14. Water filter<br />

The water filter removes dirt from the water to prevent damage<br />

to the pump or blockage of the evaporator. The water filter must<br />

be cleaned on a regular base. See "Maintenance and service"<br />

on page 38.<br />

15. Manometer<br />

The manometer allows readout of the water pressure in the<br />

water circuit.<br />

16. Flow switch<br />

The flow switch checks the flow in the water circuit and protects<br />

the heat exchanger against freezing and the pump against<br />

damage.<br />

17. Pump<br />

The pump circulates the water in the water circuit.<br />

18. Backup heater thermal protector<br />

The backup heater is equipped with a thermal protector. The<br />

thermal protector is activated when the temperature becomes<br />

too high.<br />

19. Backup heater thermal fuse<br />

The backup heater is equipped with a thermal fuse. The thermal<br />

fuse is blown when the temperature becomes too high (higher<br />

than the backup heater thermal protector temperature).<br />

20. Pressure relief valve<br />

The pressure relief valve prevents excessive water pressure in<br />

the water circuit by opening at 43.5 psi (3 bar) and discharging<br />

some water.<br />

21. Pressure relief valve hose<br />

The actual outlet of the pressure relief valve. Make sure to<br />

provide a proper drain.<br />

10<br />

12<br />

8<br />

9<br />

10<br />

11<br />

1. Air purge valve<br />

Remaining air in the water circuit will be automatically removed<br />

via the air purge valve.<br />

2. Backup heater<br />

The backup heater consists of an electrical heating element in<br />

the backup heater vessel that will provide additional heating<br />

capacity to the water circuit if the heating capacity of the outdoor<br />

unit is insufficient due to low outdoor temperatures.<br />

3. Temperature sensors<br />

Four temperature sensors determine the water and refrigerant<br />

temperature at various points in the water circuit.<br />

4. Switch box<br />

The switch box contains the main electronic and electrical parts<br />

of the indoor unit.<br />

5. Heat exchanger<br />

6. Expansion vessel (2.6 gallons) [10 l]<br />

7. User interface<br />

The user interface allows the installer and user to set up, use<br />

and maintain the unit.<br />

8. Refrigerant liquid connection<br />

9. Refrigerant gas connection<br />

10. Shut-off valves (accessory)<br />

The shut-off valves on the water inlet connection and water<br />

outlet connection allow isolation of the indoor unit water circuit<br />

side from the residential water circuit side. This facilitates<br />

draining and filter replacement of the indoor unit.<br />

11. Water inlet connection<br />

12. Water outlet connection<br />

13. Drain and fill valves<br />

Installation manual<br />

10<br />

EKHBH/X054BA<br />

Indoor unit for air to water heat pump system<br />

4PW54216-1