Commander SK - Control Techniques
Commander SK - Control Techniques
Commander SK - Control Techniques
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
3-polige klemmenstrook<br />
Klem Functie<br />
1 Netwerk data line A<br />
2 Netwerk data line B<br />
3 Scherm<br />
Parameters<br />
Para- Beschrijving Fabr. Para- Beschrijving Fabr.<br />
meter<br />
inst meter<br />
inst<br />
15.01 Module ID code 401 15.30 Load option defaults OFF<br />
15.02 Firmware version 15.31 Save option parameters OFF<br />
15.03 Node address 0 15.32 Request to re-initialise OFF<br />
15.06 Diagnostics: messages per second 0 15.33 Restore parameters from option module OFF<br />
15.07 Network loss trip 0 15.34 Initialise drive reference selectors OFF<br />
15.10 Subnet ID 15.35 Option module serial number -<br />
15.11 Domain ID length 0 15.36 Transmit service pin message OFF<br />
15.12 Domain ID byte 1 0 15.37 Winl active OFF<br />
15.13 Domain ID byte 2 0 15.38 Unconfigure option module 0<br />
15.14 Domain ID byte 3 0 15.39 Default configuration property storage 0<br />
15.15 Domain ID byte 4 0<br />
15.16 Domain ID byte 5 0 15.50 SM-LON error codes 0<br />
15.17 Domain ID byte 6 0 15.51 Minor firmware version<br />
Error codes<br />
De errorcode is weergegeven in #15.50<br />
Kleur:<br />
Zacht groen<br />
<strong>SK</strong> menu 15<br />
SM-LON optiemodule<br />
Errorcode<br />
Fout Beschrijving<br />
0 Geen fout gedetecteerd Indicatie dat de trip niet werd veroorzaakt door SM-LON, mogelijk via externe<br />
communicatie kanalen.<br />
58 Incorect non-volatile storage At least one configuration property was incorrectly formatted or corrupt.<br />
Configuration property defaults are downloaded<br />
61 Invalid configuration parameters This trip will occur if the SM-LON option module is installed in a Unidrive SP<br />
configured in regen mode<br />
65 Network loss<br />
70 No valid fieldbus data available No valid fieldbus data available in the module to download to the drive. The<br />
user may not have saved any data or the data save may not have completed<br />
successfully<br />
74 Overtemperatuur in de optiemodule Temperatuur in de optiemodule > 82 °C, <strong>Commander</strong> <strong>SK</strong> geeft trip 74<br />
99 Interne software fout<br />
<strong>SK</strong> handleiding, versie 7 pagina 138 van 154<br />
SM-Optiemodule frontaanzicht<br />
Dipschakelaar<br />
out<br />
in<br />
1 2 3<br />
A B S<br />
2 stuks 56 Ohm<br />
ballast weerstanden<br />
W<br />
S<br />
Wink LED<br />
Service LED