ENGLISH<br />

46<br />

TYPE OF BEVERAGE<br />

disabled<br />

1 short coffee<br />

2 short coffees<br />

1 long coffee<br />

2 long coffees<br />

1 carafe<br />

1 jug<br />

1 cappuccino<br />

2 cappuccinos<br />

1 white coffee<br />

2 white coffees<br />

1 milk<br />

2 milks<br />

The description of the type of beverage<br />

will then be shown on the display each<br />

time we want to review the description of<br />

the button.<br />

The ENTER button confirms the value and<br />

you can proceed to the following paragraph.<br />

The RESET button takes you back to the<br />

previous menu: BUTTON SELECTION<br />

leaving the value of the parameter as it<br />

was before the alteration.<br />

Right or left grinder<br />

The grinder associated with the button<br />

selected, , is defined.<br />

The ▼ and ▲ buttons allow you to select<br />

the grinder: right grinder or left grinder.<br />

The ENTER button confirms the value and<br />

you can proceed to the following paragraph.<br />

The RESET button takes you back to the<br />

previous menu leaving the value of the<br />

parameter as it was before the alteration.<br />

Pre-infusion<br />

The pre-infusion time of the dose is programmed.<br />

The ▼ and ▲ buttons allow you to alter the<br />

pre-infusion time: 0.0÷10.0 sec., step 0.1<br />

sec. Setting 0.0, the pre-infusion is disabled.<br />

The ENTER button confirms the value and<br />

you can proceed to the following paragraph.<br />

The RESET button takes you back to the<br />

previous menu leaving the value of the<br />

parameter as it was before the alteration.<br />

Discharge<br />

The discharge time is programmed (time<br />

needed for drying the coffee PASTIGLIA<br />

after delivery). The ▼ and ▲ buttons allow<br />

you to alter the discharge time: 0.0÷10.0<br />

sec, step 0.1 sec. With a setting of 0.0 the<br />

discharge is disabled.<br />

The ENTER button confirms the value and<br />

you can proceed to the following paragraph.<br />

The RESET button takes you back to the<br />

previous menu leaving the value of the parameter<br />

as it was before the alteration.<br />

Upper motor<br />

The running time of the upper motor is<br />

programmed before running the lower<br />

motor during the discharge phase. The<br />

buttons ▼ and ▲ allow you to alter the running<br />

time: 0.5-1.5 sec. Step 0.1 sec.<br />

The ENTER button confirms the value and<br />

you can proceed to the following paragraph.<br />

The RESET button takes you back to the<br />

previous menu leaving the value of the<br />

parameter as it was before the alteration.<br />

Lower motor<br />

The running time for the upper motor is<br />

programmed from the beginning of the<br />

cycle to define the compression of the coffee<br />

powder.<br />

The ▼ and ▲ buttons allow you to alter<br />

the discharge time: 0.0÷10.0 sec. With a<br />

setting of 0.0 the discharge is disabled.<br />

The ENTER button confirms the value and<br />

you can proceed to the following paragraph.<br />

If it is the last parameter of the<br />

dose go back to the previous menu.<br />

The RESET button takes you back to the<br />

previous menu leaving the value of the<br />

parameter as it was before the alteration.<br />

Button parameters<br />

The following table lists the parameters<br />

requested for programming the buttons for<br />

each type of beverage.<br />

COFFEE SELECTIONS<br />

Parameter Range Step<br />

priority grinder right grinder -<br />

left grinder<br />

pre-infusion 0.0÷10.0 sec. 0.1 sec.<br />

discharge time 0.0÷10.0 sec. 0.1 sec.<br />

upper motor time 0.5÷1.5 sec. 0.1 sec.<br />

lower motor time 0.0÷1.0 sec. 0.1 sec.<br />

CAPPUCCINO SELECTIONS<br />

Parameter Range Step<br />

priority grinder right grinder -<br />

left grinder<br />

pre-infusion 0.0÷10.0 sec. 0.1 sec.<br />

discharge time 0.0÷10.0 sec. 0.1 sec.<br />

upper motor time 0.5÷1.5 sec. 0.1 sec.<br />

lower motor time 0.0÷1.0 sec. 0.1 sec.<br />

sequence milk-coffee -<br />

coffee-milk<br />

milk discharge 0.0÷5.0 sec. 0.1 sec.<br />

MILK SELECTIONS<br />

Parameter Range Step<br />

milk discharge 0.0÷5.0 sec. 0.1 sec.<br />

CAFFE LATTE SELECTIONS<br />

Parameter Range Step<br />

priority grinder right grinder -<br />

left grinder<br />

pre-infusion 0.0÷10.0 sec. 0.1 sec.<br />

discharge time 0.0÷10.0 sec. 0.1 sec.<br />

upper motor time 0.5÷1.5 sec. 0.1 sec.<br />

lower motor time 0.0÷1.0 sec. 0.1 sec.<br />

milk discharge 0.0÷5.0 sec. 0.1 sec.