Flexel® 3D LevMix System for Drum
Flexel® 3D LevMix System for Drum
Flexel® 3D LevMix System for Drum
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Pictures & Descriptions of Available Accessories<br />
I. Magnetic charger with shield (two types: LT-DBCI001, LT-DBCI005)<br />
II. Interface<br />
III. Centering aligner<br />
IV. Magnetic clamp<br />
V. Test impeller with shield (two types: LT-DBAK004, LT-DBAK007)<br />
VI. O-ring<br />
Figure A: From left to right, Magnetic Charger (LT-DBCI001), Shield <strong>for</strong> Magnetic Charger,<br />
(LT-DBAK011) and Magnetic Charger (LT-DBCI001) coupled with Shield. During the<br />
charging procedure, the ball bearing (red in far left picture) should rest on the surface of<br />
the levitation head of the drive unit.<br />
Figure B: From left to right, Magnetic Charger (LT-DBCI005), Shield <strong>for</strong> Magnetic Charger,<br />
(LT-DBAK011) and Magnetic Charger (LT-DBCI005) coupled with Shield. During the<br />
charging procedure, the ball bearing (red in far left picture) should rest on the surface of<br />
the levitation head of the drive unit.<br />
Magnetic Charger & Test Impeller Chart<br />
Magnetic Charger Corresponding Test Impeller Magnet Configuration<br />
LT-DBCI001 LT-DBAK004 6-magnet charger & impeller<br />
LT-DBCI005 LT-DBAK007 4-magnet charger & impeller<br />
Note:<br />
the appropriate magnetic charger must be used to set the drive machine <strong>for</strong> use with the<br />
corresponding impeller. The machine will not properly drive an impeller which does not have<br />
the corresponding magnet configuration.<br />
6