Error level E2 indicates whether and from when until when an error has occurred at the outlet water<br />

meter. Display is similar to level E1.<br />

Program Overview<br />

20 sec. no activity Operating mode<br />

Carbonate hardness<br />

Capacity By-pass<br />

last fi lter change date<br />

30 sec.no activity =<br />

no Parameter acceptance<br />

1 x button Press button 4 seconds<br />

32<br />

Retrieval mode<br />

ID-Information<br />

���<br />

00 Current level<br />

���<br />

-1 History level 1<br />

���<br />

-2 History level 2<br />

���<br />

-3 History level 3<br />

���<br />

-4 History level 4<br />

���<br />

E1 Error inlet metre<br />

���<br />

E2 Error drainage metre<br />

10 Troubleshooting<br />

Parameterisation<br />

Filter system type and size 2 sec.<br />

���<br />

Type of hardness (unit)<br />

and value 2 sec.<br />

���<br />

Monthly limit 2 sec.<br />

���<br />

RESET 2 sec.<br />

���<br />

Parameter acceptance<br />

10.1 No water fl ow<br />

Cause: Water intake closed.<br />

Troubleshooting: Open water intake on the upstream stop valve or inlet valve 7 on inlet hose 6 .<br />

! Caution: The following faults may be remedied only by trained and authorised personnel.<br />

10.2 No or low water fl ow in spite of open water intake<br />

Cause: Mains pressure too low.<br />

Troubleshooting: Check mains pressure.<br />

If the fault continues in spite of adequate mains pressure, check the fi lter<br />

system and fi lter cartridge and change if necessary.<br />

! Caution: Prior to changing, read the Technical Data (Chapter 12) and the<br />

Operating and Safety Information (Chapter 3).<br />

10.3 Leak at Screwed Connections<br />

Cause: Screwed connections not fi tted correctly.<br />

Troubleshooting: Check mains pressure. Check all screwed connections and mount according to<br />

Chapter 4.<br />

If the fault continues, exchange fi lter system.