EN<br />

420010243500 Maior P <strong>45</strong>/<strong>60</strong>/<strong>80</strong>/120 AB<br />

Two-pipe siphon feed system<br />

MAXIMUM LENGTH OF SUCTION LINES FOR TWO-PIPE SYSTEM<br />

H<br />

H<br />

(m)<br />

0<br />

0,5<br />

1<br />

2<br />

3<br />

3,5<br />

AS 67 / AN 77<br />

(m)<br />

ø 10 mm ø 12 mm<br />

32<br />

36<br />

40<br />

48<br />

56<br />

<strong>60</strong><br />

Pipe length<br />

90<br />

90<br />

90<br />

90<br />

90<br />

90<br />

ø 14 mm<br />

22<br />

25<br />

30<br />

35<br />

38<br />

40<br />

AJ 6<br />

(m)<br />

ø 16 mm<br />

38<br />

<strong>45</strong><br />

50<br />

<strong>60</strong><br />

70<br />

<strong>80</strong><br />

Two-pipe lift system<br />

H<br />

(m)<br />

AS 67 / AN 77<br />

(m)<br />

Pipe length<br />

ø 10 mm ø 12 mm<br />

AJ 6<br />

(m)<br />

ø 14 mm ø 16 mm<br />

H<br />

0<br />

0,5<br />

1<br />

2<br />

3<br />

3,5<br />

25<br />

21<br />

18<br />

10<br />

5<br />

---<br />

70<br />

62<br />

54<br />

38<br />

20<br />

10<br />

25<br />

20<br />

18<br />

10<br />

5<br />

2<br />

<strong>45</strong><br />

38<br />

33<br />

20<br />

10<br />

4<br />

To correct length of pipes is calculated by summing up the length of all vertical and horizontal right sections<br />

and bends. The static suction head will be the distance between the non-return valve and the<br />

burner’s pump axle. The depression must not be greater than 0.<strong>45</strong> bar; should it be higher, some damages<br />

could occur to the pump, with consequent increase in mechanical noises and ,eventually, a failure.<br />

NOZZLE FLOW RATE<br />

DELAVAN B - MONARCH PLP<br />

NOZZLE<br />

PUMP PRESSURE (bar)<br />

GPH 10 11 12 13 14 15 16<br />

2,50 9,50 9,97 10,41 10,83 11,24 11,64 12,02<br />

3,00 11,40 11,96 12,49 13,00 13,49 13,96 14,42<br />

3,50 13,30 13,95 14,57 15,17 15,74 16,29 16,83<br />

4,00 15,20 15,94 16,65 17,33 17,99 18,62 19,23<br />

4,50 17,10 17,94 18,73 19,50 20,24 20,95 21,63<br />

5,00 19,00 19,93 20,82 21,67 22,48 23,27 24,04<br />

5,50 20,90 21,92 22,90 23,83 24,73 25,<strong>60</strong> 26,44<br />

6,00 22,<strong>80</strong> 23,92 24,98 26,00 26,98 27,93 28,84<br />

6,50 23,70 25,91 27,06 28,17 29,23 30,26 31,25<br />

7,00 26,<strong>60</strong> 27,90 29,14 30,33 31,48 32,58 33,65<br />

7,50 28,50 29,90 31,22 32,50 33,73 34,91 36,05<br />

8,30 31,54 33,08 34,55 35,97 37,32 38,63 39,90<br />

9,50 36,10 37,87 39,55 41,17 42,72 44,22 <strong>45</strong>,67<br />

10,50 40,06 41,73 43,74 <strong>45</strong>,41 47,20 48,90 50,50<br />

12,00 <strong>45</strong>,<strong>60</strong> 47,<strong>80</strong> 50,00 52,00 54,00 55,90 57,70<br />

13,<strong>80</strong> 52,40 55,00 57,50 59,<strong>80</strong> 62,10 64,20 66,30<br />

15,30 58,10 61,00 63,70 66,30 68,<strong>80</strong> 71,10 73,<strong>60</strong><br />

17,50 66,50 69,<strong>80</strong> 72,90 75,<strong>80</strong> 78,70 81,50 84,10<br />

19,50 74,10 77,70 81,20 84,50 87,70 90,<strong>80</strong> 93,70<br />

21,50 81,70 85,70 89,50 93,20 96,70 100,10 103,40<br />

24,00 91,20 95,70 99,90 104,00 107,90 111,70 115,40<br />

GPH<br />

OUTPUT kg/h<br />