12.07.2015 Views

Ventilmagnet nach Valve solenoids according to ... - Duncan Rogers

Ventilmagnet nach Valve solenoids according to ... - Duncan Rogers

Ventilmagnet nach Valve solenoids according to ... - Duncan Rogers

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

18 Disruptions/Technical dataBosch Rexroth4 Disruptions4.1 ProcedureCheck the cable connections, operating voltage, andthe operating pressure if there are any disruptions.If this does not solve the problem, check that thedevice is pressure-free, disconnect the device fromthe power supply, and contact an authorized andtrained specialist for repairs.5 Technical data5.1 Temperature class T5Width: 30 mmMaximum permissable media temperature 80°COperating voltage <strong>to</strong>lerance +/- 10%Operating pressure depending on armature/valvesystemMaximum 12 bar<strong>Valve</strong> <strong>solenoids</strong> 1 827 414 297 - 1 827 414 312II 2G EEx m II T5 IEC Ex m II T5II 3D IP65 T95 °C5.2 Electrical performanceTypeType of currentTemperature inindividual operationor battery assemblyBattery assembly,minimum distance1 827 414 297 <strong>to</strong> 3021 827 414 305 <strong>to</strong> 310Alternating current50 <strong>to</strong> 60 Hz-20°C - +50°C-20°C - +50°CYes0 mm1 827 414 303 and 3041 827 414 311 and 312Direct current,max. 20% ripple-20°C - +50°C-20°C - +40°CYes0 mm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!