probe. See next page for<br />
available options. 10000 point<br />
integrated memory<br />
Connection socket for probe<br />
or PC interface cable<br />
Wall mounting bracket with option<br />
to connect mains power adapter<br />
Robust IP65 enclosure<br />
Integrated LC display<br />
Includes battery status<br />
and alarm indicators<br />
Programmable<br />
measurement interval<br />
15 seconds to 2 hours<br />
User replaceable batteries<br />
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
17
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
18<br />
HygroClip probes for HygroLog Datalogger<br />
A range of probes for different applications are available for the HygroLog Dataloggers. All probes<br />
are based on the digital HygroClip technology, and can be interchanged within seconds without need<br />
for recalibration. With special adaptor cables, even probes designed for transmitters may be used.<br />
HygroClip S/S1<br />
Standard sensor module for humidity and temperature. A wire mesh<br />
fi lter provides sensor protection against dust and high air velocity.<br />
Dimensions Ø15 x 100 mm. IP rating: IP65<br />
HygroClip S1 is a specially calibrated and certifi ed to provide<br />
measurement accuracy of ±1%rh.<br />
Measurement range: -40…85°C, 0…100%rh<br />
Accuracy (S1): ±1.0 %rh, ±0.2 K (at 23°C)<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip S1<br />
HygroClip S<br />
Ø: 15 mm Length: 100 mm<br />
HygroClip SC04 / SC05<br />
4/5 mm cable probe for humidity and temperature measurements in<br />
small spaces such as product & packaging testing, concrete, electronic<br />
test and climatic chambers.<br />
Cable length 2m<br />
Measurement range: -40…100°C, 0…100%rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip SC04 4 mmØ probe<br />
HygroClip SC05 5 mmØ probe<br />
Ø: 4/5 mm Cable: 2 m<br />
HygroClip HK 25 /HK40<br />
High temperature probe for measurements in ducts, dryers, climatic<br />
chambers etc. Probe length 250 or 400 mm. Wire mesh fi lter included.<br />
Measurement range: HK25: -50…150°C, 0…100%rh<br />
HK40: -50…200°C, 0…100%rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip HK25 (250 mm, max.150°C)<br />
HygroClip HK40 (400 mm, max. 200°C)<br />
Ø: 15 mm Probe length: 250 mm/400 mm Cable: 2 m
HygroClip SP05<br />
HygroClip Probes for HygroLog Datalogger<br />
Fast response 5 mm diameter insertion probe with laser cut air slots<br />
for bulk goods such as corn, wheat, & granules. Also suitable for<br />
measurements in concrete and brick. Not suitable for powders.<br />
Probe length 200 mm<br />
Measurement range: -40…85°C , 0…100 %rh,<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip SP05<br />
Ø: 5 mm Probe length: 200 mm Cable: 2 m<br />
HygroClip HP28<br />
Robust 10mm diameter tubular probe for measurements in bulk<br />
products such as powders & granules. Probe length 280 mm,<br />
2m cable, steel sinter fi lter.<br />
Measurement range: -40…85°C, 0…100%rh<br />
Accuracy: ±1.5%rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip HP28<br />
Ø: 10 mm Probe length: 280 mm Cable: 2 m<br />
HygroClip HS28 Sword Probe<br />
For measurements in paper stacks/rolls. Lightweight, yet robust aluminium<br />
blade for fast temperature and humidity equilibrium.<br />
Blade 280 x 18 x 4 mm.<br />
Measuring range: -40…85°C, 0… 100 %rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip HS28<br />
Sword length: 280 mm Cable: 2 m<br />
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
19
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
20<br />
Agent-D Series<br />
Agent-D Series Humidity and temperature logger<br />
The Agent-D series is a versatile family of data-loggers with integrated LC display for the<br />
measurement of humidity and temperature with both integrated and cable mounted sensors.<br />
Measurement ranges and logging interval can be confi gured with easy-to-use Windows software,<br />
or via the integrated keypad. A special version is available for hazardous areas (Zone 1). All versions<br />
feature a 64000 point memory, user replaceable batteries and the operating range of the<br />
logger is -35…55°C / 0…100 %rh. Measurement range depends on the probe confi guration. (see<br />
Probes for Agent-D-NT & PT Series)<br />
Agent-D-HT2<br />
2-channel humidity and temperature logger<br />
• Integrated probe for temperature / humidity Agent-D-Clip-S<br />
• Optional remote probe for humidity and temperature<br />
• Measuring range with:<br />
– integrated probe: -35…55°C / 0…100 %rh<br />
– remote probe: -35…70°C / 0…100 %rh<br />
– high temp. remote probe: -35…110°C / 0…100%rh<br />
• Single digital input for monitoring doors etc (switch status)<br />
Order code:<br />
Agent-D-HT2 included probe Agent-D-Clip-S<br />
Agent-D-HT2-EX (for EX-Zone 1) included probe Agent-D-Clip-S<br />
Agent-D-NT3<br />
3-channel temperature logger with NTC probes<br />
• 1 integrated NTC temperature sensor<br />
• 2 external NTC probes connected by D-sub-15 plug<br />
• Measuring range: -50…140°C<br />
Order code:<br />
Agent-D-NT3<br />
Agent-D-NT3-EX (for EX-Zone 1)<br />
Agent-D-PT4<br />
4 channel temperature logger for Pt100 probes<br />
• Integrated keypad<br />
• Pt100 probe 4 wire connection, Lemo or D-sub connector<br />
• Measuring range: -200…550°C<br />
• Single digital input for monitoring doors etc (switch status)<br />
Order code:<br />
Agent-D-PT4<br />
Probe must be ordered separately, see page 22.
Feature Overview<br />
Digital display for measured<br />
value, date, time and alarm<br />
(displayable down to –20°C)<br />
Alarm-reset,<br />
measuring values and<br />
alarm scroll via keypad<br />
Results may be<br />
printed directly<br />
without a PC<br />
External start<br />
(devices without keypad only),<br />
Agent-D Series<br />
Display test<br />
Memory for 64,000<br />
measurement values<br />
Choice of sensors:<br />
Humidity/temperature<br />
combined<br />
or Temperature<br />
only see page 22 and 23<br />
Replaceable, commercially available<br />
batteries<br />
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
21
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
22<br />
Probes for Agent-D-NT & PT Series<br />
Agent-D-HT2 Probes<br />
Combined standard probe for temperature & humidity<br />
Measuring range: –35…70°C / 0…100 %rh<br />
High temperature probe: –35…110°C<br />
Refurbished (standard) probe<br />
Order code:<br />
Agent-D-Clip S Standard probe<br />
Agent-D-Clip H High temperature probe Agent-D-Clip H<br />
(with Agent-D-D12 only)<br />
Agent-D-Clip R Refurbished standard probe<br />
Temperature probe Specifi cation Probe Order code<br />
1 probe 1 probe 2 probe<br />
Lemo Plug D-sub Plug D-sub Plug<br />
Universal probe -50...140°C<br />
Cable length: 2 m NTC AC3010-NL AC3010-ND1 AC3010-ND2<br />
T max. Cable: 140°C<br />
-80...260°C<br />
Cable length: 4 m Pt100 AC3163-PL<br />
T max. Cable: 140°C<br />
Miniature bead probe -50...140°C<br />
Cable length: 2 m NTC AC3055-NL AC3055-ND1 AC3055-ND2<br />
T max. Cable: 140°C<br />
Surface probe<br />
Plug-in probe<br />
Robust universal probe<br />
Flexible universal probe<br />
High temperature probe<br />
Agent-D Probes<br />
-50...140°C<br />
Cable length: 2 m NTC AC3041-NL AC3041-ND1<br />
T max. Cable: 140°C<br />
-35...55°C NTC AC3060-NL<br />
Pt100 AC3160-PL<br />
-50...140°C<br />
Cable length: 10 m NTC AC3090-NL<br />
T max. Cable: 140°C<br />
-200...350°C<br />
Cable length: 5 m Pt100 AC3165-PL<br />
T max. Cable: 140°C<br />
-80...500°C<br />
Cable length: 4 m Pt100 AC3162 - PL<br />
T max. Cable: 250°C
Agent-D Series<br />
Agent-D-HT2<br />
8 1 5<br />
1<br />
9<br />
Agent-D-PT4<br />
8 1 5<br />
1<br />
9<br />
Agent-D-NT4<br />
8 1 5<br />
1<br />
9<br />
Agent-D-NT3<br />
8 1 5<br />
1<br />
9<br />
8 GND 15 RxD<br />
7 TxD 14 Busy<br />
6 + Ref. 13 NTC1<br />
5 A1 12 NTC2<br />
4 A2 11 D1, 2<br />
3 B1 10 DigitIn<br />
2 B2 9 Alarm<br />
1 C1, 2<br />
8 GND 15 RxD<br />
7 TxD 14 Busy<br />
6 Ubat 13 A2<br />
5 A1 12 A2<br />
4 A1 11 B 2<br />
3 B1 10 DigitIn<br />
2 B1 9 Alarm<br />
1 B2<br />
8 GND 15 RxD<br />
7 TxD 14 Busy<br />
6 NTC2 13 Res.<br />
5 +Ref 12 DigitIn1<br />
4 NTC4 11 Ubat<br />
3 NTC3 10 DigitIn2<br />
2 +Ref 9 Alarm<br />
1 NTC1<br />
8 GND 15 RxD<br />
7 TxD 14 Busy<br />
6 NTC2 13 Res.<br />
5 +Ref 12 Start/<br />
Inpos<br />
4 Res 11 Ubat<br />
3 NTC3 10 Alarm<br />
Reset<br />
2 +Ref 9 Alarm<br />
1 NTC1<br />
NTC<br />
+Ref<br />
A<br />
B<br />
C<br />
D<br />
GND<br />
+Ref<br />
DigitIn<br />
Alarm +<br />
GND<br />
PTA<br />
PTA<br />
PTB<br />
PTB<br />
Ubat<br />
DigitIn<br />
Alarm +<br />
GND<br />
NTC<br />
+Ref<br />
UBat<br />
DigitIn<br />
Alarm +<br />
GND<br />
NTC<br />
+Ref<br />
UBat<br />
Start/Inpos<br />
Ubat<br />
Alarm Reset<br />
0…50VDC, max. 200mA<br />
0…50VDC, max. 200mA<br />
0…50VDC, max. 200mA<br />
Schematics<br />
Electrical connections Electrical diagrams Dimensional diagrams<br />
A B<br />
A<br />
B<br />
8 4<br />
3 4<br />
LEMO connector<br />
(View from the<br />
solder side)<br />
8 4<br />
3 4<br />
8 4<br />
3 4<br />
8 4<br />
3 4<br />
1 1 1 . 5<br />
Keyboard<br />
F 1 F 2 F 3<br />
5 8<br />
Replaceable humidity and<br />
temperature sensor module<br />
1 1 1 . 5 3 4<br />
F 1 F 2 F 3<br />
5 8<br />
1 1 1 . 5 3 4<br />
F 1 F 2 F 3<br />
5 8<br />
NTC sensor integrated in logger housing<br />
1 1 1 . 5 3 4<br />
5 8<br />
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
23
D<br />
A<br />
T<br />
A<br />
L<br />
O<br />
G<br />
G<br />
E<br />
R<br />
S<br />
24<br />
Accessories<br />
For HygroLog<br />
Wall Mounting Bracket and Anti Theft Device<br />
Wall mounting bracket with integrated power supply connector, suitable<br />
for AC1207 adaptor. May be combined with Anti Theft Device<br />
AC1005.<br />
The HygroLog-IPH is fi xed on a fl at surface together with the securing<br />
plate by two screws. A steel rod with a padlock secures the logger in<br />
place. (Delivered without padlock)<br />
Order code:<br />
HygroLog-IPH Wall mounting bracket<br />
AC1207 AC Adaptor<br />
AC1005 Anti Theft Device<br />
Extension Cables and Adaptors<br />
For applications in high temperatures or in ducts, etc. where the logger<br />
housing may not be located in directly. Available in 2 lengths:<br />
Order code:<br />
MOK-01-DAT05 1m<br />
MOK-02-DAT05 2m<br />
12.02.1086 USB Adapter<br />
T7-03-DAT05 Adaptor for industrial probes<br />
Impact Protection HygroLog-SP<br />
The impact protection HygroLog-SP may be a welcome accessory<br />
in cases where the logger is exposed to shocks, vibrations and harsh<br />
environmental conditions. It protects the logger, thus saving you<br />
money in the long run.<br />
Order code:<br />
HygroLog-SP<br />
For Agent-Series<br />
Protocol Printer<br />
Thermo printer with serial interface for print-outs of the logged data<br />
Order Code:<br />
Agent-D-Print Printer<br />
Agent-D-DataP Data cable printer<br />
Agent-D-Data Data cable PC/Logger<br />
Probe Cables<br />
Extension cable for 1 or 2 Agent-D-Clip probes Agent D-HT2,<br />
for D-Sub connector. Lengths: 2 and 5 m<br />
Order code:<br />
Agent-D-D12 2 m / 1 Probe<br />
Agent-D-D22 2 m / 2 Probes<br />
Agent-D-D15 5 m / 1 Probe<br />
Agent-D-D25 5 m / 2 Probes<br />
Various<br />
Order code:<br />
Agent-D-SW Application Software multilingual<br />
Agent-D-SW-UP Software Update<br />
Agent-D-IPH Mounting bracket<br />
Agent-D-IPH-L Mounting bracket lockable<br />
Agent-D-AL Connector plug with screw terminals<br />
Agent-D-Bat Lithium battery for Agent-D
Series HygroLog HygroLog D Agent-D-HT2 Agent-D-NT3 Agent-D-PT4<br />
Humidity sensor HygroClip-S probe C 94 N/A N/A<br />
Temperature sensor with HYGROMER ® AC-1 NTC NTC Pt100<br />
Pt100 1/3 DIN<br />
Operating ranges<br />
Humidity 0…100 %rh 0...100 %rh<br />
Temperature - 35...55 °C<br />
- with alkaline battery -10...50°C<br />
- with special batteries -30...70°C -10...50°C<br />
Measuring ranges<br />
Humidity = Operating range of probe 0...100 %rh N/A<br />
Temperature = Operating range of probe -50...140°C -200...550°C<br />
Accuracy at 23°C ±1.5 %rh / ±0.3 K<br />
Output signal RS232<br />
Reproducibility < 0.5 %rh /
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
26<br />
Transmitters<br />
ROTRONIC humidity and temperature transmitters are world renowned for their excellent precision, longterm<br />
stability and reliability. Today our transmitter range offers an unparalleled range of innovative features<br />
to compliment the core ROTRONIC abilities of accuracy, reliability and long term stability.<br />
Transmitters are measuring instruments for fi xed installation with a specifi c signal output; primarily made<br />
for process applications and control. In climate control applications, ROTRONIC transmitters are used to<br />
optimise energy use and create a comfortable environment. Key features are accuracy, long term stability,<br />
time/cost saving installation, and low cost maintenance; they will easily outperform the low cost products<br />
typically used in commercial BMS/HVAC systems.<br />
Typical applications include building management systems, offi ce buildings, storage areas, clean rooms,<br />
hospitals, computer rooms, telecommunications centres.<br />
ROTRONIC industrial transmitters are robust – high quality products designed specifi cally for demanding<br />
commercial and industrial applications. They tolerate exposure to wide temperature variation, condensation<br />
and high levels of chemical pollution thanks to the unique properties of the Hygromer ® humidity sensor,<br />
which ensures excellent long-term stability in the most demanding applications. The highest precision<br />
over a wide operating range is achieved with dynamic temperature compensation (-50…200°C).<br />
The new generation of HygroClip industrial transmitters is based on the latest digital fl ash technology so<br />
probes can be interchanged with no effect on system accuracy. The modular probe concept means on-site<br />
calibration and maintenance is virtually eliminated. State of the art features also include calculation of a<br />
wide range of humidity parameters, user programmable scaling of output signals and networkable digital<br />
communications.<br />
Typical applications include process monitoring and optimisation, test cells, drying processes up to 200°C,<br />
climatic chambers, and high value product environments such as the pharmaceutical and semiconductor<br />
industries.<br />
Key features<br />
• Excellent long term stability
Power Stations<br />
Power generation, whether nuclear<br />
or fossil fuelled requires<br />
carefully controlled environments<br />
for best performance and<br />
reliability.<br />
Drying processes.<br />
Monitoring and control of any industrial<br />
drying process can have<br />
signifi cant benefi ts in terms of<br />
product quality, energy use and<br />
productivity.<br />
Environmental Test.<br />
Every product from mobile<br />
telephones to a car is today<br />
subjected to thorough climatic<br />
test conditions to establish and<br />
maintain reliability. Humidity<br />
and temperature conditions are a<br />
critical part of this process.<br />
Transmitter Applications<br />
High temperature.<br />
HygroFlex offers the highest direct<br />
humidity measurement currently<br />
available.<br />
Ceramics Industry.<br />
The measurement and control of<br />
the drying processes in the ceramics<br />
industry.<br />
Intrinsically safe.<br />
In combination with the<br />
HygroClip EX, the HygroFlex can<br />
be used to measure humidity<br />
and temperature in the most<br />
hazardous zone 0.<br />
Hazardous storage areas<br />
Explosive materials such<br />
as weapons or chemicals<br />
also need to be kept at the correct<br />
humidity and temperature<br />
conditions.<br />
Paper Industry<br />
Monitoring and control of the<br />
drying process.<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
27
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
28<br />
The Digital Advantage<br />
1. Measurement Accuracy:<br />
Digital processing of sensor signals provides much more scope and fl exibility for the compensation of error<br />
components such as linearity and temperature coeffi cients. ROTRONIC sensors have always been regarded<br />
as amongst the most precise and stable in the world; with this new technology, small errors become even<br />
smaller!<br />
2. Maintenance and Calibration:<br />
Digital signal communication allows components to be ‘hot swapped’ without loss of measurement precision<br />
– calibration and sensor data are retained permanently within each digital HygroClip probe.<br />
HygroClip probes can be ‘hot swapped’ in seconds, signifi cantly reducing the maintenance and downtime<br />
costs associated with the removal of instruments to laboratories or workshops for diffi cult, time-consuming<br />
calibration and repair. HygroFlex can also be fi eld calibrated and adjusted directly using the HygroPalm 3<br />
calibrator.<br />
3. Precision and Stability:<br />
Digital circuits are inherently more stable than analogue, and are less affected by temperature changes.<br />
Calibration adjustment is made purely by software, meaning no unstable, hard-to-reach potentiometers.<br />
The option for multiple calibration points is extended across the full measurement range.<br />
4. Application Flexibility:<br />
HygroFlex<br />
HygroFlex is a new generation of industrial humidity and temperature transmitters based on the very latest<br />
digital technology. Digital signal processing signifi cantly benefi ts humidity and temperature measurement<br />
in fi ve key areas:<br />
Measurement change? Need dew-point instead of %rh? Or the mixing ratio ? Simply connect the HygroFlex<br />
to a PC and change the confi guration!<br />
Different installation? If your application needs change, simply fi t one of the wide range of probes with an<br />
alternative confi guration or temperature operating range.<br />
Multiple point measurement? Need to expand? The HW3 software package offers a comprehensive networking<br />
solution for up to 32 instruments. HW3 features data logging (reporting), graphical and alarm functions<br />
and operates on any standard Windows based PC.<br />
Wiring hardly possible? Or too expensive? The HygroFlex is able to communicate by means of a radio controlled<br />
interface option.<br />
5. Measurement of Dew Point and other Parameters:<br />
Digital technology makes it possible to obtain parameters such as dew point or the mixing ratio with economical,<br />
versatile and easy-to-maintain instruments and probes. Taking the chilled mirror technology as an<br />
example, typical requirements and problems are eliminated: no sampling system is required in most applications,<br />
there is no longer any uncertainty between dew and frost, and the requirement for frequent mirror<br />
cleaning fully disappears.
Core features<br />
High quality electronics<br />
High quality, high stability electronics<br />
ensure consistent long<br />
term performance<br />
High temperature capability<br />
ROTRONIC transmitters<br />
have the widest direct<br />
humidity measurement<br />
range in the world working<br />
from –50…200°C.<br />
High quality sensor<br />
The Hygromer ® IN-1 humidity<br />
sensor is arguably the best in<br />
the world. Precise factory adjustment<br />
and superb long term stability<br />
provide consistent measurement<br />
results with minimum<br />
maintenance.<br />
HygroFlex<br />
Temperature compensated<br />
All ROTRONIC transmitters are<br />
dynamically temperature compensated<br />
to maintain best possible<br />
humidity measurement accuracy<br />
over very wide temperature<br />
ranges.<br />
Interchangeable probes.<br />
Across the entire ROTRONIC<br />
transmitter range it is possible<br />
to specify interchangeable<br />
probes; simplifying fi eld<br />
maintenance and maximising<br />
application fl exibility.<br />
User calibration<br />
All ROTRONIC transmitters can<br />
be adjusted by the user to provide<br />
optimum precision throughout<br />
the product’s life without<br />
expensive ‘return to base’ maintenance.<br />
Digital technology<br />
Digital signal processing not<br />
only provides the best possible<br />
precision, but also allows fully<br />
digital adjustment for all industrial<br />
HygroClip probes.<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
29
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
30<br />
Key features:<br />
• %rh and temperature<br />
• Interchangeable probes<br />
• Two linear analogue outputs<br />
• Jumper confi guration of<br />
analogue outputs<br />
• One probe input, digital or<br />
analogue (0…2.5 V, 10 Bit A/D;<br />
12 Bit interpolated)<br />
• Optional display/keypad<br />
HygroFlex 1<br />
Analogue outputs<br />
HygroFlex 1 accepts one HygroClip probe and provides two linear<br />
analogue outputs for relative humidity and temperature. Standard<br />
factory confi guration is 4…20 mA, but this can be easily changed to<br />
0…20 mA, 0…1 V, 0…5 V or 10 V. Scaling of the output range can be<br />
modifi ed from the standard 0…100%rh and 0…100°C using the internal<br />
service connection, connecting cable AC1623 and a PC running<br />
the HW3 software.<br />
An external test socket is standard. A HygroPalm 3 handheld instrument<br />
can be connected to provide a live display of the transmitters<br />
current measurement values. When connected, the HygroPalm 3 can<br />
also be used as a digital adjustment tool for any probe connected to<br />
the HygroFlex 1.<br />
The optional display & keypad gives a local display of measurement<br />
values and provides access to the 1 or 4 point probe adjustment directly<br />
from the HygroFlex 1 transmitter.<br />
For probe options, see page 34 to 35.<br />
HygroFlex 1 Ordering Information for Standard Versions<br />
H T S 1 1 X HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 12…35 VDC/24 VAC power<br />
H T S 1 2 X HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 90...250 VAC power<br />
H T S 1 1 D HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 12…35 VDC/24 VAC power;<br />
Display & Keypad<br />
H T S 1 2 D HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 90...250 VAC power;<br />
Display & Keypad<br />
(see page 33 for order codes for special versions)<br />
HygroFlex 1 Standard Connection Layout<br />
Probe (Tuchel) Test socket<br />
(Binder 712, 2-pin)<br />
2x M16 Cable glands for<br />
power and signal cables
Digital output, two Probes and Calculation function<br />
HygroFlex 2<br />
HygroFlex 2 measures and transmits humidity and temperature measurements only in a digital format. The<br />
data is either output in an RS232 signal directly to a PC, or up to 32 transmitters can be networked together<br />
using RS485 for network communication, with RS232 used for PC connection. HygroFlex 2 is also supplied<br />
as standard with the capability to accept a second probe input and has integrated psychrometric calculation<br />
for parameters such as dew-point or mixing ratio. Thanks to the possibility to accept 2 probes, it is possible<br />
to set up a network with up to 64 probes = 128 measuring values at a very reasonable price. Probe- cables of<br />
up to 200m cover all applications. Standard features also include full user programmability and an external<br />
test socket.<br />
An external test socket is standard. A HygroPalm handheld instrument<br />
can be connected to provide a live display of the transmitters current<br />
measurement values. When connected, the HygroPalm can also<br />
be used as a digital adjustment tool for any probe connected to the<br />
HygroFlex.<br />
The optional display & keypad gives a local display of measurement<br />
values and provides access to the 1 or 4 point probe adjustment<br />
directly from the HygroFlex 2 transmitter.<br />
HygroFlex 2 Ordering Information for Standard Versions<br />
Key features:<br />
H T S 2 1 X HygroFlex 2; digital output only; 12…35 VDC/24 VAC power; 2 probe inputs<br />
H T S 2 2 X HygroFlex 2; digital output only; 90...250 VAC power; 2 probe inputs<br />
H T S 2 1 D HygroFlex 2; digital output only; 12…35 VDC/24 VAC power; 2 probe inputs;<br />
Display & Keypad<br />
H T S 2 2 D HygroFlex 2; digital output only; 90...250 VAC power; 2 probe inputs;<br />
Display & Keypad<br />
(see page 33 for order codes for special versions)<br />
HygroFlex 2 Standard Connection Layout<br />
Test socket<br />
(Binder 712, 2-pin)<br />
Probe 1 (Tuchel)<br />
Probe 2 (Tuchel)<br />
• %rh and temperature<br />
• Display of calculated values;<br />
dew-point, mixing ratio, etc<br />
(with keypad/display option)<br />
• RS232 output (%rh and temperature)<br />
• Networkable (RS485)<br />
• 2 nd probe input (digital or analogue<br />
0…2.5V e.g. pressure)<br />
• Fully user programmable<br />
Serial connection RS232/485<br />
(Binder 763/ 5-pin)<br />
Power connection<br />
(M16 cable gland)<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
31
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
32<br />
HygroFlex 3<br />
Simultaneous Analogue and Digital Outputs with Absolute Humidity Calculation<br />
HygroFlex 3 combines all the features of the HygroFlex 1 and 2 into a highly specifi ed instrument, and<br />
represents probably the most advanced humidity and temperature transmitter on the market. Additional<br />
features include a third analogue output for greater fl exibility, a simultaneous serial output and the ability<br />
to dynamically compensate calculated humidity parameters for variations in application pressure.<br />
The comprehensive range of outputs available makes the HygroFlex 3 particularly well suited to combined<br />
monitoring and control applications. The analogue outputs can be connected to the applications control<br />
system, whilst the digital RS232 signal interfaces with a local PC where engineers can monitor the process<br />
and set up alarms via Email or SMS text messages.<br />
The dynamic pressure compensation feature is truly state of the art. In climatic test or research and development<br />
projects, the humidity measurements can be optimised for any condition with the inclusion of<br />
pressure measurement, and therefore compensation of pressure dependent calculated values such as enthalpy<br />
and wet-bulb temperature. All calculated parameters are based on WMO formulae.<br />
Key features:<br />
• %rh, temperature and calculated<br />
value (dew-point, mixing<br />
ratio, etc)<br />
• Three linear analogue outputs<br />
(all measured and calculated<br />
parameters)<br />
• Jumper confi guration of analogue<br />
outputs<br />
• Simultaneous digital output<br />
(%rh and temperature)<br />
• Networkable (RS485)<br />
• 2 nd probe input (digital or analogue<br />
0…2.5V e.g. pressure)<br />
• Fully user programmable<br />
• External test socket<br />
• Optional display and keypad<br />
RS485<br />
RS485<br />
RS232<br />
An external test socket allows the connection of a HygroPalm 3 handheld,<br />
which will display the actual values of the transmitter. With the<br />
HygroPalm 3 it is also possible to adjust the digital ROTRONIC probes<br />
connected to transmitter.<br />
HygroFlex 3 Ordering Information for Standard Versions<br />
H T S 3 1 X HygroFlex 3; 4…20mA = 0…100 %rh; 0…100 °C/°C dew-point; 12…35 VDC/24 VAC power;<br />
2 probe inputs<br />
H T S 3 2 X HygroFlex 3; 4…20mA = 0…100 %rh; 0…100 °C/°C dew-point; 90...250 VAC power;<br />
2 probe inputs<br />
H T S 3 1 D HygroFlex 3; 4…20mA = 0…100 %rh; 0…100 °C/°C dew-point; 12…35 VDC/24 VAC power;<br />
2 probe inputs (1 optional); Display & Keypad<br />
H T S 3 2 D HygroFlex 3; 4…20mA = 0…100 %rh; 0…100 °C/°C dew-point; 90...250 VAC power;<br />
2 probe inputs (1 optional); Display & Keypad<br />
(see page 33 for order codes for special versions)<br />
HygroFlex 3 Standard Connection Layout<br />
Probe 1 Tuchel Power connection<br />
& analog output<br />
Test socket<br />
(Binder 712, 2 pin)<br />
Probe 2 (Option)<br />
Binder 712, 5 pin<br />
Serial connection RS232/485<br />
(Binder 763/ 5-pol)<br />
(M16 cable gland)
Display and Keypad<br />
By specifying the HygroFlex display and keypad option you gain useful<br />
functions: Local display of humidity, temperature and calculated<br />
humidity parameters such as dew-point, mixing ratio, wet-bulb.<br />
Through the keypad one can access the menu functions of the<br />
HygroFlex where the user can confi gure display settings, access the<br />
probe calibration functions, obtain a system status, select which<br />
probe to view and display serial numbers. The keypad can be locked<br />
to protect critical system and calibration settings.<br />
Order code:<br />
Digidisp-HTS<br />
(For retrofi tting non display versions)<br />
see also HygroFlex order code table<br />
Metal Housing<br />
Order code table for HygroFlex<br />
Here you can specify the full range of options and confi gurations for<br />
the various HygroFlex models.<br />
HygroFlex Options<br />
In the worst industrial environments the additional protection of a<br />
metal instrument housing helps to extend the product life. The<br />
HygroFlex optional metal housing is extremely robust and is available<br />
for all versions, with and without the display/keypad option.<br />
Ordering information: see HygroFlex order code table<br />
Radio option: (433.92 MHz)<br />
Wherever cabling is too complicated or too expensive, the radio option<br />
of the HygroFlex is a good choice. Distances up to 400 m in<br />
the fi eld or ~50 m inside buildings are bridged.<br />
HygroFlex transmitters may even be retrofi tted in the factory.<br />
Note: In some countries, radio operation is not allowed or requires<br />
a license.<br />
Order code: see table below.<br />
Other options<br />
HW3 software<br />
The HW3 software package has a comprehensive range of functions<br />
which are compatible with the HygroFlex, see chapter HW3 Software<br />
for full information.<br />
USB Adapter<br />
The USB Adaptor is used to connect the serial data cable to a USB<br />
port of a PC<br />
Order Code:<br />
12.02.1086<br />
H T S 1 1 X HygroFlex 1; 4…20 mA=0…100 %rh; 0…100°C; 12…35 VDC/24 VAC power<br />
H T S 2 1 X HygroFlex 2; digital outputs only; 12…35 VDC/24 VAC power; 2 probe inputs<br />
H T S 3 1 X HygroFlex 3; 4…20 mA=0…100 %rh; 0…100°C/°C dew-point; 12…35 VDC/24 VAC<br />
power; 2 probe inputs (1 optional);<br />
M Metal Housing<br />
1 12…35 VDC /24 VAC power<br />
2 90…250 VAC power<br />
X No display and keypad<br />
D Optional display and keypad<br />
/ 9 Customized version; Parameters to be specifi ed within the given limits<br />
(see technical data)<br />
R C Radio option<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
33
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
34<br />
HygroFlex Probes<br />
Fully interchangeable range of probes, simply choose the best version to suit your application. If your needs<br />
change, choose a different probe!<br />
HygroClip IW / IW1<br />
For wall mounting applications (area monitoring), lightweight construction<br />
for fast thermal response.<br />
Measurement range: 0…100 %rh, -40…85°C<br />
Accuracy: ±1 %rh/±0.2 K for IW1; ±1.5 %rh/±0.3 K for IW<br />
Probe: Delrin 25/15 mmØ<br />
Sensor protection: Wire mesh fi lter<br />
Order code:<br />
HygroClip IW1 (±1 %rh/0.2 K) with SCS certifi cate<br />
HygroClip IW<br />
Probe length: 145 mm Diameter: 15 mm<br />
HygroClip IC<br />
Cable mounted probe for fl exible installation in varied applications<br />
such as high temperatures, climatic chambers, ducts etc. Two versions<br />
are available, 100 & 250 mm probe length. Select appropriate cable<br />
length.<br />
Measurement range: 0…100 %rh, -50…200°C<br />
Probe: PPS 15 mmØ<br />
Cable: 2 m / 5 m / 10 m available on request, see below<br />
Order code:<br />
HygroClip IC1 100 mm probe<br />
HygroClip IC3 250 mm probe<br />
HygroClip IC-1/X X = 2 =^ 2 m cable<br />
X = 5 =^ 5 m cable<br />
X = 10 =^ 10 m cable<br />
Probe length: 100/250 mm Diameter: 15 mm Cable: 2 m<br />
HygroClip IM<br />
Robust stainless steel probe for duct, or through-wall installation.<br />
Suitable for use in the food industry. Select appropriate cable length.<br />
max. 200°C.<br />
Two versions are available, 120 & 270 mm probe length.<br />
Measurement range: 0…100 %rh, -50…200°C<br />
Probe: Stainless steel, 15 mmØ<br />
Cable: 2 m / 5 m / 10 m available on request<br />
Order code:<br />
HygroClip IM1 120 mm probe<br />
HygroClip IM3 270 mm probe<br />
HygroClip IM-1/X X=2 =^ 2m cable<br />
X=5 =^ 5 m cable<br />
X=10 =^ 10 m cable<br />
Probe length: 120/270 mm Diameter: 15 mm Cable: 2 m
HygroClip IE<br />
HygroFlex Probes<br />
For pressurised applications up to a maximum of 50 bar and temperatures<br />
of 100°C. Two versions are available with different threads 1⁄2" G<br />
or 1⁄2" NPT.<br />
Measurement range: 0…100 %rh, -50…100°C<br />
Probe: Stainless steel<br />
Cable: 2 m<br />
Order code:<br />
HygroClip IE-1 1⁄2" G pressure probe<br />
HygroClip IE-3 1⁄2" NPT pressure probe<br />
Screw-in probe Cable: 2 m<br />
HygroClip IC-04 / 05<br />
4/5 mm diameter probe for measurement in tight spaces such as<br />
climatic test applications, or monitoring conditions of materials.<br />
Max. 100°C<br />
Measurement range: 0...100 %rh, -40...100°C<br />
Probe: Nickel-plated brass<br />
Order code:<br />
HygroClip IC-04 4 mmØ probe with 2m cable<br />
HygroClip IC-05 5 mmØ probe with 2m cable<br />
Diameter: 5 mm Cable: 2 m<br />
HygroClip ICx with 15/25 mm probe<br />
HygroClip industrial probe with shaft diameter 15/25 mm to replace<br />
the old A-type duct probes of I-1000 and I-2000 series.<br />
No installation changes need to be made.<br />
Specifi cations are the same as for the standard HygroClip IC probes.<br />
The order codes are the same as for the standard probes, but with the<br />
extension HygroClip IC-x/15/25. The robust mechanical construction<br />
allows probe lengths up to 700 mm.<br />
Example: HygroClip IC-3/15/25 (Probe length = 250mm)<br />
Diameter: 15 mm Diameter: 25 mm Cable: 2 m<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
35
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
36<br />
SP-MSB15<br />
Metal slotted cap<br />
mounted over sensor<br />
Accessories<br />
Order code, fi lter, fi lter type, properties<br />
Function: Protects sensors against pollution and<br />
high air velocity (up to 40m/s).<br />
A fi lter is required for air velocity above 3m/s.<br />
HygroClip Industrial Probe Extension Cable<br />
Should you wish to extend the distance between the HygroFlex transmitter<br />
and probe, the extension cable AC1616 can be specifi ed with<br />
lengths up to 200m thanks to an integral signal booster.<br />
Order code:<br />
AC1616xxx Where required length xxx = 010 to 200 m, in steps<br />
of 10 m<br />
AC1619 Pair of connectors with electronics for customers<br />
own cable assembly.<br />
Probe options/fi lters/mounting hardware<br />
The robust slotted cap also functions as a fi lter holder and provides<br />
mechanical protection when the fi lter element is removed.<br />
Steel sinter fi lter SP-S15<br />
Wire mesh fi lter SP-M15<br />
Tefl on fi lter SP-T15<br />
Order code Type of fi lter Properties Max. air velocity<br />
SP-S15 Steel sinter fi lter element High level of fi ltration<br />
pore size ca. 5µ Marginal effect on response times.<br />
Not suitable for high humidity applications 40m/s<br />
SP-M15 Wire mesh fi lter element Minimal measuring delay<br />
Mesh size ca. 20-25µ Reduced fi ltration effi ciency for small particles.<br />
Suitable for high humidity applications 20m/s<br />
SP-T15 Tefl on fi lter element Good fi ltration effect<br />
pore size ca. 10µ Extends response time in low air velocity<br />
Water repellent but water vapour permeable 20m/s
ATEX 2180<br />
ATEX 2180<br />
ATEX 2180<br />
HygroClip EX<br />
HygroClip EX Digital EX Humidity and Temperature Measurement<br />
HygroClip EX is a series of probes for the measurement of humidity and temperature in hazardous areas<br />
featuring the latest digital signal processing and data transmission technology. Suitable for connection to<br />
the HygroFlex range of industrial transmitters, or for use as a stand alone 4…20 mA 2 wire transmitter, the<br />
HygroClip EX probes offer wide measurement ranges and fl exible installation options.<br />
The EX probes are based on ROTRONIC’s innovative HygroClip technology, which features a custom ASIC<br />
to provide the highest possible accuracy and features such as digital calibration and probe interchange ability.<br />
Each probe is constructed throughout from high grade stainless steel, with full IP65 protection. Each<br />
probe is fi tted with a replaceable fi lter system which protects the sensors from high air speeds, dust, grease<br />
etc.<br />
To comply with hazardous area standards, a Zener Barrier is required between the HygroClip EX probes and<br />
the HygroFlex, or when used as a 2 wire 4…20mA transmitter, between the probe and the control or monitoring<br />
system.<br />
All three probes measure over the range of 0…100 %rh thanks to the well proven Hygromer humidity sensor<br />
technology which has excellent long term stability, high tolerance to chemical contamination, and withstands<br />
exposure to condensation without any effect on calibration stability. Temperature range is dependent<br />
on the version used.<br />
HygroClip ID-EX<br />
Suitable for duct or through-the-wall installation with a robust<br />
250 x 15mm stainless steel probe. Temperature measuring range is<br />
0…100°C, provided the electronics enclosure does not exceed the Ex<br />
temperature rating (-20…40°C).<br />
Order code:<br />
HygroClip ID-EX<br />
HygroClip IC-EX<br />
Cable mounted probe for use in applications with high or low temperatures<br />
(-50…200°C) and where installation fl exibility is required.<br />
The robust stainless steel probe is available in two lengths, 120 and<br />
270 mm, and both are fi tted with a 2 m cable.<br />
Order code:<br />
HygroClip IC1-EX (120 mm)<br />
HygroClip IC2-EX (270 mm)<br />
HygroClip IW-EX<br />
For wall mounted applications with an external stainless probe<br />
(150 x 15 mm). Operating temperature: -20…40°C<br />
Order code:<br />
HygroClip IW-EX<br />
Note:<br />
The total cable length between the HygroClip EX probe and the<br />
HygroFlex transmitter must not exceed 200 m.<br />
:<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
37
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
38<br />
Digital EX Humidity Temp. Application<br />
Digital EX Humidity and Temperature Application<br />
Duct-mount probe Wall-mount probe Cable type
HygroClip EX Technical Specifi cations<br />
Specifi cations and Ordering Information<br />
Specifi cations HygroClip ID-EX HygroClip IW-EX HygroClip IC-EX<br />
Humidity measuring range 0…100 %rh<br />
Temperature measuring range -30…100°C* -20…40°C -50…200 °C<br />
Accuracy at 23°C ±1 %rh, ±0.2 K<br />
Repeatability < 0.5 %rh, 0.1°C<br />
Response Time
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
40<br />
+<br />
_ 1 2<br />
B4<br />
B3<br />
B2<br />
B1<br />
1<br />
A L M<br />
HygroFlex<br />
HygroFlex Maintenance and Calibration<br />
Probe of the<br />
intrinsically<br />
safe transmitter<br />
Probe of the<br />
intrinsically<br />
safe<br />
transmitter<br />
HygroPalm Remote Control of the HygroFlex<br />
Probe calibration<br />
Calibration device Calibration device<br />
Cable type<br />
SPB5-WIN<br />
Probe of the<br />
intrinsically<br />
safe transmitter<br />
Function HygroPalm 1 HygroPalm 2 HygroPalm 3<br />
Display the readings from any probe connected to the HygroFlex • • •<br />
Display the HygroFlex status (confi guration, serial number, etc.) N/A • •<br />
1-point adjustment of any HygroClip digital probe connected to the<br />
transmitter, using the probe connected to the HygroPalm as a reference N/A • •<br />
Access the functions (except for calculate and display) of the transmit-<br />
ter, primarily the adjust M.PT function for multi point probe calibration N/A N/A •<br />
Connecting cable required: AC1621 AC1620 AC1620<br />
HygroFlex Confi guration by direct PC connection<br />
It is possible to confi gure the HygroFlex by direct connection to the PC<br />
using the HW3 software and a connecting cable.<br />
Order Code:<br />
HygroData HTS for HygroFlex 2 and HygroFlex 3<br />
HygroData HTS1X for HygroFlex 1<br />
The HygroPalm handheld instrument<br />
can be connected to the<br />
HygroFlex, and depending on<br />
the version of the HygroPalm<br />
used, various tools and functions<br />
are available by remote control<br />
(see table below).<br />
This feature is especially useful<br />
for HygroFlex transmitters which<br />
are not specifi ed to include the<br />
display and keypad option.
Mounting plate of the Transmitter Enclosure<br />
The HygroFlex is comprised of 5 parts:<br />
1 mounting bracket<br />
2 electronics housing<br />
3 main circuit board<br />
4 connector plate<br />
5 front cover with or without optional display and keypad<br />
1<br />
2<br />
4<br />
To attach the transmitter to a mounting surface:<br />
1 Attach the mounting bracket to the mounting surface using<br />
4 screws as shown below.<br />
2 Slide the electronics housing down on the wall plate to the mechanical<br />
stop.<br />
80 mm<br />
3<br />
80 mm<br />
HygroFlex Installation<br />
5<br />
4x Ø3…5<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
41
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
42<br />
HygroFlex<br />
Dimensional diagrams & electrical connections<br />
Dimensions of housing Dimensions of mounting plate<br />
12 to 35 VDC or 12 to 24 VAC supply voltage and voltage output signals<br />
TB1 (1) 12…35 VDC (-) or 12…24 VAC Neutral TB2 (1) Relative humidity (+)<br />
TB1 (2) 12…35 VDC (+) or 12…24 VAC Phase TB2 (2) Temperature (+)<br />
TB1 (3) Ground TB2 (3) Calculated Parameter (+)<br />
TB2 (4) Common (-)<br />
90…264 VAC with optional power module and current output signals<br />
TB1 (1) Neutral 90…264 VAC TB2 (1) Relative humidity (+)<br />
TB1 (2) Phase 90…264 VAC TB2 (2) Temperature (+)<br />
TB1 (3) Ground TB2 (3) Calculated Parameter (+)<br />
TB2 (4) Common (-)
HygroFlex Technical Data<br />
Specifi cations HygroFlex 1 HygroFlex 2 HygroFlex 3<br />
Inputs<br />
Probe connections<br />
(combined %rh/°C) 1 2 2<br />
Signal input digital or analogue: 0…2,5 V, 10 Bit A/D, 15 V DC, max. 10 mA supply<br />
Third party probe input<br />
(1 analogue) No Yes Yes<br />
Outputs<br />
Analogue outputs 2 No 3<br />
Type of output analogue 0…1 V, 0…5 V, 0…10 V, No 0…1 V, 0…5 V, 0…10 V,<br />
(jumper selectable) 0…20 mA or 4…20 mA 0…20 mA or 4…20 mA<br />
RS232 output<br />
No Yes Yes<br />
Networkable, RS485 (up to 32 units) No Yes Yes<br />
Adjustment of probes<br />
1 point %rh, °C/°F Yes, with display/keypad option<br />
4 points %rh, 2 points °C/°F Yes, with display/keypad option<br />
4 points %rh, 2 points °C/°F,<br />
via PC No Yes Yes<br />
Test connector for communication<br />
with HygroPalm handheld Yes Yes Yes<br />
Calculation & Unit Display<br />
Calculated humidity values; No full range of calculated values including Dew-point,<br />
display and output wet-bulb, enthalpy, mixing ratio, water vapour pressure,<br />
sturation vapour pressure. User defi ned scale.<br />
Pressure compensation<br />
for calculated values No Manual or automatic with optional pressure probe<br />
Technical Data (included probes)<br />
Measuring range Probe dependent, 0…100 %rh, -50…200°C, 0…2000 hPa<br />
Accuracy at 23°C ±1,5 %rh, ±0,3 K<br />
Reproducibility Better than 0.5 %rh/ 0.1°C<br />
Sensors Hygromer IN-1 (rel. humidity), Pt100 1/3 DIN (Temperature)<br />
Electronic operating range 0…100%rh (not condensed), -40…60°C, with display -30…60°C<br />
Display/Keypad (Option) Liquid Crystal 3 line numeric<br />
Display resolution (Option) 0.1 %rF, 0.1°C, 0.01 calculated value<br />
Housing, dimensions IP65, ABS, 207 x 150 x 58,3 mm, Metal housing optional<br />
Weight 310 g<br />
Supply voltage Standard 12…35 V DC (140 mA), 12…24 V AC<br />
Optional 90…250 V AC, 3,5 VA<br />
Electrical connections M16 cable gland (7 mm cable)<br />
Connection terminals18 AWG<br />
Analogue output Current ouput (0/4…20 mA), max. load 500 Ω, others are jumper selectable<br />
(Factory setting 4…20 mA) Voltage (0…1, 5, 10 V),<br />
min. load 1000 Ω,<br />
CE-Conformity Complies to norms: EN50081-2, EN50082-2<br />
Order code table for HygroFlex<br />
Here you can specify the full range of options and confi gurations for<br />
the various HygroFlex models.<br />
H T S 1 1 X HygroFlex 1; 4…20 mA=0…100 %rh; 0…100 °C; 12…35 VDC/24 VAC power<br />
H T S 2 1 X HygroFlex 2; digital outputs only; DC/24 VAC power; 2 probe inputs<br />
H T S 3 1 X HygroFlex 3; 4…20 mA=0…100 %rh; 0…100°C/°C dew-point; 12…35 VDC/24 VAC<br />
power; 2 probe inputs;<br />
M Metal Housing<br />
1 12…35 VDC /24 VAC power<br />
2 90…250 VAC power<br />
X No display and keypad<br />
D No display and keypad<br />
/ 9 Customized version; Parameters to be specifi ed within the given limits<br />
(see technical data)<br />
R C Radio option<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
43
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
44<br />
HygroClip Alarm<br />
We have frequent requests for an alarm solution that is independent of other manufacturers control equipment,<br />
and which offers fl exible options for alarm or control. With the new HygroClip Alarm, we<br />
can now fulfi l these customer requests.<br />
HygroClip Alarm is a universal programmable alarm and control system that can either be interfaced with<br />
the HygroFlex, HygroLab and M-series instruments on an RS485 Bus, or operates independently from<br />
measurement equipment and PC’s. With four relays, it is possible to control four single alarm conditions or<br />
a block of up to 128 AND/OR linked alarms. The confi guration of the relays and the related logic array is performed<br />
with the Rotronic HW3 software to precisely meet the requirements of the user. The relays can be<br />
directly used for switching of loads up to 2500W.<br />
HygroClip Alarm may be used when connected to a PC or independently.<br />
A timer function may, for example, be used to control a ventilation system at nighttime, control opening<br />
and closing of the windows of a greenhouse, or switch lights depending on time etc.. The possible applications<br />
are extensive.<br />
Features<br />
• 4 alarm relays assigned to independent values<br />
• 1 alarm computed from up to 128 measured values (OR/AND linked)<br />
• Dew point calculation from humidity/temperature values<br />
• 2 digital inputs<br />
• 4 relay outputs (with status LED’s)<br />
• Real time clock with battery backup<br />
• Freely confi gurable internal logic, consisting of:<br />
- 12 Signal delays<br />
- 6 Flipfl ops<br />
- 12 Gates (AND / OR / XOR)<br />
- 2 Monofl ops<br />
- 1 Pulse width modulator<br />
- 2 Alarm times from the real time clock<br />
- 4 virtual keys (controlled by PC-software)<br />
- Event protocol generation by HW3Software<br />
Order code:<br />
HygroClip Alarm 1 with power supply 12…35 VDC/12…24 AC<br />
HygroClip Alarm 2 with power supply 90…250 VAC<br />
HW3 software<br />
Operation<br />
1. Query of measured values:<br />
The measurement data from a HygroFlex, HygroLab or M-series<br />
transmitter are queried via the RS485 network. If a preset alarm<br />
condition is detected, the device sets an alarm by switching on one<br />
or more relays according to the units programming. Any of the<br />
parameters measured by the instruments mentioned above can be<br />
monitored (humidity, temperature, pressure, air fl ow etc.)<br />
2. Independent control unit<br />
HygroClip Alarm may be used as an independent control unit, and<br />
as such, switch various devices. For example, switching on a ventilation<br />
unit for 10 minutes every hour. In this mode, HygroClip<br />
Alarm is completely independent of any PC or other device.<br />
3. Remote control<br />
Using HW3 software, virtual keys can be operated. This may be<br />
useful to cancel an alarm or switch a relay remotely.<br />
Note: On request, we offer a programming service for this product.
Operating modes<br />
For HygroClip Alarm, two operating modes are available:<br />
Easy and Expert modes.<br />
Easy Mode<br />
In the Easy Mode, HygroClip Alarm is confi gured using the HW3 software.<br />
The user interface allows only the most important functions,<br />
which makes programming very easy. As a maximum, 4 parameters<br />
and 2 external signals (switches) can be processed.<br />
Expert Mode<br />
HygroClip Alarm<br />
In the Expert Mode, the functions can be displayed graphically and<br />
directly programmed by dragging and dropping various logic symbols.<br />
The logic links allow very complex functions. Programming is performed<br />
directly within HW3 software and is organised in a user-friendly<br />
way.<br />
Data logging<br />
Data logging is performed by the HW3 software. All alarm events are<br />
logged together with the measured values.<br />
Even if the PC is switched off (e.g. due to power failure or at night<br />
time), HygroClip Alarm logs up to 20 events. These may be evaluated<br />
afterwards from a PC.<br />
Technical Data HygroClip Alarm<br />
Power supply 90…250 VAC or 12…35 VDC / 12…24 VAC<br />
Power consumption 50 mA (without relays)<br />
Inputs 2 digital inputs 0…5 V or switches<br />
Outputs 4 Relays (10 A @ 250 VAC/30 VDC, 12 A @ 125 VAC)<br />
Clock Real-time clock<br />
Interface RS485 interface<br />
Radio interface optional<br />
Housing material Makrolon<br />
Dimensions 160 x120 x 75 mm<br />
Electrical connections 3x M12, 5x M16 Cable glands<br />
Protection class IP65<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
45
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
46<br />
M-Series & Roline-L Series<br />
The measurement of temperature and humidity in HVAC/BMS applications becomes more demanding<br />
with almost every year. Heating, air conditioning and ventilation get more and more sophisticated. Cooled<br />
ceilings provide an agreeable atmosphere, where hardly any draught may be felt. The exchange of air in<br />
buildings is reduced to the minimum in order to save energy. The temperature and humidity values are<br />
regulated within ever-smaller margins. Obviously, the accuracy of the measuring instruments must be<br />
better than a few years ago. In such demanding environments, the measuring equipment had to compete<br />
with the demands. ROTRONIC has developed new instruments that suit the requirements of today and<br />
certainly also of the future. However, there are still other applications, where the utmost accuracy is not<br />
asked for. For these, ROTRONIC has developed a new line of economically priced instruments also: The<br />
Roline-L.<br />
The new M-Line of ROTRONIC represents the latest development in digital humidity measurement. The<br />
well known and established FT and FH series are now replaced by the new instruments, which offer much<br />
greater application fl exibility due to the fact that the output signals are scaleable. Hence, the resolution<br />
becomes better, because it is possible to scale the output of e.g. 0…10 °C to 4…20 mA. In fact, any range<br />
may be scaled exactly according to your needs. For applications in which the range of the measured values<br />
is always in a limited range, this represents a remarkable advantage. Control can be made much more effi<br />
cient and accurate. ROTRONIC provides a number of standard versions types usually from stock. However,<br />
customized instruments are available on request from your distributor.<br />
Key features<br />
• Compact, modern instruments<br />
• Optional display with good contrast<br />
• Accuracy and long term stability<br />
• Interchangeable sensor module<br />
• Scaleable output signals<br />
• All standard signals available<br />
• Aesthetic housing<br />
• Psychrometric Calculations<br />
Your benefi ts<br />
� Easy to handle and fl exible<br />
� Easy observation of measured values<br />
� Reliable data and reduced maintenance<br />
� Easy calibration & maintenance<br />
� Better resolution, more precise control<br />
� One instrument for different control systems<br />
� Use also in living spaces<br />
� No need for external calculators<br />
This section contains Page<br />
New M-Series 48 to 52<br />
� Interchangeable probes<br />
� Optional Display<br />
� Scaleable Output Signals<br />
� Psychrometric Calculations<br />
� High Accuracy<br />
� Remote Adjustment with Handheld<br />
New Roline-L Series 53 to 54<br />
� Best price-performance ratio<br />
� Fixed probe<br />
� 2x2 wire technology<br />
� Single signal use<br />
� Remote adjustment with handheld
Storage rooms<br />
Railway stations<br />
Computer/Server rooms<br />
Snow Guns<br />
M-Series Applications Overview<br />
Cold stores<br />
Libraries<br />
Museums<br />
Green houses<br />
Climate control<br />
in offi ce buildings<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
47
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
48<br />
ROTRONIC M-Series Transmitters<br />
General Description<br />
The new ROTRONIC M-series transmitters are the latest development of combined humidity / temperature<br />
transmitters, based on HygroClip technology. Output signals of 0…1 V, 0…5 V, 0…10 V, 0…20 mA or 4…<br />
20 mA are available. The M-Series consists of three models; each offering different features to suit the application<br />
needs, and with the facilities which can be reprogrammed by the customer or reseller. The main<br />
differentiation between the three M Series is as follows:<br />
M1 Humidity and temperature transmitters with fi xed probe, with electronics based on digital technology<br />
M2 Humidity and temperature transmitter with interchangeable HygroClip probes<br />
M3 Humidity, calculated humidity (e.g. dew point, enthalpy) and temperature transmitter with<br />
interchangeable HygroClip probes<br />
M1<br />
Key features<br />
• Fixed probe<br />
• Wall, space and duct mounting versions<br />
• Combined relative humidity and temperature measurement<br />
• Digital technology<br />
• Wide measuring range<br />
• Excellent long-term stability<br />
• High accuracy<br />
• Remote diagnosis with handheld instrument<br />
• Temperature range –40…60°C<br />
• Standard output signals (current / voltage)<br />
• Wire mesh fi lter provides sensor protection against<br />
dust and high air velocity.<br />
• IP rating: IP65; IP52 for space version<br />
Ordering Information Standard M1 with fi xed probes<br />
Order code Description Electrical connection Applications<br />
M12D2HT-1X Duct-mount, 0...50 °C / 0...100 %rh 2 wire 4...20 mA, 10…35 VDC<br />
M12D2HT-4X Duct-mount, -30...70 °C / 0...100 %rh<br />
M12W2HT-1X Wall-mount, 0...50 °C / 0...100 %rh<br />
M12W2HT-4X Wall-mount, -30...70 °C / 0...100 %rh<br />
M12S2HT-1X Space mount, 0...50 °C / 0...100 %rh<br />
M12S2HT-4X Space mount, -30...70 °C / 0...100 %rh HVAC Applications<br />
M12S2HT-2X Space mount, 10...40 °C / 0...100 %rh Cold Rooms<br />
M13D2HT-1X Duct-mount, 0...50 °C / 0...100 %rh 12...35 VDC/24 VAC / 4...20 mA Storage rooms<br />
M13D2HT-4X Duct-mount, -30...70 °C / 0...100 %rh 3/4 wires Semicond. Industry<br />
M13W2HT-1X Wall-mount, 0...50 °C / 0...100 %rh<br />
M13W2HT-4X Wall-mount, -30...70 °C / 0...100 %rh<br />
M13S2HT-1X Space mount, 0...50 °C / 0...100 %rh Any application, where<br />
M13S2HT-4X Space mount, -30...70 °C / 0...100 %rh probes must not be<br />
M13D5HT-1X Duct-mount, 0...50 °C / 0...100 %rh 12...35 VDC/24 VAC / 0...10 V removed or exchanged.<br />
M13W5HT-4X Wall-mount, -30...70 °C / 0...100 %rh 3/4 wires<br />
M13S5HT-1X Space mount, 0...50 °C / 0...100 %rh<br />
M13D5HT-4X Duct-mount, -30...70 °C / 0...100 %rh<br />
M13W5HT-4X Wall-mount, -30...70 °C / 0...100 %rh<br />
M13S5HT-4X Space mount, -30...70 °C / 0...100 %rh<br />
The probe length of all duct mount transmitters is 207 mm; 52 mm for wall mount types<br />
For non-standard ordering information, please see table on page 51.<br />
HW3 software<br />
The HW3 software package has a comprehensive range of functions which are compatible with the M-<br />
Series, see chapter HW3 Software for full information.
M2<br />
Humidity and temperature transmitter<br />
with interchangeable HygroClip S probes<br />
Key features<br />
• Probe interchangeable within seconds<br />
• Wall and duct mounting types<br />
• Measures humidity and temperature simultaneously<br />
• Use of digital technology<br />
• Wide measuring range<br />
• Excellent long-term stability<br />
• High accuracy ±1.5 %rh, 0.3 K<br />
• Optional display<br />
• Remote diagnosis with handheld instrument<br />
• Temperature range –40…60°C/-30…60°C with display<br />
• Wire mesh fi lter provides sensor protection<br />
against dust and high air velocity.<br />
• IP rating: IP65<br />
HygroClip Probes for M-Series transmitters<br />
HygroClip S<br />
Standard sensor module for humidity and temperature.<br />
A wire mesh fi lter provides sensor protection against dust<br />
and high air velocity. Dimensions Ø15 x 100 mm.<br />
IP rating: IP65<br />
Measurement range: -40…85 °C , 0…100 %rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23 °C)<br />
Order code:<br />
HygroClip S<br />
Extension cable with<br />
1 / 2 / 5 m cable length<br />
for HygroClip S probes and M-Series transmitters<br />
Order code:<br />
MOK-01-DAT05 1 m<br />
MOK-02-DAT05 2 m<br />
MOK-05-DAT05 5 m<br />
ROTRONIC M-Series Transmitters<br />
����<br />
���� ��<br />
Ordering Information Standard M2 with interchangeable probes<br />
Order code Specifi cation Power supply Applications<br />
M22D2HT-1X Duct-mount, 0...50 °C / 0...100 %rh 2 wire 4...20 mA, 10…35 VDC<br />
M22D2HT-4X Duct-mount, -30...70 °C / 0...100 %rh HVAC Applications<br />
M22W2HT-1X Wall-mount, 0...50 °C / 0...100 %rh Cold Rooms<br />
M22W2HT-4X Wall-mount, -30...70 °C / 0...100 %rh Storage rooms<br />
M23D2HT-1X Duct-mount, 0...50 °C / 0...100 %rh 12...35 VDC/24 VAC / 4...20 mA Semiconductor Industry<br />
M23D2HT-4X Duct-mount, -30...70 °C / 0...100 %rh 3/4 wires Light industry<br />
M23W2HT-1X Wall-mount, 0...50 °C / 0...100 %rh<br />
M23W2HT-4X Wall-mount, -30...70 °C / 0...100 %rh Any application,<br />
M23D5HT-1X Duct-mount, 0...50 °C / 0...100 %rh 15...35 VDC/24 VAC / 0...10 V where probes must<br />
M23D5HT-4X Duct-mount, -30...70 °C / 0...100 %rh 3/4 wires be easy to exchange.<br />
M23W5HT-1X Wall-mount, 0...50 °C / 0...100 %rh<br />
M23W5HT-4X Wall-mount, -30...70 °C / 0...100 %rh<br />
The probe length of all M2 standard duct-type transmitters is 250 mm; 100 mm for wall mount types.<br />
Order Codes Non-Standard Types M2 –please see table on page 51<br />
�� �<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
49
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
50<br />
����<br />
���� ��<br />
�� �<br />
ROTRONIC M-Series Transmitters<br />
Ordering Information Standard Types M3 with Calculations &<br />
interchangeable Probes<br />
Order code Specifi cation Power supply Applications<br />
M33D2TC-4XW09 Duct-mount<br />
-30...70°C, -25...25°C / Dew-Point<br />
M33D2TC-4XW0B Duct-mount<br />
-30...70°C, -50...50°C / Dew-Point<br />
M33D2TC-4XW24 Duct-mount<br />
-30...70°C, 0...100 kJ/kg / Enthalpy 12...35 VDC/24VAC / 4...20 mA Snow Guns<br />
M33D2TC-4XW53 Duct-mount 3/4 wires Drying processes<br />
-30...70°C, 0...50 g/kg / Mixing Ratio (R)<br />
M33D2TC-4XW54 Duct-mount<br />
-30...70°C, 0...100 g/kg / Mixing Ratio (R)<br />
Wall mount-types are available on request;<br />
see order code table on next page<br />
M3<br />
The probe length of all M3 standard duct-type transmitters is 250 mm; 100 mm for wall mount types.<br />
Order Codes Non-Standard Types M3 – please see table on page 51.<br />
Humidity, calculated humidity (e.g. dewpoint, enthalpy) and temperature<br />
transmitter with interchangeable HygroClip S probes<br />
Key Features<br />
• Psychrometric calculations available (dewpoint, enthalpy etc.)<br />
• Probe interchangeable within seconds<br />
• Wall- and duct-mounting types<br />
• Measures humidity and temperature simultaneously<br />
• Use of digital technology<br />
• Large measuring range<br />
• Excellent long-term stability<br />
• High accuracy<br />
• Optional display<br />
• Remote diagnosis with handheld instrument<br />
• Temperature range –40…60°C; -30…60°C with display<br />
• Wire mesh fi lter provides sensor protection<br />
against dust and high air velocity.<br />
• IP rating: IP65<br />
HygroClip Probes for M-Series transmitters<br />
HygroClip S<br />
Standard sensor module for humidity and temperature.<br />
A wire mesh fi lter provides sensor protection against dust<br />
and high air velocity. Dimensions: Ø15 x 100 mm.<br />
IP rating: IP65<br />
Measurement range: -40…85°C , 0…100 %rh<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip S<br />
Extension cable with<br />
1 / 2 / 5 m cable length<br />
for HygroClip S probes and M-Series transmitters<br />
Order code:<br />
MOK-01-DAT05 1 m<br />
MOK-02-DAT05 2 m<br />
MOK-05-DAT05 5 m
Order Codes Non-Standard M Series<br />
ROTRONIC M-Series Transmitters<br />
Specifi cation 1 2 3 4 5 6 7 8 9 10 11 12 13<br />
Type M1 & M2 Integrated probe M 1 -<br />
Interchangeable probe 2<br />
Type of connection 2-wire 4...20 mA 2<br />
12...35 VDC, 24 VAC 3/4 wire 3<br />
Mounting Duct D<br />
Wall W<br />
Space S (M1 only)<br />
Output signal type 0...20 mA 1<br />
4...20 mA 2<br />
0...1 V 3<br />
0...5 V 4<br />
0...10 V 5<br />
Output parameters Humidity & temperature H T<br />
Humidity only H X<br />
Temperature only X T<br />
Output range 0…50°C / 0…100 %rh - 1<br />
Temperature & humidity 10…40°C / 0…100 %rh 2<br />
-40…60°C / 0…100 %rh 3<br />
-30…70°C / 0…100 %rh 4<br />
-40…85°C/ 0…100%rh 5<br />
0…100°F 6<br />
Options Display (not for M1) D<br />
No Display X<br />
Specifi cation 1 2 3 4 5 6 7 8 9 10 11 12 13<br />
Type M3 Interchangeable probe & calculation M 3<br />
Type of connection 12...35 VDC, 24 VAC 3/4 wire 3<br />
Mounting Duct D<br />
Wall W<br />
Output signal type 0...20 mA 1<br />
4...20 mA 2<br />
0...1 V 3<br />
0...5 V 4<br />
0...10 V 5<br />
Output parameters Humidity & calculated value H C<br />
Temperature & calculated Value T C<br />
Output range -30…70°C / 0…100 %rh - 4<br />
Temperature & humidity 0…100°F / 0…100 %rh 6<br />
Options Display D<br />
No display X<br />
Standard wire communication W<br />
Radio communication (M3 only) R<br />
Calculated parameter Dew-Point Dp in °C 0<br />
Wet-Bulb temperature Tw in °C 1<br />
Enthalpy H in kJ/kg 2<br />
Mixing ratio R in g/kg 5<br />
Output range 0…20 1<br />
Calculated value 0…25 2<br />
0…50 3<br />
0…100 4<br />
0…200 5<br />
0...500 6<br />
0...1000 7<br />
-20...20 8<br />
-25...25 9<br />
-40…40 A<br />
-50…50 B<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
51
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
52<br />
Technical Data Summary M-Line<br />
Features M 1 M 2 M 3<br />
Humidity sensor AC-1<br />
Temperature sensor Pt100 B Pt100 1/3 DIN<br />
Probe connections (combined %rh/°C) Fixed probe 1 for exchangeable HygroClip probes<br />
RS232 Service Interface Yes, by HygroPalm<br />
Display No Option<br />
Display units %rh, °C, °F, calculated parameters (M3 only)<br />
Resolution 0.1 %rh / 0.1°C<br />
Output signal type 0…1/5/10 V; 0/4…20 mA<br />
Trend indicator No Yes, with display option<br />
RS485 vernetzbar No Option<br />
Radio transmission No Option<br />
Serial number stored in EE-Prom Yes<br />
Scaleable analogue outputs Yes, with HW3 Software<br />
Remote Functions with HygroPalm<br />
1 point %rh, °C probe adjustment Yes<br />
4 point %rh, 2 point °C probe adjustm. Yes<br />
Reference adjustment Yes<br />
Calculation & Unit Display<br />
Psychrometric calculations No Yes<br />
Pressure compens. of calculated values No Possible with HW3 Software<br />
Standard pressure constant value No 1013.25 hPa<br />
Remote Transmitter Control<br />
Transmitter adjustment 1 point 1 point Multiple points<br />
Transmitter adjustment against<br />
reference probe Yes, with HygroPalm<br />
Transmitter measurement display Yes, with HygroPalm<br />
Transmitter status display Yes, with HygroPalm<br />
Operating range<br />
Operating range of electronics -40…60°C, with display -30…60°C<br />
Measuring Ranges (probes)<br />
Humidity 0…100 %rh<br />
Temperature Probe dependent; max. –40…100°C<br />
Accuracy at 23°C ±1.5%rh /± 0.3 K<br />
Reproducibility < 0.5%<br />
Long term stability < 1%rh / year<br />
Electrical Data<br />
Power supply 10(15)…35 VDC / 12…24 VAC or 2 wire 4…20 mA, 10…35 VDC<br />
Maximum load Current Output: < 250 Ohm; Voltage Output > 1000 Ohms<br />
Automatic load compensation No Yes<br />
Electrical connection Screw terminals on connection plate<br />
Mechanical Data<br />
Type of enclosure/ IP rating IP 65<br />
Sensor protection Type SP-W15 Wire mesh fi lter, stainless steel<br />
Housing material ABS<br />
Probe length/diameter for<br />
Duct type / Wall type 207/15/52/15 mm 250/15 mm/100 /15 mm<br />
Dimensions 154 x 73 x 48 mm<br />
Weight Ca. 300 g<br />
Schematics and dimensional diagrams see page 55 + 57
Roline-L Series Transmitters<br />
The Roline L transmitter has been designed for cost sensitive applications where the highest accuracy or<br />
widest measuring ranges are not required. Two versions are available, 2 wire 4…20mA loop and 3/4 wire<br />
formats for current and voltage signals.<br />
L12<br />
• 2 wire or 2x2 wire loop powered 4…20 mA<br />
• Integrated probe<br />
• Duct and wall mounting versions<br />
• Combined humidity and temperature measurement<br />
• Humidity or temperature only versions<br />
• Use of digital technology<br />
• Excellent long-term stability<br />
• Good accuracy<br />
• Temperature range 5…50°C<br />
• Humidity range 10…100%rh<br />
L13<br />
• 3/4 wire model for 10…35 VDC /12…24 VAC supply<br />
• 4…20 mA, 0…20mA, 0…10 V outputs<br />
• Integrated probe<br />
• Duct and wall mounting versions<br />
• Combined humidity and temperature measurement<br />
• Humidity or temperature only versions<br />
• Use of digital technology<br />
• Excellent long-term stability<br />
• Good accuracy<br />
• Temperature range 0…50°C<br />
• Humidity range 0…100 %rh<br />
Ordering Information Standard Versions Roline L<br />
Key features<br />
Roline-L Serie<br />
The transmitters that are defi ned in the table below represent the most popular versions.<br />
Customized versions may be ordered according to the table on the next page.<br />
• Compact, modern instruments<br />
• Good long term stability<br />
• All standard output signals<br />
available<br />
• Aesthetic housing<br />
Your benefi ts<br />
� Easy to install<br />
� Reliable data and reduced<br />
maintenance<br />
� Compatible with most control<br />
systems<br />
� Suitable for public areas<br />
Orde code Description Supply / Output Applications<br />
L12DHT2 Duct-mount, 0…50°C / 0…100 %rh 2-wire 4…20 mA ; 10…28 VDC HVAC applications,<br />
low installation costs<br />
L12DHX2 Duct-mount, 0…100 %rh Humidity measurem. only<br />
L12DTX2 Duct-mount, 0…50°C Temp. measurement only<br />
L12WHT2 Wall mount, 0…50°C / 0…100 %rh HVAC applications,<br />
low installation costs<br />
L12WHX2 Wall mount, 0…100 %rh Humidity measurem. only<br />
L12WTX2 Wall mount, 0…50°C Temp. measurement only<br />
L13DHT2 Duct-mount, 0…50°C / 0…100 %rh 3/4-wire 4…20 mA; HVAC applications,<br />
10 (15)…35 VDC; 12…24 VAC low installation costs<br />
L13DHX2 Duct-mount, 0…100 %rh Humidity measurem. only<br />
L13DTX2 Duct-mount, 0…50°C Temp. measurement only<br />
L13WHT2 Wall mount, 0…50°C / 0…100 %rh HVAC applications,<br />
low installation costs<br />
L13WHX2 Wall mount, 0…100 %rh Humidity measurem. only<br />
L13WTX2 Wall mount, 0…50°C Temp. measurement only<br />
L13DHT5 Duct-mount, 0…50°C / 0…100 %rh 3/4-wire 0…10 V; HVAC applications,<br />
10 (15)…35 VDC; 12…24 VAC low installation costs<br />
L13DHX5 Duct-mount, 0…100 %rh Humidity measurem. only<br />
L13DTX5 Duct-mount, 0…50°C Temp. measurement only<br />
L13WHT5 Wall mount, 0…50°C / 0…100 %rh HVAC applications,<br />
low installation costs<br />
L13WHX5 Wall mount,, 0…100 %rh Humidity measurem. only<br />
L13WTX5 Wall mount,, 0…50°C Temp. measurement only<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
53
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
54<br />
Roline-L Series Transmitters<br />
Ordering Information & dimensional diagrams Roline-L Series<br />
Features 1 2 3 4 5 6 7<br />
Roline-L types with integrated probes L 1<br />
Type of connection 2 wire loop power 4...20 mA 2<br />
12*...35 VDC, 3/4 wire 3<br />
Mounting Duct (Probe length 205 mm) D<br />
Wall ( Probe length 55 mm) W<br />
Output Parameters Humidity & Temperature H T<br />
Humidity only H X<br />
Temperature only T X<br />
Output Signal Type 0...20 mA (not for L12) 1<br />
* for 0/4…20 mA and 0…10 V outputs<br />
4...20 mA 2<br />
0...1 V (not for L12) 3<br />
0...5 V (not for L12) 4<br />
0...10 V (not for L12) 5<br />
Technical Data Summary Roline-L Series<br />
Specifi cations L 12 L13<br />
Humidity sensor Hygromer AC-1<br />
Temperature sensor Pt 100 B<br />
Output signal type 2 x 2 wire 4…20 mA loop power 0…1/5/10 V; 0/4…20 mA<br />
Probe adjustment In conjunction with HygroPalm handheld instrument<br />
Operating & measuring ranges<br />
Humidity 0…100 %rh, non condensing<br />
Temperature -40…60°C<br />
Air speed duct type 20 m/s max.<br />
Temperature compensation Yes<br />
Accuracy at 23°C ±3 %rh; ±0.5 K<br />
Reproducibility < 0.6 %rh / 0.5 K<br />
Long Term Stability < 1.5 %rh/Year<br />
Power Supply 2 wire 4…20mA loop power; 10…28 VDC 10(15)…35 VDC<br />
Power consumption Max. 20 mA /output < 50 mA<br />
Max. load
M-Series & Roline-L Series<br />
ACML 232<br />
ACRL<br />
ACRLXB5<br />
ACRLYB5<br />
Schematics and dimensional diagrams<br />
Schematic diagrams 3/4 wire supply 2 or 2x2 wire supply<br />
Service cable<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
55
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
56<br />
The I-1020 series has been ROTRONIC’s best selling product for industrial applications for many years, and<br />
is still in great demand, especially in 2x2 wire loop power applications. This is why ROTRONIC still produces<br />
the I-1020 despite of the availability of the HygroFlex series. Its high precision, reliability and extensive<br />
range of confi guration options make it ideally suited to the most stringent demands of the industrial sector.<br />
Ø 25 Ø 15<br />
A B<br />
L<br />
A = 150 mm<br />
B = 100 / 250 / 400 / 550 mm<br />
L = 250 / 400 / 550 / 700 mm<br />
L<br />
Ø 15<br />
(130 mm to 80 °C)<br />
L = 100 / 130 / 250/400/<br />
550 / 700 mm<br />
Cable lengths 1 m / 2 m<br />
L<br />
(130 mm to 80 °C)<br />
Cable lengths 1 m / 2 m<br />
L<br />
L = 120 / 270 / 420 mm<br />
Transmitter I-1020<br />
L<br />
L = 100 mm<br />
Ø15 mm<br />
L = 100 / 130 / 250 / 400/<br />
550 / 700 mm<br />
Ø15 mm<br />
I-1020<br />
Key features<br />
• Excellent precision and long-term stability<br />
• Wall, duct or cable mounting<br />
• Measurement of relative humidity & temperature<br />
• Wide operating ranges: 0…100 %rh, -50…150°C<br />
• 2x2 wire loop power output : 4…20 mA<br />
Probes<br />
Passive PPS probe with sealed cable, used for all three mounting confi<br />
gurations.<br />
Advantage: No hollow spaces, therefore no possibility of leakage or<br />
trapped condensation. Various combinations of transmitters<br />
and probes are available for the different demands<br />
in all types of applications<br />
Wall mount type P<br />
Temperature range: -20...50°C<br />
Length: 100 mm<br />
Probe: PPS, sealed against condensation<br />
Duct Mount Type A<br />
Standard probe length: 250 mm<br />
Temperature range: -50…150°C<br />
Probe: PPS, sealed against condensation<br />
Duct Mount Type P<br />
Standard probe length: 250 mm<br />
Temperature range: -50…150°C<br />
Probe: PPS, sealed against condensation<br />
Cable mount type P<br />
Temperature range: -50…150°C<br />
Probe: PPS, sealed against condensation<br />
Cable lengths: 1 or 2 m<br />
Cable mount type M (option)<br />
Temperature range: -50…150°C<br />
Probe: Steel V2A<br />
Cable lengths: 1 or 2 m<br />
Length: 120 / 270 / 420 mm<br />
Diameter: 15 mm
Sensor protection, fi lters<br />
M-Series Schematics Model M3 with calculation<br />
M1 M2 + M3<br />
I-1020 Sensor protection, fi lters<br />
The robust slotted cap also functions as a fi lter holder and provides mechanical protection when the fi lter<br />
element is removed.<br />
SP-MSB15<br />
Metal slotted cap<br />
mounted over sensor<br />
Order code, fi lter, fi lter type, properties<br />
Function: Protects sensors against pollution and<br />
high air velocity (up to 40 m/s).<br />
A fi lter is required for air velocities from 3 m/s.<br />
Steel sinter fi lter SP-S15<br />
Wire mesh fi lter SP-M15<br />
Tefl on fi lter SP-T15<br />
Order code Type of fi lter Properties Max. air velocity<br />
SP-S15 Steel sinter fi lter element High level of fi ltration<br />
pore size ca. 5µ Marginal effect on response times<br />
Not suitable for very high humidity applications 40m/s<br />
SP-M15 Wire mesh fi lter element Minimal measuring delay<br />
Mesh size ca. 20–25µ Reduced fi ltration effi ciency for small particles.<br />
Suitable for high humidity applications 20m/s<br />
SP-T15 Tefl on fi lter element Good fi ltration effect<br />
pore size ca. 10µ Extends response time in low air velocity<br />
Water repellent but water vapour permeable 20m/s<br />
Power Supply<br />
+ 1 Supply, max. 35 V DC, 24 V AC<br />
– 2 GND (common)<br />
+ 3 Temperature [V, mA]<br />
+ 4 Calculated value [V, mA]<br />
+ 5<br />
] RS485<br />
– 6<br />
Dimensional Diagrams M-Series<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
57
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
58<br />
I-1020<br />
Order code table series I-1020<br />
Parameter column number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18<br />
Example: 1 - 1 0 2 2 C C 0 2 P 3 C W 1 V 1 X<br />
Supply voltage: 2x2 wire 4…20 mA 2<br />
Temperature measuring range<br />
No temperature measurement 0 T<br />
0…50°C 1 C<br />
0…100°C 2 C<br />
0…150°C 3 C<br />
–30…70°C 4 C<br />
other in °C 9 C<br />
0…10°F 1 F<br />
0…200°F 2 F<br />
other in °F 9 F<br />
Type of mounting<br />
Wall (100 mm probe length) W X X<br />
Duct R X X<br />
Cable-probe 1 m (incl. probe) C 0 1<br />
Cable-probe 2 m (incl. probe) C 0 2<br />
Probe type<br />
PPS probe type A 25/15 mm Ø A<br />
PPS probe type P 15 mm Ø P<br />
Metal probe 15 mm Ø (Cable type only) M<br />
Probe length<br />
Mounting type W and C: 100 mm<br />
Metal probe: 120 mm Not available for probe type A 1<br />
Mounting type R und C: 130 mm (up to 80°C) Not available for probe type A 2<br />
Mounting type R und C: 250 mm Metal probe: 270 mm 3<br />
Mounting type R und C: 400 mm Metal probe: 420 mm 4<br />
Mounting type R und C 550 mm 5<br />
Mounting type C 700 mm 7<br />
Measured parameter<br />
Humidity & Temperature measurement C W<br />
Temperature measurement only C T<br />
Output signal:<br />
Current: 4…20 mA, 2 wire 6 A<br />
Current: 2x4…2 0mA, 2x2 wire 8 A<br />
Cable connections:<br />
1 M16 cable gland 1<br />
Tuchel plug 7 pin 7<br />
Special version 9 X<br />
Filter options<br />
to be ordered separately<br />
Order code:<br />
SP-S15 Steel sinter fi lter element<br />
SP-M15 Wire mesh fi lter element<br />
SP-T15 Tefl on fi lter element<br />
Service cable for adjusting of the transmitters<br />
Order code:<br />
ET-86.1708.0501
Technical data series I-1020<br />
Humidity sensor HYGROMER ® IN-1<br />
Temperature sensor Pt100 1/3 DIN<br />
Operating range<br />
Humidity 0…100 %rh<br />
Temperature (sensor) -50…150°C<br />
Temperature (Electronics) -20…50°C<br />
Technical data series I-1020<br />
Air velocity Without fi lter up to 3m/s, with fi lter up to 40m/s<br />
Measuring range<br />
Humidity 0…100 %rh<br />
Temperature See order code table<br />
Temperature compensation: Within temperature range 0…100°C<br />
Output signals humidity and temperature 2-wire loop power 4…20 mA<br />
Accuracy humidity at 23 ±2°C Humidity ±1.5 %rh, 0…100 %rh<br />
Temperature ±0.3 K<br />
Reproducibility 0.5 %rh, 0.1 K<br />
Long-term stability
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
60<br />
Dimensions of the electronics housing<br />
I-1020<br />
Order codes Screw fi tting Probe Ø max. temperature AG H (mm) Flange<br />
AC1301 Perbunan 15 mm 100 °C 1⁄2"G 28 AC 1305<br />
AC1301-M* Perbunan 15 mm 100 °C M 25 x 1.5 26 On request<br />
AC1302 Perbunan 25 mm 100 °C 1"G 33 AC 1306<br />
AC1302-M* Perbunan 25 mm 100 °C M 32 x 1.5 31.5 On request<br />
AC1303 Viton 15 mm 200 °C 1⁄2"G 28 AC 1305<br />
AC1303-M* Viton D 15 mm 200 °C M 25 x 1.5 26 On request<br />
AC1304 Viton 25 mm 200 °C 1"G 33 AC 1306<br />
AC1304-M* Viton 25 mm 200 °C M 32 x 1.5 31.5 On request<br />
* M = Metric thread<br />
I-1020<br />
Fitting Flange Version B<br />
Remark:<br />
The dimensions in brackets apply to probes with 25 mm Ø.<br />
Aluminium housing<br />
on request<br />
Mounting accessories for all transmitters with 15 mm probes<br />
1. Wall mounting: no accessories required. Electronics housing mounted on wall.<br />
2. Duct mounting:<br />
A: Electronics housing mounted on air duct. No accessories required<br />
B: Probe mounted by AGRO screw fi tting and fl ange ( Duct and cable types)<br />
The fl ange is only required, if the AGRO screw fi tting cannot<br />
be fi xed alone; e.g in small ducts with no access
Installation of ROTRONIC transmitters is easy. The various models can be mounted either by a mounting<br />
plate, onto which the whole transmitter is fi xed, by a connecting plate, which is screwed onto the wall or<br />
duct, or by direct mounting onto a duct by fi xing the probe with an AGRO fi tting. See also previous page.<br />
Mounting of M-Series Transmitters<br />
1. Mount the base/mounting<br />
plate onto the wall and connect<br />
the wiring.<br />
2. Plug in the probe/electronics<br />
module<br />
The base/mounting plate is<br />
absolutely identical to the old<br />
versions of the FTW65, DPT and<br />
FH types.<br />
The M1 space mount version<br />
features a retractable probe.<br />
This is especially convenient for<br />
calibration. In areas with no air<br />
movement, the measurement is<br />
much more accurate due to the<br />
better adaptation to the temperature.<br />
Mounting of Roline-L Types<br />
Fix the housing by screwing it directly<br />
onto the wall, or by means<br />
of an AGRO fi tting.<br />
Mounting of I-1020 types<br />
52<br />
52<br />
Installation and Maintenance<br />
M1 M2 + M3<br />
The I-1020 type can be screwed onto a duct or wall by 4 screws located<br />
inside of the housing, or by an AGRO fi tting in the same manner as<br />
M-series or Roline-L series. Fixing by means of a screw-fi tting is also<br />
possible.<br />
Maintenance<br />
ROTRONIC transmitters require hardly any maintenance. Due to the<br />
excellent long term stability, a calibration interval of one year will be<br />
suffi cient in most cases. However, in some applications, it may be<br />
advisable to perform more than one calibration per year. For detailed<br />
calibration information, please refer to the chapter calibration.<br />
In dusty and otherwise polluted environments, the sensor protection<br />
fi lters require some maintenance. We recommend to have a spare<br />
fi lter ready and to exchange it on site. The replaced fi lter may be<br />
cleaned in the workshop with soap and water. Ultrasonic cleaners may<br />
also be used. Let the fi lter dry thoroughly before re-use.<br />
40<br />
40<br />
ø82<br />
90<br />
101<br />
ø82<br />
90<br />
101<br />
ø15<br />
ø15<br />
~155<br />
~155<br />
18.5<br />
18.5<br />
~43<br />
~43<br />
40<br />
40<br />
207<br />
Probe<br />
Sensors<br />
207<br />
ø15<br />
ø15<br />
~40<br />
~40<br />
Electronic<br />
housing<br />
Sensors<br />
ø82<br />
~103<br />
ø82<br />
~103<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
61
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
62<br />
What is the HygroClip?<br />
HygroClip Introduction<br />
The HygroClip ® is a high quality probe for the measurement of humidity and temperature.<br />
It is used in a wide range of applications including handheld instruments, data-loggers and transmitters. It<br />
provides digital and analogue output signals for both temperature and humidity. The humidity is measured<br />
in the range of 0…100%rh, corresponding to 0…1V; the temperature between either –40…85°C =<br />
-0.4…0.85 V, or –40…60°C = 0…1V. The two versions are distinguishable by different colours of the housing<br />
material. The digital one-wire data signal is ideally suited for OEM applications. The probes may<br />
be adjusted digitally by either software or handheld instruments. Calibration data is stored in an EE-Prom.<br />
Thus, the probes may be used in any ROTRONIC display instrument or transmitter and even in OEM instruments<br />
without the need for on-site adjustment. ROTRONIC offers an exchange service for the HygroClip<br />
probes. Every refurbished HygroClip comes with a new sensor, fully calibrated and with a factory certifi cate.<br />
Make use of the experience of ROTRONIC, and the revolutionary advantage of exchangeability. Being the<br />
fi rst supplyer in the world-wide market, we already satisfi ed the needs of thousands of customers. In continuous<br />
contact with our customers, we expand the advantages of the products to the benefi t of our customers.<br />
Key features<br />
• Simple replacement within seconds<br />
• No on-site adjustment necessary<br />
• Global availability from stock<br />
• Digital output signal<br />
• Analogue interface<br />
• Wide range of supply voltage<br />
OEM applications and advantages<br />
Your benefi ts<br />
� Negligible down-time; reduction of servicing costs<br />
� No specifi c knowledge required<br />
� Available from your local dealer<br />
� High accuracy and interchange ability<br />
� Also suitable for analogue display instruments<br />
� Suitable for almost every OEM instrument<br />
The availability of digital and analogue output signals and the wide supply voltage range of 3.5 to 50 VDC<br />
makes the HygroClip suitable for a wide variety of applications. The application range of 0…100 %rh and<br />
–40 to 85°C is unique.<br />
HygroClip S is the standard-type. However, ROTRONIC is capable of manufacturing customized types according<br />
to your requirements. The HygroClip is ideally suited as an integral part of complete humidity and<br />
temperature measurement systems, such as:<br />
• Display devices<br />
• Process control applications<br />
• Multi channel data loggers<br />
• Handheld instruments<br />
• High precision climate control<br />
• Electronic cabinets<br />
• Incubators and environmental chambers<br />
• Fermentation chambers<br />
• EDP applications<br />
• Gas detection systems & portable instrumentation<br />
• Air-conditioned containers<br />
Section contains<br />
HygroClip Probe<br />
� Standard HygroClip S<br />
� HygroClip S3 for meteorological applications<br />
� Accessories for HygroClip probes
Feature Overview<br />
Universal probe for various applications<br />
Very small size-suitable for<br />
many application<br />
IP-65 protection<br />
Available for standard and<br />
meteorological application<br />
3.5...50 VDC Supply voltage<br />
OEM-types available<br />
HygroClip<br />
Replaceable sensor<br />
protection fi lter<br />
Body fi lled with resin<br />
to avoid condensation<br />
Analogue and digital<br />
interfaces<br />
Sockets with lockring<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
63
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
64<br />
HygroClip S and Accessories<br />
HygroClip S, HygroClip S3<br />
• 100% interchangeable<br />
• 1 digital output and 2 analogue outputs<br />
• ROTRONIC Hygromer humidity sensor 0…100 %rh<br />
• Accuracy ±1.5 %rh<br />
• Long-term stability better than 1 %rh/year<br />
• High precision Pt100 temperature sensor<br />
• HygroClip S3 (white) temperature range<br />
of 0…1V for –40…60°C<br />
Order code:<br />
HygroClip S (anthracite) –40…85 °C = –0.4…0.85 V<br />
HygroClip S3 (white) –40…60 °C = 0…1 V<br />
HygroClip R (standard, refurbished)<br />
HygroClip R3 (white, refurbished)<br />
MOC, MOC3<br />
• Mounting connector for HygroClip S<br />
• 30 cm connecting wires<br />
• Mounting hole 12.7 mm diameter or PG7 thread<br />
• HygroClip connector with bayonet locking ring<br />
• MOC3 in white for HygroClip S3<br />
Order code:<br />
MOC (anthracite)<br />
MOC3 (white)<br />
HygroClip SC04 / SC05<br />
• HygroClip S with miniature cable probe:<br />
Length = 51mm, diameter = 4/5mm, length of probe cable = 2m<br />
• 100% interchangeable<br />
• 1 digital and 2 analogue outputs<br />
• ROTRONIC Hygromer humidity probe 0…100 %rh<br />
• Accuracy ±1.5 %rh / ±0.3K<br />
• Long-term stability less than 1 %rh drift per year<br />
• Temperature sensor Pt100 1/3 DIN<br />
• Probe operating temperature –30 °C…100°C<br />
Order code:<br />
HygroClip SC04 4 mm Ø probe<br />
HygroClip SC05 5 mm Ø probe<br />
MOK, MOK3<br />
Passive extension cables for HygroClip S and S3 (no electronics)<br />
• 1…5m connection cable with stripped wires<br />
• 5 pin connector or DAT05 connection to extend cable length<br />
Active adapter: with integrated amplifi er<br />
• Ranges 0…1V, 0…2,5V, 0…5V, 0…10V<br />
at 0…100%rh and, for example -40…60°C<br />
• Length of connection cable up to 20m<br />
• MOK3 in white for HygroClip S3<br />
Order codes:<br />
see next page
Order codes passive MOK adaptors<br />
Order codes passive adaptors 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
Standard type (anthracite) M O K -<br />
White housing 3-<br />
Cable length: 1 m 0 1<br />
2 m 0 2<br />
5 m 0 5<br />
Stripped wires - X X<br />
Binder 5 pin connector B 5<br />
DAT05 connector (HygroClip-plug) D A T 0 5<br />
Order codes active adaptors 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Remarks<br />
Anthracite housing (Standard type) M O K -<br />
White housing 3-<br />
Cable length: 1 m 0 1<br />
2 m 0 2<br />
5 m 0 5<br />
10 m 1 0<br />
20 m 2 0<br />
Stripped wires X X<br />
Output signal Max. cable length:<br />
0…1 V (min. supply 5.5 V) - 0 0 1 V 2 m<br />
0…2.5 V (min. supply 5.5 V) 0 2 5 V 5 m<br />
0…5 V (min. supply 10 V) 0 0 5 V 10 m<br />
0…10 V (min. supply 15 V) 0 1 0 V 20 m<br />
Temperature range -<br />
0…100°C ( not possible for MOK3-XX) 1<br />
-30…70°C (not possible for MOK3-XX) 2<br />
-40…60°C 3<br />
Load: 1 kΩ/V<br />
HygroWin<br />
• Probe for direct connection to a PC<br />
• Measuring range 0…100 %rh, -40…85°C<br />
• Accuracy ±3 %rh, ±0.5 K<br />
• Comprehensive software with data storage<br />
• Low cost<br />
Order code:<br />
HygroWin<br />
MOK-WIN<br />
• Adapter cable for direct connection of HygroClip S to your PC<br />
• Cable lengths: 1m, 2m, 5m<br />
• Comprehensive software with data storage<br />
Order code:<br />
MOK-01-WIN (with 1 m cable)<br />
MOK-02-WIN (with 2 m cable)<br />
MOK-05-WIN (with 5 m cable)<br />
Note: HygroClip probe must be ordered separately<br />
Reference HygroClips<br />
Reference HygroClips generate a fi xed value for temperature und humidity<br />
in digital format. As the accuracy of digital values is absolute,<br />
the user can calibrate the system with them.<br />
HygroClip S and Accessories<br />
Order code:<br />
HygroClip-S-35RH/15C simulates 35%rh and 15°C (others on request)<br />
HygroClip-S-65RH/25C simulates 65%rh and 25°C<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
65
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
66<br />
HygroClip S and Accessories<br />
HPH Signal Booster<br />
• Allows cable lengths up to 99 m<br />
• Cable length compensation, therefore no measuring errors when<br />
using long cables<br />
• ROV interface (10 mV/ %rh, 10 mV/ °C, 0 %rh, 0°C = 0V)<br />
Ordering information HPH<br />
Order code Description<br />
Technical data of the HPH signal booster<br />
Outputs Humidity 0…100 %rh = 0…1 V<br />
HPH-CG05B5 Booster, 5 m connecting cable with Binder 5 pin connector<br />
HPH-CG99B5 Booster, conn. cable up to 99m selectable, Binder 5 pin conn.<br />
HPH-CG05XX Booster, 5 m connecting cable, stripped wires<br />
HPH-CG99XX Booster, connecting cable up to 99m selectable, stripped wires<br />
Temperature -40…85°C= 0.4…0.85 V<br />
Cable length 5…99 m<br />
Cable compensation Up to 99 m<br />
Connecting cable Open terminations or 5 pin connector<br />
HygroClip Technical data, Order Information<br />
Supply voltage HygroClip 3.5…50 VDC<br />
Current consumption HygroClip Ca. 4 mA<br />
Operating range Humidity /Temperature 0…100 %rh / -40…85°C<br />
Accuracy at 23 °C Humidity /Temperature ±1.5 %rh / ±0.3 K<br />
Output signals HygroClip S Humidity /Temperature 0…100 %rh = 0…1V / -40…85°C = -0.4…0.85V<br />
HygroClip S3 Humidity /Temperature 0…100 %rh = 0…1V / -40…60°C = 0…1V<br />
Digital output signal One Wire DIO<br />
Start up time 2.7s fi rst measurement; 0.7s subsequent<br />
Resolution: Humidity 100 %rh / 12 bit analogue, 16 bit digital<br />
Temperature 250°C/12 bit analogue, 16 bit digital<br />
Adjustment Via PC (EE-Prom) or compatible instrument<br />
Sensors Humidity / Temperature Hygromer AC-1 / Pt100 1/3 DIN<br />
Output load >10 kOhm<br />
Cable length max. 5m<br />
Sensor protection Wire fi lter (max. 20m/s)<br />
Dimensions with MOC 100 x 15 mm<br />
Type of enclosure IP65<br />
Colour HygroClip S Anthracite RAL 7016<br />
HygroClip S3 White<br />
Pin and colour confi guration MOC, MOK, MOK-WIN<br />
MOC, stripped wires MOK B5 Plug HPH B5 Plug MOK-WIN<br />
Term Wire colour Pin Wire colour Pin Wire colour Term D-sub 25 plug<br />
+VDC Green 2 Green 2 Green TXD 2<br />
GND Black 3 Grey and Blue 3 Grey RXD 3<br />
Shield (GND) N/C 3 Shield N/C RTS 4<br />
Temperature Brown 1 1 Brown SG 7<br />
Humidity White 5 5 White DTR 20<br />
DIO Signal Red 4 Yellow<br />
Compensation N/A N/A N/A 4 Yellow
HygroClip<br />
HPH Signal Booster<br />
Dimensional Diagrams<br />
Pin Colour Function<br />
1 brown Temperature<br />
2 green +VDC<br />
3 black GND<br />
4 yellow DIO<br />
5 white rel. humidity<br />
Pin Colour Function<br />
1 brown Temperature<br />
2 green +VDC<br />
3 grey GND<br />
4 yellow Compensation<br />
5 white rel. humidity<br />
T<br />
R<br />
A<br />
N<br />
S<br />
M<br />
I<br />
T<br />
T<br />
E<br />
R<br />
S<br />
67
M<br />
E<br />
T<br />
E<br />
O<br />
R<br />
O<br />
L<br />
O<br />
G<br />
Y<br />
68<br />
In meteorology, the accuracy of the measurements is essential for accurate forecasting and decision-making.<br />
ROTRONIC humidity probes have an excellent reputation for providing reliable results even in the most<br />
demanding conditions where high humidity and low temperatures pervade. Our current product range<br />
offers high performance, a wide range of confi gurations and price levels compatible with any application’s<br />
demands.<br />
Especially with respect to humidity measurement, it is essential to carefully consider correct temperature.<br />
Relative humidity is very temperature dependent. In recognition of this fact, ROTRONIC has developed a<br />
range of enhancements to improve temperature effects and measurement accuracy. These include ventilated<br />
weather and radiation protection shields that provide very good shelter from rain, snow and radiation,<br />
and most importantly, improve the performance of temperature measurement.<br />
Why is correct temperature essential?<br />
In the past, temperature and humidity probes have been built into weather stations, or screens (Stevenson)<br />
usually made of wood and painted white. Despite of the white colour, the screens tended to heat up by<br />
suns radiation, and the deviation from actual temperature could be quite high. Such a deviation obviously<br />
must lead to incorrect measurement of the humidity, because relative humidity is so dependent of temperature.<br />
Example:<br />
Meteorology<br />
Assuming an absolute humidity Q of 5 g/kg, the relative humidity at 20 °C is 34.74 %rh; at 21 °C 32.66 %rh<br />
and at 19 °C 36.97 %rh. Hence, it becomes obvious that a wrong temperature must lead to a wrong humidity<br />
value.<br />
ROTRONIC ventilated weather stations minimise thermal effects and provide for better temperature accuracy,<br />
as the probe is not heating up in the sun. The airfl ow constantly cools the shield, whilst air temperature<br />
is measured at the air inlet.<br />
Key features<br />
• High accuracy and stability<br />
• Probe exchange without tools<br />
• Digital probes<br />
• Ventilated shields<br />
• Compact mounting system for<br />
various probes<br />
• Easy mounting<br />
Your benefi ts<br />
� Reliable measurement data and low maintenance costs<br />
� Saves installation and on-site costs<br />
� No on-site calibration required<br />
� Optimum temperature performance<br />
� One shield for all probe types<br />
� Saves installation and on-site costs<br />
Section contents Page<br />
Ventilated Weather Protection Shields VHTS2 70<br />
Non-Ventilated Weather Protection Shields<br />
Probe adaptors for VHTS2<br />
Analogue Meteorological Probes 71 to 75<br />
Digital HygroClip Probes<br />
MOK Adaptors for HygroClip S
Meteorology Applications<br />
ROTRONIC Weather Station for Temperature and relative Humidity<br />
Snowguns<br />
Weatherstations<br />
BMS/HVAC applications<br />
Agronomical applications<br />
Alpine observation applications<br />
Ice warning systems<br />
M<br />
E<br />
T<br />
E<br />
O<br />
R<br />
O<br />
L<br />
O<br />
G<br />
Y<br />
69
M<br />
E<br />
T<br />
E<br />
O<br />
R<br />
O<br />
L<br />
O<br />
G<br />
Y<br />
70<br />
Weather and Radiation Protection<br />
Ventilated weather/radiation protection<br />
Designed to minimise the infl uence of thermal radiation on humidity<br />
and temperature measurements. Provides optimum protection even in<br />
horizontally driving wind and rain.<br />
Key features<br />
• Easy-to-install protection shield with built-in ventilator<br />
to prevent heating-up of probe and shield<br />
• Special white paint against radiation<br />
• Probe mounting without tools<br />
• Various adaptors for different probes<br />
• 12 V or 24 V fan supply<br />
Order code: Suitable for Fan supply<br />
VHTS2-W-T7/12 MP100 / MP400 probes 12 VDC<br />
VHTS2-W-T7/24 24 VDC<br />
VHTS2-W-C/12<br />
12 VDC<br />
MPH probes<br />
VHTS2-W-C/24 24 VDC<br />
VHTS2-W-M/12<br />
12 VDC<br />
HygroClip with MOK adaptors<br />
VHTS2-W-M/24 24 VDC<br />
VHTS2-W-I/12<br />
12 VDC<br />
HygroClip industrial probe IC3<br />
VHTS2-W-I/24 24 VDC<br />
Adaptors for retrofi tting older shields with a thread in the<br />
lower end of the tube are available.<br />
Order code: Used for probe type:<br />
VHTS-X-MP1 MP100-series<br />
VHTS-X-MP4 MP400-series<br />
VHTS-X-MPH MP100H /MP400H series<br />
VHTS-X-MOK HygroClip probes with MOK adaptors<br />
VHTS-X-IC3 HygroClip IC3 probes<br />
VHTS-X-SCREW Screw for all types; must always be ordered<br />
separately<br />
VHTS2-SP Option Snow protection<br />
Weather and radiation protection shield<br />
with natural ventilation<br />
The naturally ventilated shield is recommended for applications where<br />
the accuracy is less important than in meteorology applications.<br />
Fairly good protection against radiation and precipitation with natural<br />
ventilation.<br />
Suitable for humidity and temperature probes series MP100A,<br />
MP400A, MP100H, MP400H<br />
Protects even against horizontally driving wind and rain up to 68 km/h<br />
Including probe protection tube<br />
Order code: Suitable for:<br />
AC1002/AC1012 MP100A series<br />
AC1003/AC1012 MP400A, MP100H, MP400H<br />
AC1002/AC1012/AC1015 HygroClip S<br />
AC1004 For HygroClip S3C03 probes, HygroClip S+MOK
MP100A with linear voltage output<br />
MP400A with linear current output<br />
Order codes of non-standard types MP100 & MP400<br />
Specifi cation 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />
Example: M P 1 0 1 A - T7 - W 4 W<br />
Output signals: Voltage M P 1 0<br />
Specifi cation:<br />
Humidity: 0…1 VDC = 0…100 %rh<br />
Temperature: -0.4…0.6 V=-40…60°C 1<br />
0…1 VDC= -30…70°C 2<br />
0…1 VDC=-40…60°C 3<br />
Auxiliary Pt100 for 4/4 wire connection 6<br />
Output signals: Current M P 4 0 - -<br />
Common terms for MP100 & MP400<br />
MP100A / MP400A<br />
Key features:<br />
• Accuracy and long term stability<br />
• Resistant to condensation and air-borne pollutants<br />
• Temperature operating range: -40…60°C<br />
• Temperature measurement by direct Pt100 resistance or linear<br />
analogue output<br />
• Cable length compensation circuit; no signal errors for cables up to 100m<br />
• Universal power supply 4.8…30 VDC<br />
Order codes of standard types:<br />
Humidity Range: 0…100 %rh = 0…1 V / 4…20 mA<br />
Order code Temperature range Tuchel plug Cable compensation (see page 75)<br />
MP101A-T4-W4W<br />
Tuchel 4 pin<br />
-0.4…0.6 V = -40…60°C<br />
MP101A-T7-W4W Tuchel 7 pin Yes<br />
MP102A-T4-W4W<br />
Tuchel 4 pin<br />
0…1 VDC = -30…70°C<br />
MP102A-T7-W4W Tuchel 7 pin Yes<br />
MP103A-T4-W4W<br />
Tuchel 4 pin<br />
0…1 VDC = -40…60°C<br />
MP103A-T7-W4W Tuchel 7 pin Yes<br />
MP106A-T7-W4W Direct Pt100 Tuchel 7 pin<br />
MP408A-T4-W4W 4…20 mA = -40…60°C Tuchel 4 pin N / A<br />
MP408A-CGXX-W4W<br />
4…20 mA = -40…60°C N / A<br />
0…20 mA = 0…100 %rh /Pt100, 4 wire 0<br />
4…20 mA = 0…100 %rh /Pt100, 4 wire 1<br />
4…20 mA = 0…100 %rh /2 wire, %rh only 2<br />
4…20 mA= 0…100 %rh/2 wire,/Pt100 4 wire 3<br />
0…20 mA = 0…100 %rh 0…100°C 4<br />
0…20 mA = 0…100 %rh -40…60°C 5<br />
0…20 mA = 0…100 %rh -30…70°C 6<br />
4…20 mA = 0…100 %rh 0…100°C 7<br />
4…20 mA = 0…100 %rh -40…60°C 8<br />
4…20 mA = 0…100 %rh -30…70°C 9<br />
Cable type<br />
Version: A<br />
XX = cable length in m<br />
Integrated plug: Tuchel 4 pin connector T4<br />
Tuchel 7 pin connector T7<br />
Connection cable: PUR cable, grey CG<br />
Cable length: 2m (for example) 02<br />
Cable plug: Cannon 4 pin connector C4<br />
Without plug, stripped wires 00<br />
Sensor protection: Wire fi lter<br />
Operating range: -40…60 °C<br />
Humidity sensor: IN-1<br />
M<br />
E<br />
T<br />
E<br />
O<br />
R<br />
O<br />
L<br />
O<br />
G<br />
Y<br />
71
M<br />
E<br />
T<br />
E<br />
O<br />
R<br />
O<br />
L<br />
O<br />
G<br />
Y<br />
72<br />
Order codes standard types:<br />
Order codes for non-standard probe MP100H & MP400H<br />
Specifi cation Column No. 1 2 3 4 5 6 7 8 9 10 11 12 13<br />
Basic model voltage output MP100H-<br />
Basic model current output MP400H-<br />
Without auxiliary Pt100 0<br />
With auxiliary Pt100, active signal 1<br />
With auxiliary Pt100, passive signal 2 wire 2<br />
With auxiliary Pt100, passive signal 3 wire 3<br />
With auxiliary Pt100, passive signal 4 wire 4<br />
Output signal for MP100H<br />
0…1 V = 0…100 %rh, -40…60°C = -0.4…0.6 V 1<br />
0…1 V = 0…100 %rh, -30…70°C 2<br />
0…1 V = 0…100 %rh, -40…60°C 3<br />
Output signal for MP400H<br />
MP100H / MP400H<br />
MP100H/MP400H with interchangeable<br />
HygroClip probe<br />
Humidity Range: 0…100 %rh = 0…1 V / 0(4)…20 mA, 3 m cable length<br />
Order code Temperature range Remarks<br />
MP100H-010300 -0.4…0.6 V = 40…60°C<br />
MP100H-030300 0…1 V = -40…60°C<br />
Key features:<br />
• Humidity and temperature measurement using interchangeable<br />
HygroClip sensor module (see chapter on HygroClip products)<br />
• Temperature measurement option: accurate measurement by additional<br />
direct Pt100 sensor<br />
• Temperature operating range: -40…60°C<br />
• Current or voltage output signal<br />
MP100H-130300 0…1 V = -40…60°C Auxiliary Pt100, active signal<br />
MP400H-050300 0…20 mA = -40…60°C<br />
MP400H-080300 4…20 mA = -40…60°C<br />
MP400H-180300 4…20 mA = -40…60°C Auxiliary Pt100, active signal<br />
0…20 mA = 0…100 %rh, 0…100°C (max. 60°C) 4<br />
0…20 mA = 0…100 %rh, -40…60°C 5<br />
0…20 mA = 0…100 %rh, -30…70°C 6<br />
4…20 mA = 0…100 %rh, 0…100°C (max. 60°C) 7<br />
4…20 mA = 0…100 %rh, -40…60°C 8<br />
4…20 mA = 0…100 %rh, -30…70°C 9<br />
PUR connection cable (3m standard) 0 3<br />
Maximum 99m 9 9<br />
7 pin Tuchel plug (not for 3/4 wire auxiliary Pt100) T 7<br />
Stripped wires 0 0<br />
Auxiliary temperature sensor Pt100 1/3 DIN - 0 3 D I N<br />
Pt100 1/5 DIN 0 5 D I N<br />
Pt100 1/10 DIN 1 0 D I N
HygroClip S3C03 for agricultural applications<br />
Typical applications include weather stations and data acquisition<br />
systems. Available with 3 m cable, stripped wires<br />
• Precise and stable measurement of temperature and humidity<br />
• Economical price<br />
• Confi gured for outdoor measurements<br />
• Compact dimensions<br />
• Weather protection shield available<br />
• Technical data equal to HygroClip S3, except cable<br />
Measurement range:<br />
HygroClip S3: -40…60°C, 0…100 %rh = 0…1 V<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip S3C03<br />
HygroClip S3<br />
Standard sensor module for humidity and temperature.<br />
A wire mesh fi lter provides sensor protection against dust<br />
and high air velocity.<br />
Dimensions: Ø15 x 100 mm<br />
IP rating: IP65<br />
HygroClip S3 is designed for meteo applications.<br />
Measurement range:<br />
HygroClip S3: -40…60°C, 0…100%rh = 0…1 V<br />
Accuracy: ±1.5 %rh, ±0.3 K (at 23°C)<br />
Order code:<br />
HygroClip S3<br />
HygroClip S3C03<br />
MOK Adaptors for Meteo Applications with HygroClip Probes<br />
The MOK adaptors provide a simple and low cost means<br />
of connecting a HygroClip probe to a 5 V signal processing<br />
device. They are used in conjunction with the weather<br />
protection shields.<br />
Output signal: 0…5 V = 0…100 %rh/-40…60°C<br />
Cable length: 5 m<br />
Supply: min. 5.5 V, max. 26.5 V<br />
Order code:<br />
MOK3-05-XX-005V-3<br />
Other types available on request. (See page 65)<br />
M<br />
E<br />
T<br />
E<br />
O<br />
R<br />
O<br />
L<br />
O<br />
G<br />
Y<br />
73
M<br />
E<br />
T<br />
E<br />
O<br />
R<br />
O<br />
L<br />
O<br />
G<br />
Y<br />
74<br />
Technical Data<br />
Technical data, MP100A, MP400A, MP100H, MP400H<br />
Series MP100A MP100H MP400A MP400H<br />
Protection (IP-rating) IP65<br />
Option: humidity only (2 wire, 3 wire) Yes N/A Yes N/A<br />
Output signal Voltage Current<br />
Supply voltage 4.8…30 VDC Min. 8 VDC +0.02 x load<br />
Power consumption:<br />
4 wire with current output N/A 50 mA 45 mA<br />
2 wire with current output N/A 20 mA<br />
4/5 wire with voltage output 6 mA 10 mA N/A<br />
3/4 wire with voltage output 3.5 mA 10 mA N/A<br />
Load >1000 Ω
Dimensional Diagrams MP100A / MP400A<br />
30<br />
25<br />
210<br />
40,5<br />
Dimensional Diagrams MP100H / MP400H<br />
Pinning of Tuchel Plugs for MP100 & MP400 Series<br />
Dimensional Diagrams<br />
MP100A-T7 MP100A-CG<br />
TUCHEL PLUG 7P<br />
HOUSING: WHITE<br />
Cable Length Compensation<br />
The integrated cable length compensation allows the use of a connection<br />
cable up to 99 m long, without an adverse affect on measurements.<br />
The additional “0” cable wire is connected according to the<br />
diagrams shown.<br />
The combination of ROTRONIC instruments with ROTRONIC cables<br />
includes the cable length compensation facility as standard.<br />
The connection from probe to display instrument consists of a 5 core<br />
cable, where the shielding may also be used for the common earth.<br />
The “0” cable compensation is connected to the common earth<br />
“GND” at the display instrument. It is possible to use the probe with<br />
a non-ROTRONIC instrument, such as a data-logger, chart recorder or<br />
controller and retain the compensation, by connecting the cable compensation<br />
“0” to the common earth “GND” of the termination point<br />
(the load).<br />
The cable compensation “0” can be connected with the common earth<br />
“GND” at the plug, if a 5core cable is extended by a 5core cable. If this<br />
is terminated by a 4pin plug, in this case the cable compensation is<br />
effective in the 5 core cable up to the 4pin plug.<br />
Probes with integrated 4 pin connector:<br />
The cable compensation is effective up to the connector.<br />
52<br />
7<br />
PG7 WITH KINK PROTECTION<br />
HOUSING: WHITE<br />
MP100H / MP400H /-0 MP100H /MP400H / 1…4<br />
Tuchel T4 Tuchel T7 MP100 Tuchel T7 Auxiliary Pt100<br />
252<br />
40,5<br />
M<br />
E<br />
T<br />
E<br />
O<br />
R<br />
O<br />
L<br />
O<br />
G<br />
Y<br />
75
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
76<br />
Water Activity<br />
The measurement of Water Activity, or Equilibrium Relative Humidity, as it is sometimes known, is a key<br />
parameter in the quality control of any moisture sensitive product or material.<br />
ROTRONIC have designed and manufactured instruments for the measurement of Water Activity for over 30<br />
years. Our product range is based on our comprehensive application experience, which when combined with<br />
the very latest digital technology and software, offers the user the ideal combination of features, performance<br />
and competitive pricing.<br />
Water activity Contaminant<br />
a w = 0.91…0.95 most bacteria<br />
a w = 0.88 most yeast<br />
a w = 0.80 most mildew<br />
a w = 0.75 halophile bacteria<br />
a w = 0.70 osmiophile yeast<br />
a w = 0.65 xerophile mildew<br />
Key features<br />
Why is water activity measured?<br />
Water activity defi nes the active part of a product’s moisture content,<br />
or ‘free’ water. It infl uences the microbiological, chemical and enzymatic<br />
stability of perishable products such as foods, grain and seeds.<br />
The table shows typical growth thresholds below which the specifi ed<br />
contaminant cannot replicate, and therefore spoil the product. Control<br />
of water activity therefore has a signifi cant impact on shelf life.<br />
For similar reasons, water activity is equally relevant in the pharmaceutical<br />
industry where it also provides useful information regarding<br />
properties such as the cohesion of tablets, agglomeration of powders,<br />
and adherence of coatings.<br />
• Wide operating range<br />
• Aw Quick mode<br />
• High measurement precision<br />
• Long Term Stability<br />
• Interchangeable measurement stations<br />
• Multi channel display units<br />
• Validated PC analysis software<br />
Section contents: Page<br />
HygroLab Laboratory Display Units/Analysers 80<br />
� Digital technology<br />
� Multiple probes inputs<br />
� Networkable<br />
� Validated, easy to use software<br />
HygroPalm AW Portable Analysers 81<br />
� Digital technology<br />
� Integrated AW quick function<br />
� Measurement sets<br />
HygroClip water activity stations and probes 82 to 83<br />
� Wide range of measurement options to suit any application<br />
� Digital calibration<br />
� 100% interchangeable without adjustment<br />
Accessories for Water Activity measurement 84<br />
� Sample holders<br />
� Disposable sample containers<br />
Your benefi ts<br />
Water Activity Theory and reference, Technical Data 85 to 87<br />
� What is water activity?<br />
� Water activity or moisture content?<br />
� Suitable for any product or application<br />
� Results in 4…6 minutes<br />
� Reliable data every time<br />
� Reduced maintenance and calibration<br />
� Simple calibration & maintenance<br />
� 2 or 4 simultaneous measurements<br />
� Secure data acquisition and data<br />
handling
Petfoods – its important our<br />
best friends eat well!<br />
Horticulture –<br />
seeds – preven -<br />
tion of germination<br />
during storage<br />
Pharmaceutical<br />
industry; tablet and<br />
powder ERH<br />
Building materials<br />
Water Activity Applications<br />
Tobacco industry<br />
Bakery products<br />
Food industry – cheese<br />
Food<br />
industry –<br />
meat products<br />
Paper manufactur ing,<br />
converting, storing<br />
and printing<br />
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
77
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
78<br />
Introducing Water Activity Products<br />
The ROTRONIC range of water activity instruments uses the latest digital technology to introduce new levels<br />
of measurement performance, application fl exibility and new features. Multiple probe inputs, PC based data<br />
handling, instrument networking, software based calibration, and interchangeable measurement stations<br />
are just some of the features included in our latest range.<br />
The humidity sensors used in our measurement probes have an enviable reputation for precision and reliability.<br />
Their performance is now augmented by software based analysis modes and new developments in<br />
mechanical probe design. These combine to achieve consistently high levels of performance with signifi -<br />
cantly reduced sampling times, and extremely cost effective pricing.<br />
Our range of water activity measurement stations and probes feature the HygroClip digital signal processing<br />
technology, including signal transmission and calibration. This produces a signifi cant gain in accuracy,<br />
data integrity and stability, as well as convenient features such as simplifi ed PC based confi guration, data<br />
acquisition and calibration using easy-to-use Windows software.<br />
Bench top display instrumentation is also now complemented by a handheld portable solution; using the<br />
same high precision measurement technology to ensure consistently precise results and full interchangeability<br />
between laboratory and production data.<br />
HygroLab<br />
HygroLab is a range of three high quality benchtop display instruments<br />
for the laboratory environment. HygroLab 1 is a cost effective<br />
2 channel instrument with measurements displayed in %rh and °C<br />
units. HygroLab 2 has 4 probe inputs plus the option to display measurements<br />
in aw units, and an RS232 interface for display, data acquisition<br />
or confi guration.<br />
HygroLab 3 is the fl agship of our range, with all the features of the<br />
HygroLab 2, plus the addition of HygroData Quick which has specialised<br />
features specifi c to water activity analysis including rapid equilibrium<br />
in typically 5 minutes or less, plus automatic capture of fi nal<br />
values.<br />
HygroPalm AW1<br />
In some instances, the ability to measure water activity in production<br />
or storage environments can be very useful. For example, when bulk<br />
deliveries are received, they can be checked on receipt to make sure<br />
that supply specifi cations are met.<br />
The new HygroPalm AW has been specially confi gured to offer the key<br />
functions of the HygroLab 3, including HygroData Quick in a portable<br />
package<br />
Aw Quick<br />
Aw Quick is advanced software for water activity analysis which is<br />
either integrated within the HygroLab 3 or HygroPalm AW display instruments,<br />
or can be run on a PC connected to a HygroLab.<br />
Aw Quick provides the user with fi nal measurement results in typically<br />
fi ve minutes or less, or can run a conventional water activity analysis<br />
with automatic detection and capture of equilibrium values.
LC Display:<br />
Includes probe input indicator,<br />
three line numeric display<br />
MENU:<br />
Press this key to activate<br />
the functions menu<br />
Up to 32 HygroLab 2 + 3<br />
instruments can be<br />
networked together.<br />
128 measurement probes<br />
controlled by one PC!<br />
HygroLab Feature Overview<br />
UP/DOWN:<br />
Changes displayed probe and<br />
navigates.<br />
Multiple inputs:<br />
4 probes simultaneously<br />
ENTER:<br />
Confi rms selection<br />
ON / Off<br />
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
79
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
80<br />
HygroLab<br />
HygroLab 1:<br />
Basic two-probe bench top indicator of %rh & °C.<br />
Key features:<br />
• Accepts 2 ROTRONIC digital or analogue probes<br />
• Display of %relative humidity and temperature<br />
• Software-based probe calibration (1-point or multi-point)<br />
Order code:<br />
HygroLab 1<br />
HygroLab 2:<br />
Bench-top display instrument with four probe inputs, display in<br />
Aw units, %hr and °C.<br />
Key features:<br />
• Accepts 4 ROTRONIC digital or analogue probes<br />
• Full psychrometric calculations<br />
• Software-based probe calibration (1-point or multi-point)<br />
• Can use one of the four probes as a reference to perform a<br />
1-point adjustment of the other probes<br />
• RS232 interface for PC running HW3 software<br />
• RS485 interface for networking instruments together<br />
• Optional analogue outputs<br />
• Optional: Accelerated water activity measurement with up to<br />
4 probes: (AwQuick mode): allows the measurement of most<br />
products in typically 5 minutes; requires HW3 software<br />
Order code:<br />
HygroLab 2<br />
HygroDATA Lab Software HW3 and RS cable<br />
HygroData Quick: HygroQuick function<br />
HygroLab 3<br />
Water activity analyser with four probe inputs and integrated AW<br />
Quick.<br />
Key features:<br />
• Accelerated water activity measurement with up to 4 probes:<br />
(AwQuick mode): allows the measurement of most products in typically<br />
5 minutes<br />
• Full equilibration measurement with up to 4 probes (Standard<br />
mode) with automatic detection of equilibrium conditions<br />
• Accepts 4 ROTRONIC digital or analogue probes<br />
• Full psychrometric calculations<br />
• Software-based probe calibration (single-point or multi-point)<br />
• Can use one of the four probes as a reference to make a 1-point adjustment<br />
of the other probes<br />
• RS232 interface for PC running HW3 software<br />
• RS485 interface for networking instruments together<br />
Order code:<br />
HygroLab 3<br />
HW3 Software<br />
The HW3 software package has a comprehensive range of functions<br />
which are compatible with the HygroLab.<br />
Order code:<br />
HygroDATA Lab Software HW3 and RS cable<br />
See chapter HW3 Software for full information.
HygroPalm AW1<br />
The HygroPalm AW1 is a portable instrument specifi cally confi gured<br />
for the measurement of water activity. It includes many of the advanced<br />
features of the HygroLab, including the Aw Quick mode for<br />
results in 4–6minutes. This makes it perfectly suited for users who<br />
wish to perform water activity analysis in production, goods receiving<br />
or storage areas where portable instrumentation is more convenient.<br />
Key features:<br />
• Accelerated water activity measurement:<br />
(AwQuick mode): allows the measurement of most products in typically<br />
5 minutes<br />
• Full equilibration measurement (Standard mode) with automatic<br />
detection of equilibrium conditions<br />
• Single digital probe input<br />
• Single or multiple point digital calibration directly with the keypad<br />
• Aw display units<br />
• Available as a set with carry case<br />
• Optional docking station for battery charging or mains operation<br />
Order code:<br />
HygroPalm AW1<br />
PD1 Docking Station for AW1 with connector<br />
for AC1207 power adaptor<br />
AC1207 Power adaptor<br />
HygroPalm AW Sets<br />
For on-site measurements, or for the fi rst time user, the HygroPalm<br />
Aw sets are a perfect solution. The sets are supplied in a lightweight<br />
but tough ABS carry case, and include all the items required to perform<br />
measurements and maintain the instrument.<br />
HygroPalm AW<br />
The difference between the two sets is the size of the sample holder<br />
and sample containers. AW1-Set/14 includes the WP14/PS14 for sample<br />
sizes such as tablets, powders, seeds, powdered spices, tea etc.<br />
AW1-Set/40 includes the WP40/PS40 for larger samples such as petfood,<br />
ore, nuts, beans, etc. (see also “Accessories & Consumables” for<br />
more information)<br />
HygroPalm HygroPalm<br />
AW1-Set/14 AW1-Set/40 Description<br />
HygroPalm AW1 HygroPalm AW1 Handheld display instrument<br />
AW-DIO AW-DIO Measurement probe<br />
WP-14-S WP-40 Sample holder<br />
PS-14 PS-40 13/6 sample container<br />
EA35-SCS EA35-SCS 35 %rh calibration standards<br />
EA80-SCS EA80-SCS 80 %rh calibration standards<br />
EA50-SCS EA50-SCS 50 %rh calibration standards<br />
EA10-SCS EA10-SCS 10 %rh calibration standards<br />
AC1119 AC1119 Case<br />
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
81
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
82<br />
Water Activity Probes<br />
Based on HygroClip digital electronics technology for high perfor mance and convenient digital calibration,<br />
our selection of probes will suit almost any application. All water activity stations and probes incorporate<br />
temperature measurement as standard.<br />
AW-DIO Water Activity Station<br />
The AW-DIO is a water activity measurement station which measures<br />
over the range 0…1 aw (0…100 %rh) and provides a digital output<br />
signal to interface with HygroLab and HygroPalm Aw display units.<br />
Digital calibration can be performed using the display instrument.<br />
Minimised internal volume of the sensor chamber ensures fast equilibrium<br />
with all products, and an all metal construction ensures good<br />
temperature stability during measurements, with stainless steel used<br />
on all critical surfaces. Sample holders, sample containers and a sealing<br />
mechanism are detailed in accessories.<br />
AW-DIO is now the single option for water activity measurements in<br />
a sample chamber. It replaces previous products such as the WA-14,<br />
WA40, AS-ST, and WAO. It also has superseded the AWVC model<br />
with integrated air circulation fan. Through our continuous research<br />
and development program we have been able to match or better the<br />
equilibrium performance of the ventilated system with our new Aw<br />
specifi c sensor, and improved mechanical design.<br />
Measuring range: 0...100 %rh (0...1 aw), 5...50°C<br />
Order code:<br />
AW-DIO<br />
Dimensions of AW-DIO probe<br />
Temperature Control<br />
Stable temperature during measurements can be very important with<br />
some products in order to obtain precise results. Our measurement<br />
probes are designed with a high thermal mass to prevent variations<br />
during measurement, but for the highest precision or where laboratory<br />
temperature changes, temperature control solutions are avail able.<br />
Please contact ROTRONIC or your local distributor for more information.
HygroClip SP05 Insertion Probe<br />
For direct measurement of water activity in bulk samples. Applications<br />
include tablets, gel capsules, grain and plastic granules. HygroClip<br />
SP05 features a precisely engineered 5 mm-diameter stainless steel<br />
probe with laser cut slots to allow the humidity measurement sensor<br />
exposure to water vapour in the air (not suitable for powders or dusty<br />
products).<br />
Measuring range: 0...100 %rh (0...1aw), -40...85°C<br />
Order code:<br />
HygroClip SP05 5 mm insertion probe<br />
MOK-02-B5 Cable, HygroClip SP05 to<br />
HygroLab/HygroPalm Aw1<br />
Ø: 5 mm Probe length: 200 mm Cable: 2 m<br />
HygroClip HP28 Insertion Probe<br />
For direct measurement of water activity in bulk samples.<br />
Applications include powders, granules, grain and cereals. HygroClip<br />
HP28 features a robust 10 mm-diameter stainless steel probe with replaceable<br />
sintered steel dust fi lter to allow the humidity measurement<br />
sensor exposure to water vapour in the air or product.<br />
Measuring range: 0...100 %rh (0...1aw), -40...85°C<br />
Order code:<br />
HygroClip HP28 10 mm insertion probe<br />
MOK-02-B5 Cable, HygroClip SP05 to<br />
HygroLab/HygroPalm Aw1<br />
Ø: 10 mm Probe length: 280 mm Cable: 2 m<br />
HygroClip SC04 /SC05<br />
Suitable for air measurement in small spaces thanks to the 5 mm probe<br />
diameter and compact dimensions. For customers measuring water<br />
activity, the HygroClip SC05 is useful for the measurement of humidity<br />
and temperature in packaging, storage containers and incubators.<br />
Measuring range: 0...100 %rh (0...1aw), -40...85°C<br />
Order code:<br />
HygroClip SC04 4 mm cable mounted probe<br />
HygroClip SC05 5 mm cable mounted probe<br />
MOK-02-B5 Cable, HygroClip SP05 to<br />
HygroLab/HygroPalm Aw1<br />
Ø: 5 mm Cable: 2 m<br />
Water Activity Probes<br />
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
83
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
84<br />
Accessories and Consumables<br />
Sample Holders<br />
Stainless steel sample holders that are precisely engineered to work<br />
with the AWC/VC water activity chamber. Two sizes are available,<br />
WP14-S is for small product samples (14mm depth) and WP40 for<br />
larger materials (40mm depth). Both products provide excellent sample<br />
containment and optimum temperature stability. WP-40TH has an<br />
integrated water jacket for temperature control. Recommended temperature<br />
control level max. ±5°C from ambient temperature.<br />
Order code:<br />
WP-14-S for PS14<br />
WP-40 for PS14 and PS40<br />
WP-40TH with water jacket for temperature control<br />
Sample Containers<br />
Disposable sample containers that ensure the optimum sample volume<br />
is introduced into the WP-14-S and WP-40. They help to prevent<br />
the sample holders from coming into direct contact with product being<br />
tested, and hence prevent soiling or cross contamination. The<br />
sample containers also provide a convenient means of collecting and<br />
storing samples.<br />
Order code:<br />
PS14 Pack 100 sample containers to suit WP-14-S<br />
PS40 Pack 100 sample containers to suit WP-40<br />
Clamp Sealing Mechanism<br />
In some circumstances additional mechanical sealing of the AW measurement<br />
station and sample holder is required to prevent external<br />
conditions infl uencing the sample. The AW-KHS provides a strong<br />
mechanical seal, and is compatible with all available sample holders.<br />
(Only in combination with WP-40 and WP-40TH)<br />
Order code:<br />
AW-KHS<br />
Humidity Standards<br />
The ROTRONIC SCS certifi ed humidity standards provide a reference<br />
value against which instruments can be calibrated. They are supplied<br />
in packs of 5, complete with certifi cates of calibration. They can be applied<br />
to all probe types, with Water Activity probes using sample holders<br />
and containers, for other probes (HygroClip SP05, SC04 and HP28)<br />
a calibration device is required.<br />
Order code:<br />
EA-xx-SCS Where xx = 00, 05, 10, 11, 20, 35, 50, 65, 75,80 & 95%rh<br />
Calibration Devices<br />
Provide a sealed environment around probes where ROTRONIC humidity<br />
standards can be applied.<br />
Order code:<br />
ER-05 for 5 mm diameter probes (HygroClip-SP05 / SC05)<br />
ER-15 for 15 mm diameter probes (HygroClip S)<br />
EGL for 10 mm diameter probes (HygroClip HP28)<br />
Aw-DIO can be calibrated in combination with the sample holder and<br />
container (WP-14/PS14).
What is Water Activity?<br />
Water Activity Explained<br />
Water Activity (aw) is the relative humidity which is reached at equilibrium in a sealed container in which<br />
a hygroscopic product has been placed, but expressed on a scale of 0…1. Water Activity measurement is<br />
most commonly used in the food industry, where it is used to determine shelf life and quality.<br />
What is Equilibrium Relative Humidity?<br />
Equilibrium Relative Humidity (ERH) is the value of relative humidity into which a Hygroscopic product can<br />
be placed where no net exchange of moisture between the product and the surrounding environment can<br />
take place. It is expressed on a scale of 0…100%. ERH is typically used in the paper and pharmaceutical<br />
industries, but can be applied to almost any product that is sensitive to moisture, or where the presence of<br />
moisture can effect product handling.<br />
Aw or ERH?<br />
Both aw and ERH are an expression of the amount of free water vapour present on a product, both at its<br />
surface and within its structure, and are practically the same measurement expressed in a slightly different<br />
way. Throughout this data sheet we will refer to Water Activity, but this can be interchanged with ERH.<br />
Where specifi ed, ROTRONIC products offer the user the possibility to select display units of aw or %rh.<br />
What is Moisture Content?<br />
Moisture content, when referring to a solid material, is an expression of the percentage of the materials<br />
weight which is water (both in liquid or gaseous phase); usually referred to as ‘percent moisture content’.<br />
This term is widely used in many areas of industry.<br />
Water Activity or Moisture Content?<br />
There is frequently confusion between Water Activity and moisture content measurements. In many industries,<br />
moisture content is used to control the amount of water present in a product for quantitative reasons.<br />
For example, if a product is sold by weight, controlling its moisture content may be useful in maintaining<br />
product quality, but can also impact on profi tability (more water equals more profi t).<br />
Water activity is more signifi cant for qualitative considerations such as product stability shelf life (e.g.<br />
microbiological & enzymatic stability, aroma retention), handling characteristics (e.g. agglomeration of<br />
powders), physical properties (e.g. dimensions of paper) and chemical stability (e.g. pharmaceuticals).<br />
Sorption Isotherm<br />
Water Activity and Moisture Content can be related by a graph<br />
called a Sorption Isotherm (see diagram) so if the user has the ability<br />
to measure both parameters, the relationship can be defi ned<br />
and each parameter derived from the other (interpolation).<br />
In practice, the Sorption Isotherm may be impractical to use, because,<br />
not only does the relationship between aw and moisture<br />
content change with temperature of measurement, but also any<br />
variation in the material composition has a modifying effect. This<br />
is especially the case with products of natural origin such as food<br />
and paper. The user should therefore decide which parameter of<br />
measurement is best suited to their product and processes. For<br />
quality control purposes moisture content limits are easily converted<br />
to Water Activity limits by very simple comparative tests.<br />
Water Activity offers a non-destructive, easy to use measurement<br />
in a wide range of convenient confi gurations for both laboratory<br />
and on-site use.<br />
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
85
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
86<br />
Adr. 0 Adr. 1 Adr. 2 Adr. 31<br />
WP-14-S WP-40<br />
WP-40TH<br />
Schematics and Diagrams<br />
Networking (HygroLab 2 and 3)<br />
The optional HW3 software offers a simple means of quickly establishing a PC based network. Up to 32<br />
HygroLab indicators and/or HygroFlex transmitters can be connected together on a network. Any instrument<br />
can be used either as a slave or a master, without special confi guration. Each unit must be given a<br />
unique network address with the HW3 software (0 to 31). The master is automatically the unit that is connected<br />
to the COM port of the PC by means of the RS232 port. See Connectors – RS232 / RS485 for details.<br />
RS232 (3 wires)<br />
max. 12 m<br />
Dimensional diagrams<br />
RS485 (2 wires)<br />
max. 1000 m<br />
~160<br />
AW-KHS<br />
~220<br />
200 x 120
Technical Data<br />
Key Features HygroLab 1 HygroLab 2 HygroLab 3 HygroPalm Aw 1<br />
Probe Connections 2 4 4 1<br />
PC Interface No RS232/485 RS232/485 No<br />
Networking No Up to 32 instruments using RS485 No<br />
Aw Quick mode No With HygroData Integrated & with Integrated<br />
Quick (Software HygroData-LAB<br />
and PC) (HW3 Software<br />
and conn. cable)<br />
Calibration functions 1 point Using keypad Using keypad Using keypad<br />
with keypad or PC; 1 or or PC; 1 or 1 point %rh (aw), °C/F,<br />
4 point %rh (aw), 4 point %rh (aw), 4 point %rh,<br />
2 point °C/h 2 point °C/F 2 point °C/F<br />
Display units %rh, °C, °F, %rh, aw, °C, °F, calculated parameters aw, °C, °F,<br />
Calculated parameters None Dew-point, wet-bulb, None<br />
enthalpy, mixing ratio,<br />
moisture content,<br />
partial water vapour pressure,<br />
saturation water vapour pressure<br />
Audible signal<br />
upon measurement end: No No Yes No<br />
Accuracy at 23°C ±1.5 %rh, ±0.3 K ±1.5 %rh, ±0.015 aw, ±0.3 K<br />
Repeatability Better than 0.5 %rh Better than 0.5 %rh/0.005 aw, 0.1°C/0.2°F<br />
0.1°C/0.2°F<br />
Sensors Probe dependent<br />
Instrument<br />
operating range 0…99 %rh, -10…60°C (14…140°F)<br />
Display Type Liquid Crystal 3 line alphanumeric<br />
Trend indicator No Yes Yes Yes<br />
Display resolution 0.1 %rh/0.1°C/F 0.1 %rh, 0.001 aw, 0.1°C/F, 0.01 calculated value<br />
Housing Aluminium, 220 x 170 x 55 mm ABS<br />
Power 9 V Power adapter, +tip PP3 battery, or 9 V<br />
power adapter +tip<br />
through PalmDock<br />
CE Conformity EMV: EN50081-2 EN/EN50082-2<br />
Note:<br />
Many older products have been replaced by new ones, that perform better.<br />
ROTRONIC will continue to support the old products as long as possible.<br />
Our customers are used to the fact, that we still maintain probes and instruments that are over 20 years old.<br />
We will continue this tradition for the benefi t of our customers who will thus always get the best price / performance<br />
ratio and have their investments secured.<br />
W<br />
A<br />
T<br />
E<br />
R<br />
A<br />
C<br />
T<br />
I<br />
V<br />
I<br />
T<br />
Y<br />
87
T<br />
E<br />
M<br />
P<br />
E<br />
R<br />
A<br />
T<br />
U<br />
R<br />
E<br />
88<br />
Temperature Measuring <strong>Instruments</strong><br />
Temperature Measuring <strong>Instruments</strong> T1, T51, T55<br />
The measurement of temperature is essential in many production processes, storage, drying and transportation<br />
applications, and even at home for a comfortable climate. In many countries, the law demands that<br />
in the food- and pharmaceutical industry temperature is controlled and recorded. ROTRONIC offers handheld<br />
instruments and transmitters for this purpose, which are used in the pharmaceutical industry, as well<br />
as in dairy food chains, the transportation sector, warehouses etc. The easy handling and installation, and<br />
the wide measuring ranges make them suitable for most applications. The M-series and Roline-L-series<br />
transmitters are also available for temperature measurement only.<br />
Handheld measuring instrument T1 for Pt100 probes<br />
• Measuring range: -100…500°C<br />
• Plug in Pt100 probes, see next page<br />
• Automatic range adjustment at 200°C<br />
• Large, 3 1 /2 digit LCD display<br />
• DATA HOLD<br />
• °C/°F selectable on PCB by jumper<br />
• Adjustable<br />
Order code:<br />
T1<br />
Handheld measuring instrument T51<br />
• Interchangeable thermocouple type K, see page 90<br />
• Max. display<br />
• DATA HOLD<br />
• Impact protection<br />
• Includes one wire probe<br />
• °C/°F switch selectable<br />
Order code:<br />
T51<br />
Handheld measuring instrument T55<br />
• 2 interchangeable thermocouples type K or J, see page 90<br />
• Min/max display<br />
• DATA HOLD<br />
• Temperature difference T1-T2<br />
• Stopwatch function<br />
• Impact protection<br />
• Includes two wire probes<br />
• °C/°F switch selectable<br />
Order code:<br />
T55<br />
TI Transmitter for Pt100 probes<br />
• Transmitter for the most demanding industrial processes<br />
• IP65 housing<br />
• Linear output signals<br />
• Probe connector on housing<br />
• Connectable Pt100 probes, see next page<br />
• Optional digital display<br />
Order code:<br />
see table on page 91
Temperature Measuring Probes Pt100 Probes<br />
Order code Probe type Specifi cation Material Cable All Probes with Binder 4 pin plugs<br />
AC 1900 Rod Type, -70...300°C DIN 1.4401 N/A<br />
100 x 3 mm Pt 100 Class A<br />
AC 1901 Rod Type -70...500°C DIN 1.4401 N/A<br />
250 x 3 mm Pt 100 Class A<br />
AC 1902 Penetration Type -70...500°C DIN 1.4401 1m<br />
250 x 3 mm Pt 100 Class A PUR<br />
Tmax Cable: spiral<br />
80°C<br />
AC 1903 Cable Type -70...500°C DIN 1.4401 2m<br />
200 x 6 mm Pt 100 Class A Silicon<br />
Tmax Cable: straight<br />
180 °C<br />
AC 1904 Cable Type -50...120°C DIN 1.4401 2m,<br />
50 x 6 mm Pt 100 Class A Thermoplast<br />
Tmax Cable: straight<br />
120°C<br />
AC 1905 Surface Type -70...300°C Brass 2m<br />
40 x 10 x 5 mm Pt 100 Class A Silicon<br />
Tmax Cable: straight<br />
180°C<br />
AC 1907 Surface Type, 0...200°C DIN 1.4401 1m<br />
angle 90 °, Pt 100 Class B PUR<br />
250/60 x 5 mm Tmax Cable: spiral<br />
80°C<br />
AC 1908 Handheld, for -50...200°C DIN 1.4401 1m<br />
measurement in air Pt 100 Class A spiral<br />
250 x 5 mm Tmax Cable:<br />
80°C<br />
AC 1909 Rod, for -50...200°C DIN 1.4401 2m<br />
measurement in air Pt 100 Class A Silicon<br />
100 x 5 mm Tmax Cable: straight<br />
180°C<br />
AC1910 Screw in, -70...500°C DIN 1.4401 N/A<br />
1⁄4" G, 30 mm Pt 100 Class A<br />
Tmax Cable:<br />
180°C<br />
AC 1911 Screw in, -70...500°C DIN 1.4401 N/A<br />
1⁄4" G, 50 mm Pt 100 vA<br />
Tmax Cable:<br />
180°C<br />
AC 1912 Screw in, -70...500°C DIN 1.4401 N/A<br />
1⁄4" G, 100 mm Pt 100 Class A<br />
Tmax Cable:<br />
180°C<br />
AC 1913 Foil 0...200°C Silicon 1m<br />
25 x 32 x 1 mm Pt 100 Class A<br />
Pt100 Probes<br />
30<br />
ø4.5<br />
100<br />
40<br />
1/4"G<br />
10<br />
200x5<br />
ø5<br />
30 50 L<br />
1/4"G<br />
ø5<br />
30 50 L<br />
1/4"G<br />
ø5<br />
30 50 L<br />
25<br />
32<br />
5<br />
1<br />
60x5<br />
T<br />
E<br />
M<br />
P<br />
E<br />
R<br />
A<br />
T<br />
U<br />
R<br />
E<br />
89
T<br />
E<br />
M<br />
P<br />
E<br />
R<br />
A<br />
T<br />
U<br />
R<br />
E<br />
90<br />
Temperature Measuring <strong>Instruments</strong><br />
Order Code Probe Type Specifi cation Useed for All Probes<br />
with K-type plug<br />
44.10.1885 TCP-A -50...800°C Measuring in the<br />
Penetration probe K-element, food industries in<br />
150 x 4 mm semi-compact material<br />
such as jelly etc.<br />
44.10.1890 TCP-B -50...800°C Measuring in liquids<br />
Immersion probe K-element and jellies etc.<br />
200 x 2 mm<br />
44.10.1486 RO40017 -50...480°C Multi purpose probe<br />
Universal probe K-element,<br />
28 x 57 mm<br />
44.10.1900 TCP-F -50...800°C Fast measuring<br />
Surface probe K-element on surfaces<br />
150 x 10 mm<br />
44.10.1475 S533 -50...250°C For measuring in air,<br />
wire probe K-element liquids etc.<br />
1000 x 1.3 mm<br />
Accessories<br />
AC 2001 Screw-in measuring-sleeve for 3 mm<br />
probes; Thread 1⁄4" G<br />
Immersion depth 50 mm<br />
AC 2002 Screw-in measuring-sleeve for 3 mm<br />
probes; Thread 1⁄4" G<br />
Immersion depth 100 mm<br />
HygroClip TH100-B5 Adaptor for all Pt100 probes<br />
for HygroPalm 2/3 & HygroLab instruments<br />
with Binder 5-pin plug
Order Code TI Temperature Transmitters<br />
Temperature Transmitters<br />
Order code 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />
Example: TI1 - 2 - B 4 - 4 A 1 X - 1 4<br />
Transmitter Series TI1 -<br />
Power supply: 230 VAC 0<br />
115 VAC 1<br />
4…20mA loop power (Umin =10 V+0.02 x load) 2<br />
24 VAC galvanically separated 3<br />
10(15)…35 VDC/12…24 VAC 8<br />
PT100 connector Binder 4-pin B 4<br />
Output signal 0…20 mA 0 A<br />
4…20 mA 4 A<br />
0…1 V 1 V<br />
0…5 V 5 V<br />
0…10 V 0 V<br />
Cable connection 1 M16 Terminals 1<br />
2 M12 Terminals 2<br />
Tuchel plug 7-pin 7<br />
Display None X<br />
With Display D<br />
Temperature Range = 0…50°C 1 0<br />
Output signal -30…70°C 1 1<br />
0…100°C 1 4<br />
-40…60°C 1 9<br />
0…200°C 2 0<br />
-50…150°C 2 1<br />
-100…100°C 2 2<br />
-100…200°C 2 3<br />
-100…300°C 2 4<br />
Technical Data Temperature Measuring <strong>Instruments</strong><br />
Series T1 T51 T55 TI-Series<br />
Instrument type Handheld Transmitter<br />
IP Protection rating IP50 IP-50, rubber impact protection IP65<br />
Power supply AC/DC/mains<br />
9 V PP3 alkaline battery Yes No<br />
10…35 VDC/24 VAC N/A Option<br />
115 /230 V AC N/A Option<br />
Galvanic separation N/A Option<br />
4…20 mA loop power<br />
(Umin =10 V+0.02 x load) N/A Option<br />
Number of Probe inputs 1 1 2 1<br />
Connection type of probe 3-wire 2-wire 3-wire<br />
Operating range electronics 0…50°C / 0…90%rh -20…50°C<br />
Measuring range withPt100 -100…500°C N/A N/A<br />
with K-Type N/A -50…1300°C -200…1370 °C Probe dependent<br />
with J-Type N/A N/A -200…760 °C<br />
Accuracy at 23°C Pt100 ±0.1 K ±0.3 K<br />
1000°C N/A ±0.5% +1 K ±0.3% +1 K N/A<br />
Reproducibility 0.1 K<br />
Display 31⁄2 Digits 4 Digits Option, not for<br />
loop power<br />
Auto Power Off Yes No N/A<br />
Low Battery Indicator Yes N/A<br />
Hold Function Yes N/A<br />
Tmax. recording No Yes N/A<br />
Differential Temp. No Yes N/A<br />
Stop Watch No Yes N/A<br />
T<br />
E<br />
M<br />
P<br />
E<br />
R<br />
A<br />
T<br />
U<br />
R<br />
E<br />
91
O<br />
E<br />
M<br />
P<br />
R<br />
O<br />
D<br />
U<br />
C<br />
T<br />
S<br />
92<br />
OEM<br />
Original Equipment Manufacturers (OEM’s) require individual solutions to suit the needs of their customers.<br />
ROTRONIC have been producing customised humidity measurement products to suit the OEM for<br />
many years, and have a wide breadth of experience in satisfying this specialist need.<br />
Today, our OEM capability is greater than ever, from the simplest sensor<br />
supply, right through to complex transmitters for the industrial<br />
process market. One thing is clear, the demands of the customer and<br />
the end use are rarely the same, so the need for a professional and<br />
fl exible supplier is key.<br />
As each project is different, our experienced sales team will discuss<br />
project objectives, technical requirements and target costs at a preliminary<br />
meeting. We will then formulate an initial proposal based on<br />
this discussion and submit this to the customer.<br />
After agreeing a fi nal specifi cation, samples can then be submitted for<br />
technical approval and testing. During this phase, ROTRONIC are able<br />
to participate in the customer assessment of product suitability, and if<br />
required, provide secondary testing of the completed assembly in our<br />
own accredited test facilities. We are also able to advise on the fi nal<br />
assembly and calibration process.<br />
Wherever possible, we will utilise existing products or sub assemblies<br />
in the creation of an OEM solution. This can provide signifi cant advantages<br />
in design and development costs, as well as reducing the start<br />
up times.<br />
ROTRONIC OEM Product Capability<br />
• %rh sensors<br />
• Calibrated sensor modules<br />
• Transmitter or probe sub assemblies<br />
• Standard ROTRONIC products with customers own branding<br />
ROTRONIC OEM Support Capability<br />
• Custom design<br />
• Custom packaging<br />
• Labelling and barcodes<br />
• Documentation, including manuals<br />
• CAD drawings for manufacturing records<br />
• Calibration materials and systems<br />
• Training of customers technical and sales staff
%rh Sensors<br />
OEM<br />
In many high volume applications, the supply of only the %rh sensor<br />
is a cost effective option. In these circumstances the OEM should carefully<br />
consider the process of calibrating the fi nal measurement circuit<br />
to obtain the required performance. When calculating the actual cost<br />
of the implementation of humidity measurement, the sensor cost<br />
must include provision of the calibration process, circuit design and<br />
fi nal assembly. In many cases, the specifi cation of a pre-calibrated<br />
measurement module can be equally cost effective, and can reduce<br />
the ongoing costs of production.<br />
ROTRONIC can supply a range of %rh sensors based on capacitive or<br />
resistive technologies. Various standard products are available with<br />
pre-defi ned specifi cations, dimensions and characteristics. We are<br />
also able to offer customised sensor production to suit specifi c project<br />
requirements.<br />
Calibrated %rh Sensor modules<br />
The advantage of implementing a pre-calibrated sensor module is that<br />
the OEM does not have to develop a measurement circuit or an inhouse<br />
calibration system.<br />
The appropriate product can be specifi ed to be compatible with existing<br />
interface and power supply requirements, and with simple connection<br />
to the fi nal application prior to delivery. The whole specifi cation,<br />
design and supply of the humidity measurement element of the OEM<br />
need can be handled by ROTRONIC, leaving the customer to focus on<br />
their core product development and support.<br />
ROTRONIC in house calibration procedures have been developed over<br />
many years, and proven in many thousands of instances. The end result<br />
for the OEM customer is a well developed production process that<br />
assures best possible measurement performance with zero investment.<br />
%rh Transmitter or Probe Sub Assemblies<br />
For OEM customers who offer their own branded range of %rh sensors,<br />
for end uses such as HVAC/BMS, process control or data-acquisition,<br />
ROTRONIC can supply a completed and calibrated product to fi t<br />
the customers own housings.<br />
In these circumstances, the customer has two main advantages. The<br />
responsibility for product design, assembly and calibration is handled<br />
by ROTRONIC, which minimises production costs and component<br />
stock risk. The customer also benefi ts from an ‘own brand’ product<br />
which has the very best performance capability, and has access to<br />
ongoing development to keep the product at the leading edge of the<br />
humidity market.<br />
Standard products with customers own branding<br />
Throughout the pages of this catalogue you will fi nd a range of humidity<br />
measurement products that are market leading in terms of performance,<br />
features and price. ROTRONIC are happy to effect a simple<br />
‘re-brand’ of the standard product range so that the OEM can offer a<br />
class leading product with no development cost and minimal stock<br />
risk.<br />
Ancillary products such as calibration materials, replacement fi lter<br />
elements and software are of course already available. Support documentation<br />
such as manuals, software validation, type approvals and<br />
drawings can be easily re-branded on behalf of the OEM customer.<br />
O<br />
E<br />
M<br />
P<br />
R<br />
O<br />
D<br />
U<br />
C<br />
T<br />
S<br />
93
O<br />
E<br />
M<br />
P<br />
R<br />
O<br />
D<br />
U<br />
C<br />
T<br />
S<br />
94<br />
Example OEM Products<br />
The products described are standard OEM products which are mass produced for many existing cus tomers.<br />
They are available on very short delivery times, often from stock, and require no further development<br />
or documentation. Full technical datasheets are available in standard formats and show full technical<br />
and mechanical specifi cations. The range of products shown is by no means defi nitive, we could fi ll the<br />
whole of this catalogue with the OEM products in current production at ROTRONIC, so please contact us<br />
if the product you need is not shown.<br />
Technical Data:<br />
CS %rh sensor<br />
The CS %rh sensor is a substrate based capacitive %rh sensor. It is<br />
designed specifi cally for applications where high quality is as important<br />
as cost. Three standard versions are available to suit most applications.<br />
Features overview:<br />
• Wide range of operating temperatures<br />
• Chemically resistant<br />
• Long term stable<br />
• Fast response times<br />
• Low hysteresis<br />
• Heated version for high humidity applications (CS70)<br />
• Compact dimension and high sensitivity(CS10)<br />
• Fast response & solvent resistant (CS30)<br />
CS10 CS30 CS70<br />
Humidity measuring range 0...100 %rh 0...100 %rh 0...100 %rh<br />
Temperature operating range -30...150°C -40...190°C -10...50°C<br />
Typical capacitance at 30 %rh and 23°C 140 pF ±40 pF 300 pF ±40 pF 250 pF ±50 pF<br />
Typical sensitivity (15 ... 95 %rh) 0.4 pF / %rh 0.45 pF / %rh 0.45 pF / %rh<br />
Linearity at 23°C ± 1.5 %rh ±2.0 %rh ±2.0%rh<br />
(20...90%rh) (20...95 %rh (20…95 %rh)<br />
Hysteresis < 1.5 %rh < 2.0 %rh < 2.0 %rh<br />
Response Time t90
HygroClip<br />
Example OEM Products<br />
The HygroClip-S is a standard humidity and temperature sensor module<br />
which is widely used throughout the ROTRONIC product range<br />
on end-user products such as handheld instruments, data loggers and<br />
transmitters. It is already in widespread use by third party OEM instrument<br />
manufacturers thanks to its excellent performance and price.<br />
HygroClip is available as standard in a wide range of confi gurations<br />
to suit almost any end use, and in addition, can be customised to<br />
suit speci fi c OEM needs. Variations in mechanical packaging, colour,<br />
connectors and cable lengths can all be incorporated into a unique<br />
design.<br />
Further information and full technical specifi cations can be found<br />
on page 62 to 67.<br />
Transmitter sub assembly<br />
H290 is an OEM humidity and temperature product with an impressive<br />
specifi cation. It is particularly well suited to applications such as climatic<br />
chambers and drying systems. It is available either as a pcb and<br />
probe combination for fi tting into the customers own enclosures or<br />
housings, and can also be supplied in an industry standard IP65 case.<br />
H290 provides a liners analogue output of 4…20 mA or 0…10 V from<br />
a power supply of 10…35 VDC or 12…24 VAC. Temperature measurement<br />
is by direct connection to a Pt100 or Thermistor, depending on<br />
the customers requirements.<br />
Also featured on the H290 is a compensation system for operation<br />
over a wide –50…200°C range, with integrated cable length compensation.<br />
This means that whatever the measurement temperature, or<br />
the differential in temperature between sensors and electronics, optimum<br />
results will be obtained.<br />
THT Series<br />
A range of humidity transmitters with excellent stability and very cost<br />
effective pricing. The THT series offers a range of analogue outputs<br />
such as 4…20mA and 0…10 Volt, for both humidity and temperature.<br />
There is also as the option to connect directly to a temperature sensor<br />
such Pt100 or Thermistor.<br />
THT is highly suitable for close control applications such as air conditioning<br />
or building monitoring where steady state conditions are<br />
usual.<br />
Roline L<br />
Our standard low cost transmitter is particularly well suited to OEM<br />
application thanks to its excellent combination of performance and<br />
price. It has a wide choice of measurement ranges and output signals,<br />
and its compact printed circuit board dimensions means that it can be<br />
easily integrated or reconfi gured into existing housings.<br />
See pages 53 to 55 for further details.<br />
For full technical specifi cations, dimensions, and specifi c product features, please request<br />
the individual datasheets.<br />
O<br />
E<br />
M<br />
P<br />
R<br />
O<br />
D<br />
U<br />
C<br />
T<br />
S<br />
95
C<br />
A<br />
L<br />
I<br />
B<br />
R<br />
A<br />
T<br />
I<br />
O<br />
N<br />
96<br />
Calibration<br />
ROTRONIC instruments have excellent long-term stability characteristics, with better than ±1%rh stability<br />
over a year in normal conditions, but we still recommend that regular calibration checks are performed<br />
(once per year typically). Normal conditions can be defi ned when high temperature or humidity, or MAC<br />
(Maximum Allowable Concentration) levels of chemical pollutants are not typical. Many company operating<br />
procedures call for calibrations more frequently, depending on internal quality assurance systems.<br />
Why is calibration essential?<br />
Today, many companies are working under to ISOO9000 standards and are therefore obliged to calibrate their<br />
measuring equipment on a regular basis. Organisations such as the FDA (The Food and Drug Administration<br />
in the USA) also demand that the devices are calibrated and traceable to national standards. Last but not<br />
least, the quality standards defi ned by each company ask for best possible accuracy and proof of traceability.<br />
Hence, it is in the interest of the user, to have equipment calibrated and adjusted in order to maintain optimum<br />
performance.<br />
We offer calibration devices and accessories for all probes manufactured by ourselves, and also for products<br />
produced by other manufacturers. Please contact us for guidance on the most appropriate calibration device<br />
and standards.<br />
Key features<br />
• Non-saturated salt solutions<br />
• Sealed glass ampoules<br />
• Ready-to-use solutions<br />
• SCS-certifi ed<br />
• Specifi c calibration devices<br />
Your benefi ts<br />
Section contains Page<br />
Humidity Standards 97<br />
� Certifi ed and traceable<br />
� Long shelf life<br />
� Precise and easy to handle<br />
� Ready for use – no solution-preparation<br />
Calibration devices 98<br />
� Easy to use<br />
� Robust<br />
� Optimised chamber volume<br />
Calibration with PC 99<br />
� HygroLab calibration<br />
� HygroFlex calibration<br />
� Simple handling, low temperature dependence<br />
� Long shelf life – 10 years guaranteed<br />
� No mistakes during preparation<br />
� Traceable to national standards<br />
� Optimum volume for each probe<br />
Rotronic and some Rotronic distributors or subsidiaries offer calibration<br />
seminars for their customers.<br />
Ask your distributor or Rotronic subsidiary for further information.
SCS* humidity standards<br />
The humidity standards from ROTRONIC are delivered in boxes of<br />
5 sealed ampoules of the same humidity value. Each ampoule is<br />
marked with the %rh value and a serial number.<br />
SCS* certifi ed humidity standards<br />
Order code: Humdity value<br />
EA00-SCS 0.5%rh<br />
EA05-SCS 5.0%rh<br />
EA10-SCS 10.0%rh<br />
EA11-SCS 11.3%rh<br />
EA20 SCS 20.0%rh<br />
EA35-SCS 35.0%rh<br />
EA50-SCS 50.0%rh<br />
EA65-SCS 65.0%rh<br />
EA75-SCS 75.3%rh<br />
EA80-SCS 80.0%rh<br />
EA95-SCS 95.0%rh<br />
Uncertainty of Rotronic<br />
SCS* Humidity Standards<br />
Humidity in %rh Measurement uncertainty at 23 ±2°C<br />
5 ± 0.1 %rh<br />
10 ± 0.3 %rh<br />
11.3 ± 0.3 %rh<br />
20 ± 0.3 %rh<br />
35 ± 0.5 %rh<br />
50 ± 0.9 %rh<br />
65 ± 0.9 %rh<br />
75.3 ± 0.9 %rh<br />
80 ± 1.2 %rh<br />
95 ± 1.2 %rh<br />
* SCS: Swiss Calibration Services<br />
Humidity standards<br />
The most frequently used values are 35 and 80%rh, which are used to<br />
perform a 2-point calibration. All ampoules contain a non-saturated<br />
salt solution, apart from the 0% standard, which uses a highly porous<br />
ceramic material (molecular sieve). An SCS certifi cate stating the<br />
traceability and uncertainty of the humidity standard is enclosed with<br />
every pack.<br />
<strong>Instruments</strong> produced by other manufacturers may require different<br />
values for adjustment. ROTRONIC offer a complete range of %rh values<br />
to suit most requirements.<br />
C<br />
A<br />
L<br />
I<br />
B<br />
R<br />
A<br />
T<br />
I<br />
O<br />
N<br />
97
C<br />
A<br />
L<br />
I<br />
B<br />
R<br />
A<br />
T<br />
I<br />
O<br />
N<br />
98<br />
EM-15/25<br />
EMV-15/25<br />
EGL/ER-15<br />
ERV-15 EGS<br />
EDM-15/25<br />
Calibration devices<br />
Calibration Devices<br />
Calibration devices<br />
Order code: Suitable for Mounting / Orientation<br />
ER-05 probes with 4/5 mm ø push-on<br />
EGL probes with 10 mm ø (A1) push-on<br />
ER-15 probes with 15 mm ø push-on<br />
ER-18K probes with 18 mm ø push-on<br />
ER-20K probes with 20 mm ø push-on<br />
ERV-15 probes with 15 mm ø push-on / vertical<br />
EM-15 probes with 15 mm ø push-on<br />
EM-25 probes with 25 mm ø push-on<br />
EMV-25 probes with 25 mm ø push-on / vertical<br />
EMV-15 probes with 15 mm ø push-on / vertical<br />
EDM 15/25 2 probes, 15 & 25 mm ø screw-in<br />
EM-G screw-in probe type E, HP...E... screw-in<br />
EGS for all ROTRONIC sword probes push-on<br />
EAS for bell probe AS-ST<br />
EAWC for AWC-measuring station<br />
EBFC for web probe BFC<br />
ERA for bell probe for rolls<br />
WP-14 for probe AWD, AWVC, AW-DIO<br />
The ROTRONIC calibration devices are small, airtight chambers, that<br />
fi t exactly to the respective probes. The lower part is a screw-mount<br />
lid, into which the humidity standard is fi lled, together with a textile<br />
pad. After a period of stabilisation, typically 60 minutes at stable temperature,<br />
the required humidity value is attained. The instrument can<br />
now be calibrated against the humidity reference value.<br />
Calibration devices are available for the entire range of Rotronic<br />
products, and we can also supply calibration devices for third party<br />
probes.<br />
The inner volume of the calibration device should not be too large; it<br />
should not exceed 50 ml of free space when the probe is fi tted. When<br />
the volume is too large, the correct humidity may eventually not be<br />
generated and the calibration reference incorrect.
Calibration of HygroClip probes<br />
with HygroLab 2 & 3<br />
Calibration<br />
The digital HygroClip probes may easily be calibrated in quantities<br />
by using the bench-top instrument HygroLab2. Up to 4 probes can be<br />
connected simultaneously to a single HygroLab 2. When the software<br />
HW3 is used, as many as 32 HygroLabs can be networked together,<br />
thus offering the possibility of calibrating or adjusting 128 probes. For<br />
customers who must calibrate many probes, this is a solution that<br />
saves a lot of time.<br />
As the instruments, probes and humidity standards can be maintained<br />
in a single room, not only the acclimatisation time can be reduced but<br />
also the accuracy will be improved.<br />
The HygroLab may be connected to any digital HygroClip probe for<br />
calibration.<br />
Calibration with a PC and HW3 software<br />
Up to 64 probes connected to a HygroFlex network of max. 32 transmitters<br />
may be calibrated by a PC, with the HW3 software.<br />
The calibration devices can be mounted on all probes on the respective<br />
transmitters, and fi nally, the calibration or adjustment<br />
be made with a few mouse clicks.<br />
The system will also print calibration reports if required.<br />
Calibration by direct PC connection<br />
Using the MOK connection cable and HW3 software<br />
Order code:<br />
MOK-02-WIN Adapter cable<br />
HW3 Universal software<br />
C<br />
A<br />
L<br />
I<br />
B<br />
R<br />
A<br />
T<br />
I<br />
O<br />
N<br />
99
H<br />
W<br />
3<br />
S<br />
O<br />
F<br />
T<br />
W<br />
A<br />
R<br />
E<br />
100<br />
HW3 Core Features<br />
HW3 Software<br />
Thanks to advances in digital technology, most of the instruments<br />
now produced by ROTRONIC feature a bi-directional RS232 interface.<br />
This works with PCs to display measured data, download recorded<br />
measurements or confi gure the system. In the past, the user often<br />
had a to use separate software for each instrument, which meant<br />
they had to learn different programs to be able to operate, and make<br />
the best use of their instrument. Today, ROTRONIC provides a single<br />
software package, HW3, which is compatible with our entire range of<br />
products, so that the user has only one system to learn for every humidity<br />
measurement application.<br />
HW3 software is developed and maintained in house at ROTRONIC<br />
by a skilled team of software developers. They are also involved in<br />
the development of our instrumentation, so are familiar with entire<br />
systems operation fi rst hand. This ensures that we are able to offer<br />
immediate support for products in the fi eld, and make sure that when<br />
new features and software routines are introduced, they are always<br />
compatible with the instrumentation hardware that we supply, or have<br />
supplied in the past.<br />
As well as our in-house developers, ROTRONIC has a second excellent<br />
source of software developers – our customers. Over many years of<br />
supplying PC compatible instrumentation, we have received many<br />
customer requests for new features or improvements. The feedback<br />
we receive is always considered when we are developing improvements<br />
to our software, so that over many years, it has evolved into<br />
one of the most comprehensively featured and user friendly packages<br />
on the market today.<br />
The range of features within HW3 is extensive, and the confi guration of the instrument connected of course<br />
infl uences what is possible, so check the specifi cation of your instrument of choice to determine compatibility<br />
with the following features:<br />
• Display of measured values directly on your PC<br />
• Alarm setting and monitoring<br />
• Audible, visual, email or SMS alarm notifi cation<br />
• Display of recorded values from data loggers<br />
• Display of an entire network of connected instruments<br />
• Data acquisition of measured values from a network of connected instruments<br />
• Archiving of measurement data<br />
• Instrument confi guration<br />
• Instrument identifi cation<br />
• Instrument status<br />
• Probe recalibration<br />
• Production of calibration certifi cates<br />
• Calculation of different psychrometric parameters such as dewpoint, wet-bulb temperature,<br />
mixing ratio, etc.<br />
• Accelerated Water Activity analysis (HygroData Quick upgrade)<br />
• …and many more…<br />
HW3 Validation<br />
Many ROTRONIC customers have learnt to depend on the accuracy and reliability of our humidity and temperature<br />
measurement systems. The advent of PC compatible products for measurement display and storage,<br />
as well as instrument confi guration and maintenance, has opened new many application possibilities.<br />
In many high value and critical applications accurate measurement is only part of the story. Data integrity<br />
and security is today an essential requirement, and in many circumstances, software must be validated for<br />
the measurement data to be accepted. HW3 is regularly submitted for software validation, and certifi cates<br />
of compliance are available to our customers. Of particular importance is the FDA regulation 21 CFR Part 11,<br />
which HW3 meets (documentation available on request).
Connect handheld instruments<br />
for confi guration,<br />
calibration, display and<br />
record measured values.<br />
Monitoring and display of water<br />
activity measurements including<br />
accelerated analysis and automatic<br />
data capture.<br />
HW3 Feature Overview<br />
Connect transmitters for<br />
confi guration, calibration,<br />
measurement display and<br />
data acquisition.<br />
Display measured values from a<br />
network of 32 HygroFlex or HygroLab<br />
instruments. Up to 128 probes simultaneously.<br />
Validated software<br />
FDA 21 CFR Part 11 compliant.<br />
Program data loggers<br />
and download data.<br />
Setting and notifi cation of<br />
alarms, audible, visual, SMS<br />
or e-mail.<br />
Control the calibration and<br />
adjustment of digital probes,<br />
including production of<br />
calibration certifi cates.<br />
H<br />
W<br />
3<br />
S<br />
O<br />
F<br />
T<br />
W<br />
A<br />
R<br />
E<br />
101
H<br />
W<br />
3<br />
S<br />
O<br />
F<br />
T<br />
W<br />
A<br />
R<br />
E<br />
102<br />
HW3 Features<br />
Features in More Detail<br />
Instrument Display Form<br />
With HW3 running on a PC and a compatible instrument connected, the<br />
measured values with trend indicators are displayed live on the monitor,<br />
together with instrument identifi cation. From this view it is possible to<br />
activate data acquisition of the measured values directly to the PC’s hard<br />
drive.<br />
For handheld instruments this feature is useful for logging local conditions<br />
to the PC, or if a cable mounted probe is fi tted, conditions inside a climatic<br />
test chamber or incubator.<br />
Transmitters are displayed in the same way, and when a multi point transmitter<br />
network is used, 32 instruments, each with up to 2 probes can be<br />
monitored simultaneously.<br />
If alarms are programmed, visual indication on this display form can be<br />
supplemented with audible signals and user notifi cation via email or SMS<br />
messages.<br />
HW3 Vision Graphic Display Module<br />
HW3 Vision display module presents either logged data fi les or live<br />
measurements in a convenient graphical format (scrolling). From this<br />
screen graphs can be either directly printed, or copied and pasted into<br />
documents or reports. Usual data analysis tools such as zoom, ruler and<br />
gridlines are included.<br />
Various formatting options are available through on screen icons, these<br />
include changing the graph background, trace colour, legends, gridlines<br />
and axis. The base text used within the HW3 Vision graph display module<br />
can also be confi gured by the user to suit specifi c application or operational<br />
needs.<br />
Instrument Confi guration Form<br />
If the ROTRONIC instrument you purchase has an RS232 interface, the<br />
Instrument Confi guration Form provides you with the tools to fully confi -<br />
gure or reconfi gure directly from the PC.<br />
Using a system of confi guration upload and download means that settings<br />
can be stored on the PC for future use or reference. This also means that<br />
programming several instruments with the same confi guration can be less<br />
time consuming.<br />
<strong>Instruments</strong> settings that can be modifi ed through this option include;<br />
probe type, display settings, units of measurement (International variations<br />
all included), measuring ranges, psychrometric calculations, analogue<br />
output scaling and serial communications setting (data format, network<br />
address etc).<br />
Each instrument can also be digitally renamed by the user to enable identifi<br />
cation of use or location, and notes describing the instruments history<br />
can also be stored with the confi guration data on the PC’s hard drive.<br />
HygroData Quick<br />
All current versions of HW3 are shipped with advanced water activity analysis<br />
software integrated. To access this function requires an additional<br />
license; see ordering information. For a full description of this feature,<br />
please refer to the Water Activity section of this catalogue.<br />
SoftCal Probe Calibration<br />
One of the most important features of HW3 is the SoftCal utility that controls<br />
the calibration process of our digital probes, which of course do not feature<br />
traditional analogue potentiometers. Within SoftCal you can perform<br />
zero, slope and linearity adjustment for humidity, and zero and slope for<br />
temperature. It is also possible to make a single point adjustment against<br />
a defi ned reference.In all cases the user can choose defi ned ROTRONIC<br />
calibration values, or make their own selection. As a precaution against incorrect<br />
adjustments, SoftCal automatically rejects adjustments greater than<br />
5%rh, as this is likely to be an indication or incorrect calibration method, or<br />
a faulty instrument.
Psychrometric Calculations<br />
All ROTRONIC instruments measure percentage relative humidity<br />
(%rh) and temperature (°C/F). From the two values it is possible to calculate<br />
other psychrometric values such as dew-point, frost-point, wetbulb<br />
temperature, mixing ratio, absolute humidity, enthalpy, partial<br />
water vapour pressure, saturation vapour pressure and more.<br />
The calculation software in HW3 uses WMO* verifi ed formulae to<br />
make these calculations, and also provides the user with the option to<br />
input their own parameters (e.g. input mixing ratio & temperature to<br />
calculate %rh). Other advanced options such as dew/frost-differentiation,<br />
and pressure or altitude compensation are included.<br />
*World Meteorological Organisation<br />
Alarms<br />
Specifi cations and Hardware Requirements<br />
Processor Recommended Pentium 233 Mhz or better<br />
Operating System Microsoft Windows 95, 98, ME, NT, 2000<br />
Audio Sound card or integral speaker for playback of alarm .WAV fi les<br />
Network LAN or modem for email or SMS alarm feature<br />
Memory 64 Mb or better<br />
Disk space 20 Mb<br />
Monitor VGA/SVGA<br />
Resolution 800 600 or better, High Colour 16Bit or better (256 colour minimum)<br />
Connection RS232 (Com 1…4)<br />
Supply format CD (mini type suits all CD drives)<br />
Upgrades Available on-line to registered users<br />
Manual On CD HTML format<br />
HW3 Ordering Information<br />
HW3 Features and Ordering Information<br />
Our HygroPalm, HygroLab, HygroFlex and M Series instruments with<br />
RS232 interface can all provide a continuous stream of measurement<br />
data for display and data acquisition within HW3. It is also possible to<br />
defi ne 4 alarm limits (High and Low, humidity and temperature).<br />
When alarm conditions are reached, HW3 can inform the user with<br />
either audible (.WAV fi les) or visual indication. In addition, the software<br />
can be confi gured to send an email or SMS text message (requires<br />
LAN or Modem connection).<br />
HW3 is typically supplied as a HYGRODATA bundle with the serial RS232 cable to suit the different instruments,<br />
please consult the relevant section of this catalogue. The main options are detailed below:<br />
Order code Description RS232 Cable order code<br />
HW3 Software only supplied on CD ROM N/A<br />
HygroData HP HW3 software and connecting cable to suit HygroPalm 2 and 3 AC1622<br />
HygroData HL HW3 software and connecting cable to suit HygroLog AC1590<br />
HygroData Lab HW3 software and connecting cable to suit HygroLab 11.01.6218<br />
HygroData HTS HW3 software and connecting cable to suit HygroFlex 2 and 3 AC1627<br />
HygroData Quick Upgrade License to add AW Quick modes to HW3 N/A<br />
H<br />
W<br />
3<br />
S<br />
O<br />
F<br />
T<br />
W<br />
A<br />
R<br />
E<br />
103
T<br />
H<br />
E<br />
O<br />
R<br />
Y<br />
104<br />
Theory<br />
Humidity measurement in air<br />
Humidity in the form of water vapour is always present in the air. It is measured either as absolute or relative<br />
humidity. These two terms are defi ned as follows:<br />
Absolute humidity of a gas mixture<br />
The absolute humidity of a gas mixture is defi ned as the quantity of water vapour (kg) contained in each<br />
volume of the gas mixture. It is expressed in terms of kg water vapour per kg gas mixture.<br />
The water vapour present in the gas mixture generates a pressure, which is part of the total barometric<br />
gas pressure. The vapour pressure and the absolute humidity cannot exceed the saturation level at a given<br />
temperature. Above this level, water is separated out in liquid form. The maximum pressure is described as<br />
saturation pressure and is highly temperature-dependent.<br />
The absolute humidity of the air is of limited practical signifi cance, because one essential factor, the temperature,<br />
is not taken into account in the determination of absolute humidity.<br />
Relative humidity of a gas mixture<br />
Relative humidity is defi ned as the ratio of the actual water vapour pressure to the highest possible water<br />
vapour pressure:<br />
%rh = 100 x p/ps<br />
p = Water vapour pressure in the<br />
gas mixture at ambient temperature<br />
ps = Saturated water vapour pressure<br />
at ambient temperature<br />
Therefore, 100%rh corresponds to the maximum amount of water vapour, which a gas mixture can contain.<br />
Below the saturation level, the water vapour pressure p and hence also the relative humidity (%rh) are proportional<br />
to the total barometric pressure. Since the highest possible water vapour pressure ps is extremely<br />
temperature-dependent, the relative humidity is also temperature-dependent. The relative humidity therefore<br />
decreases, when the temperature rises, and vice versa.<br />
Infl uence of temperature fl uctuations of ±1°C at various temperatures and humidities:<br />
%rh 10 °C 20 °C 30 °C 50 °C 70 °C<br />
10 %rh ±0.7% ±0.6% ±0.6% ±0.5% ±0.5%<br />
50 %rh ±3.5% ±3.2% ±3.0% ±2.6% ±2.3%<br />
90 %rh ±6.3% ±5.7% ±5.4% ±4.6% ±4.1%<br />
It is extremely important that the probe and the sample to be measured have the same temperature to<br />
achieve useful measurements.<br />
To gain a better understanding of the relationships, we refer to the h-x diagram of humidity in air<br />
(Mollier’s diagram). This illustrates clearly the relationship between temperature, moisture content and relative<br />
humidity.<br />
Relative humidity below 0°C<br />
At temperatures below 0°C, the saturation pressure above water in liquid form (supercooled): e w differs<br />
from the saturation pressure above ice: e i .<br />
e w = Water vapour saturation pressure<br />
e i<br />
above water at ambient temperature<br />
= Water vapour saturation pressure<br />
above ice at ambient temperature<br />
T e w e i %rh<br />
°C hPa hPa –<br />
0 6.11 6.11 100<br />
–5 4.22 4.02 95<br />
–10 2.87 2.60 91<br />
–15 1.91 1.65 87<br />
–20 1.26 1.03 82<br />
–25 0.81 0.63 78<br />
–30 0.51 0.38 75<br />
For this reason, a measurement of 75%rh at -30°C corresponds to saturation (100%rh) above ice.
Humidity measurement in solids<br />
Theory<br />
Similar to gases, solids such as paper or food can also absorb and retain water or desorb it. Materials with<br />
this property are called hygroscopic. Depending on the point of view, there are two different observations<br />
that characterise the humidity state of a material.<br />
Water content<br />
The water content of a material is the amount of water contained in the material, expressed in percentage<br />
of weight. This aspect is interesting for situations, where a material is sold by weight. However, if we talk of<br />
the physical properties of a material, then the water content is of no interest, as it provides no meaningful<br />
information.<br />
Equilibrium humidity<br />
A hygroscopic material tries to establish equilibrium of its humidity with that of its environment. The presence<br />
of water in the material produces a water vapour pressure (pm) on the material surface. If this pressure<br />
(pm) is equal to the water vapour pressure (p) of the ambient atmosphere, then the material achieved<br />
equilibrium humidity with its environment. Any difference between the pm and the p produces a water exchange<br />
and therefore a change of the water content of the material concerned, until equilibrium is achieved.<br />
Equilibrium humidity of a material is therefore defi ned as the relative humidity of the ambient atmosphere<br />
that has to prevail in order to cause no exchange of water.<br />
Water activity<br />
The relative humidity, which must prevail in the surrounding atmosphere to avoid water exchange between<br />
material and air, is defi ned as water activity. It is practically the same as the equilibrium humidity of a material<br />
in the defi nition, but is not stated in 0….100%, but in 0…1Aw. The water activity is a measure of the<br />
degree of freedom of the water retained in various ways in a material.<br />
The water activity directly determines the physical, mechanical, chemical and microbiological properties of<br />
the material as well as interactions, such as pourability, lump formation, cohesion, static electricity, etc. In<br />
the food industry, water is a highly signifi cant factor in the shelf life of semi-fi nished and fi nished products.<br />
Sorption isotherms<br />
At equilibrium, the relation between water content and equilibrium humidity of a material can be displayed<br />
graphically by a curve, the so-called sorption isotherm.<br />
For each humidity value, a sorption isotherm indicates the corresponding water content value of the material<br />
at a given, constant temperature. If the composition or quality of the material changes, then its sorption<br />
behaviour also changes. Because of the complexity of sorption processes, the isotherms cannot be determined<br />
by calculation, but must be recorded experimentally for each product. Therefore in practice, water<br />
content and water activity should be viewed as two independent parameters.<br />
T<br />
H<br />
E<br />
O<br />
R<br />
Y<br />
105
T<br />
H<br />
E<br />
O<br />
R<br />
Y<br />
106<br />
h-x diagram
1 Explanations of characters<br />
Explanations to the h-x diagram<br />
1.1 ß: Dry air quantity in kg per m 3 process air<br />
1.2 t: Temperature of the process air in °C<br />
1.3 x: Water vapour content in g per kg dry air of the process air<br />
1.4 h: Heat content (enthalpy) in kJ per kg dry air of the process air<br />
1.5 ϕ: Relative humidity of the proces air<br />
1.6 Δh : Heat consumption in kJ per kg water<br />
Δx<br />
NB: We designate prcess air as air in different states, as found during drying (fresh air/warmed<br />
air from the furnace and/or a heater/conditioned air, also exhaust air).<br />
2. Use of the h-x diagram<br />
2.1 Dry air porition ß in kg per m 3 process air<br />
Example:<br />
Measured values of the exhaust air in a drying plant tA=46°C; ϕ = 80%rh;<br />
exhaust air quantity 12000m 3 /h<br />
The line drawn parallel to the dotted lines of the diagram through the status point of the exhust<br />
air (Intersection of the t-line 46°C and the humidity curve 80%) results in its extension at<br />
the Intersection with the left margin scale at ß=1,018kg dry air per m 3 of this exhaust air. At<br />
12000m 3 /h, the dry air quantity is thus 12000 • 1,018=12200kg/h.<br />
2.2 Water vapour content in g per kg dry air of the process air<br />
2.2.1 The vertical line drawn through the status point (in our example 46°C; 80 %rh) results at the<br />
intersection with the horizontal abscissa a water vapour content of x 2 =54g per kg dry air of this<br />
exhaust air.<br />
2.2.2 If the hot air fed into the drying chamber is created by heating outside air (in the example temperature<br />
20°C; 70%rh) this hot air brings x 1 = hot water per kg dry air with it (determined<br />
of x 1 = 10g hot water per kg dry air with it (determination of x 1 as described in 2.2.1]).<br />
this means that each kg of dry air has absorbed Δx = x 2 - x 1 =44g Wasser aufgenommen hat.<br />
2.2.3 With 12200kg dry air/h, 12200 • 0,044=536,8kg water are withdrawn from the product being<br />
dried per hour.<br />
2.3 Heat content inkJ per kg dry air of the processed air.<br />
2.3.1 The line drawn parallel to the lines of equal heat content (h lines) through the status point (in<br />
our example 46°C; 80%rh) results on the one hand at the intersection with the inclined abscissa<br />
in a heat content h 2 =185kJ/kg dry air of this exhaust air.<br />
(Conversion to kcal: 1kcal=4,1868kJ).<br />
On the other hand this extended parallel line in the upper part of the diagram helps to determine<br />
the approximate hot air temperature (see 2.5) for this heat content.<br />
2.3.2 The heat content of the outside air (in our example 20°C; 70%) is h 1 =45kJ,<br />
(determined as described in 2.3.1) so that heating by Δh=h 2 -h 1 =140kJ per kg dry air is necessary<br />
for drying.<br />
However, the actual heating must be higher than this Δh, due to various heat losses such as<br />
radiation, heating of the goods to be dried, the drying cars and frame etc. But for well insulated<br />
plants, no more than 15 kJ/kg dry air.<br />
2.3.3 The theoretical heat consumption in our example is thus:<br />
12200 • 140=1,708 million kJ/h.<br />
2.4 Theoretically required heat quantity per kg of expelled water:<br />
The parallel line drawn through the zero point to the connecting line of the status points for outside<br />
air and exhaust air indicates the theoretical heat consumption at the intersection with the right margin<br />
scale:<br />
Δh<br />
=318<br />
kJ<br />
theor. heat consumption<br />
Δx kg<br />
per kg H2O calculation:<br />
Δh (from 2.3.2) = 140 = 3182 kJ<br />
Δx (from 2.2.2) 0,044 kg<br />
2.5 Hot air temperature<br />
The vertical line drawn through the status point of the outside air (see 2.2.2) intersects with the h line<br />
of the exhaust air (see 2.2.1) at a particular point. If one draws a line through this point parallel to the<br />
lines of equal temperature (t lines), one obtains the theoretically required hot air temperature at the<br />
intersection with the ordinate, in our example 157°C.<br />
T<br />
H<br />
E<br />
O<br />
R<br />
Y<br />
107
T<br />
H<br />
E<br />
O<br />
R<br />
Y<br />
108<br />
Humidity defi nitions<br />
Theory<br />
Relative humidity (%rh)<br />
Is defi ned as the ratio of the quantity of water vapour present in the air to the maximum possible water vapour<br />
at the same temperature.<br />
Dew point (Dp)<br />
The dew point is that temperature, where gas being cooled, begins to condense water vapour into liquid<br />
water. The dew point may also occur below 0°C (super-cooled water). This point has to be distinguished<br />
from freezing point (see below).<br />
Frost point (Fp)<br />
The frost point is that temperature, where gas being cooled begins to condense water vapour in the form of<br />
ice. Freezing point occurs only at temperatures below freezing.<br />
Water vapour density (Dv) in g/m 3<br />
This is the ratio between the mass of the water vapour to the volume of the gas mixture, in which the water<br />
vapour is.<br />
Water vapour content (Q) in g/kg<br />
This is also called specifi c humidity and is the ratio between the mass of the water vapour to the mass of<br />
the gas mixture, in which the water vapour is.<br />
Mixing ratio ( R) in g/kg<br />
This is the ratio of the mass of the water vapour to the mass of the dry gas mixture, in which the water vapour<br />
is.<br />
Water vapour partial pressure (E) in hPa<br />
This is the pressure of the gaseous phase of the water in a gas mixture.<br />
Water vapour saturation pressure (Ew) in hPa<br />
This is the maximum pressure that the water vapour can reach at saturation for the appropriate temperature.<br />
Enthalpy (H)<br />
Enthalpy is the measurement for the determination of the energy required, to change the gas mixture from<br />
a certain temperature/humidity state to another. Enthalpy is not used as an absolute value, but as the difference<br />
between two points of particular interest. The choice of 0 °C and 0 %rh for zero enthalpy was arbitrary.<br />
Mixing ratio/Volume (PPMv)<br />
This is the relationship between the number of water vapour molecules to the number of molecules of the<br />
other components in the gas. Once this value is determined, it does not change with pressure or temperature.<br />
Common faults/remedies<br />
Not only humidity, but also many other physical parameters are measured in industrial processes. The<br />
most important are temperature, pressure, air speed, etc. The measurement of humidity is different to other<br />
parameters in one important aspect, namely that humidity cannot be considered as an absolute value, because<br />
the measuring principle is based on the exchange of water vapour between the sensor and the surrounding<br />
gas or gas mixture, e.g. air.<br />
In our capacity as experienced manufacturer, we are well aware of our responsibility to provide our customers<br />
with instruments, that will withstand even the most demanding operating conditions and which<br />
are at the same time easy to use and require little maintenance. However, we wish to remind our customers,<br />
that our instruments will provide an excellent service and provide accurate results, if the following list<br />
of simple operation and maintenance instructions are followed:<br />
1. Analysis of the measuring medium, in which the probe is to be used. What suspended matter and/or<br />
chemicals are present and in what concentration?<br />
2. The probe should be mounted at the correct measuring location, and not where it is most convenient.<br />
3. In case of doubt please contact your ROTRONIC representative.<br />
4. The fi lter has to be changed regularly, if the probe is used in demanding environments. ROTRONIC fi lters<br />
can be cleaned in an ultrasonic bath with suitable detergents. However, it is advisable to keep a spare set<br />
in stock.<br />
5. The perfect function of the sensor should be checked every 6 to 12 months.<br />
6. Calibration of the sensor can be performed by the user with the help of the SCS certifi cated humidity<br />
standards, supplied by ROTRONIC. Calibration of the instruments will ensure, that your measurements<br />
are always verifi able.
ROTRONIC Humidity sensors<br />
Theory<br />
With the HYGROMER ® series, ROTRONIC provides the most advanced capacitive polymer sensor system<br />
for relative humidity measurement. It is the sensor with the largest temperature range (-50…200 °C) available<br />
on the market. This measuring principle is recognised internationally and is based on the change of the<br />
dielectric properties of a polymer as a function of the prevailing relative humidity. The polymer used for<br />
the HYGROMER ® sensor is hygroscopic and has a natural tendency towards equilibrium with the humidity<br />
environment which surrounds it. A corresponding water vapour pressure is formed at the surface of the<br />
polymer depending upon the temperature and the amount of water absorbed into the polymer. Any difference<br />
between this water vapour pressure and the water vapour pressure of the environment is balanced<br />
by an exchange of water molecules until the two are equal. These changes are measured electrically, amplifi<br />
ed and indicated as relative humidity. The amount of water which is absorbed into the polymer is determined<br />
by the ambient humidity and temperature, thus the resulting dielectric properties of the sensor<br />
refl ect the percentage relative humidity (%rh) to which the sensor is exposed.<br />
For many years, the ROTRONIC HYGROMER ® C94 was the best sold sensor. With the disappearing of the<br />
Hygrolyt sensors, new elements were developed in order to even better fulfi l the customers requirements.<br />
An industry sensor does not necessarily need the same properties as a sensor for Water Activity or a sensor<br />
for high-humidity applications. The new sensors represent the results of a continuous research and development.<br />
Sensor Designation Used for Improvements:<br />
HYGROMER ® IN-1 Industry applications Gold connectors,<br />
Temperature range: Meteorology better chemical resistance,<br />
-50...200°C Food technology no corrosion after condensation<br />
Laboratories<br />
Cold rooms<br />
Drying processes<br />
Incubators<br />
HYGROMER ® AC-1 HVAC applications Better chemical resistance,<br />
Temperature range: Cold rooms better Long-term-stability<br />
-30...100°C Storage and transport<br />
Wine cellars<br />
Greenhouses<br />
Museums<br />
Churches<br />
HYGROMER ® WA-1 Water Activity- applications Optimised dimensions for<br />
Temperature range: Food/pharma quality assurance minimal chamber volume,<br />
-30…100°C Product stability Very little hysteresis<br />
Shelf life determination<br />
HYGROMER ® RS-70 High humidity- applications Heated sensor,<br />
Temperature Range: Cheese stocks no condensation,<br />
-50…180°C Meat processing better accuracy in<br />
Tropical greenhouses high range of humidity<br />
Test environments<br />
Climatic chambers<br />
HYGROMER ® RS-20 Brick- and tile making Mechanical stability<br />
Temperature range: Wood-industry Fast response<br />
-50…180°C<br />
HYGROMER ® humidity sensors are always fi tted to a probe or instrument. Thanks to the ROV interface,<br />
probes and instruments with HYGROMER sensors can be connected to any display unit with ROV input.<br />
(10 mV/ °C and 10 mV/%rh)<br />
Characteristics of the sensor<br />
Response time/Time constant<br />
The time constant of a sensor is defi ned as the time required to perform 63% of a humidity change. The<br />
time constant is larger at low temperature, low air movement and high humidity. The time constant also<br />
increases when a fi lter is used. The fi lter reduces the airfl ow over the sensor and a slower diffusion of water<br />
molecules results in a slower response time. Therefore humidity equilibrium is reached after an extended<br />
period of time.<br />
Reproducibility<br />
The specifi cations stated refer to a humidity cycle of 10-95-10 %rh.<br />
T<br />
H<br />
E<br />
O<br />
R<br />
Y<br />
109
T<br />
H<br />
E<br />
O<br />
R<br />
Y<br />
110<br />
Pollutant table<br />
Theory<br />
The following gases have, in the given concentrations, no or little infl uence on the sensor and the humidity<br />
measurement. The data is only a guide. The resistance of the sensor depends strongly on the temperature<br />
and humidity conditions and the duration of the exposure to the pollutant.<br />
Allowed fault caused from the pollutant: ±2%rh<br />
Pollutant Formula Maximum Workplace Allowed Concentration<br />
Concentration Continuous Operation<br />
ppm mg/m 3 ppm mg/m 3<br />
Acetic acid CH3COOH 10 25 800 2000<br />
Acetone CH3COCH3 1000 2400 3300 8000<br />
Ammonia NH3 25 18 5500 4000<br />
2-Butanone (MEK) 300 1200 150000<br />
Chlorine Cl2 0.5 1.5 0.7 2<br />
Ethanol C2H5OH 1000 1900 3500 6000<br />
Ethyl acetate CH3COOC2H5 400 1400 4000 15000<br />
Ethylene glycol HOCH2CH2OH 100 260 1200 3000<br />
Formaldehyde HCHO 1 1.2 2400 3000<br />
Hydrochloric acid HCl 5 7 300 500<br />
Hydrogen sulphide H2S 10 15 350 500<br />
Isopropanol (CH3)2CHOH 400 980 4800 12000<br />
Methylethylketon C2H5COCH3 200 590 3300 8000<br />
Nitrogen oxides NOx 5 9 5 9<br />
Ozone O3 0.1 0.2 0.5 1<br />
Sulphur dioxide SO2 5 13 5 13<br />
Toluene / Xylene C6H5CH3 100 380 1300 5000<br />
Xylol C6H5(CH3)2 100 440 1300 5000<br />
Practical limits<br />
The specifi ed operating ranges must be complied with, otherwise signifi cant errors can arise or the measuring<br />
element could be destroyed.<br />
A replaceable dust fi lter must be used in dusty environment.<br />
Oil and grease vapours will damage the sensor, as they can condense on the sensor and thus prevent or<br />
inhibit response (insulating layer). Flue gases can therefore not be measured .<br />
A fi lter must be used at air velocities above 3 m/s. The sensor must also be protected mechanically from the<br />
high air velocities above 40 m/s (for fi lters, see general accessories).<br />
Sensor properties HYGROMER ®<br />
Operating range IN-1 AC-1 WA-1 RS-20 RS-70<br />
Humidity 0…100%rh<br />
Temperature in °C -50…200 -30…100 -20…180<br />
Air velocity in m/s without<br />
ohne Sensorschutz 3 m/s<br />
Air velocity in m/s with sensor<br />
protection sensor protection 20–40 m/s<br />
Output signals capacitance range<br />
Reproducibility better than 0.5%rh<br />
Long-term stability
Alphabetical Index<br />
Keyword Page<br />
A<br />
A1 11, 13<br />
AC-Adaptor 24<br />
Agent-Accessories 24<br />
Agent-D HT2-EX 20<br />
Agent-D-DataP 24<br />
Agent-D-NT3 20<br />
Agent-D-PT4 20<br />
Alarm device 44–45<br />
Anti theft device 24<br />
AW Quick function 78<br />
B<br />
Bacteria 76<br />
C<br />
Calibration device 98<br />
Carrying case AC1115 11<br />
Ceramics industry 27<br />
Customer branding 92, 93<br />
D<br />
Dataloggers 14<br />
Digital output signal 31<br />
Docking station 5<br />
Drying process 27<br />
E<br />
Equilibrium relative humidity 76, 85<br />
Extension cable 39<br />
F<br />
FDA21 CFR Part 11 100<br />
Filters 36, 39, 57<br />
G<br />
GTS-Set 11<br />
H<br />
Halophile bacteria 76<br />
High temperature applications 27, 29, 34<br />
HPH Signal booster 66<br />
Humidity standard 96, 97<br />
HumidityTheory 104<br />
HW3 software 16, 100<br />
hx diagram 106<br />
HygroClip, various 8, 9, 18, 19, 34, 35, 37, 39,64<br />
Hygrodata quick 102<br />
HygroFlex 30ff<br />
HygroLab 80<br />
HygroLog Accessories 24<br />
HygroLog, HygroLogD 16<br />
Hygromer sensor 109<br />
HygroPalm /1/2/3 16<br />
HygroPalm Aw1 81<br />
HygroPalm-Set 10<br />
Hygrowin 65<br />
I<br />
I-1000 Transmitter 56–61<br />
Impact protection 24<br />
Industrial probes 34 ff<br />
Installation 43<br />
Intrinsically safe 56<br />
Humidity and temperature measurement<br />
Keyword Page<br />
M<br />
M1/M2/M3 48–52<br />
Meteorology probes 71–75<br />
Mildew 76<br />
MOC, MOC3 64<br />
Moisture content 85<br />
MOK, MOK3, MOK-WIN 50, 64, 65<br />
Mounting Accessories 60<br />
M-Series Transmitter 46ff<br />
N<br />
Networking 24<br />
O<br />
OEM Products, OEM Sensors 92ff<br />
Osmiophile yeast 76<br />
P<br />
Paper industry 11, 27<br />
Pollutant table 110<br />
Portable Analyser 76, 81<br />
PPS probe 8, 56<br />
Pressure probe 32<br />
Printer, Printer cable 24<br />
Probe extension cable 24, 36, 65<br />
Probe Simulator 65<br />
Psychrometric calculations 103<br />
R<br />
Radio Option 33<br />
Remote control<br />
Roline L Transmitters 53–55<br />
S<br />
SCS 46, 97<br />
Sensor protection 36<br />
Software validation 16, 100ff<br />
T<br />
Temperature Adaptor 12<br />
Temperature Logger 20<br />
Temperature probes 22<br />
Transmitter 28ff<br />
V<br />
VHTS2-shield 70, 74<br />
W<br />
Wall mounting bracket 24<br />
Water Activity 76ff<br />
Weather protection shield 70<br />
X<br />
Xerophile mildew 76<br />
Y<br />
Yeast 41<br />
Z<br />
Zener barrier 37, 39<br />
I<br />
N<br />
D<br />
E<br />
X<br />
111
O<br />
N<br />
-<br />
L<br />
I<br />
N<br />
E<br />
S<br />
H<br />
O<br />
P<br />
S<br />
112<br />
Switzerland:<br />
www.humidity-shop.ch<br />
www.humidity-shop.ch<br />
France:<br />
www.rotronic.fr<br />
www.rotronic.fr<br />
ROTRONIC On-Line Shops<br />
Visit us On-Line!<br />
Germany:<br />
www.rotronic-shop.de<br />
www.rotronic-shop.de<br />
England:<br />
www.humidity-shop.co.uk<br />
www.humidity-shop.co.uk
1. General<br />
1.1 These general conditions of sale and supply<br />
shall be binding when such have been<br />
stated as being applicable in an offer or<br />
confi rmation of order of and by ROTRONIC<br />
<strong>Instruments</strong> (UK) Ltd<br />
1.2 Orders shall only become binding upon<br />
ROTRONIC <strong>Instruments</strong> (UK) Ltd after it has<br />
issued a written confi rmation of order.<br />
1.3 These general conditions of sale and supply<br />
shall become valid as from January 1, 2000.<br />
2. Prices<br />
Prices shall be deemed net plus transportation<br />
and packaging charges (V.A.T. at prevailing rate<br />
applies), provided that alternative conditions have<br />
not already been agreed. ROTRONIC <strong>Instruments</strong><br />
(UK) Ltd however hereby reserves the right to<br />
make price adjustments to cover defi nite increases<br />
in costs as for example the cost of wages, goods<br />
and materials.<br />
3. Delivery period<br />
The delivery period shall be the date laid down<br />
in the contract of sale and such may be extended<br />
should diffi culties arise that may have been caused<br />
by act of God or force majeure such as war, epidemics<br />
and among other things storm and tempest.<br />
4. Despatch<br />
All deliveries shall be effected for the account and<br />
the risk of the customer. Any complaints concerning<br />
damage, loss or delay are to be reported to<br />
ROTRONIC <strong>Instruments</strong> (UK) Ltd within 7 days after<br />
the receipt of the consignment; but complaints<br />
concerning any faulty packaging shall be rendered<br />
on the same day as the receipt of the consignment.<br />
5. Works deliveries<br />
Should the consignment and invoicing be directly<br />
effected by the works supplier of ROTRONIC<br />
<strong>Instruments</strong> (UK) Ltd, the conditions of sale and<br />
supply of that particular works supplier shall be<br />
valid for customers in respect of that particular<br />
contract. In such cases, these present conditions<br />
of sale and supply shall have no validity and damage<br />
indemnity claims or claims of any other nature<br />
cannot be made enforceable against ROTRONIC<br />
<strong>Instruments</strong> (UK) Ltd hereunder.<br />
6. Return of goods and materials<br />
The return of goods and materials shall require<br />
the written permission of ROTRONIC <strong>Instruments</strong><br />
(UK) Ltd and may only be effected if the goods and<br />
materials are in irreproachable condition and still<br />
in their original packaging, and only then if such<br />
are usually maintained in stock by ROTRONIC<br />
<strong>Instruments</strong> (UK) Ltd. A copy of the delivery note<br />
or the invoice must be enclosed. Returns without<br />
either a copy of the delivery note or the invoice will<br />
not be accepted. An appropriate surcharge will be<br />
levied by ROTRONIC <strong>Instruments</strong> (UK) Ltd on the<br />
purchaser to defray the cost of any inconvenience<br />
caused.<br />
Terms and Conditions of Trading<br />
7. Settlement<br />
Provided that alternative conditions have not already<br />
been agreed, invoices are to be settled net<br />
within 30 days without any deductions. Purchasers<br />
will be charged the usual bank overdraft rate of interest<br />
in respect of overdue payments.<br />
8. Retention of ownership rights<br />
All goods and materials supplied shall remain the<br />
property of ROTRONIC <strong>Instruments</strong> (UK) Ltd until<br />
full payment of the debited invoice amount shall<br />
have been received. The purchaser and the holder<br />
of the goods and materials shall in addition be under<br />
a duty hereunder to contract insurance cover<br />
for the goods and materials and, in their capacity<br />
as the insured, to assign any insurance claim of the<br />
purchaser to ROTRONIC <strong>Instruments</strong> (UK) Ltd<br />
9. Warranty<br />
ROTRONIC <strong>Instruments</strong> (UK) Ltd will grant a warranty<br />
for plant and equipment for a period of 24<br />
months from the date of delivery in respect of<br />
any evidenced faulty workmanship and materials.<br />
Should a delivered consignment prove to be<br />
contrary to contract upon inspection, the customer<br />
shall grant ROTRONIC <strong>Instruments</strong> (UK) Ltd the<br />
opportunity hereunder of removing the fault, or<br />
else the customer may demand replacement.<br />
Should the supply or delivery of any improvement<br />
or replacement not prove possible, the customer<br />
may choose between having the purchase price<br />
reduced or in demanding the contract of, sale to<br />
be rescinded (conversion). Damage resulting from<br />
natural wear and tear, act of God, force majeure,<br />
non compliance with the operating instructions<br />
shall be excluded from the warranty as well as mechanical<br />
interference by the customer or by third<br />
parties with plant and equipment of ROTRONIC<br />
<strong>Instruments</strong> (UK) Ltd without its written permission.<br />
10. Cancellation<br />
Cancellation of orders shall only be possible hereunder<br />
with the written approval of ROTRONIC<br />
<strong>Instruments</strong> (UK) Ltd. Any costs which shall have<br />
already been incurred or price increases as a result<br />
of reductions in amounts ordered shall be for the<br />
account of the purchaser. Partial supplies of an<br />
order contracted upon call shall be claimed within<br />
the agreed supply and delivery periods, otherwise<br />
ROTRONIC <strong>Instruments</strong> (UK) Ltd may cause the<br />
relative consignment and invoice billing there fore<br />
to be made.<br />
11. Place of jurisdiction<br />
The place of jurisdiction hereunder shall be<br />
London, England. The purchaser expressly declares<br />
and agrees hereunder to waive the usual<br />
place of domicile as place of jurisdiction in favour<br />
of the foregoing jurisdiction agreed hereunder.<br />
Legal relationships hereunder shall be subject to<br />
UK law.