2.4 Recycling/Disposal<br />

Disposing of this product and its packaging in the correct manner protects people and the environment.<br />

The battery and display unit must not be burnt and must not be disposed of in domestic waste. Please<br />

ensure that these are disposed of correctly, in accordance with local regulations. See also Chapter 11.<br />

Used fi lter cartridges can be returned to the addresses listed.<br />

3 Operating and Safety Instructions<br />

3.1 Qualifi ed Personnel<br />

Installation and maintenance of the fi lter system may be carried out only by trained and authorised<br />

personnel.<br />

3.2 Correct Use<br />

The product can only operate perfectly and safely if it is installed, used and serviced in the manner<br />

described in this handbook.<br />

Note: the fi lter system and system-specifi c <strong>HYDROLINE</strong> <strong>STEAM</strong> fi lter cartridges may only be used<br />

upstream from end devices such as hot air steamers, combi ovens and conventional ovens.<br />

3.3 Liability Exclusion<br />

Installation must be performed precisely in accordance with the instructions in this handbook.<br />

Hobart shall not be held liable for any damage, including subsequent damage, arising from the incorrect<br />

installation or use of the product.<br />

3.4 Specifi c Safety Information<br />

• Only water of drinking water quality may be used as intake water for the Hobart water fi lter system.<br />

The Hobart water fi lter system is only suitable for cold water use within the water intake<br />

temperature stated in Chapter 12. No microbiologically impaired water or water of unknown<br />

quality may be used without prior appropriate disinfection.<br />

• If there are offi cial instructions to boil tap water, the fi lter system must be decommissioned.<br />

When the requirement to boil water comes to an end, the fi lter cartridge must be replaced and<br />

the connections cleaned.<br />

• For hygiene reasons, the fi lter material of the cartridge is subjected to a special treatment with<br />

silver. A small quantity of silver, which is harmless to health, may be released into the water.<br />

This is in compliance with the World Health Organisation (WHO) recommendations for drinking<br />

water. At most, the values stated in the Codes Alimentarius Austriacus may be exceeded.<br />

• Note for people with kidney disease or dialysis patients: During the fi lter process the potassium<br />

content may be increased slightly. If you suffer from kidney disease and/or have to stick to a<br />

special potassium diet, we recommend prior agreement with your doctor.<br />

• The water fi ltrate is classifi ed in Category 2 according to DIN EN 1717.<br />

• Hobart recommends that the fi lter system not be decommissioned for a long period. If the<br />

Hobart <strong>HYDROLINE</strong> <strong>STEAM</strong> fi lter system is not used for several days (two to three days), we<br />

recommend that the fi lter system be fl ushed with at least X litres according to the table below.<br />

After stagnation periods of over four weeks, the fi lter should be fl ushed with at least Y litres or<br />

else replaced. Please also note that the maximum usage period of the fi lter cartridge is twelve<br />

months (Chapter 6).<br />

20<br />

Filter system Flush quantity X<br />

after 2–3 days stagnation<br />

Flush quantity Y<br />

after 4 weeks stagnation<br />

<strong>HYDROLINE</strong> <strong>STEAM</strong> 24 litres 120 litres<br />

• The fi lter system is not resistant to heavily concentrated cleaning agents (e.g. bleach, chlorinated<br />

solvents, heavy oxidants) and must not come into contact with them.<br />

• The fi lter system must not be opened or dismantled during operation. The fi lter cartridge must<br />

not be opened.<br />

• The pressure vessel and the pressure vessel lid of the fi lter systems have a service life of up<br />

to ten years (from the date of installation), provided that they are installed and used correctly