Preparations<br />

19.5. Countercooling<br />

40<br />

20<br />

80<br />

120<br />

RS 232 C<br />

14<br />

°C ALARM<br />

SCHO<strong>TT</strong> Instrument GmbH<br />

D65719 Hofheim/Ts.<br />

Typ <strong>CT</strong> 52 Nr 000000<br />

230 V /50 Hz 2070 VA<br />

KL 2 DIN 12879<br />

Made in Germany<br />

15<br />

16a<br />

16b<br />

15<br />

Connection to cooling (tap) water<br />

For applications near the ambient temperature, the cooling coil must<br />

be connected to the water mains.<br />

• Using tubing, connect the cooling coil to the tap water supply,<br />

and lead the tap water in a sink through the return connector.<br />

• A specific water flow rate of 100 ml/minute is sufficient to<br />

compensate for the characteristic temperature.<br />

Recommendation: Use a flow-rate regulator.<br />

15 nozzles 2 x 8 mm dia. for tap water cooling<br />

External Cooling Devices<br />

Recommended in combination with <strong>CT</strong> <strong>53</strong>, <strong>CT</strong>54, <strong>CT</strong> <strong>53</strong> HT and<br />

<strong>CT</strong> 54 HT<br />

With the flow-through cooler CK 300 from SCHO<strong>TT</strong>-GERÄTE, the<br />

heat transfer liquid can be cooled down and the transparent<br />

thermostat can be rendered independent of tap water.<br />

• Installation and use are described in the instruction manual for<br />

the cooler.<br />

16a Pump connector: Feed<br />

16b Pump connector: Return<br />

nozzles 2 x 12 mm dia. for flow-through cooler (CK 300)<br />

14 5-pin socket for control cable to the flow-through cooler<br />

(CK 300)<br />

Recommended in combination with <strong>CT</strong> <strong>53</strong> <strong>TT</strong><br />

Using an appropriate refrigerated circulator, the bath liquid can be<br />

cooled down to -40 °C.<br />

• Installation and use are described in the instruction manual for<br />

the refrigerated circulator.<br />

15 Using the nozzles 2 x 8 mm dia. connect the tubing onto the<br />

pump nozzles of the refrigerated circulator.